Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Angular Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Properties of triaxial, strongly deformed bands in {sup 167}Ta and {sup 167}Lu and the top-on-top model

Based on the particle-rotor model with one particle coupled to a triaxially deformed rotor, the experimental excitation energy relative to a reference E*-aI(I+1) and the ratio between interband and intraband electromagnetic transitions are well reproduced for {sup 167}Ta with {gamma}=19 deg. The same parameter set for the angular-momentum-dependent rigid-body moments of inertia attains good agreement with experimental data for the positive-parity triaxial, strongly deformed (TSD) band levels in {sup 167}Lu. An attempt is made to investigate the negative-parity TSD band in {sup 167}Lu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Projection imaging of photon beams by the Cerenkov effect

Purpose: A novel technique for beam profiling of megavoltage photon beams was investigated for the first time by capturing images of the induced Cerenkov emission in water, as a potential surrogate for the imparted dose in irradiated media. Methods: A high-sensitivity, intensified CCD camera (ICCD) was configured to acquire 2D projection images of Cerenkov emission from a 4 Multiplication-Sign 4 cm{sup 2} 6 MV linear accelerator (LINAC) x-ray photon beam operating at a dose rate of 400 MU/min incident on a water tank with transparent walls. The ICCD acquisition was gated to the LINAC sync pulse to reduce background light artifacts, and the measurement quality was investigated by evaluating the signal to noise ratio and measurement repeatability as a function of delivered dose. Monte Carlo simulations were used to derive a calibration factor for differences between the optical images and deposited dose arising from the anisotropic angular dependence of Cerenkov emission. Finally, Cerenkov-based beam profiles were compared to a percent depth dose (PDD) and lateral dose profile at a depth of d{sub max} from a reference dose distribution generated from the clinical Varian ECLIPSE treatment planning system (TPS). Results: The signal to noise ratio was found to be 20 at a delivered dose of 66.6 cGy, and proportional to the square root of the delivered dose as expected from Poisson photon counting statistics. A 2.1% mean standard deviation and 5.6% maximum variation in successive measurements were observed, and the Monte Carlo derived calibration factor resulted in Cerenkov emission images which were directly correlated to deposited dose, with some spatial issues. The dose difference between the TPS and PDD predicted by Cerenkov measurements was within 20% in the buildup region with a distance to agreement (DTA) of 1.5-2 mm and {+-}3% at depths beyond d{sub max}. In the lateral profile, the dose difference at the beam penumbra was within {+-}13% with a DTA of 0-2 mm, {+-}5% in the central beam region, and 2%-3% in the beam umbra. Conclusions: The results from this initial study demonstrate the first documented use of Cerenkov emission imaging to profile x-ray photon LINAC beams in water. The proposed modality has several potential advantages over alternative methods, and upon future refinement may prove to be a robust and novel dosimetry method.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-463: Quantification of Rotational Variation in Mouse Setup for IGRT

Purpose: New small-animal irradiators include extremely precise IGRT capabilities. However, mouse immobilization and localization remains a challenge. In particular, unlike week-to-week translational displacements, rotational changes in positioning are not easily corrected for in subject setup. Using two methods of setup, we aim to quantify week-to-week rotational variation in mice for the purpose of IGRT planning in small animal studies. Methods: Ten mice were imaged weekly using breath-hold CBCT (X-RAD 225 Cx), with the mouse positioned in a half-pipe support, providing 40 scans. A second group of two mice were positioned in a 3D printed immobilization device, which was created using a CT from a similarly shaped mouse, providing 10 scans. For each mouse, the first image was taken to be the reference image. Subsequent CT images were then rigidly registered, based on bony anatomy. Rotations in the axial (roll), sagittal (pitch), and coronal (yaw) planes were recorded and used to quantify variation in angular setup. Results: For the mice imaged in the half pipe, average magnitude of roll was found to be 5.4±4.6° (range: −12.9:18.86°), of pitch 1.6±1.3° (range: −1.4:4.7°), and of yaw 1.9±1.5° (range −5.4:1.1°). For the mice imaged in the printed setup; average magnitude of roll was found to be 0.64±0.6° (range: −2.1:1.0°), of pitch 0.6±0.4° (range: 0.0:1.3°), and of yaw 0.2±0.1° (range: 0.0:0.4°). The printed setup provided reduction in roll, pitch, and yaw by 88, 62, and 90 percent, respectively. Conclusion: For the typical setup routine, roll in mouse position is the dominant source of rotational variation. However, when a printed device was used, drastic improvements in mouse immobilization were seen. This work provides a promising foundation for mouse immobilization, required for full scale small animal IGRT. Currently, we are making improvements to allo±w the use of a similar system for MR, PET, and bioluminescence.

60 APPLIED LIFE SCIENCES↗

Reference data, predictors, and probability grids for forest degradation classes in three sites in the Brazilian Amazon

Forest degradation by fires and selective logging is widespread in the Amazon region. We implemented a gradient boosted classification modeling framework to classify intact, logged, and burned forests at three Amazonian sites: Feliz Natal Municipality and Xingu Indigenous Territory in Mato Grosso State, and Saracá-Taquera National Forest in Pará State. We used forest degradation history from Landsat time-series as reference data and textural metrics derived from PlanetScope images as predictors. Textural metrics were computed using the Gray-Level Co-Occurrence Matrix (GLCM) textural technique. Included in the attached zip file are ten files: - a shapefile containing the reference data (fire and selective logging polygons and year of event) for each site; - a multiband tif file containing the 8 GLCM metrics used as predictors (Mean, Variance, Homogeneity, Contrast, Dissimilarity, Entropy, Angular Second Moment, Correlation) at the original PlanetScope resolution (3.125m) for each site; - a multiband tif file containing the 72 aggregated GLCM metrics used as predictors (Mean, Variance, Homogeneity, Contrast, Dissimilarity, Entropy, Angular Second Moment, and Correlation aggregated using the mean, first quartile, third quartile, maximum, median, minimum, root mean square, standard deviation, and skewness statistics) at 562m resolution for each site; - a multiband tif file containing the 3 probability grids for either intact, logged, or burned forests at the aggregation resolution (562m) for each site.

54 ENVIRONMENTAL SCIENCES↗

Characterization of DESI fiber assignment incompleteness effect on 2-point clustering and mitigation methods for DR1 analysis

We present an in-depth analysis of the fiber assignment incompleteness in the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 (DR1). This incompleteness is caused by the restricted mobility of the robotic fiber positioner in the DESI focal plane, which limits the number of galaxies that can be observed at the same time, especially at small angular separations. As a result, the observed clustering amplitude is suppressed in a scale-dependent manner, which, if not addressed, can severely impact the inference of cosmological parameters. We discuss the methods adopted for simulating fiber assignment on mocks and data. In particular, we introduce the fast fiber assignment (FFA) emulator, which was employed to obtain the power spectrum covariance adopted for the DR1 full-shape analysis. We present the mitigation techniques, organised in two classes: measurement stage and model stage. We then use high fidelity mocks as a reference to quantify both the accuracy of the FFA emulator and the effectiveness of the different measurement-stage mitigation techniques. This complements the studies conducted in a parallel paper for the model-stage techniques, namely the θ-cut approach. We find that pairwise inverse probability (PIP) weights with angular upweighting recover the “true” clustering in all the cases considered, in both Fourier and configuration space. Notably, we present the first ever power spectrum measurement with PIP weights from real data.

cosmological simulations↗

SU-E-T-459: Dosimetric Consequences of Rotated Elliptical Proton Spots in Modeling In-Air Proton Fluence for Calculating Doses in Water of Proton Pencil Beams

Purpose: We present a study of dosimetric consequences on doses in water in modeling in-air proton fluence independently along principle axes for rotated elliptical spots. Methods: Phase-space parameters for modeling in-air fluence are the position sigma for the spatial distribution, the angle sigma for the angular distribution, and the correlation between position and angle distributions. Proton spots of the McLaren proton therapy system were measured at five locations near the isocenter for the energies of 180 MeV and 250 MeV. An elongated elliptical spot rotated with respect to the principle axes was observed for the 180 MeV, while a circular-like spot was observed for the 250 MeV. In the first approach, the phase-space parameters were derived in the principle axes without rotation. In the second approach, the phase space parameters were derived in the reference frame with axes rotated to coincide with the major axes of the elliptical spot. Monte-Carlo simulations with derived phase-space parameters using both approaches to tally doses in water were performed and analyzed. Results: For the rotated elliptical 180 MeV spots, the position sigmas were 3.6 mm and 3.2 mm in principle axes, but were 4.3 mm and 2.0 mm when the reference frame was rotated. Measured spots fitted poorly the uncorrelated 2D Gaussian, but the quality of fit was significantly improved after the reference frame was rotated. As a Result, phase space parameters in the rotated frame were more appropriate for modeling in-air proton fluence of 180 MeV protons. Considerable differences were observed in Monte Carlo simulated dose distributions in water with phase-space parameters obtained with the two approaches. Conclusion: For rotated elliptical proton spots, phase-space parameters obtained in the rotated reference frame are better for modeling in-air proton fluence, and can be introduced into treatment planning systems.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-156: Can Sr-90 Check Sources Replace Co-60 Measurements for Monitoring of Reference Chamber Stability?

Purpose: To determine the ultimate precision of a system for monitoring reference-class ion chamber stability using a commercial Sr-90 check source. Methods: A detailed investigation of a commercial Sr-90 check source (PTW48002) was carried out using a series of Farmer-type ionization chambers. Investigations included: positioning repeatability (angular variation as chamber is rotated in source, variation in ionization current with vertical alignment); chamber settling; short and long term repeatability Results: i) Measurement precision – the ionization current was typically 10 pA, and therefore a high-precision electrometer is required to prevent electrometer noise/resolution/leakage biaising the results. ii) Chamber settling - the chamber response stabilizes after approximately 10 minutes, which is longer than reported for linac beams and is likely due to the low doserate of the source.iii) The measured response depended at the 1 % level on the orientation of the chamber with respect to the source. However, consistent positioning resulted in repeatability at the 0.05 % level. Care was also required to ensure that the chamber was consistently positioned vertically with respect to the source. The sensitivity to vertical position was found to be > 1 % per mm.iv)With a uniform procedure the long-term (> 6 month) repeatability was found to be better than 0.1 % for multiple chamber types and potentially a precision of 0.05 % is achievable. Conclusion: A Sr-90 check source is easy to use and is a viable alternative to Co-60 for monitoring reference chamber stability.

60 APPLIED LIFE SCIENCES↗

Peridynamic bond-associated correspondence model: Stability and convergence properties

The correspondence approach is a powerful technique that permits the usage of standard constitutive models from local theory within a peridynamic formulation. However, the conventional correspondence formulation suffers from material instability, i.e. zero-energy modes, that must be controlled for it to be applied in practice. The recently-introduced correspondence reformulation based on the use of a bond-associated deformation gradient can inherently remove the material instability. In this paper, we characterize some important properties, i.e. balance of linear momentum, balance of angular momentum and material stability, of the bond-associated correspondence model. The convergence behavior is also examined. Here, the accuracy of this approach is further demonstrated by comparing model predictions against local reference solutions and results from the conventional correspondence model with penalty stabilization for both two-dimensional and three-dimensional problems.

42 ENGINEERING↗

Jet momentum dependence of jet quenching in PbPb collisions at $\sqrt{s_{NN}}=2.76$ TeV

Dijet production in PbPb collisions at a nucleon-nucleon center-of-mass energy of 2.76 TeV is studied with the CMS detector at the LHC. A data sample corresponding to an integrated luminosity of 150 inverse microbarns is analyzed. Jets are reconstructed using combined information from tracking and calorimetry. The dijet momentum balance and angular correlations are studied as a function of collision centrality and leading jet transverse momentum. For the most peripheral PbPb collisions, good agreement of the dijet momentum balance distributions with pp data and reference calculations at the same collision energy is found, while more central collisions show a strong imbalance of leading and subleading jet transverse momenta attributed to the jet-quenching effect. The dijet momentum imbalance in central collisions is found to persist for leading jet transverse momenta up to the highest values studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beyond the crystallization paradigm: Structure determination from diffraction patterns from ensembles of randomly oriented particles

We amplify on the priciples of the method we have recently proposed for recovering an oversampled diffraction pattern of a single particle from measured diffraction patterns from multiple particles in orientations related by rotation about an axis parallel to the incident radiation. We propose an alternative method of phasing a reference resolution ring by means of a non-negativity constraint on the diffraction intensities, point out the need for caution about enantiomeric ambiguities in the reconstruction of a diffraction pattern from its angular correlations, and show that converged correlations may be deduced by appropriate averaging of even very noisy data.

59 BASIC BIOLOGICAL SCIENCES↗

TIME-AVERAGE-BASED METHODS FOR MULTI-ANGULAR SCALE ANALYSIS OF COSMIC-RAY DATA

Over the past decade, a number of experiments dealt with the problem of measuring the arrival direction distribution of cosmic rays, looking for information on the propagation mechanisms and the identification of their sources. Any deviation from the isotropy may be regarded to as a signature of unforeseen or unknown phenomena, mostly if well localized in the sky and occurring at low rigidity. It induced experimenters to search for excesses down to angular scales as narrow as 10 Degree-Sign , disclosing the issue of properly filtering contributions from wider structures. A solution commonly envisaged was based on time-average methods to determine the reference value of cosmic-ray flux. Such techniques are nearly insensitive to signals wider than the time window in use, thus allowing us to focus the analysis on medium- and small-scale signals. Nonetheless, the signal often cannot be excluded in the calculation of the reference value, which induces systematic errors. The use of time-average methods recently revealed important discoveries about the medium-scale cosmic-ray anisotropy, present both in the northern and southern hemispheres. It is known that the excess (or deficit) is observed as less intense than in reality and that fake deficit zones are rendered around true excesses because of the absolute lack of knowledge a priori of which signal is true and which is not. This work is an attempt to critically review the use of time-average-based methods for observing extended features in the cosmic-ray arrival distribution pattern.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

U.S. Department of Energy Reference Model Program RM1: Experimental Results.

The Reference Model Project (RMP), sponsored by the U.S. Department of Energy’s (DOE) Wind and Water Power Technologies Program within the Office of Energy Efficiency & Renewable Energy (EERE), aims at expediting industry growth and efficiency by providing nonproprietary Reference Models (RM) of MHK technology designs as study objects for opensource research and development (Neary et al. 2014a,b). As part of this program, MHK turbine models were tested in a large open channel facility at the University of Minnesota’s St. Anthony Falls Laboratory (UMN-SAFL). Reference Model 1 (RM1) is a 1:40 geometric scale dual-rotor axial flow horizontal axis device with counter-rotating rotors, each with a rotor diameter dT = 0.5m. Precise blade angular position and torque measurements were synchronized with three acoustic Doppler velocimeters (ADVs) aligned with each rotor and the midpoint for RM1. Flow conditions for each case were controlled such that depth, h = 1m, and volumetric flow rate, Qw = 2.425m3s-1, resulting in a hub height velocity of approximately Uhub = 1.05ms-1 and blade chord length Reynolds numbers of Rec ≈ 3.0x105. Vertical velocity profiles collected in the wake of each device from 1 to 10 rotor diameters are used to estimate the velocity recovery and turbulent characteristics in the wake, as well as the interaction of the counter-rotating rotor wakes. The development of this high resolution laboratory investigation provides a robust dataset that enables assessing turbulence performance models and their ability to accurately predict device performance metrics, including computational fluid dynamics (CFD) models that can be used to predict turbulent inflow environments, reproduce wake velocity deficit, recovery and higher order turbulent statistics, as well as device performance metrics.

17 WIND ENERGY↗

SU-E-T-234: Daily Quality Assurance for a Six Degrees of Freedom Couch Using a Novel Phantom

Purpose: To test the accuracy and reproducibility of both translational and rotational movements for a couch with six degrees of freedom (6DoF) using a novel phantom design Methods: An end-to-end test was carried out using two different phantoms. A 6 cm3 cube with a central fiducial BB (WL-QA Sun Nuclear) and a custom fabricated rectangular prism (31 cm x 8 cm x 8 cm), placed on a baseplate with known angular offsets for pitch, roll and yaw with a central fiducial BB and unique surface structures for registration purposes, were used. The end-to-end test included an initial CT simulation for a reference study, setup to an offset mark on each phantom, registration of the reference CT to the acquired cone-beam CT, and final Winston-Lutz delivery at four cardinal gantry angles. Results for both translational and rotational movements were recorded and compared for both phantoms. Results: Translational and rotational measurements were performed with a PerfectPitch (Varian) couch for 10 trials for both phantoms. Distinct translational shifts were [−5.372±0.384mm, −10.183±0.137mm, 14.028±0.155mm] for the cube and [7.520±0.159mm, −9.117±0.101mm, 16.273±0.115mm] for the prototype phantom for lateral, longitudinal, and vertical shifts, respectively. Distinct rotational adjustments were [1.121±0.102o, −1.067±0.235o, −2.662±0.380o] for the cube and [2.534±0.059o, 1.994±0.025o, 2.094±0.076o] for the prototype for pitch, roll, and yaw, respectively. Winston-Lutz test results performed after 6DoF couch correction from each cardinal gantry angle ranged from 0.26–0.72mm for the cube and 0.55–0.86mm for the prototype. Conclusion: The prototype phantom is more precise for both translational and rotational adjustments compared to a commercial phantom. The design of the prototype phantom allows for a more discernible visual confirmation of correct translational and rotational adjustments with the prototype phantom. Winston-Lutz results are more accurate for the commercial phantom but are still within tolerance for the prototype phantom.

60 APPLIED LIFE SCIENCES↗

Fabrication and Study of a Concave Crystal Mirror for the KORTES Project

A method for fabrication of a concave spherical mirror made of crystalline quartz is proposed and X-ray optical properties of the mirror are studied. The radius of curvature is 1630 mm. The shape of the mirror surface is studied using an interferometer with a diffraction reference wave. In the entire processing region, the maximum deviation from the nearest sphere is about 0.2 μm and the rms is 34 nm, so that high quality of imaging is provided with an angular error of about 2″ (angular seconds). Reflection coefficient (about 7%) and lower bound limit of spectral selectivity (λ/δλ ≈ 1775) are determined in the vicinity of a wavelength of λ = 0.834 nm, which is close to the working wavelengths of the MgXII doublet (λ = 0.8418 and 0.8423 nm). Position of the Bragg peak and spectral selectivity remain unchanged upon bending of the crystal mirror within measurement accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

U.S. Department of Energy Reference Model Program RM1: Experimental Results

The Reference Model Project (RMP), sponsored by the U.S. Department of Energy’s (DOE) Wind and Water Power Technologies Program within the Office of Energy Efficiency & Renewable Energy (EERE), aims at expediting industry growth and efficiency by providing non-proprietary Reference Models (RM) of MHK technology designs as study objects for open-source research and development (Neary et al. 2014a,b). As part of this program, MHK turbine models were tested in a large open channel facility at the University of Minnesota’s St. Anthony Falls Laboratory (UMN-SAFL). Reference Model 1 (RM2) is a 1:40 geometric scale dual-rotor axial flow horizontal axis device with counter-rotating rotors, each with a rotor diameter d T = 0.5m. Precise blade angular position and torque measurements were synchronized with three acoustic Doppler velocimeters (ADVs) aligned with each rotor and the midpoint for RM1. Flow conditions for each case were controlled such that depth, h = 1m, and volumetric flow rate, Q w = 2.425m3s -1 , resulting in a hub height velocity of approximately U hub = 1.05ms -1 and blade chord length Reynolds numbers of R ec ≈ 3.0x105. Vertical velocity profiles collected in the wake of each device from 1 to 10 rotor diameters are used to estimate the velocity recovery and turbulent characteristics in the wake, as well as the interaction of the counter-rotating rotor wakes. The development of this high resolution laboratory investigation provides a robust dataset that enables assessing turbulence performance models and their ability to accurately predict device performance metrics, including computational fluid dynamics (CFD) models that can be used to predict turbulent inflow environments, reproduce wake velocity deficit, recovery and higher order turbulent statistics, as well as device performance metrics.

16 TIDAL AND WAVE POWER↗

Exchange of Alpha Particle in the {sup 16}O+{sup 12}C Elastic Scattering

We have analyzed twenty elastic scattering angular distributions of the {sup 16}O+{sup 12}C system, measured at Sao Paulo Pelletron Laboratory and also data from the literature. The energies cover the region around and above Coulomb barrier, ranging from 8.54 up to 75.43 MeV in the center of mass reference frame. In the {sup 16}O+{sup 12}C scattering, two different processes can occur which result in same exit channel, the elastic scattering and the exchange of an alpha particle between projectile and target. We have used the Optical Model formalism for the elastic scattering and the DWBA to describe the alpha transfer reaction contribution. Thus, by analyzing the {sup 16}O+C elastic scattering at backward angles we have obtained the {sup 16}O{sub gs} alpha spectroscopic factor.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Lattice Boltzmann Method applied to neutron transport

In this paper the applicability of the Lattice Boltzmann Method to neutron transport is investigated. One of the main features of the Lattice Boltzmann method is the simultaneous discretization of the phase space of the problem, whereby particles are restricted to move on a lattice. An iterative solution of the operator form of the neutron transport equation is presented here, with the first collision source as the starting point of the iteration scheme. A full description of the discretization scheme is given, along with the quadrature set used for the angular discretization. An angular refinement scheme is introduced to increase the angular coverage of the problem phase space and to mitigate lattice ray effects. The method is applied to a model problem to investigate its applicability to neutron transport and the results are compared to a reference solution calculated, using MCNP. (authors)

97 MATHEMATICS AND COMPUTING↗

Interaction of 18-keV O{sup -} ions with Al{sub 2}O{sub 3} nanocapillaries

The transmission of 18-keV O{sup -} ions through Al{sub 2}O{sub 3} nanocapillaries with 50 nm in diameter and 12 {mu}m in length is studied in this work. By measuring angular distribution of transmitted particles when capillaries were tilted with respect to incident ion beam, two peaks were observed. It is distinguished that one of them is composed by direct transmitted ions and another one is composed by scattered ions. A phenomenon referred to as guiding effect, as found for highly charged ions and low-energy electrons, was observed. When negative ions (18-keV O{sup -}) are transmitted through nanocapillaries, most of them were ionized to neutral atoms and even positive ions. The intensity of transmitted particles (O{sup -}, O{sup 0}, and O{sup +}) decreased when the tilt angle increased. In transmitted particles, the fraction of O{sup -} declined but that of O{sup 0} and O{sup +} ions grew when the tilt angle grew. Both elastic collision and electrostatic scattering were found in scattered ions.

74 ATOMIC AND MOLECULAR PHYSICS↗