Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biofilms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Testing molecules that disperse biofilms and biofouling and improve water recycling energy efficiency

In collaboration with Aequor, Inc, ABPDU researchers have evaluated a number of antibiofouling compounds for biofilm reduction potential in biomanufacturing applications. In addition to verifying their efficacy as dispersants, studies with bacteria, fungi, and algae indicate compatibility with canonical industrial host organisms. In addition, these molecules were found to significantly enhance growth rates of heterotrophic algae, indicating potential applications in algal cultivations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CompLaB v1.0: a scalable pore-scale model for flow, biogeochemistry, microbial metabolism, and biofilm dynamics

Abstract. Microbial activity and chemical reactions in porous media depend on the local conditions at the pore scale and can involve complex feedback with fluid flow and mass transport. We present a modeling framework that quantitatively accounts for the interactions between the bio(geo)chemical and physical processes and that can integrate genome-scale microbial metabolic information into a dynamically changing, spatially explicit representation of environmental conditions. The model couples a lattice Boltzmann implementation of Navier–Stokes (flow) and advection–diffusion-reaction (mass conservation) equations. Reaction formulations can include both kinetic rate expressions and flux balance analysis, thereby integrating reactive transport modeling and systems biology. We also show that the use of surrogate models such as neural network representations of in silico cell models can speed up computations significantly, facilitating applications to complex environmental systems. Parallelization enables simulations that resolve heterogeneity at multiple scales, and a cellular automaton module provides additional capabilities to simulate biofilm dynamics. The code thus constitutes a platform suitable for a range of environmental, engineering and – potentially – medical applications, in particular ones that involve the simulation of microbial dynamics.

58 GEOSCIENCES↗

Degradation of TCE using sequential anaerobic biofilm and aerobic immobilized bed reactor

Bacteria capable of degrading trichloroethylene (TCE) were isolated from contaminated wastewaters and soil sites. The aerobic cultures were identified as Pseudomonas aeruginosa (four species) and Pseudomonas fluorescens. The optimal conditions for the growth of aerobic cultures were determined. The minimal inhibitory concentration values of TCE for Pseudomonas sps. were also determined. The aerobic cells were immobilized in calcium alginate in the form of beads. Degradation of TCE by the anaerobic and dichloroethylene (DCE) by aerobic cultures was studied using dual reactors - anaerobic biofilm and aerobic immobilized bed reactor. The minimal mineral salt (MMS) medium saturated with TCE was pumped at the rate of 1 ml per hour into the anaerobic reactor. The MMS medium saturated with DCE and supplemented with xylenes and toluene (3 ppm each) was pumped at the rate of 1 ml per hour into the fluidized air-uplift-type reactor containing the immobilized aerobic cells. The concentrations of TCE and DCE and the metabolites formed during their degradation by the anaerobic and aerobic cultures were monitored by GC. The preliminary study suggests that the anaerobic and aerobic cultures of our isolates can degrade TCE and DCE.

Chapatwala, Kirit D.↗

Rapid direct methods for enumeration of specific, active bacteria in water and biofilms

Conventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between results obtained with the ChemScan and traditional plate counts of mixed natural bacterial populations in water. The continuing evolution of these methods will be valuable in the rapid and accurate analysis of environmental samples.

Review, Tutorial↗

Effects of culture conditions and biofilm formation on the iodine susceptibility of Legionella pneumophila

The susceptibility of Legionella pneumophila to iodination was studied with cultures grown in well water, on rich agar media, and attached to stainless-steel surfaces. Legionella pneumophila grown in water cultures in association with other microorganisms were less sensitive to disinfection by chlorine and iodine than were agar-passaged cultures. Differences in sensitivity to disinfection between water-cultured and agar-grown legionellae were determined by comparing C x T values (concentration in milligrams per litre multiplied by time in minutes to achieve 99% decrease in viability) and CM x T values (concentration in molarity). Iodine (1500x) gave a greater difference in CM x T values than did chlorine (68x). Iodine was 50 times more effective than chlorine when used with agar-grown cultures but was only twice as effective when tested against water-grown Legionella cultures. C x T x S values (C x T multiplied by percent survivors), which take into consideration the percent surviving bacteria, were used to compare sensitivities in very resistant populations, such as those in biofilms. Water cultures of legionellae associated with stainless-steel surfaces were 135 times more resistant to iodination than were unattached legionellae, and they were 210,000 times more resistant than were agar-grown cultures. These results indicate that the conditions under which legionellae are grown can dramatically affect their susceptibility to some disinfectants and must be considered when evaluating the efficacy of a disinfecting agent.

Non-NASA Center↗

Efficacy of Various Chemical Disinfectants on Biofilms Formed in Spacecraft Potable Water System Component

As the provision of potable water is critical for successful habitation of the International Space Station (ISS), life support systems were installed in December 2008 to recycle both humidity from the atmosphere and urine to conserve available water in the vehicle. Pre-consumption testing from the dispensing needle at the Potable Water Dispenser (PWD) indicated that bacterial concentrations exceeded the current ISS specifications of 50 colony forming units (CFU) per ml. Subsequent investigations revealed that a corrugated stainless steel flex hose upstream of the dispensing needle in the PWD was filled with non-sterile water and left at room temperature for over one month before launch. To simulate biofilm formation that was suspected in the flight system, sterile flex hoses were seeded with a consortium of bacterial isolates previously recovered from other ISS water systems, which included Ralstonia pickettii, Burkholderia multivorans, Caulobacter vibrioides., and Cupriavidus pauculus. After 5 days of incubation, these hoses were challenged with various chemical disinfectants including hydrogen peroxide, colloidal silver, and buffered pH solutions to determine the ability of the disinfectants to decrease and maintain bacterial concentrations below ISS specifications. Disinfection efficacy over time was measured by collecting daily heterotrophic plate counts following exposure to the disinfectants. A single flush with either 6% hydrogen peroxide solution or a mixture of 3% hydrogen peroxide and 400 ppb colloidal silver effectively reduced the bacterial concentrations to less than 1 CFU/ml for a period of up to 2 months. Testing results indicated that hydrogen peroxide and mixtures of hydrogen peroxide and colloidal silver have tremendous potential as alternative disinfectants for ISS water systems.

Wong, Willy↗

Investigation into Space Effects on Biofilm Growth Using Simulated Microgravity

Bacterial growth in liquid media while under microgravity conditions is not well understood. Trends such as a shortened lag phase, longer log phase, slower growth rate, and a higher final population concentration have been noted but the underlying cause remains unclear. Ground-based spaceflight analogs, or simulated microgravity devices, are often employed to achieve different attributes of weightlessness to study effects on bacterial growth. Though these technologies could isolate gravity’s role in various biological processes, they cannot replicate all its effects and underlying mechanisms. Hence, results could be misleading even if they are similar to spaceflight. At the single cell level, it is predicted that bacteria are less gravity-sensitive than larger species. The effects on their immediate environment, including the cell settlement and slower mass transfer of nutrients, might help explain the trends seen in liquid media microgravity studies. Therefore, experimental design factors must be carefully considered when selecting a simulated microgravity device for proper underlying mechanisms and interpretation of results. To verify if the simulated microgravity devices simulate the relevant microgravity conditions for bacterial growth, including the changes in cell settlement and mass transfer of nutrients, a high aspect ratio vessel (HARV) was used with dyes of different density in various simulated microgravity setups. The results will help inform the selection of the proper simulated microgravity device as well as interpretation of subsequent biofilm growth results.

Angie M. Diaz↗

Investigation into Stimulated Microgravity Techniques used to Study Biofilm Growth

Bacterial growth in liquid media in microgravity conditions is not well understood. Trends such as a shortened lag phase, longer log phase, slower growth rate, and a higher final population concentration have been noted but the underlying cause remains unclear. At the single cell level, it is predicted that bacteria are less gravity-sensitive than larger species. The effects on their immediate environment, including the lack of cell settlement and slower mass transfer of nutrients due to lack of density driven convection, could help explain the trends. Ground-based spaceflight analogs, or simulated microgravity devices, are often employed to achieve different attributes of weightlessness to study effects on bacterial growth. Though these technologies could isolate gravity’s role in various biological processes, they cannot replicate all its effects and underlying mechanisms. Hence, interpretation of results could be misleading, even if similar to spaceflight. In this study two common simulated microgravity devices were investigated to determine whether they could simulate relevant microgravity conditions for bacterial growth. A bioreactor, the high aspect ratio vessel (HARV), was used with dyes of different density mounted on a random positioning machine (RP machine) or a rotating wall vessel (RWV). The RP machine displayed higher mixing rates than the RWV. The RWV was further tested at different rotations per minute (RPM). The range to minimize effects of density driven convection (low speeds) or centrifugal forces (high speeds) was between a range of 15-20 RPM. These results will help inform the selection of simulated microgravity device as well as interpretation of subsequent biofilm growth results.

Angie M. Diaz↗

Commercialization of microcavity plasma devices and arrays: Systems for VUV photolithography and nanopatterning, disinfection of drinking water and air, and biofilm deactivation for medical therapeutics

Abstract A little more than two decades after the introduction of the first microcavity plasma devices, a growing body of commercial products based on the remarkable properties of these low‐temperature, atmospheric plasmas is now available. Following a brief review of early microplasma lamp development, this article describes microplasma‐based devices and systems currently being manufactured for applications in photolithography, photopatterning, and other nanofabrication processes, such as atomic layer deposition, spectroscopic identification and analysis of materials (including wide bandgap crystals), the disinfection of drinking water in off‐grid communities, deactivating COVID‐19 and other pathogens in air and on surfaces in public spaces, and vacuum ultraviolet lamps for driving atomic clocks. The microplasma‐based treatment of otitis media in the human ear will also be discussed.

42 ENGINEERING↗