Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bayesian model calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

131 records · Page 8

Evaluating Probabilistic Deep Learning Methods for Uncertainty Quantification of Precipitation Bias Correction

Climate models often exhibit biases in their precipitation predictions, particularly underestimating high-intensity events and overestimating low precipitation. Deep learning approaches offer promising solutions, but their epistemic uncertainty associated with a deep learning–based bias correction method has not previously been quantified for reliable downstream climate impact studies. While methods for capturing the epistemic uncertainty in deep learning frameworks exist, there is currently no consensus on the best method. In this work, we compare three uncertainty quantification (UQ) methods—Deep Ensembles (DEns), Monte Carlo Dropout (MCD), and Flipout—by assessing the reliability of their uncertainty estimates using standard measures such as sharpness and calibration. These UQ methods are applied to an existing deep learning precipitation bias correction model known as UFNet: a coupled U-Net and fully connected neural network. The methods utilized to assess the models’ uncertainties are 1) calibration, which ensures that the expected probabilities of the model align with reality and 2) sharpness, which is a measure of the precision of the model’s probabilistic predictions. Of the three UQ methods evaluated, the DEns and MCD methods demonstrated the best-calibrated performance (expected calibration error of 0.36 and 0.35, respectively), compared to Flipout (0.58). In contrast, Flipout had the sharpest predictions and the highest metric performance in bias correcting precipitation—especially for higher-order moments such as kurtosis with a spatial correlation of 72% compared to 32% and 55% spatial correlation for DEns and MCD, respectively. Of the three UQ methods, MCD was found to be the most suitable method for UQ purposes based on its calibration, sharpness, and computational requirements.

Bayesian methods↗

Chrono-Validation of Near-Real-Time Landslide Susceptibility Models via Plugin Statistical Simulations

The idea behind any validation scheme in landslide susceptibility studies is to test whether a model calibrated on a certain data can predict an unknown dataset of the same nature (landslide presences/absences and covariates). Almost the entirety of landslide susceptibility studies are validated by subsetting a single dataset into a training and test sets. This dataset usually corresponds either to event-specific or to historical inventories. Very rarely, a multi-temporal inventory is available and, in the few cases where this condition is met, the validation practices involve training a model on a specific landslide inventory, deriving a single predictive equation and validating it on a subsequent landslide inventory. This commonly leads landslide predictive studies, even those with a strong statistical rigor, to neglect the uncertainty estimation in their modeling scheme. In statistics, validation can also be performed via statistical simulations. This means that after fitting a given model, one can generate any number of predictive functions and test their predictive skills on any type and number of unknown datasets. In this work, we take a similar direction and we apply it to model and validate three separate co-seismic inventories, including an uncertainty estimation phase. We mapped these inventories within the same area in Indonesia, for three earthquakes occurred in 2012, 2017 and 2018. Specifically, we build three event-specific Bayesian Generalize Additive Models of the binomial family. From each model we then simulate 1000 predictive realizations over the remaining two inventories, by using a plug-in scheme where all the morphometric covariates are kept fixed and only the ground motion is replaced according to the prediction target. By doing so, we introduce a new analytical tool for near-real-time landslide predictive purposes, which is able to produce a probabilistic model which stands in between the definitions of susceptibility and hazard. In fact, our model is able to accurately estimate “where” and “when” - although not “how frequently” - landslide have occurred by featuring the multitemporal information of the trigger. In our findings, the simulations are quite similar to the fitted models; and the nine combinations we analyse produce excellent performance. This result confirms the assumption that “the past is the key to the future”, as we show that the relative contribution of each variable and their interactions in each probabilistic model remains practically the same across temporal replicates. This information is not trivial because it supports the routines implemented in global near-real-time applications.

Temporal validation↗

Bayesian Optimization of Catalysis with In-Context Learning

Large language models (LLMs) can perform accurate classification with zero or few examples through in-context learning (ICL), allowing the model to observe query-relevant examples at inference time and eliminating the need for additional weight updates to generalize beyond its original training data. We extend this capability to regression with uncertainty estimation using frozen LLMs (e.g., GPT-4o, Gemini), enabling Bayesian optimization (BO) in natural language without explicit model training or feature engineering. We apply this to materials discovery by representing materials as synthesis and testing procedures for use in natural language prompts. This Bayesian, design-first approach prioritizes optimization toward target material properties before detailed characterization, in contrast to conventional experimental workflows that often emphasize characterization of suboptimal materials. On benchmarks like aqueous solubility and oxidative coupling of methane (OCM), BO-ICL matches or outperforms Gaussian processes. In live experiments on the reverse water–gas shift (RWGS) reaction, BO-ICL identifies multimetallic catalysts that approach equilibrium CO yield within 6 and 10 iterations from a pool of 3,700 and 360,000 candidates, respectively. Our method redefines materials representation and accelerates discovery, with broad applications across catalysis, materials science, and AI.

Calibration↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Forest aboveground biomass estimation through integration of sentinel-2 and PALSAR-2 time series: assessing models trained on GEDI and field inventory benchmarks

Accurate and spatially explicit forest Aboveground Biomass (AGB) mapping through remote sensing is critical for quantifying terrestrial carbon stocks and informing effective forest management strategies. However, AGB estimation in dense forests with complex terrain remains challenging due to satellite sensor signal saturation problem (saturation issue occurs in high biomass forests), structural complexity, and limited ground truth for calibration. This study presents a novel framework that integrates multi-temporal Sentinel-2 optical imagery, ALOS PALSAR-2 Synthetic Aperture Radar (SAR) data, and topographic variables with explainable Machine Learning to map AGB across mountainous forests within subtropical and temperate oceanic climate zones of Mexico. We evaluate the effects of temporal granularity and sensor synergy by comparing multiple temporal inputs and sensor configurations (Sentinel-2, PALSAR-2, and their fusion), and assess model performance using two reference datasets: NASA GEDI LiDAR-derived biomass and Mexico’s National Forest and Soil Inventory (INFyS). Our results showed that models trained on INFyS consistently outperformed those trained on GEDI, highlighting limitations in GEDI’s reliability in biomass estimates within this study region. Furthermore, the integration of Sentinel-2 and PALSAR-2 provided improved predictions compared to single-sensor models, particularly when combined with temporally explicit yearly statistics. The best-performing model, which was trained on INFyS data, and considered both Sentinel-2 and PALSAR-2 yearly statistics, as well as topographic variables, achieved an R2 of 0.64, RMSE of 51.10 Mg/ha, and relative RMSE (rRMSE) of 58.69%. Explainable ML analysis identified Sentinel-2 spectral indices and topographic features as key predictors, while PALSAR-2 metrics provided complementary information, partially mitigating saturation effects in high-biomass areas. Specifically, integrating both sensors substantially improved AGB estimation in high biomass forest (≥200 Mg/ha), yielding 98% gains over optical-only model, with resulting estimates exceeding GEDI L4B by 29% and ESA-CCI-BIOMASS by 174%. Terrain-stratified analysis indicated close agreement with GEDI in low-slope areas, with increasing divergence as slope steepness increased, while estimates remained consistently higher than ESA-CCI-BIOMASS across all slope classes. The proposed approach advances multi-sensor fusion and temporal feature engineering for AGB mapping using open-access satellite datasets, providing a scalable and reproducible framework for annual biomass monitoring in topographically complex mountainous forests. The resulting 25 m resolution biomass product has the potential to provide spatially detailed information for forest monitoring and may support applications in carbon accounting and forest management.

54 ENVIRONMENTAL SCIENCES↗