Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SI-PET-RAFT Polymerization via Electrodeposited Macroinitiator Thin Films: Toward Biomedical and Sensing Applications

Surface-initiated photoinduced electron transfer-reversible addition–fragmentation chain transfer (SI-PET-RAFT) polymerization has been preferentially used for preparing thin polymeric film coatings due to its simple execution under ambient conditions (e.g., in air) and visible light requirement. In this study, we demonstrate the preparation of polymer brushes by SI-PET-RAFT polymerization on a thin macroinitiator film electrodeposited on electrically conductive indium tin oxide and gold surfaces. An electrochemically active carbazole-containing chain transfer agent as macroinitiator was shown to be not only effective in mediating SI-PET-RAFT polymerization for various monomers but also capable of forming block copolymers. Additionally, the fabricated polymer brush films were able to encapsulate colloidal gold nanoparticles, thereby demonstrating potential use for biomedical and sensing applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchrotron Radiation for Biomedical Imaging

A synchrotron radiation (SR) X-ray source is an extraordinary tool for many applications because of the high intensity, the energy spectrum properties, the peculiar laminar beam geometry and the high degree of coherence. In the past years several experimental studies have proven the suitability of SR in the field of biomedical X-ray imaging and in diagnostic radiography. SR based X-ray imaging techniques to be mentioned are transvenous coronary angiography, bronchography, computed tomography and mammography that have been successfully implemented at different SR laboratories all around the world. Moreover, the high degree of the coherence of the synchrotron source allows the implementation of novel phase-sensitive X-ray imaging modalities. In contrast to conventional X-ray radiography, based on different X-ray absorption properties of details within an object, these phase-based techniques are capable of visualizing structures that have different scattering and refraction properties respect to the surrounding material. Their importance in medical imaging lies in the fact that the diagnosis of several diseases requires the detection of tiny structures, that consist of light elements in a similar background, and that produce very low X-ray absorption, but considerable phase shift in the wave front propagation. Thus, phase-sensitive techniques may improve dramatically the image quality and subsequently the accuracy in diagnosis offering highly enhanced contrast with dose comparable or even lower than required by conventional radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refracting Roentgen's rays: Propagation-based x-ray phase contrast for biomedical imaging

Absorption-contrast x-ray imaging serves to visualize the variation in x-ray attenuation within the volume of a given sample, whereas phase contrast allows one to visualize variations in x-ray refractive index. The former imaging mechanism has been well known and widely utilized since the time of Roentgen's Nobel prize winning work, whereas the latter mechanism--sought for, but not found, by Roentgen himself--has laid the foundation for a revolution in x-ray imaging which is the central topic of this review. We consider the physical imaging mechanisms underlying both absorption contrast and phase contrast, together with the associated inverse problem of how one may obtain quantitative two- or three-dimensional information regarding a sample, given one or more phase-contrast images of the same. Practical questions are considered, regarding optimized phase-contrast imaging geometries as a function of detector resolution, source size, x-ray spectrum, and dose. Experimental examples pertaining to biomedical applications are given, and prospects for the future outlined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A 24 keV liquid-metal-jet x-ray source for biomedical applications

We present a high-brightness 24-keV electron-impact microfocus x-ray source based on continuous operation of a heated liquid-indium/gallium-jet anode. The 30-70 W electron beam is magnetically focused onto the jet, producing a circular 7-13 {mu}m full width half maximum x-ray spot. The measured spectral brightness at the 24.2 keV In K{sub {alpha}} line is 3 x 10{sup 9} photons/(s x mm{sup 2}x mrad{sup 2}x 0.1% BW) at 30 W electron-beam power. The high photon energy compared to existing liquid-metal-jet sources increases the penetration depth and allows imaging of thicker samples. The applicability of the source in the biomedical field is demonstrated by high-resolution imaging of a mammography phantom and a phase-contrast angiography phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NSLS-II biomedical beamlines for micro-crystallography, FMX, and for highly automated crystallography, AMX: New opportunities for advanced data collection

We present the final design of the x-ray optics and experimental stations of two macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source-II. The microfocusing FMX beamline will deliver a flux of ∼5×10{sup 12} ph/s at 1 Å into a 1 – 20 µm spot, its flux density surpassing current MX beamlines by up to two orders of magnitude. It covers an energy range from 5 – 30 keV. The highly automated AMX beamline is optimized for high throughput, with beam sizes from 4 – 100 µm, an energy range of 5 – 18 keV and a flux at 1 Å of ∼10{sup 13} ph/s. A focus in designing the beamlines lay on achieving high beam stability, for example by implementing a horizontal bounce double crystal monochromator at FMX. A combination of compound refractive lenses and bimorph mirror optics at FMX supports rapid beam size changes. Central components of the in-house developed experimental stations are horizontal axis goniometers with a target sphere of confusion of 100 nm, piezo-slits for dynamic beam size changes during diffraction experiments, dedicated secondary goniometers for data collection from specimen in crystallization plates, and next generation pixel array detectors. FMX and AMX will support a broad range of biomedical structure determination methods from serial crystallography on micron-sized crystals, to structure determination of complexes in large unit cells, to rapid sample screening and room temperature data collection of crystals in trays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Big Biomedical data as the key resource for discovery science

Modern biomedical data collection is generating exponentially more data in a multitude of formats. This flood of complex data poses significant opportunities to discover and understand the critical interplay among such diverse domains as genomics, proteomics, metabolomics, and phenomics, including imaging, biometrics, and clinical data. The Big Data for Discovery Science Center is taking an “-ome to home” approach to discover linkages between these disparate data sources by mining existing databases of proteomic and genomic data, brain images, and clinical assessments. In support of this work, the authors developed new technological capabilities that make it easy for researchers to manage, aggregate, manipulate, integrate, and model large amounts of distributed data. Guided by biological domain expertise, the Center’s computational resources and software will reveal relationships and patterns, aiding researchers in identifying biomarkers for the most confounding conditions and diseases, such as Parkinson’s and Alzheimer’s.

Alzheimer's disease (ID)↗

High-Precision Zinc Isotopic Measurement of Certified Reference Materials Relevant to the Environmental, Earth, Planetary and Biomedical Sciences

The zinc (Zn) stable isotope system has emerged as a powerful tool for investigating natural and anthropogenic processes of interest to disciplines extending from the Earth and planetary sciences to biomedical research. In nature, Zn isotopes typically fractionate ( 66 Zn/ 64 Zn) within the range of –1 and +1 permil (‰), and however, analytical limitations restrict the application of the Zn isotope system. Specifically, there is a lack of well-characterised matrix-matched reference materials covering most Zn isotope applications that are essential for validating laboratory performance, particularly given the contamination prone nature of Zn. Furthermore, the increasing demand for analysis of size-limited materials and sample types displaying small, sub-permil level Zn isotope variations requires improvements in measurement procedures. To address these limitations, the δ 66 Zn values of two pure Zn solutions and eighteen reference materials including the previously uncharacterised RGM-2, BCR-279, DOLT-4, DOLT-5, NASS-7, SBC-1, SGR-1b, MESS-3 and HISS-1, and the understudied QLO-1, SDC-1, BCR-414, NASS-6 and COQ-1 materials are reported. Furthermore, a 70 Zn- 67 Zn double-spike design has been implemented that routinely achieves intermediate measurement precision better than ± 0.02‰. This represents at least a two-fold improvement when compared with other double-spike designs, providing a robust platform of δ 66 Zn values required for quality control procedures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical Note: Synchrotron-based high-energy x-ray phase sensitive microtomography for biomedical research

Purpose: Propagation-based phase-contrast CT (PPCT) utilizes highly sensitive phase-contrast technology applied to x-ray microtomography. Performing phase retrieval on the acquired angular projections can enhance image contrast and enable quantitative imaging. In this work, the authors demonstrate the validity and advantages of a novel technique for high-resolution PPCT by using the generalized phase-attenuation duality (PAD) method of phase retrieval. Methods: A high-resolution angular projection data set of a fish head specimen was acquired with a monochromatic 60-keV x-ray beam. In one approach, the projection data were directly used for tomographic reconstruction. In two other approaches, the projection data were preprocessed by phase retrieval based on either the linearized PAD method or the generalized PAD method. The reconstructed images from all three approaches were then compared in terms of tissue contrast-to-noise ratio and spatial resolution. Results: The authors’ experimental results demonstrated the validity of the PPCT technique based on the generalized PAD-based method. In addition, the results show that the authors’ technique is superior to the direct PPCT technique as well as the linearized PAD-based PPCT technique in terms of their relative capabilities for tissue discrimination and characterization. Conclusions: This novel PPCT technique demonstrates great potential for biomedical imaging, especially for applications that require high spatial resolution and limited radiation exposure.

60 APPLIED LIFE SCIENCES↗

3D printing of biomedically relevant polymer materials and biocompatibility

Research on polymer materials for additive manufacturing technology in biomedical applications is as promising as it is numerous, but biocompatibility of printable materials still remains a big challenge. Changes occurring during the 3D-printing processes itself may have adverse effects on the compatibility of the completed print. Furthermore, this prospective will put emphasis on the different additives and processes that can have a direct impact on biocompatibility during and after 3D printing of polymer materials.

36 MATERIALS SCIENCE↗

Multifunctional Biomedical Imaging in Physiological and Pathological Conditions Using a NIR-II Probe

Contrasted with imaging in the visible (400–650 nm) and near-infrared window I (NIR-I, 650–900 nm) regions, imaging in near-infrared window II (NIR-II, 1000–1700 nm) is a highly promising in vivo imaging modality with improved resolution and deeper tissue penetration. Here, a small molecule NIR-II dye,5,5'-(1H,5H-benzo[1,2-c:4,5-c'] bis[1,2,5]thiadiazole)-4,8-diyl)bis(N,N-bis(4-(3-((tert-butyldimethylsilyl)oxy)propyl)phenyl) thiophen-2-amine), is successfully encapsulated into phospholipid vesicles to prepare a probe CQS1000. The novel NIR-II probe is studied for in vivo multifunctional biological imaging. The results of this study indicate that the NIR-II vesicle CQS1000 can noninvasively and dynamically visualize and monitor many physiological and pathological conditions of circulatory systems, including lymphatic drainage and routing, angiogenesis of tumor, and vascular deformity such as arterial thrombus formation and ischemia with high spatial and temporal resolution. More importantly, by virtue of the favorable half-life of blood circulation of CQS1000, NIR-II imaging is capable of aiding precise resection of tumor such as osteosarcoma and accelerating the process of lymph node dissection to complete sentinel lymph node biopsy for better decision making during the tumor surgery. Overall, CQS1000 is a highly promising NIR-II probe for multifunctional biomedical imaging in physiological and pathological conditions, surpassing traditional NIR-I imaging modality and pathologic assessments for clinical diagnosis and treatment.

36 MATERIALS SCIENCE↗

Sol–Gel‐Based Advanced Porous Silica Materials for Biomedical Applications

Abstract Porous silica‐based materials have burgeoning applications ranging from fillers and additives, to adsorbents, catalysts, and recently therapeutic agents and vaccines in nanomedicine. The preponderance of these materials is made by sol–gel processing wherein soluble silica precursors are reacted to form amorphous networks composed of siloxane bonds. The facile sol–gel approach allows for an unlimited variety of binary tertiary and more complex chemical compositions including organic ligands and networks resulting in so‐called organic–inorganic hybrid materials. Here, a brief review of the recent progress in sol–gel‐derived silica materials prepared as particles, thin films, biosilica/silica bioreplicas (of molecules, cells and organisms), and their related preparation, properties, and bioapplications is provided. First, it highlights the recent achievements of mesoporous silica nanoparticles in biomedical applications, including therapeutic agent delivery, multimodal imaging and theranostics, and bone tissue engineering and repair. Second, the research in evaporation‐induced self‐assembly (EISA)‐based mesostructured silica thin films and cell‐directed EISA in bio/nano interfaces for various bioapplications, such as bioactive coatings, biosensing, and living cell immobilization, has been reviewed. Third, the pioneering work in biomimetic silicification/immobilization of biomolecules and bio‐organisms and silica bioreplication of complex bio‐organisms is summarized. Finally, it is concluded with personal perspectives on the directions of future work on this field.

Lei, Qi↗

Mapping of Texture and Phase Fractions in Heterogeneous Stress States during Multiaxial Loading of Biomedical Superelastic NiTi

Thermoelastic deformation mechanisms in polycrystalline biomedical-grade superelastic NiTi are spatially mapped using in situ neutron diffraction during multiaxial loading and heating. The trigonal R-phase is formed from the cubic phase during cooling to room temperature and subsequently deforms in compression, tension, and torsion. The resulting R-phase variant microstructure from the variant reorientation and detwinning processes are equivalent for the corresponding strain in tension and compression, and the variant microstructure is reversible by isothermal loading. The R-phase variant microstructure is consistent between uniaxial and torsional loading when the principal stress directions of the stress state are considered (for the crystallographic directions observed here). The variant microstructure evolution is tracked and the similarity in general behavior between uniaxial and torsional loading, in spite of the implicit heterogeneous stress state associated with torsional loading, pointed to the ability of the reversible thermoelastic transformation in NiTi to accommodate stress and strain mismatch with deformation. This ability of the R-phase, despite its limited variants, to accommodate stress and strain and satisfy strain incompatibility in addition to the existing internal stresses has significance for reducing irrecoverable deformation mechanisms during loading and cycling through the phase transformation.

36 MATERIALS SCIENCE↗

Structurally Defined Water‐Soluble Metallofullerene Derivatives towards Biomedical Applications

Abstract Endohedral metallofullerenes (EMFs) are excellent carriers of rare‐earth element (REE) ions in biomedical applications because they preclude the release of toxic metal ions. However, existing approaches to synthesize water‐soluble EMF derivatives yield mixtures that inhibit precise drug design. Here we report the synthesis of metallobuckytrio (MBT), a three‐buckyball system, as a modular platform to develop structurally defined water‐soluble EMF derivatives with ligands by choice. Demonstrated with PEG ligands, the resulting water‐soluble MBTs show superb biocompatibility. The Gd MBTs exhibit superior T 1 relaxivity than typical Gd complexes, potentially superseding current clinical MRI contrast agents in both safety and efficiency. The Lu MBTs generated reactive oxygen species upon light irradiation, showing promise as photosensitizers. With their modular nature to incorporate other ligands, we anticipate the MBT platform to open new paths towards bio‐specific REE drugs.

Li, Yanbang↗

Structurally Defined Water‐Soluble Metallofullerene Derivatives towards Biomedical Applications

Abstract Endohedral metallofullerenes (EMFs) are excellent carriers of rare‐earth element (REE) ions in biomedical applications because they preclude the release of toxic metal ions. However, existing approaches to synthesize water‐soluble EMF derivatives yield mixtures that inhibit precise drug design. Here we report the synthesis of metallobuckytrio (MBT), a three‐buckyball system, as a modular platform to develop structurally defined water‐soluble EMF derivatives with ligands by choice. Demonstrated with PEG ligands, the resulting water‐soluble MBTs show superb biocompatibility. The Gd MBTs exhibit superior T 1 relaxivity than typical Gd complexes, potentially superseding current clinical MRI contrast agents in both safety and efficiency. The Lu MBTs generated reactive oxygen species upon light irradiation, showing promise as photosensitizers. With their modular nature to incorporate other ligands, we anticipate the MBT platform to open new paths towards bio‐specific REE drugs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Laser-Induced Graphene Microfluidic Integrated Sensors (LIGMIS) for On-Site Biomedical and Environmental Monitoring

The convergence of microfluidic and electrochemical biosensor technologies offers significant potential for rapid, in-field diagnostics in biomedical and environmental applications. Traditional systems face challenges in cost, scalability, and operational complexity, especially in remote settings. Addressing these issues, laser-induced graphene microfluidic integrated sensors (LIGMIS) are presented as an innovative platform that integrates microfluidics and electrochemical sensors both comprised of laser-induced graphene. This study advances the LIGMIS concept by resolving issues of uneven fluid transport, increased hydrophobicity during storage, and sensor biofunctionalization challenges. Key innovations include Y-shaped reservoirs for consistent fluid flow, hydrophilic polyethyleneimine coatings to maintain wettability, and separable microfluidic and electrochemical components enabling isolated electrode nanoparticle metallization and biofunctionalization. Multiplexed electrochemical detection of the neonicotinoid imidacloprid and nitrate ions in environmental water samples yields detection limits of 707 nm and 10 -5.4 m with wide sensing ranges of 5–100 µm and 10 -5 –10 -1 m, respectively. Similarly, uric acid and calcium ions are detected in saliva, demonstrating detection limits of 217 nm and 10 -5.3 m with sensing ranges of 10–50 µm, and 10 -5 –10 -2.5 m, respectively. Overall, this biosensing demonstrates the capability of the LIGMIS platform for multiplexed detection in biologically complex solutions, with applications in environmental water quality monitoring and oral cancer screening.

environmental monitoring↗

Electrochemical Behavior of Biomedical Titanium Alloys Coated with Diamond Carbon in Hanks’ Solution

Biomedical implants in the knee and hip are frequent failures because of corrosion and stress on the joints. To solve this important problem, metal implants can be coated with diamond carbon, and this coating plays a critical role in providing an increased resistance to implants toward corrosion. In this study, we have employed diamond carbon coating over Ti-6Al-4V and Ti-13Nb-13Zr alloys using hot filament chemical vapor deposition method which is well-established coating process that significantly improves the resistance toward corrosion, wears and hardness. The diamond carbon-coated Ti-13Nb-13Zr alloy showed an increased microhardness in the range of 850 HV. Electrochemical impedance spectroscopy and polarization studies in SBF solution (simulated body fluid solution) were carried out to understand the in vitro behavior of uncoated as well as coated titanium alloys. The experimental results showed that the corrosion resistance of Ti-13Nb-13Zr alloy is relatively higher when compared with diamond carbon-coated Ti-6Al-4V alloys due to the presence of β phase in the Ti-13Nb-13Zr alloy. Electrochemical impedance results showed that the diamond carbon-coated alloys behave as an ideal capacitor in the body fluid solution. Moreover, the stability in mechanical properties during the corrosion process was maintained for diamond carbon-coated titanium alloys.

36 MATERIALS SCIENCE↗

Development of Alkoxide Precursors-Based Hybrid Coatings on Ti-6Al-4V Alloy for Biomedical Applications: Influence of pH of Sol

The Ti-6Al-4V alloy, widely used in biomedical applications, is associated with cytotoxic effects due to the release of aluminum and vanadium ions in the human body. One of the most effective ways to control the release of cytotoxic ions is through anti-corrosive coatings. Among them, the alkoxysilanes stand out for their good barrier properties and the absence of toxicity. Aiming to improve the clinical success rate of metallic implants, this study sets out to evaluate the influence of the pH of the sol on the physico-chemical, morphological, mechanical and electrochemical characteristics of hybrid films based on 3-(trimethoxysilylpropyl)methacrylate (MAP) and tetraethoxysilane (TEOS) applied to Ti-6Al-4V. The film was prepared by using the sol–gel method for pH values of 3, 4, and 5. The results indicated that maintaining the pH of the sol at 4 favors the hydrolysis rate of alkoxide precursors, which results in a uniform, dense and adherent film with excellent anti-corrosion performance.

36 MATERIALS SCIENCE↗

Influence of Thermal Treatment on the Microstructure, Mechanical Properties, and Corrosion Resistance of Newly Developed Ti20Nb13Zr Biomedical Alloy in a Simulated Body Environment

The effect of thermal treatments on the microstructure, hardness, and electrochemical performance in a simulated body fluid were studied for the newly developed (β + α) Ti20Nb13Zr alloy (TNZ) for biomedical applications. The alloy was heat-treated for 1 h at 900 °C and then cooled at different cooling rates. Then, the solution-treated samples were aged at 400, 500, or 600 °C for 5 h. The phase evolution and microstructure of the treated alloy were examined using XRD and SEM/EDX analysis. The mechanical properties were assessed using microindentation. The surface protection performance against corrosion was assessed by potentiodynamic polarization and electrochemical impedance spectroscopic analysis. The obtained results showed that the wide range of microstructure with varied volume fraction and morphology of β and α were obtained with different heat treatment conditions. The different phases’ sizes and distributions influenced the microstructure obtained during the heat treatment, thereby affecting the mechanical properties. The corrosion performance significantly altered with variations in the microstructure of the TNZ alloy as a result of the different thermal treatments. The heat treatment of TNZ conferred enhanced combination of mechanical and corrosion protection compared to that of the commercial Ti6Al4V alloy.

36 MATERIALS SCIENCE↗