Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Baltimore”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Mobility Pattern Analysis for Power Restoration Activities Using Geo-Tagged Tweets

In this study, we analyzed mobility patterns of at-risk populations affected by an extreme event using geotagged tweets to geo-target power restoration efforts. Unlike other studies that have used tweets to facilitate emergency management activities, we used 1.5 million geotagged tweets generated during Hurricane Sandy (2012) to determine the mobility patterns and geospatial distribution of impacted populations who experienced power outage before, during and after the hurricane. We implemented a three-step analytical framework to: (i) analyze tweet contents with visual methods, including dendrograms, word clouds to identify common keywords pertaining to power outage; (ii) identify target users whose tweets contained information about power outages; and (iii) create a user-tweet locations matrix and an origin-destination matrix to examine clusters of target users and their mobility patterns. Preliminary results indicate that potential clusters were present in and around New York city, Philadelphia, Washington D.C. and Baltimore, which were used as potential evacuation destination cities after hurricane Sandy. The travel pattern and destination information can be used to (i) mobilize restoration efforts by utility companies and (ii) address resource allocation needs both in impacted and destination cities. Future work will focus on analyzing potential destinations for different origins and travel-time to identify evacuation routing patterns.

Kar, Bandana↗

2011-2012 Maryland Route 200 Travel Survey

The 2011-2012 Maryland Route 200 Travel Survey collected in-vehicle global positioning system (GPS) data to investigate the use of Maryland Route 200, also known as the Intercounty Connector. The University of Maryland conducted the survey between October 2011 and February 2012 in Washington, D.C., and Baltimore, Maryland. Its goal was to increase understanding of the potential use of Maryland Route 200, a tolled freeway connecting Maryland's Montgomery County and Prince George's County. Dedicated in-vehicle GPS devices were installed in 260 vehicles to record location information every 60 seconds if movement was detected. Survey subjects partook in an initial participation form as well as a recall survey, providing social demographic information and a one-day travel diary.

1Hz data↗

Potential Energy Savings Due to Phase Change Material in a Building Wall Assembly: An Examination of Two Climates

Phase change material (PCM), placed in an exterior wall, alters the temperature profile within the wall and thus influences the heat transport through the wall. This may reduce the net energy transport through the wall via interactions with diurnal temperature swings in the external environment or reduce the electricity needed to meet the net load through the wall by shifting the time of the peak load to a time when the cooling system operates more efficiently. This study covers a broad range of parameters that can influence the effectiveness of such a merged thermal storage-thermal insulation system. These parameters included climate, PCM location within the wall, amount of PCM, midpoint of the PCM melting and freezing range relative to the indoor setpoint temperature, temperature range over which phase change occurs, and the wall orientation. Two climates are investigated using finite difference and optimization analyses: Phoenix and Baltimore, with two utility rate schedules. Although potential savings for a PCM with optimized properties were greater when the PCM was concentrated near the inside wall surface, other considerations described here lead to a recommendation for a full-thickness application. An examination of the temperature distribution within the walls also revealed the potential for this system to reduce the amount of energy transported through the wall framing. Finally, economic benefits can exceed energy savings when time-of-day utility rates are in effect, reflecting the value of peak load reductions for the utility grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Identification and Characterization of Soluble Factors Involved in Delayed Effects of Low Dose Radiation (Final Report)

This is a 'glue grant' that was part of a DOE Low Dose project entitled 'Identification and Characterization of Soluble Factors Involved in Delayed Effects of Low Dose Radiation'. This collaborative program has involved Drs. David L. Springer from Pacific Northwest National Laboratory (PNNL), John H. Miller from Washington State University, Tri-cities (WSU) and William F. Morgan then from the University of Maryland, Baltimore (UMB). In July 2008, Dr. Morgan moved to PNNL and Dr. Janet E. Baulch became PI for this project at University of Maryland. In November of 2008, a one year extension with no new funds was requested to complete the proteomic analyses. The project stemmed from studies in the Morgan laboratory demonstrating that genomically unstable cells secret a soluble factor or factors into the culture medium, that cause cytogenetic aberrations and apoptosis in normal parental GM10115 cells. The purpose of this project was to identify the death inducing effect (DIE) factor or factors, estimate their relative abundance, identify the cell signaling pathways involved and finally recapitulate DIE in normal cells by exogenous manipulation of putative DIE factors in culture medium. As reported in detail in the previous progress report, analysis of culture medium from the parental cell line, and stable and unstable clones demonstrated inconsistent proteomic profiles as relate to candidate DIE factors. While the proposed proteomic analyses did not provide information that would allow DIE factors to be identified, the analyses provided another important set of observations. Proteomic analysis suggested that proteins associated with the cellular response to oxidative stress and mitochondrial function were elevated in the medium from unstable clones in a manner consistent with mitochondrial dysfunction. These findings correlate with previous studies of these clones that demonstrated functional differences between the mitochondria of stable and unstable clones. These mitochondrial abnormalities in the unstable clones contributes to oxidative stress.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Define and Quantify the Physics of Air Flow, Pressure Drop and Aerosol Collection in Nuclear Grade HEPA Filters

Objective: Develop a set of peer-review and verified analytical methods to adjust HEPA filter performance to different flow rates, temperatures and altitudes. Experimental testing will measure HEPA filter flow rate, pressure drop and efficiency to verify the analytical approach. Nuclear facilities utilize HEPA (High Efficiency Particulate Air) filters to purify air flow for workspace ventilation. However, the ASME AG-1 technical standard (Code on Nuclear Air and Gas Treatment) does not adequately describe air flow measurement units for HEPA filter systems. Specifically, the AG-1 standard does not differentiate between volumetric air flow in ACFM (actual cubic feet per minute)compared to mass flow measured in SCFM (standard cubic feet per minute). More importantly, the AG-1 standard has an overall deficiency for using HEPA filter devices at different air flow rates, temperatures, and altitudes. Technical Approach: The collection efficiency and pressure drops of 18 different HEPA filters will be measured over a range of flow rates, temperatures and altitudes. The experimental results will be compared to analytical scoping calculations. Three manufacturers have allocated six HEPA filters each for this effort. The 18 filters will be tested at two different flow rates, two different temperatures and two different altitudes. The 36 total tests will be conducted at two different facilities: the ATI Test facilities (Baltimore MD) and the Los Alamos National Laboratory (Los Alamos NM). The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally designed to evaluate small air samplers. In 2010, modifications were started to convert the wind tunnel for HEPA filter testing. (Extensive changes were necessary for the required aerosol generators, HEPA test fixtures, temperature control devices and measurement capabilities.) To this date, none of these modification activities have been funded through a specific DOE or NNSA program. This is expected to require six months of time, after receipt of funding. Benefits: US DOE facilities that use HEPA filters will benefit from access to the new operational measurement methods. Uncertainty and guesswork will be removed from HEPA filter operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Biomass Program 2007 Program Peer Review - Full Report

This document summarizes the comments provided by the peer reviewers at the U.S. Department of Energy (DOE) Biomass Program’s Peer Review meeting, held on November 14-15, 2007 in Baltimore, MD and Platform Reviews conducted over the summer of 2007. The Platform Reviews provide evaluations of the Program’s projects in applied research, development, and demonstration.

09 BIOMASS FUELS↗

Biomass Program 2007 Program Peer Review - Program Summary Section

This document summarizes the comments provided by the peer reviewers at the U.S. Department of Energy (DOE) Biomass Program’s Peer Review meeting, held on November 14-15, 2007 in Baltimore, MD and Platform Reviews conducted over the summer of 2007. The Platform Reviews provide evaluations of the Program’s projects in applied research, development, and demonstration.

09 BIOMASS FUELS↗

Biomass Program 2007 Program Peer Review - Feedstock Platform Summary

This document discloses the comments provided by a review panel at the U.S. Department of Energy Office of the Biomass Program Peer Review held on November 15-16, 2007 in Baltimore, MD and the Feedstock Platform Portfolio Peer Review held on August 21st through 23rd in Washington D.C.

09 BIOMASS FUELS↗

Airborne Open Polar/Imaging Nephelometer for Ice Particles in Cirrus Clouds and Aerosols Field Campaign Report

The Open Imaging Nephelometer (O-I-Neph) instrument is an adaptation of a proven laboratory instrument built and tested at the University of Maryland, Baltimore County (UMBC), the Polarized Imaging Nephelometer (PI-Neph). The instrument design of both imaging nephelometers uses a narrow-beam laser source and a wide-field-of-view imaging camera to capture the entire scattering-phase function in one image, quasi-instantaneously.

54 ENVIRONMENTAL SCIENCES↗

Mass Casualty Chemical Incident Operational Framework, Assessment and Best Practices

Emergency response agencies in most US communities are organized, sized, and equipped to manage those emergencies normally expected. Hospitals in particular do not typically have significant excess capacity to handle massive numbers of casualties, as hospital space is an expensive luxury if not needed. Unfortunately this means that in the event of a mass casualty chemical incident the emergency response system will be overwhelmed. This document provides a self-assessment means for emergency managers to examine their response system and identify shortfalls. It also includes lessons from a detailed analysis of five communities: Baltimore, Boise, Houston, Nassau County, and New Orleans. These lessons provide a list of potential critical decisions to allow for pre-planning and a library of best practices that may be helpful in reducing casualties in the event of an incident.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Smart Ventilation Control Algorithms for Humidity Control in High-Performance Homes in Humid U.S. Climates

Past field research and simulation studies have shown that high performance homes experience elevated indoor humidity levels for substantial portions of the year in humid climates. This is largely the result of lower sensible cooling loads, which reduces the moisture removed by the cooling system. These elevated humidity levels lead to concerns about occupant comfort, health and building durability. Use of mechanical ventilation at rates specified in ASHRAE Standard 62.2-2013 are often cited as an additional contributor to humidity problems in these homes. Past research has explored solutions, including supplemental dehumidification, cooling system operational enhancements and ventilation system design (e.g., ERV, supply, exhaust, etc.). This project’s goal is to develop and demonstrate (through simulations) smart ventilation strategies that can contribute to humidity control in high performance homes. These strategies must maintain IAQ via equivalence with ASHRAE Standard 62.2-2013. To be acceptable they must not result in excessive energy use. Smart controls will be compared with dehumidifier energy and moisture performance. This work explores the development and performance of smart algorithms for control of mechanical ventilation systems, with the objective of reducing high humidity in modern high performance residences. Simulations of DOE Zero-Energy Ready homes were performed using the REGCAP simulation tool. Control strategies were developed and tested using the Residential Integrated Ventilation (RIVEC) controller, which tracks pollutant exposure in real-time and controls ventilation to provide an equivalent exposure on an annual basis to homes meeting ASHRAE 62.2-2013. RIVEC is used to increase or decrease the real-time ventilation rate to reduce moisture transport into the home or increase moisture removal. This approach was implemented for no-, one- and two-sensor strategies, paired with a variety of control approaches in six humid climates (Miami, Orlando, Houston, Charleston, Memphis and Baltimore). The control options were compared to a baseline system that supplies outdoor air to a central forced air cooling (and heating) system (CFIS) that is often used in hot humid climates. Simulations were performed with CFIS ventilation systems operating on a 33% duty-cycle, consistent with 62.2-2013. The CFIS outside airflow rates were set to 0%, 50% and 100% of 62.2-2013 requirements to explore effects of ventilation rate on indoor high humidity. These simulations were performed with and without a dehumidifier in the model. Ten control algorithms were developed and tested. Analysis of outdoor humidity patterns facilitated smart control development. It was found that outdoor humidity varies most strongly seasonally—by month of the year—and that all locations follow the similar pattern of much higher humidity during summer. Daily and hourly variations in outdoor humidity were found to be progressively smaller than the monthly seasonal variation. Patterns in hourly humidity are driven by diurnal daily patterns, so they were predictable but small, and were unlikely to provide much control benefit. Variation in outdoor humidity between days was larger, but unpredictable, except by much more complex climate models. We determined that no-sensor strategies might be able to take advantage of seasonal patterns in humidity, but that real-time smart controls were required to capture variation between days. Sensor-based approaches are also required to respond dynamically to indoor conditions and variations not considered in our analysis. All smart controls face trade-offs between sensor accuracy, cost, complexity and robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental and numerical evaluations of the energy savings potential of thermally anisotropic composites

Previous numerical studies conducted in FY 17 showed that the application of thermally anisotropic composites (TACs) coupled with a heat sink/source can re-direct and reduce unwanted heat flows through exterior building walls, with associated reductions in envelope-generated heating and cooling loads in buildings. The numerical analyses included two-dimensional finite element models (FEM) of wall assemblies and whole-building modeling to estimate the annual reductions in wall-generated heating and cooling loads, and associated energy consumption. The FY17 study used combined FEM and EnergyPlus (E+) simulations of a typical two-story, single-family DOE prototype residential building model.1 We studied performance of several configurations of walls containing exterior continuous insulation and thermally anisotropic composites on the wall exterior. The study showed that annual energy cost savings of up to $270 are possible under Phoenix and Baltimore weather conditions, by retrofitting a baseline wall with an anisotropic composite. In the cases considered, the TAC consisted of three layers of aluminum foil-faced foam boards. In general, it was found that the anisotropic composites were effective in reducing cooling loads; more investigation on heating loads is needed. During FY 18, ORNL performed a series of laboratory tests of anisotropic composites and appropriate heat sink/source, validated the FEMs used for the FY17 numerical study using experimental data, and revisited the whole-building modeling. Wall prototypes were created and tested in ORNL’s large scale climate simulator (LSCS) under variable conditions approximating summer and winter time periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Information Theoretic Measures for Visual Analytics: The Silver Ticket?

In the context of text-based analysis workflows, we propose that an effective analytic tool facilitates triage by a) enabling users to identify and set aside irrelevant content (i.e., reduce the complexity of information in a dataset) and b) develop a working mental model of which items are most relevant to the question at hand. This LDRD funded research developed a dataset that is enabling this team to evaluate propose normalized compression distance (NCD) as a task, user, and context-insensitive measure of categorization outcomes (Shannon entropy is reduced as order is imposed). Effective analytics tools help people impose order, reducing complexity in measurable ways. Our concept and research was documented in a paper accepted to the ACM conference "Beyond Time and Error: Novel Methods in Information Visualization Evaluation", part of the IEEE VisWeek Conference, Baltimore, MD, October 16-21, 2016. The paper is included as an appendix to this report.

97 MATHEMATICS AND COMPUTING↗