At least 145 records · Page 8

The energetics and dynamics of confinement in flexible frameworks and molecular confinement

This project is part of an ongoing and long-term collaboration among Alexandra Navrotsky (who moved recently from UC Davis to Arizona State University), Nancy Ross at Virginia Tech, and Brian Woodfield at Brigham Young University (BYU) on the thermodynamics and lattice dynamics of nanophase and porous materials. Navrotsky emphasizes energetics of formation and guest molecule sorption by ambient and high temperature calorimetry, Woodfield contributes cryogenic heat capacity measurements, and Ross uses inelastic neutron scattering, X-ray and neutron diffraction, and high pressure studies to probe lattice dynamics and phase transitions. Porous frameworks form the chemical and structural basis for critical technologies in separations, catalysis, nuclear waste containment and biomedical applications. Hundreds of zeolites and metal organic frameworks (MOFs) have been synthesized, and their ability to separate and store hydrogen, methane and carbon dioxide has been investigated both experimentally and theoretically. Nevertheless, a fundamental and systematic molecular-level understanding of the thermodynamic and structural factors governing the stability and guest-host interactions in these materials lags behind focused studies of specific systems. Because the guest molecules interact with each other and with the host framework, molecular confinement is a finely balanced and complex phenomenon. The ability of the guest molecules to bind and diffuse through the pores is determined by the nature of the host framework which, in turn, responds to the nature and concentration of guest molecules and to pressure and temperature. The work explores how framework flexibility, tailored by structure, composition, temperature and pressure, is a general phenomenon, similar in nature but variable in extent, in both zeolites and MOFs and is part of a free energy landscape in which framework-guest interactions, pressure, and temperature result in changes in framework geometry and, in some cases, phase transitions. These subtle and/or pronounced changes in lattice geometry, energetics, and dynamics can play a decisive role in confinement and in differentiating the binding of molecules of similar size.

36 MATERIALS SCIENCE↗

A Modular 512-Channel Neural Signal Acquisition ASIC for High-Density 4096 Channel Electrophysiology

The complexity of information processing in the brain requires the development of technologies that can provide spatial and temporal resolution by means of dense electrode arrays paired with high-channel-count signal acquisition electronics. In this work, we present an ultra-low noise modular 512-channel neural recording circuit that is scalable to up to 4096 simultaneously recording channels. The neural readout application-specific integrated circuit (ASIC) uses a dense 8.2 mm × 6.8 mm 2D layout to enable high-channel count, creating an ultra-light 350 mg flexible module. The module can be deployed on headstages for small animals like rodents and songbirds, and it can be integrated with a variety of electrode arrays. The chip was fabricated in a TSMC 0.18 µm 1.8 V CMOS technology and dissipates a total of 125 mW. Each DC-coupled channel features a gain and bandwidth programmable analog front-end along with 14 b analog-to-digital conversion at speeds up to 30 kS/s. Additionally, each front-end includes programmable electrode plating and electrode impedance measurement capability. We present both standalone and in vivo measurements results, demonstrating the readout of spikes and field potentials that are modulated by a sensory input.

47 OTHER INSTRUMENTATION↗

Noninvasive Detection, Tracking, and Characterization of Aerogel Implants Using Diagnostic Ultrasound

Medical implants are routinely tracked and monitored using different techniques, such as MRI, X-ray, and ultrasound. Due to the need for ionizing radiation, the two former methods pose a significant risk to tissue. Ultrasound imaging, however, is non-invasive and presents no known risk to human tissue. Aerogels are an emerging material with great potential in biomedical implants. While qualitative observation of ultrasound images by experts can already provide a lot of information about the implants and the surrounding structures, this paper describes the development and study of two simple B-Mode image analysis techniques based on attenuation measurements and echogenicity comparisons, which can further enhance the study of the biological tissues and implants, especially of different types of biocompatible aerogels.

36 MATERIALS SCIENCE↗

Terabit Wireless Communication Challenges

This presentation briefly discusses a research effort on Terabit Wireless communication systems for possible space applications. Recently, terahertz (THz) technology (300-3000 GHz frequency) has attracted a great deal of interest from academia and industry. This is due to a number of interesting features of THz waves, including the nearly unlimited bandwidths available, and the non-ionizing radiation nature which does not damage human tissues and DNA with minimum health threat. Also, as millimeter-wave communication systems mature, the focus of research is, naturally, moving to the THz range. Many scientists regard THz as the last great frontier of the electromagnetic spectrum, but finding new applications outside the traditional niches of radio astronomy, Earth and planetary remote sensing, and molecular spectroscopy particularly in biomedical imaging and wireless communications has been relatively slow. Radiologists find this area of study so attractive because t-rays are non-ionizing, which suggests no harm is done to tissue or DNA. They also offer the possibility of performing spectroscopic measurements over a very wide frequency range, and can even capture signatures from liquids and solids. According to Shannon theory, the broad bandwidth of the THz frequency bands can be used for terabit-per-second (Tb/s) wireless communication systems. This enables several new applications, such as cell phones with 360 degrees autostereoscopic displays, optic-fiber replacement, and wireless Tb/s file transferring. Although THz technology could satisfy the demand for an extremely high data rate, a number of technical challenges need to be overcome before its development. This presentation provides an overview the state-of-the- art in THz wireless communication and the technical challenges for an emerging application in Terabit wireless systems. The main issue for THz wave propagation is the high atmospheric attenuation, which is dominated by water vapor absorption in the THz frequency band. The technical challenges in design such a system and the techniques to overcome the challenges will be discussed in this presentation.

Hwu, Shian U.↗

Biomedical ultrasonoscope

An instrument with a single ultrasonic transducer probe and a linear array of transducer probes permitting three operator modes is described. An 'A' and an 'M' mode scanner were combined with a 'C' mode scanner and a single receiver is used. The 'C' scanner mode enables two-dimensional cross sections of the viewed organ. Video-produced markers enable measurement of the dimensions of the heart. COS/MOS integrated logic circuit components are used to minimize power consumption and permit battery operation.

Lee, R. D.↗

Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities

Electrodermal activity has long been used for mental activity monitoring by measuring skin conductance at specific locations, such as fingertips, with high sweat gland density. However, electrodermal activity has not been considered useful for physical activity monitoring, where large sweat volumes are generated, resulting in the accumulation of sweat at the skin–electrode interface and, thus, preventing further dynamic response to sweating events. Here we show that electrodermal activity can be used as a proxy for sweat loss measurement under both low and high physical activity levels. We use wearable sweat sensors that consist of water-permeable electrodes and microfluidic-based sweat analysers, and show that skin conductance is proportional to the instantaneous sweat loss. We demonstrate that sweat loss during exercise can be estimated by integrating skin conductance over time, which can be applied to assess the body hydration status of exercisers. From multisite measurements of skin conductance, we show that the wrist, forearm and upper arm are reflective of physical activity levels, whereas the finger is indicative of mental activity. Simultaneous measurement of two different sites selectively decouples mental and physical activities.

Biomedical engineering↗

Heavy ion observations by MARIE in cruise phase and Mars orbit

The charged particle spectrum for nuclei from protons to neon, (charge Z=10) was observed during the cruise phase and orbit around Mars by the MARIE charged particle spectrometer on the Odyssey spacecraft. The cruise data were taken between April 23, 2001 and mid-August 2001. The Mars orbit data were taken March 5, 2002 through May 2002 and are scheduled to continue until August 2004. Charge peaks are clearly separated for charges up to Z=10. Especially prominent are the carbon and oxygen peaks, with boron and nitrogen also clearly visible. Although heavy ions are much less abundant than protons in the cosmic ray environment, it is important to determine their abundances because their ionization energy losses (proportional to Z2) are far more dangerous to humans and to instruments. Thus the higher charged nuclei make a significant contribution to dose and dose equivalent received in space. Results of the charged particle spectrum measurements will be reported. c2003 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Center JSC↗

Wireless Frequency‐Multiplexed Acoustic Array‐Based Acoustofluidics

Abstract Acoustofluidics has shown great potential in enabling on‐chip technologies for driving liquid flows and manipulating particles and cells for engineering, chemical, and biomedical applications. To introduce on‐demand liquid sample processing and micro/nano‐object manipulation functions to wearable and embeddable electronics, wireless acoustofluidic chips are highly desired. This paper presents wireless acoustofluidic chips to generate acoustic waves carrying sufficient energy and achieve key acoustofluidic functions, including arranging particles and cells, generating fluid streaming, and enriching in‐droplet particles. To enable these functions, the wireless acoustofluidic chips leverage mechanisms, including inductive coupling‐based wireless power transfer (WPT), frequency multiplexing‐based control of multiple acoustic waves, and the resultant acoustic radiation and drag forces. For validation, the wirelessly generated acoustic waves are measured using laser vibrometry when different materials (e.g., bone, tissue, and hand) are inserted between the WPT transmitter and receiver. Moreover, the wireless acoustofluidic chips successfully arrange nanoparticles into different patterns, align cells into parallel pearl chains, generate streaming, and enrich in‐droplet microparticles. This research is anticipated to facilitate the development of embeddable wireless on‐chip flow generators, wearable sensors with liquid sample processing functions, and implantable devices with flow generation and acoustic stimulation abilities for engineering, veterinary, and biomedical applications.

Li, Jiali↗

Electrical impedance measurements in the arm and the leg during a thirty day bed rest study

The need to detect, follow, and understand the effects of gravity on body fluid distribution is a constant stimulus to the quest for new techniques in this area of research. One of these techniques is electrical bioimpedance spectroscopy (BIS). Although not new, this is a technique whose applications to biomedical research are fairly recent. What is new is the development of instrumentation that has made practical the use of impedance spectroscopy in the biomedical setting, particularly in studies involving human subjects. The purpose of this paper is to report impedance spectroscopy observations made on a subject who was submitted to bed rest for a period of thirty days. These observations were made as part of a study on muscle atrophy during a thirty day head down bed rest. Since bed rest studies are very costly in human and financial terms, and technically difficult to realize, we felt that even though the present study deals only with a single case it was worthy of reporting because it illustrates kinds of questions impedance spectroscopy may help to answer in microgravity research.

Cardus, David↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Collaborative research in cardiovascular dynamics and bone elasticity

A collaborative research program covering a variety of topics of biomechanics and biomedical engineering within the fields of cardiovascular dynamics, respiration, bone elasticity and vestibular physiology is described. The goals of the research were to promote: (1) a better understanding of the mechanical behavior of the circulatory system and its control mechanisms; (2) development of noninvasive methods of measuring the changes in the mechanical properties of blood vessels and other cardiovascular parameters in man; (3) application of these noninvasive methods to examine in man the physiological effects of environmental changes, including earth-simulated gravitational changes; and (4) development of in-flight methods for studying the events which lead to post-flight postural hypotension.

Source record↗

Is the bang worth the buck? A RAID performance study

Expecting a high data delivery rate as well as data protection, the Lister Hill National Center for Biomedical Communications procured a RAID system to house image files for image delivery applications. A study was undertaken to determine the configuration of the RAID system that would provide for the fastest retrieval of image files. Average retrieval times with single and with concurrent users were measured for several stripe widths and several numbers of disks for RAID levels 0, 0+1 and 5. These are compared to each other and to average retrieval times for non-RAID configurations of the same hardware. Although the study in ongoing, a few conclusions have emerged regarding the tradeoffs among the different configurations with respect to file retrieval speed and cost.

Hauser, Susan E.↗

Low Profile Tunable Dipole Antenna Using BST Varactors for Biomedical Applications

In this paper a 2.4 GHz low profile (lambda/47) tunable dipole antenna is evaluated in the presence of a human core model (HCM) body phantom. The antenna uses a frequency selective surface (FSS) with interdigital barium strontium titanate (BST) varactor-tuned unit cells and its performance is compared to a similar low profile antenna that uses an FSS with semiconductor varactor diodes. The measured data of the antenna demonstrate tunability from 2.2 GHz to 2.55 GHz in free space and impedance match improvement in the presence of a HCM at different distances. This antenna has smaller size, lower cost and less weight compared to the semiconductor varactor diode counterpart.

frequency selective surfaces↗

Toward Standardized Microscale Tensile Testing for Two‐Photon Polymerization‐Fabricated Materials in Liquid

Two-photon polymerization (TPP) enables the fabrication of intricate 3D microstructures with submicron precision, offering significant potential in biomedical applications like tissue engineering. In such applications, to print materials and structures with defined mechanics, it is crucial to understand how TPP printing parameters impact the material properties in a physiologically relevant liquid environment. Herein, an experimental approach utilizing microscale tensile testing (μTT) for the systematic measurement of TPP-fabricated microfibers submerged in liquid as a function of printing parameters is introduced. Using a diurethane dimethacrylate-based resin, the influence of printing parameters on microfiber geometry is first explored, demonstrating cross-sectional areas ranging from 1 to 36 μm 2 . Tensile testing reveals Young's moduli between 0.5 and 1.5 GPa and yield strengths from 10 to 60 MPa. The experimental data show an excellent fit with the Ogden hyperelastic polymer model, which enables a detailed analysis of how variations in writing speed, laser power, and printing path influence the mechanical properties of TPP microfibers. The μTT method is also showcased for evaluating multiple commercial resins and for performing cyclic loading experiments. Collectively, this study builds a foundation toward a standardized microscale tensile testing framework to characterize the mechanical properties of TPP printed structures.

mechanical characterization↗

Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications

The purpose of this study was to determine the effect of atomic oxygen (AO) exposure on the hydrophilicity of nine different polymers for biomedical applications. Atomic oxygen treatment can alter the chemistry and morphology of polymer surfaces, which may increase the adhesion and spreading of cells on Petri dishes and enhance implant growth. Therefore, nine different polymers were exposed to atomic oxygen and water-contact angle, or hydrophilicity, was measured after exposure. To determine whether hydrophilicity remains static after initial atomic oxygen exposure, or changes with higher fluence exposures, the contact angles between the polymer and water droplet placed on the polymer s surface were measured versus AO fluence. The polymers were exposed to atomic oxygen in a 100-W, 13.56-MHz radio frequency (RF) plasma asher, and the treatment was found to significantly alter the hydrophilicity of non-fluorinated polymers. Pristine samples were compared with samples that had been exposed to AO at various fluence levels. Minimum and maximum fluences for the ashing trials were set based on the effective AO erosion of a Kapton witness coupon in the asher. The time intervals for ashing were determined by finding the logarithmic values of the minimum and maximum fluences. The difference of these two values was divided by the desired number of intervals (ideally 10). The initial desired fluence was then multiplied by this result (2.37), as was each subsequent desired fluence. The flux in the asher was determined to be approximately 3.0 x 10(exp 15) atoms/sq cm/sec, and each polymer was exposed to a maximum fluence of 5.16 x 10(exp 20) atoms/sq cm.

deGroh, Kim↗

Imaging solvated oxygen atoms with a femtosecond laser

As a powerful oxidant, atomic oxygen (O) holds considerable promise for a variety of biomedical and industrial applications. However, the inability to quantify solvated oxygen atoms has prevented the determination of the fundamental parameters governing its behaviour in relevant aqueous environments. Here, we directly image ground-state oxygen atoms in water using femtosecond two-photon absorption laser-induced fluorescence. Measurements show that oxygen atoms persist for tens of microseconds in water, penetrating hundreds of micrometres into the liquid. This observed longevity has significant implications, suggesting a need to re-evaluate existing models of solvated atomic oxygen reactivity and transport. Beyond atomic oxygen, this technique is broadly applicable to other solvated atomic species of interest, including nitrogen (N) and hydrogen (H). This work establishes that radical atomic species can be quantified in liquid with ultrafast laser spectroscopy, providing the basis for the determination of key properties including reaction rates, chemical lifetimes, and Henry’s law constants.

Fluorescence spectroscopy↗

Studies Relating to EVA

In this session, Session JA1, the discussion focuses on the following topics: The Staged Decompression to the Hypobaric Atmosphere as a Prophylactic Measure Against Decompression Sickness During Repetitive EVA; A New Preoxygenation Procedure for Extravehicular Activity (EVA); Metabolic Assessments During Extra-Vehicular Activity; Evaluation of Safety of Hypobaric Decompressions and EVA From Positions of Probabilistic Theory; Fatty Acid Composition of Plasma Lipids and Erythrocyte Membranes During Simulation of Extravehicular Activity; Biomedical Studies Relating to Decompression Stress with Simulated EVA, Overview; The Joint Angle and Muscle Signature (JAMS) System - Current Uses and Future Applications; and Experimental Investigation of Cooperative Human-Robotic Roles in an EVA Work Site.

Source record↗