A bi-prism interferometer for hard x-ray photons

Micro-fabricated bi-prisms have been used to create an interference pattern from an incident hard X-ray beam, and the intensity of the pattern probed with fluorescence from a 30 nm-thick metal film. Maximum fringe visibility exceeded 0.9 owing to the nano-sized probe and the choice of single-crystal prism material. A full near-field analysis is necessary to describe the fringe field intensities, and the transverse coherence lengths were extracted at APS beamline 8-ID-I. It is also shown that the maximum number of fringes is dependent only on the complex refractive index of the prism material.

47 OTHER INSTRUMENTATION↗

Novel silica stabilization method for the analysis of fine nanocrystals using coherent X-ray diffraction imaging

High-energy X-ray Bragg coherent diffraction imaging (BCDI) is a well established synchrotron-based technique used to quantitatively reconstruct the three-dimensional morphology and strain distribution in nanocrystals. The BCDI technique has become a powerful analytical tool for quantitative investigations of nanocrystals, nanotubes, nanorods and more recently biological systems. BCDI has however typically failed for fine nanocrystals in sub-100?nm size regimes ? a size routinely achievable by chemical synthesis ? despite the spatial resolution of the BCDI technique being 20?30?nm. The limitations of this technique arise from the movement of nanocrystals under illumination by the highly coherent beam, which prevents full diffraction data sets from being acquired. A solution is provided here to overcome this problem and extend the size limit of the BCDI technique, through the design of a novel stabilization method by embedding the fine nanocrystals into a silica matrix. Chemically synthesized FePt nanocrystals of maximum dimension 20?nm and AuPd nanocrystals in the size range 60?65?nm were investigated with BCDI measurement at beamline 34-ID-C of the APS, Argonne National Laboratory. Novel experimental methodologies to elucidate the presence of strain in fine nanocrystals are a necessary pre-requisite in order to better understand strain profiles in engineered nanocrystals for novel device development.

36 MATERIALS SCIENCE↗

Hard X-ray polarizer to enable simultaneous three-dimensional nanoscale imaging of magnetic structure and lattice strain

Recent progress in the development of dichroic Bragg coherent diffractive imaging, a new technique for simultaneous three-dimensional imaging of strain and magnetization at the nanoscale, is reported. This progress includes the installation of a diamond X-ray phase retarder at beamline 34-ID-C of the Advanced Photon Source. Here, the performance of the phase retarder for tuning X-ray polarization is demonstrated with temperature-dependent X-ray magnetic circular dichroism measurements on a gadolinium foil in transmission and on a Gd 5 Si 2 Ge 2 crystal in diffraction geometry with a partially coherent, focused X-ray beam. Feasibility tests for dichroic Bragg coherent diffractive imaging are presented. These tests include (1) using conventional Bragg coherent diffractive imaging to determine whether the phase retarder introduces aberrations using a nonmagnetic gold nanocrystal as a control sample, and (2) collecting coherent diffraction patterns of a magnetic Gd 5 Si 2 Ge 2 nanocrystal with left- and right-circularly polarized X-rays. Future applications of dichroic Bragg coherent diffractive imaging for the correlation of strain and lattice defects with magnetic ordering and inhomogeneities are considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed X-ray photon correlation spectroscopy data reduction using Hadoop MapReduce

Multi-speckle X-ray photon correlation spectroscopy (XPCS) is a powerful technique for characterizing the dynamic nature of complex materials over a range of time scales. XPCS has been successfully applied to study a wide range of systems. Recent developments in higher-frame-rate detectors, while aiding in the study of faster dynamical processes, creates large amounts of data that require parallel computational techniques to process in near real-time. Here, an implementation of the multi-tau and two-time autocorrelation algorithms using the Hadoop MapReduce framework for distributed computing is presented. In conclusion, the system scales well with regard to the increase in the data size, and has been serving the users of beamline 8-ID-I at the Advanced Photon Source for near real-time autocorrelations for the past five years.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Increased Throughput and Sensitivity of Synchrotron-Based Characterization for Photovoltaic Materials

Optimizing photovoltaic (PV) devices requires characterization and optimization across several length scales, from centimeters to nanometers. Synchrotron-based micro-X-ray fluorescence spectromicroscopy (μ-XRF) is a valuable link in the PV-related material and device characterization suite. μ-XRF maps of elemental distributions in PV materials have high spatial resolution and excellent sensitivity and can be measured on absorber materials and full devices. Recently, we implemented on-the-fly data collection (flyscan) at Beamline 2-ID-D at the Advanced Photon Source at Argonne National Laboratory, eliminating a 300 ms per-pixel overhead time. This faster scanning enables high-sensitivity (~10 14 atoms/cm 2 ), large-area (10 000s of μm 2 ), high-spatial resolution (<;200 nm scale) maps to be completed within a practical scanning time. We specifically show that when characterizing detrimental trace metal precipitate distributions in multicrystalline silicon wafers for PV, flyscans can increase the productivity of μ-XRF by an order of magnitude. Additionally, flyscan μ-XRF mapping enables relatively large-area correlative microscopy. As an example, we map the transition metal distribution in a 50 μm-diameter laser-fired contact of a silicon solar cell before and after lasing. As a result, while we focus on μ-XRF of mc-Si wafers for PV, our results apply broadly to synchrotron-based mapping of PV absorbers and devices.

14 SOLAR ENERGY↗

A hard x-ray KB-FZP microscope for tomography with sub-100-nm resolution

An instrument for high-resolution imaging and tomography has been built at the APS beamline 34 ID-C, Argonne National Laboratory. In-line phase contrast tomography can be performed with micrometer resolution. For imaging and tomography with resolution better than 100nm a hard X-ray microscope has been integrated to the instrument. It works with a Kirkpatrick-Baez (KB) mirror as condenser and a Fresnel-Zone plate (FZP) as an objective lens. 50 nm-features have been resolved in a Nickel structure operating the microscope at a photon energy of 9keV. Phase objects with negligible absorption contrast have been imaged. Tomography scans were performed on photonic crystals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of High Energy Resolution Fluorescence Detection Methods for Advanced Microscale X-ray Absorption Fine Structure Analysis of Critical Elements (Final Report)

This project is developing High-Energy Resolution Fluorescence Detection (HERFD) X-ray Absorption Fine-Structure Spectroscopy (XAFS) at the hard X-ray microprobe beamline at GSECARS beamline 13-ID-E, at the Advanced Photon Source at Argonne National Laboratory. This enhancement will improve sensitivity and spectral interpretation limitations of conventional XAFS which uses energy dispersive solid-state detectors (SSD) to measure the total fluorescence yield (TFY-XAFS). By using high-quality Si and Ge crystal analyzers to select X-ray fluorescence (XRF) from specific emission lines, background signals from other elements or X-ray scattering that can paralyze SSDs can be nearly eliminated, improving the sensitivity to the oxidation and chemical state of dilute species even though the solid angle of the analyzers is relatively small. Furthermore, by using analyzers of low-strain Si or Ge, the energy selection can be smaller than the natural widths of the core electron level. We are particularly interested in applying these enhanced sensitivities to Lanthanide series of rare-earth elements, which are typically at concentrations at or below 10 ppm, and where spectral overlaps with the 3rd row transition metals degrade sensitivity.

47 OTHER INSTRUMENTATION↗

High-Pressure Sound Velocity Measurements of Liquids Using In Situ Ultrasonic Techniques in a Multianvil Apparatus

Sound velocity and equation of state of liquids provide important constraints on the generation, presence, and transport of silicate and metallic melts in the Earth’s interior. Unlike their solid counterparts, these properties of liquids pose great technical challenges to high-pressure measurements and are poorly constrained. Here we present the technical developments that have been made at the GSECARS beamline 13-ID-D of the Advanced Photon Source for the past several years for determination of sound velocity of liquids using the ultrasonic techniques in a 1000-ton Kawai-type multianvil apparatus. Temperature of the sound velocity measurements has been extended to ~2400 K at 4 GPa and ~2000 K at 8 GPa to enable studies of liquids with very high melting temperatures, such as the silicate liquids.

58 GEOSCIENCES↗

High Resolution Mapping of Orientation and Strain Gradients in Metals by Synchrotron 3D X-ray Laue Microdiffraction

Synchrotron 3D X-ray Laue microdiffraction, available at beamline 34-ID-E at Advanced Photon Source in Argonne National Laboratory, is a powerful tool for 3D non-destructive mapping of local orientations and strains at sub-micron scale in the bulk. With this technique, it is possible to study local residual stresses developed during manufacturing or while in service due to interactions between, for example, different phases and/or grains with different orientations in materials containing multiple or single phase(s). Such information is essential for understanding mechanical properties and designing advanced materials, but is largely non-existent in the current generation of materials models. In the present paper, the principle and experimental set-up of the 3D microdiffraction are introduced, followed by a description of a method for quantification of the local plastic deformation based on high-angular-resolution orientation maps. The quantification of local residual stresses in two model materials, ductile cast iron (two phases) and partially recrystallized pure nickel (single phase), using 3D microdiffraction will then be presented. The results show that 3D microdiffraction is important for understanding the origin of local residual stresses and to relate them to the microstructural evolution. Finally, the limitations of the 3D microdiffraction on the current generation synchrotron source and new possibilities after the synchrotron upgrade are discussed.

36 MATERIALS SCIENCE↗

Quantifying X-Ray Fluorescence Data Using MAPS

Here, the quantification of X-ray fluorescence (XRF) microscopy maps by fitting the raw spectra to a known standard is crucial for evaluating chemical composition and elemental distribution within a material. Synchrotron-based XRF has become an integral characterization technique for a variety of research topics, particularly due to its non-destructive nature and its high sensitivity. Today, synchrotrons can acquire fluorescence data at spatial resolutions well below a micron, allowing for the evaluation of compositional variations at the nanoscale. Through proper quantification, it is then possible to obtain an in-depth, high-resolution understanding of elemental segregation, stoichiometric relationships, and clustering behavior. This article explains how to use the MAPS fitting software developed by Argonne National Laboratory for the quantification of full 2-D XRF maps. We use as an example results from a Cu(In,Ga)Se-2 solar cell, taken at the Advanced Photon Source beamline 2-ID-D at Argonne National Laboratory. We show the standard procedure for fitting raw data, demonstrate how to evaluate the quality of a fit and present the typical outputs generated by the program. In addition, we discuss in this manuscript certain software limitations and offer suggestions for how to further correct the data to be numerically accurate and representative of spatially resolved, elemental concentrations.

47 OTHER INSTRUMENTATION↗

Olivine Dissolution and Formation of Secondary phases in Ultramafic Soils

Introduction: Olivine has been proposed as an indicator for the duration of water-rock interaction within Martian rocks and sediments [1-3]. The use of olivine as a mineralogical indicator for past aqueous alteration on Mars requires interpretation of a complex combination of factors including pH, temperature, and composition [5,6]. Here, we examine the persistence of natural olivine within terrestrial ultramafic soils (Fe/Mg-rich, Al-poor) developing under different climatic conditions and the incipient dissolution of emplaced forsterite (Fo) and fayalite (Fa) surfaces to investigate environmental effects on incipient olivine dissolution, olivine persistence in soils, and formation of secondary phases. Methods: Field Sites. We examined olivine weathering and secondary material formation in ultramafic soils at 6 sites in the Klamath Mountains (KM) of northern California with a mean annual temperature of ~12.8℃ and precipitation of ~55.7-95.4 cm/year [7], and soil pH of ~6.5-7.3; 4 sites in the Tablelands (TB) of Newfoundland, Canada with a mean annual temperature of <3.9℃ and precipitation of ~120.0 cm/year [8], and soil pH of ~7.7; and at 3 sites at Pickhandle Gulch (PG), Nevada with a mean annual temperature of ~14.4℃ and precipitation of ~14.1 cm/year [7], and soil pH of ~8.5. Sampling sites span an age range of ~12.1-50+ kya in the Klamath Mountains [9,10] and ~13-30 kya in the Tablelands [11]. Pickhandle Gulch sites are undated. Parent Material and Soil Analyses. Polished thin sections of bulk soil prepared by Wagner Petrographic, Inc were carbon-coated and analyzed on a JEOL 2100 SEM in back-scattered electron mode in the EMIL lab at UNLV and at the 13-ID-E synchrotron beamline at Argonne National Laboratory using µXRF, µXRD, and XAS. Soil and parent material samples were powdered in a Fritsch pulverisette and analyzed by XRD and soil by VNIR. Soil preparation is further described in [12]. Disk Preparation, Burial, and Collection. Fo disks were cut from a column prepared via hot-pressing and Fa disks by sintering synthetic fayalite powder, see [13] for detail. Disks were polished to a 0.25-micron level with diamond grit. Disks were buried in 3 KM soils, 4 TB soils, and 3 PG soils, collected after exactly 365 days, and washed gently with 100% reagent grade ethanol to remove potential adhered soil material. Weathered disks and soil samples were stored in a -20℃ freezer until analysis. Unaltered control disks prepared identically to the buried disks were stored at -20℃ for the duration of the experiment. Disk Analyses. One Fo and Fa disk from each climate zone was analyzed on a variable pressure Zeiss Supra 40VP SEM at Northern Arizona University. A separate Fo and Fa disk from each climate zone was analyzed by XPS using a Physical Electronics VersaProbe II at the Penn State Univ. Materials Characterization Lab after a Na-dodecyl sulfate wash and ozonation to remove carbon contamination as in [14]. VNIR measurements were conducted at Johnson Space Center using an ASD FieldSpec3 under ambient lab conditions on a separate Fo and Fa disk from each climate zone. One separate Fo and Fa control sample was analyzed for each technique for comparison with weathered samples. XPS uncertainty was determined from 5 repeat measurements on controls. Results: Bedrock and Soil Results Olivine is present in the parent material in the KM and TB. Olivine is found in ~12.1 ka KM soils but is absent from all older soils, while persisting into the oldest (>20 ka) TB soil (Figure 1). In both locations, olivine is found as cores surrounded by a serpentine rind (Figure 2). VNIR spectra from the analyzed soils possess strong OH-associated spectral features at ~2.33 µm indicating the presence of Mg-rich phyllosilicates as well as ferric-oxide features at ~0.92 µm in the KM (Figure 3). Primary crystalline silicate grains mostly incorporate Fe2+, while poorly crystalline weathering rinds are best fit by ferric oxide XAS standards (Figure 4). µXRF also shows that Fe and Ni concentrate in weathering rinds and Cr remains within interior silicate grains (Figure 4). Buried Sample Results All Fo surfaces exhibited formation of dissolution features including shallow pitting not observed on controls. Dissolution features were most visually widespread on the KM disk (Figure 5). Leaching of Mg from KM and TB Fo disks was evident from <1.6 Mg/Si ratios measured by XPS (Figure 6). Fe-rich precipitates in SEM (Figure 5) and Fe presence in XPS scans (Figure 6) indicate Fe deposition onto KM and TB Fo disk surfaces. The appearance of a spectral feature at 0.55 µm in the VNIR spectra from the TB Fo suggests this Fe is ferric (Figure 7). The PG Fo appears least altered, with minimal formation of dissolution features in SEM (Figure 5), a Mg/Si ratio inconsistent with leaching (~2) (Figure 6), and VNIR spectra almost identical to the control sample. Analysis of Fa surfaces is ongoing. The higher temperatures and more acidic pH in the KM soils likely drive the faster dissolution of the Fo disks described above. While the TB soils experience greater precipitation than in the KM, the cooler temperatures and more basic soil pH facilitate observable but more limited alteration. The dry climate and basic soil pH at PG lead to minimal dissolution of the PG disk surfaces.

A D Feldman↗

In-Situ phase and texture characterization of solution deposited PZT thin films during crystallization.

Ferroelectric lead zirconate titanate (PZT) thin films are used for integrated capacitors, ferroelectric memory, and piezoelectric actuators. Solution deposition is routinely used to fabricate these thin films. During the solution deposition process, the precursor solutions are spin coated onto the substrate and then pyrolyzed to form an amorphous film. The amorphous film is then heated at a higher temperature (650-700 C) to crystallize the film into the desired perovskite phase. Phase purity is critical in achieving high ferroelectric properties. Moreover, due to the anisotropy in the structure and properties of PZT, it is desirable to control the texture obtained in these thin films. The heating rate during crystallization process is known to affect the sequence of phase evolution and texture obtained in these thin films. However, to date, a comprehensive understanding of how phase and texture evolution takes place is still lacking. To understand the effects of heating rate on phase and texture evolution, in-situ diffraction experiments during the crystallization of solution deposited PZT thin films were carried out at beamline 6-ID-B, Advanced Photon Source (APS). The high X-ray flux coupled with the sophisticated detectors available at the APS synchrotron source allow for in-situ characterization of phase and texture evolution at the high ramp rates that are commonly used during processing of PZT thin films. A PZT solution of nominal composition 52/48 (Zr/Ti) was spin coated onto a platinum-coated Si substrate (Pt//TiO{sub x}//SiO{sub 2}//Si). The films were crystallized using an infrared lamp, similar to a rapid thermal annealing furnace. The ramp rate was adjusted by controlling the voltage applied to the infrared lamp and increasing the voltage by a constant step with every acquisition. Four different ramp rates, ranging from {approx}1000 C/s to {approx}1 C/s, were investigated. The sample was aligned in grazing incidence to maximize the signal from the thin films. Successive diffraction patterns were acquired with a 1s acquisition time using a MAR SX-165 CCD detector during crystallization. The sample to detector distance and the tilt rotations of the detector were determined in Fit2D{copyright} by using Al{sub 2}O{sub 3} as the calibrant. These corrections were applied to the patterns when binning the data into radial (2{theta}) and azimuthal bins. The texture observed in the thin film was qualitatively analyzed by fitting the intensity peaks along the azimuthal direction with a gaussian profile function to obtain the integrated intensity of the peaks. Data analysis and peak fitting was done using the curve fitting toolbox in MATLAB{copyright}. A fluorite-type phase was observed to form before the perovskite phase for all ramp rates. PtxPb is a transient intermetallic formed due to the interaction of the thin film and the bottom electrode during crystallization. Ramp rate was observed to significantly affect the amount of PtxPb observed in the thin films during crystallization. Ramp rate was also observed to affect the final texture obtained in the thin films. These results will be discussed in the poster in view of the current understanding of these materials.

43 PARTICLE ACCELERATORS↗

X-ray Laue Diffraction Microscopy in 3D at the Advanced Photon Source

Studies of materials on mesoscopic length-scales require a penetrating structural probe with submicron point-to-point spatial resolution. The principle research activities at beamline 34-ID-E of the Advanced Photon Source (APS) involve development of exciting new micro-/nano-diffraction techniques for characterization and microscopy in support of both applied engineering and fundamental materials research. Taking advantage of the high brightness of the source, advanced focusing mirrors, a novel depth profiling technique, and high-speed area detectors, three-dimensional scanning Laue diffraction microscopy provides detailed local structural information of crystalline materials, such as crystallographic orientation, orientation gradients, and strain tensors. It is general and applicable to single-crystal, polycrystalline, composite, deformed, and functionally graded materials. Applications include 3D diffraction investigations for a diverse and growing user community with interests in materials deformation, electro-migration, recrystallization, fatigue, solid-solution precipitation, high-pressure environments, and condensed matter physics.

43 PARTICLE ACCELERATORS↗

Instrumentation for Structure Measurements on Highly Non-equilibrium Materials

Containerless techniques (levitation) completely eliminate contact with the sample. This unique sample environment allows deep supercooling of many liquids and avoids contamination of high temperature melts. Recent experiments at the APS high energy beamline 11 ID-C used aerodynamic levitation with laser beam heating and acoustic levitation with cryogenic cooling. By using these two methods, liquids were studied over much of the temperature range from -40 to +2500 C. This paper briefly describes the instrumentation and its use with an -Si area detector that allows fast, in-situ measurements. Use of the instruments is illustrated with examples of measurements on molten oxides and aqueous materials.

Weber, Richard↗

Hard x-ray induced synthesis of OF 2

We sought to demonstrate here that hard x-rays can initiate a sequence of acatalytic photochemical reactions with the aim of creating molecular mixtures (O 2 and F 2 ) and then observe the two species react to form OF 2 and with little introduction of heat. Two x-ray Raman scattering (XRS) studies of 1. KBF 4 and 2. a mixture of KBF 4 + KClO 4 pressurized to 3 GPa in a diamond anvil cell (DAC) at ambient temperature at the 16 ID-D undulator beamline at the Advanced Photon Source. The spectrometer collected photons with energy losses around 680 eV near the fluorine K-edge. Fluorine K-edge x-ray Raman spectroscopy demonstrated the clear formation of a new peak near 682 eV energy loss after some 8 hours of irradiation and detection of the KBF 4 /KClO 4 mixture which likely represents OF 2 produced from the following reaction: O 2 +2F 2 → 2OF 2 following irradiation of the mixture to release O 2 and F 2 , respectively, from each constituent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acoustic levitator for containerless measurements on low temperature liquids

A single-axis acoustic levitator was constructed and used to levitate liquid and solid drops at temperatures from -40 to +40 C. The levitator consisted of: (i) two acoustic transducers mounted on a rigid vertical support that was bolted to an optical breadboard, (ii) a acoustic power supply that controlled acoustic intensity, relative phase of the drive to the transducers, and could modulate the acoustic forces at frequencies up to 1kHz, (iii) a video camera, and (iv) a system for providing a stream of controlled temperature gas flow over the sample. The acoustic transducers were operated at their resonant frequency of ~ 22 kHz and could produce sound pressure levels up to 160 dB. The force applied by the acoustic field could be modulated using a frequency generator to excite oscillations in the sample. Sample temperature was controlled using a modified Cryostream Plus and measured using thermocouples and an infrared thermal imager. The levitator was installed at x-ray beamline 11 ID-C at the Advanced Photon Source and used to investigate the structure of supercooled liquids.

Acoustic levitation↗

The Inner Shell Spectroscopy beamline at NSLS-II: a facility for in situ and operando X-ray absorption spectroscopy for materials research

The Inner Shell Spectroscopy (ISS) beamline on the 8-ID station at the National Synchrotron Light Source II (NSLS-II), Upton, NY, USA, is a high-throughput X-ray absorption spectroscopy beamline designed for in situ, operando, and time-resolved material characterization using high monochromatic flux and scanning speed. This contribution discusses the technical specifications of the beamline in terms of optics, heat load management, monochromator motion control, and data acquisition and processing. Results of the beamline tests demonstrating the quality of the data obtainable on the instrument, possible energy scanning speeds, as well as long-term beamline stability are shown. The ability to directly control the monochromator trajectory to define the acquisition time for each spectral region is highlighted. Examples of studies performed on the beamline are presented. The paper is concluded with a brief outlook for future developments.

36 MATERIALS SCIENCE↗