Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Motions of a liquid in a pulsating bulb with application to problems of blood flow

Potential flows may be utilized to represent motions produced in pulsating bulbs. While the initial bulb shape may be arbitrary, sequential shapes are related by affine transformations. Two components appear in the distribution of pressure, one dependent on the instantaneous velocity and the other on the acceleration. For flows with stationary streamlines the inertial impedance is that of a simple mass, and is proportional to the first moment of the actual mass of fluid contained within the bulb. Examples treated are: (1) Expanding and collapsing circular cylinders, and (2) elliptical cylinders in which the perimeter is held constant. The thickness of the pulsatile laminar boundary layer is found to be approximately on millimeter for conditions in the vicinity of the heart. Conditions for separation and turbulence differ from those in steady flow.

Jones, R. T.↗

Simulation of blood flow through an artificial heart

A numerical simulation of the incompressible viscous flow through a prosthetic tilting disk heart valve is presented in order to demonstrate the current capability to model unsteady flows with moving boundaries. Both steady state and unsteady flow calculations are done by solving the incompressible Navier-Stokes equations in 3-D generalized curvilinear coordinates. In order to handle the moving boundary problems, the chimera grid embedding scheme which decomposes a complex computational domain into several simple subdomains is used. An algebraic turbulence model for internal flows is incorporated to reach the physiological values of Reynolds number. Good agreement is obtained between the numerical results and experimental measurements. It is found that the tilting disk valve causes large regions of separated flow, and regions of high shear.

Kiris, Cetin↗

Systematic Sensitivity Analysis of Metabolic Controllers During Reductions in Skeletal Muscle Blood Flow

An acute reduction in oxygen delivery to skeletal muscle is generally associated with profound derangements in substrate metabolism. Given the complexity of the human bioenergetic system and its components, it is difficult to quantify the interaction of cellular metabolic processes to maintain ATP homeostasis during stress (e.g., hypoxia, ischemia, and exercise). Of special interest is the determination of mechanisms relating tissue oxygenation to observed metabolic responses at the tissue, organ, and whole body levels and the quantification of how changes in oxygen availability affect the pathways of ATP synthesis and their regulation. In this study, we apply a previously developed mathematical model of human bioenergetics to study effects of ischemia during periods of increased ATP turnover (e.g., exercise). By using systematic sensitivity analysis the oxidative phosphorylation rate was found to be the most important rate parameter affecting lactate production during ischemia under resting conditions. Here we examine whether mild exercise under ischemic conditions alters the relative importance of pathways and parameters previously obtained.

Radhakrishnan, Krishnan↗

Effect of 1% Inspired CO2 During Head-Down Tilt on Ocular Structures, Cerebral Blood Flow, and Visual Acuity in Healthy Human Subjects

The cephalad fluid shift induced by microgravity has been hypothesized to elevate intracranial pressure (ICP) and contribute to the development of the visual impairment/intracranial pressure (VIIP) syndrome experienced by many astronauts during and after long-duration space flight. In addition, elevated ambient partial pressure of carbon dioxide (PCO2) on the International Space Station (ISS) has also been hypothesized to contribute to the development of VIIP. We seek to determine if an acute, mild CO2 exposure, similar to that occurring on the ISS, combined with the cephalad fluid shift induced by head-down tilt will induce ophthalmic and ICP changes consistent with the VIIP syndrome.

Laurie, S. S.↗

Medical support and technology for long-duration space missions

The current philosophy and development directions being taken towards realization of medical systems for use on board space stations are discussed. Data was gained on the performance of physical examinations, venipuncture and blood flow, blood smear and staining, white blood cell differential count, throat culture swab and colony count, and microscopy techniques during a 28-day period of the Skylab mission. It is expected that the advent of Shuttle flights will rapidly increase the number of persons in space, create a demand for in-space rather than on-earth medical procedures, and necessitate treatments for disorders without the provision for an early return to earth. Attention is being given to pressurized environment and extravehicular conditions of treatment, the possibilities of the use of the OTV for moving injured or ill crewmembers to other space stations, and to isolation of persons with communicable diseases from station crews.

Furukawa, S.↗

Improved Calibration Of Acoustic Plethysmographic Sensors

Improved method of calibration of acoustic plethysmographic sensors involves acoustic-impedance test conditions like those encountered in use. Clamped aluminum tube holds source of sound (hydrophone) inside balloon. Test and reference sensors attached to outside of balloon. Sensors used to measure blood flow, blood pressure, heart rate, breathing sounds, and other vital signs from surfaces of human bodies. Attached to torsos or limbs by straps or adhesives.

Zuckerwar, Allan J.↗

Cardiovascular responses of men and women to lower body negative pressure

Changes in blood flow and blood redistribution were measured by impedance plethysmography in the pelvic and leg regions of six male and four female subjects during three 5-min exposures to -20, -40, and -60 mm Hg lower body negative pressure (LBNP). Female subjects demonstrated significantly higher mean heart rate and lower leg blood flow indices than the male subjects during the recumbent control periods. Men had slightly higher mean resting systolic and diastolic blood pressures and higher mean control pelvic blood indices. Women demonstrated significantly less blood pooling in the legs and slightly less in the pelvic region than the men. All of the 18 tests with male subjects at -60 mm Hg were completed without initial signs of syncope, while only two of the tests with women were completed successfully without the subject exhibiting presyncopal conditions. Results indicate that impedance plethysmography can be used to measure segmental cardiovascular responses during LBNP and that females may be less tolerant to -60 mm Hg LBNP than males.

Montgomery, L. D.↗

Raised cerebrovascular resistance in idiopathic orthostatic intolerance: evidence for sympathetic vasoconstriction

Patients with idiopathic orthostatic intolerance (IOI) exhibit symptoms suggestive of cerebral hypoperfusion and an excessive decrease in cerebral blood flow associated with standing despite sustained systemic blood pressure. In 9 patients (8 women and 1 man aged 22 to 48 years) with IOI, we tested the hypothesis that volume loading (2000 cc normal saline) and alpha-adrenoreceptor agonism improve systemic hemodynamics and cerebral perfusion and that the decrease in cerebral blood flow with head-up tilt (HUT) could be attenuated by alpha-adrenoreceptor blockade with phentolamine. At 5 minutes of HUT, volume loading (-20+/-3.2 bpm) and phenylephrine (-18+/-3.4 bpm) significantly reduced upright heart rate compared with placebo; the effect was diminished at the end of HUT. Phentolamine substantially increased upright heart rate at 5 minutes (20+/-3.7 bpm) and at the end of HUT (14+/-5 bpm). With placebo, mean cerebral blood flow velocity decreased by 33+/-6% at the end of HUT. This decrease in cerebral blood flow with HUT was attenuated by all 3 interventions. We conclude that in patients with IOI, HUT causes a substantial decrease in cerebrovascular blood flow velocity. The decrease in blood flow velocity with HUT can be attenuated with interventions that improve systemic hemodynamics and therefore decrease reflex sympathetic activation. Moreover, alpha-adrenoreceptor blockade also blunts the decrease in cerebral blood flow with HUT but at the price of deteriorated systemic hemodynamics. These observations may suggest that in patients with IOI, excessive sympathetic activity contributes to the paradoxical decrease in cerebral blood flow with upright posture.

Non-NASA Center↗

Potential Mechanism Leading to Impaired Thermoregulation Following Microgravity Exposure

Prolonged exposure to microgravity or its analogues impairs thermoregulation in humans evidenced by higher internal temperatures following the exposure during a thermal challenge. Although the mechanism leading to this response has not been clearly delineated, we identified that prolonged head-down tilt (HDT) markedly impairs thermoregulatory reflex control of skin blood flow, as demonstrated by an increased internal temperature threshold for cutaneous vasodilation, and by a reduced slope of the relationship between the elevation in skin blood flow relative to the elevation in internal temperature. Recently, Fortney et al. identified similar responses in two individuals following 115 days of microgravity exposure. One possible mechanism leading to altered cutaneous vasodilation during a thermal challenge following actual or simulated microgravity exposure may be associated with baroreflex-mediated attenuation in the elevation of skin blood flow. During a heat stress the elevation in skin blood flow is accomplished through a combination of increased cutaneous vascular conductance and cardiac output, both of which result in central venous pressure (CVP) decreasing 2-6 mmHg. Reductions in CVP of this magnitude in normothermia decrease muscle blood flow and skin blood flow presumably through unloading the cardiopulmonary baroreceptors. It is unclear whether the reduction in CVP, and accompanying cardiopulmonary baroreceptor unloading, during passive heating buffers the elevation in skin blood flow. That is, would the elevation in skin blood flow be greater if CVP did not decrease, or decreased to a lesser extent during the heat stress? Conversely, if CVP decreased to a greater extend during a thermal challenge following a perturbation such as prolonged HDT, would the elevation in skin blood flow be attenuated during that thermal challenge? Given that prolonged HDT decreases plasma volume and central venous pressure, such a finding would provide a plausible hypothesis to explain why skin blood flow does not increase to the same extent during a heat stress following simulated or actual microgravity exposure. Thus, the purpose of this project was to identify whether cardiopulmonary baroreceptor unloading coincident with heat stress buffers the elevation in skin blood flow.

Crandall, C. G.↗