Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Nonlinear beam deflection in photonic lattices with negative defects

We demonstrate both theoretically and experimentally that a nonlinear beam can be reflected by a negative defect in a photonic lattice if the incident angle is below a threshold value. Above this threshold angle, the beam simply passes through the defect. This phenomenon occurs in both one- and two-dimensional photonic lattices, and it provides a way to use the incident angle to control beam propagation in a lattice network. If the defect is absent or positive, no evident transition from reflection to transmission occurs. These nonlinear phenomena are also compared with linear nondiffracting-beam propagation in a photonic lattice with a defect, and both similarities and differences are observed. In addition, some important features in linear and nonlinear beam propagations are explained analytically by using a linear model with a delta-function defect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A high-speed, high-efficiency phase controller for coherent beam combining based on SPGD algorithm

A phase controller for coherent beam combining (CBC) of fibre lasers has been designed and manufactured based on a stochastic parallel gradient descent (SPGD) algorithm and a field programmable gate array (FPGA). The theoretical analysis shows that the iteration rate is higher than 1.9 MHz, and the average compensation bandwidth of CBC for 5 or 20 channels is 50 kHz or 12.5 kHz, respectively. The tests show that the phase controller ensures reliable phase locking of lasers: When the phases of five lasers are locked by the improved control strategy with a variable gain, the energy encircled in the target is increased by 23 times than that in the single output, the phase control accuracy is better than λ/20, and the combining efficiency is 92%. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-B-201-00: Motion Management in Current Stereotactic Body Radiation Therapy (SBRT) Practice

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-01: Overcoming the Challenges of Motion Management in Current Lung SBRT Practice

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-02: Motion Management for Proton Lung SBR

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-03: MRI-Guided Tracking and Gating

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

Active noise control - Piezoceramic actuators in fluid/structure interaction models

A model for a 2-D acoustic cavity with a flexible boundary (a beam) controlled via piezoceramic patches producing bending moments in the beam is considered. The associated control problem for this fluid/structure interaction system to reduce the acoustic pressure in the cavity involves unbounded control inputs. Approximation methods in the context of an LQR state space formulation are discussed, and numerical results are presented to demonstrate the effectiveness of this approach in computing feedback controls for noise reduction.

Banks, H. T.↗

Design Specification for Beam Containment System Ion Chamber Gas Systems

Ionization chambers are used at SLAC as protection devices near collimators, dumps and areas where beam loss must be limited through engineering controls. The two detector technologies considered in this note are Protection Ionization Chambers (PICs) and Long Ionization Chambers (LIONs). The ionization chambers are typically installed in redundant pairs and are set by introducing a controlled beam loss and using the measurements to determine a trip current setting. As such, the trip setting for any installation is specific to the system and is usually reestablished following any change in the system (change of gas, operating pressure, detector placement).

Accelerators↗

A Measurement of the Total Hadronic $\pi^-$ on Argon Cross Section in the Kinetic Energy Range from 0.2-1 Giga-Electron Volts in a Liquid Argon Time Projection Chamber

The liquid argon time projection chamber (LArTPC) technology offers fine-grained tracking along with excellent calorimetric and particle identification capabilities, making it a powerful tool for experimental neutrino physics. Thus, the LArTPC has become the technology of choice for studying neutrino oscillations over short ( 1000 km) baselines by experiments such as MicroBooNE, SBND, ICARUS, and DUNE. The LArIAT (Liquid Argon in a Test-beam) experiment exposes a LArTPC to a controlled beam of charged particles at the Fermilab Test Beam Facility to perform calibration studies and measurements of charged hadron-argon cross sections, with the goal of helping to reduce systematic uncertainties in LArTPC-based neutrino experiments. This work presents a measurement of the total hadronic π⁻-Ar cross section in the kinetic energy range from 0.2 GeV to 1 GeV, using data from the LArIAT experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holographic signal processing for control of a flexible beam

A robust control system is presented for damping vibrations in a cantilevered beam. The distributed deflections of the beam are sensed using real-time holography. A hybrid processor which uses optical and digital processors is proposed to implement a distributed control algorithm. The controller is designed using the linear-quadratic-Gaussian method to add damping to a finite number of vibrational modes.

Barsky, Michael F.↗

High power microwave beam steering based on gyromagnetic nonlinear transmission lines

We demonstrate electronically controlled beam steering by high power RF pulses produced by two gyromagnetic nonlinear transmission lines (NLTLs) connected to a one high voltage driver. Each NLTL is capable of producing several ns RF pulses with peak power from 50 to 700 MW (6% standard deviation) at frequencies from 0.5 to 1.7 GHz (1% standard deviation) with 100 Hz repetition rate. Using a helix antenna allows irradiating of RF pulses with almost circular polarization and 350 MW maximum peak power, which corresponds to 350 kV effective potential of radiation. At the installation of two identical channels, we demonstrate the possibility of beam steering within ±15° in the horizontal plane by coherent RF pulses with circular polarization at 1.0 GHz center frequency. Fourfold increase in the power flux density for in-phase irradiation of RF pulses is confirmed by comparison with one-channel operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control of laser-beam spatial distribution for correcting the shape and refraction of eye cornea

The results of calculation and development of a device aimed at forming a laser beam with an annular intensity distribution and spatial mode homogenisation, as well as approbation of this device for biological phantoms and eyes in ex vivo experiments with laser non-ablative correction of the cornea profile, are presented. The radiation intensities and thermal field distributions on the surfaces of a phantom and isolated rabbit’s eye are investigated. The absence of significant heating in the central region of eye is confirmed. It is shown that this device can be used for laser impact in order to change symmetrically eye’s refraction. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digital Controller For Laser-Beam-Steering Subsystem

Report presents additional information about proposed apparatus described in "Beam-Steering Subsystem for Laser Communication" (NPO-19069). Discusses design of digital beam-steering control subsystem and, in particular, that part of design pertaining to digital compensation for frequency response of steering mirror.

Ansari, Homayoon↗

Electron-Beam Shaping in the Transmission Electron Microscope: Control of Electron-Beam Propagation Along Atomic Columns

We present a detailed analysis of the propagation of high-energy electron beams that have different shapes in a crystal of [100]-oriented zincblende GaN. Our study primarily focuses on Bessel beams and makes use of reformulated Bloch wave and multislice simulations. As a result of the simplicity of the momentum spectrum of a Bessel beam and the symmetry of the crystal, its propagation in the material can be described in a free-space representation, providing a deeper understanding of channeling phenomena and of probe intensity oscillation in the propagation direction. We also consider aperture-limited and Gaussian beams. As a result, the latter probes are shown to be optimal for coupling to 1s Bloch states and achieving minimal spreading along atomic columns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experimental Verification of Identification Algorithms for Control of Flexible Structures

An on going simple laboratory experiment, referred to as the Beam Control Experiment (BCE) is described which has the essential features of a large flexible structure. The experiment is used to develop and evaluate identification and control algorithms which lock promising in the active control of high performance large space structures. Some results on the maximum likelihood identification of the parameters of the beam actuator sensor assembly from experimental data is presented.

Sridher, B.↗

SU-F-T-382: Volumetric Modulated Arc Therapy (VMAT) Beam Angle Optimization in Pulsed Partial Brain Irradiation (PPBI) for Newly Diagnosed Glioblastoma

Purpose: To optimize VMAT beam parameters in PPBI to minimize treatment time. We investigate the coverage and organs at risk (OR) avoidance capability of shorter arcs with shorter treatment times. Methods: We evaluated the treatment plans for eleven previously treated PPBI patients. Each patient received 46Gy (2Gy×23) to the initial target and an additional 14Gy (2Gy×7) as a sequential boost. Each daily 2-Gy fraction was delivered as ten 0.2-Gy pulses separated by 3-minute intervals using VMAT. Each pulse was delivered using the same arc and covered at least 95% of the PTV with at least 95% of the prescription dose. To optimize the VMAT beam angle, an initial 360° full-arc VMAT plan was implemented. Beam control points and their corresponding dose rates were exported. A curve of the product of control point and dose rate was plotted against treatment beam angle. The optimum angle range was determined from this relationship. We chose the minimum continuous angle range that covered 85% of the area under the curve. Planning parameters, including treatment time for each pulse (T-pulse), PTV coverage, maximum dose (Dmax), homogeneity index (HI=D5/D95), R50 (50%IDL/PTV), and Dmax to ORs, were compared. Results: Mean PTV volume was 364.1±181.5cc. Mean T-pulse of partial-arc beams was 34.3±10.6s, vs. 63.0±1.7s (p<0.001) for that of full-arc beams. No significant differences were found for PTV V95, Dmax and R50, 99.4%±1.2% vs. 99.7%±0.5% (p=0.066), 108.0%±1.2% vs. 107.5%±1.1% (p=0.107), 2.95±0.38 vs. 2.87±0.35 (p=0.165), for the plans with partial-arc and full-arc beams, respectively. However, plans using full-arc do provide better PTV V100 and HI, 96.0%±3.0% vs. 97.2%±2.0% (p=0.025) and 1.06±0.03 vs. 1.04±0.01 (p=0.009). No significant difference was found on Dmax to ORs. Conclusion: PPBI with optimized partial-arc plans are clinically comparable to full-arc plans, while treatment time be significantly reduced, average saving of 287s for a 10-pulse treatment.

60 APPLIED LIFE SCIENCES↗