Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bone imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Nondestructive geochemical characterization of fossil hominin taphonomy and burial history

To date, only three Homo habilis specimens have been discovered that have associated craniodental and postcranial elements, providing a limited fossil record of the ontogeny and morphology of early members of the genus Homo. Recently, a nearly complete dentition, likely attributable to H. habilis, was discovered and excavated from early Pleistocene-age fluvial-lacustrine sediments of the upper Burgi Member of the Koobi Fora Formation at site F25787 in Area 13, near Ileret, Kenya. On the surface less than 15 m away, at site F25966, postcranial elements were found, which, if from the same individual as the nearby dentition, would represent the fourth associated craniodental and postcranial assemblage of this species. We developed a geochemical taphonomic history of these ca. 2 Ma hominin fossils using nondestructive X-ray based microanalytical tools (synchrotron and benchtop X-ray fluorescence chemical imaging and micro- and nano-computed tomography volumetric reconstruction), bulk analyses of sediments and paleosols at the excavation sites, and sedimentologic and stratigraphic observations. We integrate the chemical and physical taphonomic histories to test whether teeth (excavated in situ) and postcranial bones (eroded onto the outcrop surface) derive from a single individual. Minor differences in taphonomic history are attributable to the different biomineral properties of the dental and osseous components and to differences in physical damage during early post-mortem scavenging, dispersal, and burial in adjacent depositional settings. Microscale geochemical mapping enabled the temporal ordination of chemical and physical events in the specimens’ chemical taphonomic histories. Specifically, authigenic Fe- and K-bearing clays and Y, U, and Sr uptake occurred in post-burial fractures in bones and were also incorporated pervasively throughout dentin in teeth. Barite mineralization occurred along the latest fractures in both materials, and as a coating on tooth roots. The stratigraphic, taphonomic, and geochemical evidence supports the interpretation that the hominin fossils represent a single individual. Finally, successful application of these nondestructive sample characterization methods demonstrates capabilities for thorough interrogation of the taphonomic histories of other potential hominin fossil associations, enabling more robust and accurate palaeontologic constraints using those relationships.

36 MATERIALS SCIENCE↗

Space radiation absorbed dose distribution in a human phantom

The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

STS-91 Shuttle Project↗

Exercise Sensing and Pose Recovery Inference Tool (ESPRIT) - A Compact Stereo-based Motion Capture Solution For Exercise Monitoring

Crew exercise is important during long-duration space flight not only for maintaining health and fitness but also for preventing adverse health problems, such as losses in muscle strength and bone density. Monitoring crew exercise via motion capture and kinematic analysis aids understanding of the effects of microgravity on exercise and helps ensure that exercise prescriptions are effective. Intelligent Automation, Inc., has developed ESPRIT to monitor exercise activities, detect body markers, extract image features, and recover three-dimensional (3D) kinematic body poses. The system relies on prior knowledge and modeling of the human body and on advanced statistical inference techniques to achieve robust and accurate motion capture. In Phase I, the company demonstrated motion capture of several exercises, including walking, curling, and dead lifting. Phase II efforts focused on enhancing algorithms and delivering an ESPRIT prototype for testing and demonstration.

Lee, Mun Wai↗

The Hopper: A Wearable Robotic Device Testbed for Micro-Gravity Bone-Loading Proof-of-Concept

Wearable robotic systems are showing increased potential for addressing crew countermeasures needs. Wearable robots offer a compactness, programmability, and eccentric loading capability not present in more conventional exercise equipment. Correspondingly, advancements in the man to machine interface has progressed, allowing for higher loads to be applied directly to the person in new and novel ways. Recently, the X1 exoskeleton, a lower extremity wearable robot originally designed for mobility assistance and rehabilitation, underwent human subject testing to assess its potential as a knee dynamometer. This was of interest to NASA physiologists because currently strength is not assessed in flight due to hardware limitations, and thus there is a poor understanding of the time course of in-flight changes to muscle strength. The study concluded that the X1 compared well with the Biodex, the "gold standard" in terrestrial dynamometry, with coefficients of variation less than 6.0%. In a following study, the X1 powered ankle was evaluated for its efficacy in exercising calf muscles. Current on-orbit countermeasures equipment does not adequately protect the calf from atrophy. The results of this study were also positive (targeted muscle activity demonstrated via comparing pre- and post-exercise magnetic resonance imaging T2 measurements), again showing the efficacy of wearable robotic devices for addressing the countermeasure needs of our astronauts. Based on these successes and lessons learned, the Grasshopper was co-developed between IHMC (Florida Institute for Human and Machine Cognition) and NASA. The Grasshopper, or the Hopper for short, is a wearable robotic device designed to address muscle and bone density loss for astronauts spending extended periods of time in micro-gravity. The Grasshopper connects to the user's torso like a hiking backpack, over the shoulders and around the waist. At the feet are footplates that strap to the user. There are two actuators, one at each "knee" joint, which are capable of high fidelity torque control. Because the Hopper uses motors instead of gravity to create the load on the user, the device is suited for use on space missions. Exercise in zero-gravity conditions is critical to maintain muscle strength and bone mass. In operation, the actuators try to fold up, or collapse, the device, putting a compressive load between the user's feet and torso. This force is similar to carrying a heavy backpack. The user then bends and extends his or her knees, replicating a weightlifting squat exercise. The applied load is precisely controlled by a computer, and can be programmed to simulate gravitation loads or any desired load prescription, such as free-weight squat exercise. It is even possible to perform eccentric exercises, or negatives, without the need for a spotter. Because the hip joints, as well as the spine and long leg bones, are in the applied load path, there is the potential to stimulate bone growth, countering the typical bone loss when astronauts return from extended duration space travel.

Beck, C. E.↗

Horizon: A Proposal for Large Aperture, Active Optics in Geosynchronous Orbit

In 1999, NASA's New Millennium Program called for proposals to validate new technology in high-earth orbit for the Earth Observing-3 (NMP EO3) mission to fly in 2003. In response, we proposed to test a large aperture, active optics telescope in geosynchronous orbit. This would flight-qualify new technologies for both Earth and Space science: 1) a future instrument with LANDSAT image resolution and radiometric quality watching continuously from geosynchronous station, and 2) the Next Generation Space Telescope (NGST) for deep space imaging. Six enabling technologies were to be flight-qualified: 1) a 3-meter, lightweight segmented primary mirror, 2) mirror actuators and mechanisms, 3) a deformable mirror, 4) coarse phasing techniques, 5) phase retrieval for wavefront control during stellar viewing, and 6) phase diversity for wavefront control during Earth viewing. Three enhancing technologies were to be flight- validated: 1) mirror deployment and latching mechanisms, 2) an advanced microcontroller, and 3) GPS at GEO. In particular, two wavefront sensing algorithms, phase retrieval by JPL and phase diversity by ERIM International, were to sense optical system alignment and focus errors, and to correct them using high-precision mirror mechanisms. Active corrections based on Earth scenes are challenging because phase diversity images must be collected from extended, dynamically changing scenes. In addition, an Earth-facing telescope in GEO orbit is subject to a powerful diurnal thermal and radiometric cycle not experienced by deep-space astronomy. The Horizon proposal was a bare-bones design for a lightweight large-aperture, active optical system that is a practical blend of science requirements, emerging technologies, budget constraints, launch vehicle considerations, orbital mechanics, optical hardware, phase-determination algorithms, communication strategy, computational burdens, and first-rate cooperation among earth and space scientists, engineers and managers. This manuscript presents excerpts from the Horizon proposal's sections that describe the Earth science requirements, the structural -thermal-optical design, the wavefront sensing and control, and the on-orbit validation.

Chesters, Dennis↗

Chicken (Gallus domesticus) inner ear afferents

Neurons from the vestibular (VG) and the statoacoustic (SAG) ganglion of the chick (Gallus domesticus) were evaluated histologically and morphometrically. Embryos at stages 34 (E8 days), 39 (E13 days) and 44 (E18 days) were sacrificed and temporal bones microdissected. Specimens were embedded in JB-4 methacrylate plastic, and stained with a mixture of 0.2% toluidine blue (TB) and 0.1% basic Fuschin in 25% ethanol or with a mixture of 2% TB and 1% paraphenylenediamine (PDA) for axon and myelin measurement study. Images of the VIIIth nerve were produced by a V150 (R) color imaging system and the contour of 200-300 neuronal bodies (perikarya) was traced directly on a video screen with a mouse in real time. The cross-sectional area of VG perikarya was 67.29 micrometers2 at stage 34 (E8), 128.46 micrometers2 at stage 39 (E13) and 275.85 micrometers2 at stage 44 (E18). The cross-sectional area of SAG perikarya was 62.44 micrometers2 at stage 34 (E8), 102.05 micrometers2 at stage 39 (E13) and 165.02 micrometers2 at stage 44 (E18). A significant cross-sectional area increase of the VG perikarya between stage 39 (E13) and stage 44 (E18) was determined. We randomly measured the cross-sectional area of myelin and axoplasm of hatchling afferent nerves, and found a correspondence between axoplasmic and myelin cross-sectional area in the utricular, saccular and semicircular canal nerve branches of the nerve. The results suggest that the period between stage 34 (E8) and 39 (E13) is a critical period for afferent neuronal development. Physiological and behavioral vestibular properties of developing and maturing hatchlings may change accordingly. The results compliment previous work by other investigators and provide valuable anatomical measures useful to correlate physiological data obtained from stimulation of the whole nerve or its parts.

NASA Discipline Neuroscience↗

Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction

This paper presents a new reconstruction algorithm for both single- and dual-energy computed tomography (CT) imaging. By incorporating the polychromatic characteristics of the X-ray beam into the reconstruction process, the algorithm is capable of eliminating beam hardening artifacts. The single energy version of the algorithm assumes that each voxel in the scan field can be expressed as a mixture of two known substances, for example, a mixture of trabecular bone and marrow, or a mixture of fat and flesh. These assumptions are easily satisfied in a quantitative computed tomography (QCT) setting. We have compared our algorithm to three commonly used single-energy correction techniques. Experimental results show that our algorithm is much more robust and accurate. We have also shown that QCT measurements obtained using our algorithm are five times more accurate than that from current QCT systems (using calibration). The dual-energy mode does not require any prior knowledge of the object in the scan field, and can be used to estimate the attenuation coefficient function of unknown materials. We have tested the dual-energy setup to obtain an accurate estimate for the attenuation coefficient function of K2 HPO4 solution.

NASA Center ARC↗

Artificial Intelligence for Accelerating Nuclear Applications, Science, and Technology

Artificial intelligence (AI) and machine learning (ML) methods have had significant impacts in science and technology in recent years. These methods for generating models from datasets or logic-based algorithms that emulate aspects of human performance can similarly accelerate the fields of nuclear applications, science, and technology toward the IAEA goals of contributing to peace, health, and prosperity. In order to accomplish advances with AI in general and ML in particular across these fields, IAEA can play a significant role by establishing, hosting and curating centralised resources, including databases, adhering to FAIR (findable, accessible, interoperable and reusable) principles and Open Science best practices, providing stewardship of data sharing, supporting training efforts and development of relevant workforces, as well as enabling connections among the scientific, technology, mathematics, AI and ethics communities. Many areas can benefit from the use of AI in the realm of nuclear applications. In human health, these areas include clinical research, epidemiology, nutrition, medical imaging, radiotherapy and education of health professionals. AI-based tools are also being used to facilitate different clinical tasks in imaging, computer-assisted diagnosis in mammography and lung cancer screening programmes, and dose prediction in nuclear medicine procedures. ML methods in particular may also increase the efficiency and accuracy of the analysis of computerised tomography and dual-energy absorptiometry scans for body composition and bone analysis. The application of AI methods to nuclear and related technologies in food and agriculture can lead to significant advances and improved efficiency in the optimisation of agricultural production, food product development, management of supply chains, food safety and food authenticity control. In the water and environmental sector, AI can help inform policies to mitigate the world’s water problems. The application of AI techniques to hydrology and environmental sciences is expected to improve patterns identification and enable model predictions under a changing climate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Some considerations in low-cost image processing on a university main frame: The Penn State (ORSER) experience

The ORSER System as implemented on the Penn State University Computation Center's IBM main frame is an exceptionally useful mechanism for instructing the present and future remote sensing community in the theory and practice of automated analysis of digitized data. From its beginning, the system was used as the hands-on back-bone of a graduate level "Multispectral Remote Sensing" one-term course taught annually in the School of Forest Resources. It was also used at the end of a senior-level undergraduate "Introduction to Remote Sensing" course, and in teaching a variety of short courses, ranging in length from a few days for small groups of remote sensing consultants with specific application interests, to a 2-week course oganized by NASA for regional and urban planners who had little or no previous exposure to remote sensing. Because of its modular construction, the ORSER is suitable for all classes of remote sensing users. Although in a beginning course only 6 to 10 of the programs are generally used, the researcher has a set of about 35 programs available for his analyses.

Turner, B. J.↗

Evaluation of 134 Ce/ 134 La as a PET Imaging Theranostic Pair for 225 Ac α-Radiotherapeutics

225 Ac-targeted α-radiotherapy is a promising approach to treating malignancies, including prostate cancer. However, α-emitting isotopes are difficult to image because of low administered activities and a low fraction of suitable γ-emissions. The in vivo generator 134 Ce/ 134 La has been proposed as a potential PET imaging surrogate for the therapeutic nuclides 225 Ac and 227 Th. In this report, we detail efficient radiolabeling methods using the 225 Ac-chelators DOTA and MACROPA. These methods were applied to radiolabeling of prostate cancer imaging agents, including PSMA-617 and MACROPA-PEG 4 -YS5, for evaluation of their in vivo pharmacokinetic characteristics and comparison to the corresponding 225 Ac analogs. Methods: Radiolabeling was performed by mixing DOTA/MACROPA chelates with 134 Ce/ 134 La in NH 4 OAc, pH 8.0, at room temperature, and radiochemical yields were monitored by radio–thin-layer chromatography. In vivo biodistributions of 134 Ce-DOTA/MACROPA.NH 2 complexes were assayed through dynamic small-animal PET/CT imaging and ex vivo biodistribution studies over 1 h in healthy C57BL/6 mice, compared with free 134 CeCl 3 . In vivo, preclinical imaging of 134 Ce-PSMA-617 and 134 Ce-MACROPA-PEG 4 -YS5 was performed on 22Rv1 tumor–bearing male nu/nu-mice. Ex vivo biodistribution was performed for 134 Ce/ 225 Ac-MACROPA-PEG 4 -YS5 conjugates. Results: 134 Ce-MACROPA.NH 2 demonstrated near-quantitative labeling with 1:1 ligand-to-metal ratios at room temperature, whereas a 10:1 ligand-to-metal ratio and elevated temperatures were required for DOTA. Rapid urinary excretion and low liver and bone uptake were seen for 134 Ce/ 225 Ac-DOTA/MACROPA. NH 2 conjugates in comparison to free 134 CeCl 3 confirmed high in vivo stability. An interesting observation during the radiolabeling of tumor-targeting vectors PSMA-617 and MACROPA-PEG 4 -YS5—that the daughter 134 La was expelled from the chelate after the decay of parent 134 Ce—was confirmed through radio–thin-layer chromatography and reverse-phase high-performance liquid chromatography. Both conjugates, 134 Ce-PSMA-617 and 134 Ce-MACROPA-PEG 4 -YS5, displayed tumor uptake in 22Rv1 tumor–bearing mice. The ex vivo biodistribution of 134 Ce-MACROPA.NH 2 , 134 Ce-DOTA and 134 Ce-MACROPA-PEG 4 -YS5 corroborated well with the respective 225 Ac-conjugates. Conclusion: These results demonstrate the PET imaging potential for 134 Ce/ 134 La-labeled small-molecule and antibody agents. The similar 225 Ac and 134 Ce/ 134 La-chemical and pharmacokinetic characteristics suggest that the 134 Ce/ 134 La pair may act as a PET imaging surrogate for 225 Ac-based radioligand therapies.

07 ISOTOPE AND RADIATION SOURCES↗

Intern Poster

Digital Image Correlation (DIC) is an optical technique that combines image registration and tracking methods for accurate two-dimensional and three-dimensional changes in images. DIC software can be used to track the contour, deformation, and strain of a sample. In the Advanced Test Reactor (ATR) at INL (Idaho National Laboratory) there exists a small working window of samples that can become irradiated. Hundreds of graphite disks called piggybacks have undergone this irradiation as part of the Advanced Reactor Technologies (ART) program. After irradiation, it is desirable to understand the change in tensile strength as a function of dose. Due to the limited space in the ATR, typical dog bone tensile tests reduce the number of graphite samples from hundreds to tens. However, there does exist an ASTM standard, D8289, which uses disc compression of graphite to estimate the tensile strength of the specimen with the Brazilian Disk test fixture. While only used as an estimate, which is typically off by a third, it is the purpose of this study to identify how to amend D8289 to remove the word "estimate" with the help of DIC.

36 MATERIALS SCIENCE↗

Training with the International Space Station interim resistive exercise device

A unique, interim elastomer-based resistive exercise device (iRED) is being used on the International Space Station. PURPOSE: This study characterized iRED training responses in a 1-g environment by: 1) determining whether 16 wk of high-intensity training with iRED produces increases in muscle strength and volume and bone mineral density (BMD), 2) comparing training responses with iRED to free weights, and 3) comparing iRED training responses at two training volumes. METHODS: Twenty-eight untrained men were assigned to four groups of seven subjects each: a no exercise control group (CON), an iRED group who trained with three sets/exercise (iRED3), a free-weight group (FW) who trained with three sets/exercise, and an iRED group who trained with six sets/exercise (iRED6). Training exercises included squat (SQ), heel raise (HR), and dead lift (DL) exercises, 3 d.wk(-1) for 16 wk. RESULTS: For CON, no changes occurred pre- to posttraining. For iRED3, increases (P< or =0.05) in one-repetition maximum (1-RM) strength (SQ 21 +/- 4%, HR 17 +/- 4%, DL 29 +/- 5%), leg lean mass (3.1 +/- 0.5%) by dual energy x-ray absorptiometry (DXA), and thigh (4.5 +/- 0.9%) and calf (5.9 +/- 0.7%) muscle volume (by magnetic resonance imaging) occurred after training with no changes in BMD (DXA). For FW, increases in 1-RM strength (SQ 22 +/- 5%, HR 24 +/- 3%, DL 41 +/- 7%), whole body (3.0 +/- 1.1%) and leg lean mass (5.4 +/- 1.2%), thigh (9.2 +/- 1.3%) and calf (4.2 +/- 1.0%) muscle volumes, and lumbar BMD (4.2 +/- 0.7%) occurred after training. For iRED6, all responses were similar to iRED3. CONCLUSION: High-intensity training with the iRED produced muscle responses similar to FW but was not effective in stimulating bone. Bed rest and spaceflight studies are needed to evaluate the effectiveness of the iRED to prevent microgravity deconditioning.

Weight-Bearing/physiology↗

Accurate Measurement of Bone Density with QCT

The objective of this study was to determine the accuracy of bone density measurement with a new OCT technology. A phantom was fabricated using two materials, a water-equivalent compound and hydroxyapatite (HA), combined in precise proportions (QRM GrnbH, Germany). The phantom was designed to have the approximate physical size and range in bone density as a human calcaneus, with regions of 0, 50, 100, 200, 400, and 800 mg/cc HA. The phantom was scanned at 80, 120 and 140 KVp with a GE CT/i HiSpeed Advantage scanner. A ring of highly attenuating material (polyvinyl chloride or teflon) was slipped over the phantom to alter the image by introducing non-axi-symmetric beam hardening. Images were corrected with a new OCT technology using an estimate of the effective X-ray beam spectrum to eliminate beam hardening artifacts. The algorithm computes the volume fraction of HA and water-equivalent matrix in each voxel. We found excellent agreement between expected and computed HA volume fractions. Results were insensitive to beam hardening ring material, HA concentration, and scan voltage settings. Data from all 3 voltages with a best fit linear regression are displays.

Cleek, Tammy M.↗

Technology Development to Support Human Health and Performance in Exploration Beyond Low Earth Orbit

In the course of defining the level of risks and mitigating the risks for exploration missions beyond low Earth orbit, NASA s Human Research Program (HRP) has identified the need for technology development in several areas. Long duration missions increase the risk of serious medical conditions due to limited options for return to Earth; no resupply; highly limited mass, power, volume; and communication delays. New space flight compatible medical capabilities required include: diagnostic imaging, oxygen concentrator, ventilator, laboratory analysis (saliva, blood, urine), kidney stone diagnosis & treatment, IV solution preparation and delivery. Maintenance of behavioral health in such an isolated, confined and extreme environment requires new sensory stimulation (e.g., virtual reality) technology. Unobtrusive monitoring of behavioral health and treatment methods are also required. Prolonged exposure to weightlessness deconditions bone, muscle, and the cardiovascular system. Novel exercise equipment or artificial gravity are necessary to prevent deconditioning. Monitoring of the degree of deconditioning is required to ensure that countermeasures are effective. New technologies are required in all the habitable volumes (e.g., suit, capsule, habitat, exploration vehicle, lander) to provide an adequate food system, and to meet human environmental standards for air, water, and surface contamination. Communication delays require the crew to be more autonomous. Onboard decision support tools that assist crew with real-time detection and diagnosis of vehicle and habitat operational anomalies will enable greater autonomy. Multi-use shield systems are required to provide shielding from solar particle events. The HRP is pursuing the development of these technologies in laboratories, flight analog environments and the ISS so that the human health and performance risks will be acceptable with the available resources.

Kundrot, C.E.↗

Linear Calibration of Radiographic Mineral Density Using Video-Digitizing Methods

Radiographic images can provide quantitative as well as qualitative information if they are subjected to densitometric analysis. Using modern video-digitizing techniques, such densitometry can be readily accomplished using relatively inexpensive computer systems. However, such analyses are made more difficult by the fact that the density values read from the radiograph have a complex, nonlinear relationship to bone mineral content. This article derives the relationship between these variables from the nature of the intermediate physical processes, and presents a simple mathematical method for obtaining a linear calibration function using a step wedge or other standard.

Martin, R. Bruce↗

Linear Calibration of Radiographic Mineral Density Using Video-Digitizing Methods

Radiographic images can provide quantitative as well as qualitative information if they are subjected to densitometric analysis. Using modem video-digitizing techniques, such densitometry can be readily accomplished using relatively inexpensive computer systems. However, such analyses are made more difficult by the fact that the density values read from the radiograph have a complex, nonlinear relationship to bone mineral content. This article derives the relationship between these variables from the nature of the intermediate physical processes, and presents a simple mathematical method for obtaining a linear calibration function using a step wedge or other standard.

Martin, R. Bruce↗

STS-95 Day 07 Highlights

On this seventh day of the STS-95 mission, the flight crew, Cmdr. Curtis L. Brown, Pilot Steven W. Lindsey, Mission Specialists Scott E. Parazynski, Stephen K. Robinson, and Pedro Duque, and Payload Specialists Chiaki Mukai and John H. Glenn, again test the Orbiter Space Vision System. OSVS uses special markings on Spartan and the shuttle cargo bay to provide an alignment aid for the arm's operator using shuttle television images. It will be used extensively on the next Space Shuttle flight in December as an aid in using the arm to join together the first two modules of the International Space Station. Specialist John Glenn will complete a daily back-pain questionnaire by as part of a study of how the muscle, intervertebral discs and bone marrow change after exposure to microgravity.

Source record↗

In-situ observations of cyclic deformation in an extruded Mg-2Nd-1Y-0.1Zr-0.1Ca alloy

In this study, the evolution of deformation mechanisms during cyclic loading in an extruded, solution-treated Mg–2Nd–1Y–0.1Zr–0.1Ca alloy was investigated using a combination of in-situ loading, scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), and focused ion beam (FIB) nanofabrication. The initial microstructure exhibited a random crystallographic texture with no preferred grain orientation. Flat, rectangular dog-bone specimens were subjected to load-controlled, fully reversed fatigue for 50 cycles, during which the same region was sequentially mapped to track microstructural changes. After 10 cycles of loading deformation twins were observed. During tensile reloading detwinning or narrowing of those twinned regions occurred. After 20 cycles, detwinning ceased and residual twins remained in the material. SEM imaging revealed numerous surface slip traces after cyclic loading. EBSD-assisted slip trace analysis identified the activation of prismatic and pyramidal < c+a> slip systems during low-cycle fatigue. Site-specific scanning transmission electron microscopy (STEM) further revealed that deformation was also accommodated by basal < a> slip and the dissociation of < c+a> dislocations. Center-of-symmetry (COS) analysis confirmed that the dissociation of < c+a> dislocations resulted in the formation of I₁ intrinsic stacking faults after cyclic loading. These findings provide new insights into the complex interplay of dislocation mechanisms governing fatigue deformation in rare-earth-containing Mg alloys.

Cyclic deformation↗