At least 145 records · Page 8

Toughened polyester composites containing polyester matrix and droplets of high boiling liquid therein

A toughened polyester composite comprising: (i) a polyester matrix and (ii) droplets of a high boiling point liquid having a boiling point of at least 140° C. dispersed in said polyester matrix, wherein the high boiling point liquid is present in an amount of 0.1-10 wt % by weight of the toughened polyester composite, and wherein the composite may further include: (iii) a modifier selected from polycarboxylic, polyol, and polyamine compounds, wherein the modifier is present in an amount of 0.1-10 wt % by weight of the toughened polyester composite. Methods for producing the polyester composite are also described.

Ozcan, Soydan↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Subcooled and saturated water flow boiling pressure drop in small diameter helical coils at low pressure

Experimental pressure drop results on boiling water flow through three helical coils of tube inner diameter of 4.03 mm and 4.98 mm and coil diameter to tube diameter ratio of 26.1, 64.1 and 93.3 are presented. Both subcooled and saturated flow boiling are investigated, covering operating pressures from 120 to 660 kPa, mass fluxes from 290 to 690 kg m{sup -2} s{sup -1} and heat fluxes from 50 to 440 kW m{sup -2}. Existing correlations for subcooled flow pressure drop are found not capable to fit the present subcooled database, while the measurements in saturated flow conditions are successfully reproduced by existing correlations for both straight and coiled pipe two-phase flow. The experimental database is included in tabular form. (author)

42 ENGINEERING↗

Experimental analysis of bubble growth, departure and interactions during pool boiling on artificial nucleation sites

The present work describes experimental results of pentane pool boiling, simplified to the cases of boiling on a single or on two adjacent nucleation sites. Bubbles growths have been recorded by a high speed camera under various wall superheat conditions. Bubble volume has been plotted as a function of time, and an experimental growth law has been proposed. Oscillations were observed during growth, showing the interaction of one bubble with the preceding bubble released from the same nucleation site. Lateral coalescence has been visualized and the images have brought to the fore the capillary effects on the distortion of the interface. (author)

42 ENGINEERING↗

Circumferential temperature distribution during nucleate pool boiling outside smooth and modified horizontal tubes

In the work an approach to avoid a circumferential temperature distribution existing during nucleate pool boiling on a horizontal cylinder within low heat flux densities is presented. The idea of the approach is local heat transfer enhancement by a porous layer application on a part of the heating surface. An experiment on nucleate pool boiling heat transfer from horizontal cylinders to saturated R141b and water under atmospheric pressure is reported. Experiments have been conducted using stainless steel tubes with the outside diameter between 8 mm and 23 mm with the active length of 250 mm. The outside surface of the tubes was smooth or partially coated with a porous metallic layer. In particular, measurements of inside circumferential temperature distribution have been performed. (author)

42 ENGINEERING↗

Saturated nucleate boiling to binary and ternary mixtures on horizontal cylinder

In this investigation, a large number of experiments have been performed to determine saturated nucleate pool boiling heat transfer coefficients of MEA/water and DEA/water binary mixtures and that of water/MEA/DEA ternary mixtures. These heat transfer coefficients have been measured at atmospheric pressure and over a wide range of heat fluxes and solution concentrations. The heat flux has been varied in 14 different levels from 7 to about 230 kW/m{sup 2} and amines concentration has been changed in 10 different levels from zero to 84 wt%. Results show that strong reduction of heat transfer coefficient occurs as a result of mass transfer interference in this phenomenon. Furthermore, in this study, all the correlations proposed during the last years for the prediction of nucleate boiling heat transfer coefficient of mixtures have been categorized in three groups. Some experimental results have been compared with the most accurate representatives of these three groups and the corresponding RMS errors have been calculated. Also, impacts of important existing parameters in these correlations like ideal heat transfer coefficient (h{sub id.}) on the prediction have been discussed. (author)

42 ENGINEERING↗

An experimental study on sub-cooled flow boiling CHF of R134a at low pressure condition with atmospheric pressure (AP) plasma assisted surface modification

In this study, sub-cooled flow boiling critical heat flux tests at low pressure were conducted in a rectangular flow channel with one uniformly heated surface, using simulant fluid R-134a as coolant. The experiments were conducted under the following conditions: (1) inlet pressure (P) of 400-800 kPa, (2) mass flux (G) of 124-248 kg/m 2 s, (3) inlet sub-cooling enthalpy (ΔH i ) of 12~ 26 kJ/kg. Parametric trends of macroscopic system parameters (G, P, H i ) were examined by changing inlet conditions. Those trends were found to be generally consistent with previous understandings of CHF behavior at low pressure condition (i.e. reduced pressure less than 0.2). A fluid-to-fluid scaling model was utilized to convert the test data obtained with the simulant fluid (R-134a) into the prototypical fluid (water). The comparison between the converted CHF of equivalent water and CHF look-up table with same operation conditions were conducted, which showed good agreement. Furthermore, the effect of surface wettability on CHF was also investigated by applying atmospheric pressure plasma (AP-Plasma) treatment to modify the surface characteristic. With AP-Plasma treatment, the change of microscopic surface characteristic was measured in terms of static contact angle. The static contact angle was reduced from 80° on original non-treated surface to 15° on treated surface. An enhancement of 18% on CHF values under flow boiling conditions were observed on AP-Plasma treated surfaces compared to those on non-treated heating surfaces.

42 ENGINEERING↗

Thermal interaction effect on nucleation site distribution in subcooled boiling

An experimental work on subcooled boiling of refrigerant, R134a, to examine nucleation site distributions on both copper and stainless steel heating surfaces was performed. In order to obtain high fidelity active nucleation site density and distribution data, a high-speed digital camera was utilized to record bubble emission images from a view normal to heating surfaces. Statistical analyses on nucleation site data were done and their statistical distributions were obtained. Those experimentally observed nucleation site distributions were compared to the random spatial Poisson distribution. The comparisons showed that, rather than purely random, active nucleation site distributions on boiling surfaces are relatively more uniform. Experimental results also showed that on the copper heating surface, nucleation site distributions are slightly more uniform than on the stainless steel surface. This was concluded as the results of thermal interactions between nucleation sites with different solid thermal conductivities. A two dimensional thermal interaction model was then developed to quantitatively examine the thermal interactions between nucleation sites. The results give a reasonable explanation to the experimental observation on nucleation site distributions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wall Area of Influence and Growing Wall Heat Transfer due to Sliding Bubbles in Subcooled Boiling Flow

A variety of dynamical features of sliding bubbles and their impact on wall heat transfer were observed at subcooled flow boiling conditions in a vertical square test channel. Among the wide range of parameters observed, we particularly focus in this paper on (i) the sliding bubbles’ effect on wall heat transfer (supplemantry discussion to the authors’ previous work in Yoo et al. (2016a,b)) and (ii) the wall area influenced by sliding bubbles in subcooled boiling flow. At first, this study reveals that the degree of wall heat transfer improvement due to sliding bubbles depended less on the wall superheat condition as the mass flux increased. Also, the sliding bubble trajectory was found to be one of the critical factors in order to properly describe the wall heat transfer associated with sliding bubbles. In particular, the wall area influenced by sliding bubbles depended strongly on both sliding bubble trajectory and sliding bubble size; the sliding bubble trajectory was also observed to be closely related to the sliding bubble size. Importantly, these results indicate the limitation of current approach in CFD analyses especially for the wall area of bubble influence. In addition, the analyses on the temporal fraction of bubbles’ residence (FR) along the heated wall show that the sliding bubbles typically travel through narrow path with high frequency while the opposite was observed downstream. That is, both FR and sliding bubble trajectory depended substantially on the distance from nucleation site, which is expected to be similar for the quenching heat transfer mode induced by sliding bubbles.

42 ENGINEERING↗

Preliminary Feasibility, Design, and Hazard Analysis of a Boiling Water Test Loop Within the Idaho National Laboratory Advanced Test Reactor National Scientific User Facility

The Advanced Test Reactor (ATR) is a pressurized light-water reactor with a design thermal power of 250 MW. The principal function of the ATR is to provide a high neutron flux for testing reactor fuels and other materials. The ATR and its support facilities are located at the Idaho National Laboratory (INL). A Boiling Water Test Loop (BWTL) is being designed for one of the irradiation test positions within the. The objective of the new loop will be to simulate boiling water reactor (BWR) conditions to support clad corrosion and related reactor material testing. Further it will accommodate power ramping tests of candidate high burn-up fuels and fuel pins/rods for the commercial BWR utilities. The BWTL will be much like the pressurized water loops already in service in 5 of the 9 “flux traps” (region of enhanced neutron flux) in the ATR. The loop coolant will be isolated from the primary coolant system so that the loop’s temperature, pressure, flow rate, and water chemistry can be independently controlled. This paper presents the proposed general design of the in-core and auxiliary BWTL systems; the preliminary results of the neutronics and thermal hydraulics analyses; and the preliminary hazard analysis for safe normal and transient BWTL and ATR operation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a mechanistic model for sliding bubbles growth prediction in subcooled boiling flow

In this paper, a new mechanistic model for predicting the growth of sliding bubbles in subcooled boiling flow has been developed. The basis of this model is the assumption that the fundamental heat transfer mechanisms acting on a stagnant bubble growing at a nucleation site can also be applied to the growth of sliding bubbles. The physical assumptions of the existing bubble growth models were modified to reflect the intrinsic physics associated with the sliding bubble growth. The heat transfer mechanisms considered are microlayer evaporation, evaporation of superheated liquid, and condensation. The present model has been successfully validated against a broad set of subcooled flow boiling data, generated by three separate research groups using different working fluids and different heater surfaces. The model successfully reproduced the sliding bubble growth dependencies on mass flux, wall superheat, and liquid subcooling level as observed in the experiments. Finally, on the other hand, in a few cases where the bubble growth inertia was substantially involved in the sliding bubble growth, the predictive ability was limited.

42 ENGINEERING↗

Augmentation of pool boiling heat transfer on tube bundles using metal foam

Pool boiling on a tube bundle is one of the most important heat transfer modes in several industrial applications, including steam generators, shell and tube heat exchangers for waste heat recovery, and desalination. Although several enhanced tubes (e.g., external micro-finned tubes) have been extensively studied and commercialized, the studies that pertain to the metal foam enhanced tube bundles are limited in the open literature. The objective of the present study is to perform an experimental study to analyze the pool boiling heat transfer characteristics of a metal foam tube bundle and compare its performance with that of a tube bundle with no enhancement. The performance of the metal foam tube bundles with different porosities (81%, 75%, and 62%) is compared against the conventional bare tube bundle. The results showed that the heat transfer coefficients of the metal foam tube bundles are 100–212% higher than those of the bare tube bundle. Among the different porosities, metal foam with 75% porosity showed a higher heat transfer coefficient. Furthermore, the wall temperature of the metal foam tubes is nearly 5–14⁰C lower than that of the bare tubes. In conclusion, when compared with a tube pitch of 25.4 mm, a tube pitch of 19.05 mm showed a maximum of 9% and 14% enhancement in bare and metal foam tube bundles, respectively.

42 ENGINEERING↗

Prediction of heat transfer coefficients for forced convective boiling of N 2 -hydrocarbon mixtures at cryogenic conditions using artificial neural networks

A key problem faced in the design of heat exchangers, especially for cryogenic applications, is the determination of convective heat transfer coefficients in two-phase flow such as condensation and boiling of non-azeotropic refrigerant mixtures. Here, this paper proposes and evaluates three models for estimating the convective coefficient during boiling. These models are developed using computational intelligence techniques. The performance of the proposed models is evaluated using the mean relative error (mre), and compared to two existing models: the modified Granryd’s correlation and the Silver-Bell-Ghaly method. The three proposed models are distinguished by their architecture. The first is based on directly measured parameters (DMP-ANN), the second is based on equivalent Reynolds and Prandtl numbers (eq-ANN), and the third on effective Reynolds and Prandtl numbers (eff-ANN). In conclusion, the results demonstrate that the proposed artificial neural network (ANN)-based approaches greatly outperform available methodologies. While Granryd's correlation predicts experimental data within a mean relative error mre = 44% and the S-B-G method produces mre = 42%, DMP-ANN has mre = 7.4% and eff-ANN has mre = 3.9%. Considering that eff-ANN has the lowest mean relative error (one tenth of previously available methodologies) and the broadest range of applicability, it is recommended for future calculations. Implementation is straightforward within a variety of platforms and the matrices with the ANN weights are given in the appendix for efficient programming.

42 ENGINEERING↗

Performance comparison of charcoal cookstoves for Haiti: Laboratory testing with Water Boiling and Controlled Cooking Tests

Charcoal cooking accounts for a large portion of Haiti's energy usage and leads to severe economic, health, and environmental hardships. Organizations are hoping that fuel-efficient cookstoves can help solve the problem. In this study, four charcoal cookstoves intended for dissemination in Haiti were rigorously assessed and compared using Water Boiling and Controlled Cooking Tests. Due to the poor thermal efficiency of the traditional stove, all improved stoves saved fuel on average over the traditional with the majority also reducing the total emissions released. However, the traditional stove could be difficult to replace because it had the fastest time-to-boil, an important consideration for end users. Here, through the testing, the number of trials conducted was found to be an important consideration for error analysis. Also, noticeable differences in stove performance were seen between the two protocols, supporting arguments by prior researchers of the necessity to use multiple test protocols for practically useful comparisons.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of dissolved air on subcooled and saturated flow boiling of water in a small diameter tube at low pressure

Experimental results on flow boiling of air saturated water flowing through a tube of inner diameter d{sub i} = 4.03 mm are presented. Both subcooled and saturated flow boiling are investigated, covering pressures from 177 to 519 kPa, mass fluxes from 478 to 839 kg m{sup -2} s{sup -1} and heat fluxes from 210 to 736 kW m{sup -2}. By comparing the measured results with existing prediction methods derived for degassed liquids the study concludes that the presence of dissolved air in the testing fluid can be regarded as a second order effect, and no special attention to dissolved air appears required. (author)

42 ENGINEERING↗

Heat transfer characteristics of R410A-oil mixture flow boiling inside a 7 mm straight smooth tube

Two-phase flow patterns and heat transfer characteristics of R410A-oil mixture flow boiling inside a straight smooth tube with the outside diameter of 7.0 mm were investigated experimentally. The experimental conditions include the evaporation temperature of 5 C, the mass flux from 200 to 400 kg m{sup -2} s{sup -1}, the heat flux from 7.56 to 15.12 kW m{sup -2}, the inlet vapor quality from 0.2 to 0.7, nominal oil concentration from 0% to 5%. The test results show that the heat transfer coefficient of R410A-oil mixture increases with mass flux of refrigerant-oil mixture; the presence of oil enhances the heat transfer at the range of low and intermediate vapor qualities; there is a peak of local heat transfer coefficient at about 2-4% nominal oil concentration at higher vapor qualities, and the peak shifts to lower nominal oil concentration with the increasing of vapor qualities; higher nominal oil concentration gives more detrimental effect at high vapor qualities. The flow pattern map of R410A-oil mixture was developed based on refrigerant-oil mixture properties, and the observed flow patterns match well with the flow pattern map. New correlation to predict the local heat transfer of R410A-oil mixture flow boiling inside the straight smooth tube was developed based on flow patterns and local properties of refrigerant-oil mixture, and it agrees with 90% of the experiment data within the deviation of {+-}25%. (author)

42 ENGINEERING↗

Numerical study on spray collapse process of ECN spray G injector under flash boiling conditions

This work features a numerical study of the spray collapse process that occurs under flash-boiling, gasoline-direct-injection conditions. The Engine Combustion Network's Spray G injector was modeled, and iso-octane, n-hexane, and propane were used as fuels with the goal to investigate fuel property effects. The development of individual jets and jet-to-jet interaction were analyzed to reveal the physical mechanisms of spray collapse. The results agreed qualitatively well with the experimental data of propane available from the literature and the predictions revealed the model's ability to capture the near-nozzle shock structures witnessed in the experiments. Simulations showed that the flow development of flashing sprays was strongly tied with the fuel properties. Specifically, under-expanded jets were not observed with iso-octane due to the fuel's low vapor pressure. In the case of n-hexane, the jets were under-expanded, and a low-pressure core was observed inside the jets due to the flow expansion. With propane, the very strong expansion caused the flow to become transonic and generate a unique shock structure near the nozzle exit. The shock structure revealed the formation of primary shock cells within the jets and secondary shock cells induced by jet-to-jet interaction. Based on the results, the spray collapse under flash boiling conditions was mainly attributed to two effects, i.e., the decrease in pressure at the spray center induced by the low-pressure cores inside and between the jets, and the isolation effect due to the jet-to-jet interaction which contributed to maintain the pressure differential between the spray center and the ambient.

42 ENGINEERING↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗