Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Angular Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Girth and groomed radius of jets recoiling against isolated photons in lead-lead and proton-proton collisions at $\sqrt{s_{NN}} = 5.02$ TeV

This Letter presents the first measurements of the groomed jet radius R g and the jet girth g in events with an isolated photon recoiling against a jet in lead-lead (PbPb) and proton-proton (pp) collisions at the LHC at a nucleon-nucleon center-of-mass energy of 5.02 TeV. The observables R g and g provide a quantitative measure of how narrow or broad a jet is. The analysis uses PbPb and pp data samples with integrated luminosities of 1.7 nb -1 and 301 pb -1 , respectively, collected with the CMS experiment in 2018 and 2017. Events are required to have a photon with transverse momentum $p^{γ}_{T} > 100$ GeV and at least one jet back-to-back in azimuth with respect to the photon and with transverse momentum $p^{jet}_{T}$ such that $p^{jet}_{T}/p^{γ}_{T} > 0.4$ . The measured R g and g distributions are unfolded to the particle level, which facilitates the comparison between the PbPb and pp results and with theoretical predictions. It is found that jets with $p^{jet}_{T}/p^{γ}_{T} > 0.8$ , i.e., those that closely balance the photon $p^{γ}_{T}$ , are narrower in PbPb than in pp collisions. Relaxing the selection to include jets with $p^{jet}_{T}/p^{γ}_{T} > 0.4$ reduces the narrowing of the angular structure of jets in PbPb relative to the pp reference. This shows that selection bias effects associated with jet energy loss play an important role in the interpretation of jet substructure measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute Source Activity Measurement with a Single Detector

In the present paper the activity of {sup 60}Co source was measured using the full absorption, sum and random coincidences (pile up) peaks and the total spectrum area in the gamma spectra. By the exact treatment of the chance coincidence and pile-up events, surprisingly good results were obtained. With the source on the detector end-cap (when the angular correlation effects are negligible), this simple method yields absolute activity values deviating from the reference activity for about 1 percent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Long-lived qubit from three spin-(1/2) atoms

A system of three spin-(1/2) atoms allows the construction of a reference-frame-free (RFF) qubit in the subspace with total angular momentum j=1/2. The RFF qubit stays coherent perfectly as long as the spins of the three atoms are affected homogeneously. The inhomogeneous evolution of the atoms causes decoherence, but this decoherence can be suppressed efficiently by applying a bias magnetic field of modest strength perpendicular to the plane of the atoms. The resulting lifetime of the RFF qubit can be many days, making RFF qubits of this kind promising candidates for quantum information storage units. Specifically, we examine the situation of three {sup 6}Li atoms trapped in a CO{sub 2}-laser-generated optical lattice and find that, with conservatively estimated parameters, a stored qubit maintains a fidelity of 0.9999 for two hours.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-term motion in a restricted problem of rotational motion

A method of general perturbations, based on the use of Lie series to generate approximate canonical transformations, is applied to study the long-term effects of gravity-gradient torque and orbital evolution on the rotational motion of a triaxial, rigid satellite. The center of mass of the satellite is constrained to move in an elliptic orbit about an attracting point mass. The orbit, which has a constant inclination, is constrained to precess and spin with constant rates. The method of general perturbations is used to obtain the Hamiltonian for the nonresonant secular and long-period rotational motion of the satellite to second order in n/omega sub 0, where n is the orbital mean motion of the center of mass and omega sub 0 is a reference value of the magnitude of the satellite's rotational angular velocity. The differential equations derivable from the transformed Hamiltonian are integrable, and the solution for the long-term motion may be expressed in terms of Jacobian elliptic functions and elliptic integrals. Geometrical aspects of the long-term rotational motion are discussed, and a comparison of theoretical results with observations is made.

Cochran, J. E.↗

ALSEP: Quasar differential VLBI

A program of Apollo Lunar Surface Experiments Package (ALSEP)-Quasar Very Long Baseline Interferometry (VLBI) is being reported. These observations primarily employ a 4 antenna technique, whereby simultaneous observations with two antennas at each end of an intercontinental baseline are used to derive the differential interferometric phase between a compact extragalactic radio source (usually a quasar) and a number of ALSEP transmitters on the lunar surface. A continous ALSEP-quasar differential phase history over a few hour period leads to extremely high angular accuracy in measuring the lunar position against the quasar reference frame. This application of the 4 antenna technique has been underway for more than a year and is now producing high quality data utilizing Deep Space Network (DSN) stations in Australia, Spain, and Goldstone, California, as well as the Spaceflight Tracking and Data Network (STDN) Apollo station at Goldstone.

Slade, M. A.↗

ALSEP-quasar differential VLBI

A program of ALSEP-quasar very-long-baseline interferometry (VLBI) is being carried out. These observations employ primarily a 'four-antenna' technique whereby simultaneous observations with two antennas at each end of an intercontinental baseline are used to derive the differential interferometric phase between a compact extragalactic radio source (usually a quasar) and a number of ALSEP transmitters on the lunar surface. A continuous ALSEP-quasar differential phase history over a period of a few hours will lead to milliarcsecond angular accuracy in measuring the lunar position against the quasar reference frame if suitable calibration measurements are obtained. Development of this application of the four-antenna technique has been underway for more than a year and is producing high-quality data utilizing Deep Space Network stations. These high-accuracy observations are of value to tie the lunar ephemeris to a nearly inertial extragalactic reference frame, to test gravitational theories, and to measure the earth-moon tidal friction interaction.

Slade, M. A.↗

An Analysis of the High Frequency Vibrations in Early Thematic Mapper Scenes

The potential effects of high frequency vibrations on the final Thematic Mapper (TM) image are evaluated for 26 scenes. The angular displacements of the TM detectors from their nominal pointing directions as measured by the TM Angular Displacement Sensor (ADS) and the spacecraft Dry Rotor Inertial Reference Unit (DRIRU) give data on the along scan and cross scan high frequency vibrations present in each scan of a scene. These measurements are to find the maximum overlap and underlap between successive scans, and to analyze the spectrum of the high frequency vibrations acting on the detectors. The Fourier spectrum of the along scan and cross scan vibrations for each scene also evaluated. The spectra of the scenes examined indicate that the high frequency vibrations arise primarily from the motion of the TM and MSS mirrors, and that their amplitudes are well within expected ranges.

Kogut, J.↗

A statistical study of the differential very long baseline interferometry delay rate error budget

The delta differential one-way Doppler (delta-DOD) error budget is assessed by analyzing 12 years of dual-frequency Deep Space Network very long baseline interferometry data. A typical delta-DOD observation is outlined, and the Magellan error budget along with tropospheric effects are considered. Formation of quasar-quasar observables, RMS delta-DOD residual, angular source separation and time separation between observations are discussed, along with elevation angle and atmospheric pathlength dependence, solar-plasma and ionospheric effects. It is concluded that the weak dependence of the delta-DOD error on angular source separation can mean that quasars with larger angular separation from a spacecraft may be used as navigation reference with little increase in the delta-DOD error. It is also indicated that the delta-DOD errors are dominated by wet troposphere fluctuations, and the results of numerical integrations for the single-station RMS delay rate at different elevation angles are presented.

Edwards, Charles D.↗

Stronger Source As Reference For Weaker Source In VLBI

Observation of weak astronomical radio source by very-long-baseline interferometry (VLBI) enhanced by using relatively strong astronomical radio source within small angular distance from weak source. Strong source and weak source observed alternately during measurement session. Direct detection of strong source provides reference delays and rates of change of delays used to integrate radio visibilities of weak source. Integrated visibilities added coherently over entire measurement session, using observed phases of strong source as references.

Lestrade, Jean-Francois↗

A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360 Degree-Sign through anthropomorphic voxelized female chest and head (0 Degree-Sign and 30 Degree-Sign tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tables of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI{sub vol} and multiplying by a physical CTDI{sub vol} measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30 Degree-Sign relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results indicate total organ doses calculated using our database are within 1% of those calculated using Monte Carlo simulations with the same geometry and scan parameters for all organs except red bone marrow (within 6%), and within 23% of published estimates for different voxelized phantoms. Results from the example of using the database to estimate organ dose for coronary angiography CT acquisitions show 2.1%, 1.1%, and -32% change in breast dose and 2.1%, -0.74%, and 4.7% change in lung dose for reduced kVp, tube current modulated, and partial angle protocols, respectively, relative to the reference protocol. Results show -19.2% difference in dose to eye lens for a tilted scan relative to a nontilted scan. The reported relative changes in organ doses are presented without quantification of image quality and are for the sole purpose of demonstrating the use of the proposed database. Conclusions: The proposed database and calculation method enable the estimation of organ dose for coronary angiography and brain perfusion CT scans utilizing any spectral shape and angular tube current modulation scheme by taking advantage of the precalculated Monte Carlo simulation results. The database can be used in conjunction with image quality studies to develop optimized acquisition techniques and may be particularly beneficial for optimizing dual kVp acquisitions for which numerous kV, mA, and filtration combinations may be investigated.

60 APPLIED LIFE SCIENCES↗

Inertially referenced instrument pointing platform with momentum compensated articulation

The characteristics of the Mariner Mark II Integrated Platform Pointing and Attitude Control System (IPPACS) microstep actuator with momentum compensation and the IPPACS optical reference tracker are examined, and the advantages of this new technology are identified. The momentum-compensated articulation acts to prevent platform articulation activity from disturbing the spacecaft. This guarantees dynamic stability, ensures a quiescent pointing environment, and decouples the design of the platform from the design of the spacecraft. A microstep actuator with harmonic drive provides platform angular step resolution to 0.5 arcsec for precision pointing of instruments. An optical reference tracker boresighted with scientific instruments guarantees accurate target-referenced closed-loop pointing. An IPPACS star and target tracker with 1 to 10 arcsec accuracy and wide 11 x 17 degrees field of view has been derived from Advanced Star and Target Reference Optical Sensor (ASTROS) CCD star tracker technology, greatly enhancing the optical referencing capabilities of future multimission interplanetary spacecraft.

Bell, C. E.↗

White organic light-emitting diodes with 4 nm metal electrode

We investigate metal layers with a thickness of only a few nanometers as anode replacement for indium tin oxide (ITO) in white organic light-emitting diodes (OLEDs). The ultrathin metal electrodes prove to be an excellent alternative that can, with regard to the angular dependence and efficiency of the OLED devices, outperform the ITO reference. Furthermore, unlike ITO, the thin composite metal electrodes are readily compatible with demanding architectures (e.g., top-emission or transparent OLEDs, device unit stacking, etc.) and flexible substrates. Here, we compare the sheet resistance of both types of electrodes on polyethylene terephthalate for different bending radii. The electrical performance of ITO breaks down at a radius of 10 mm, while the metal electrode remains intact even at radii smaller than 1 mm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new generation of x-ray spectrometry UHV instruments at the SR facilities BESSY II, ELETTRA and SOLEIL

A novel type of ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation (SR) has been constructed and commissioned at BESSY II. This versa-tile instrument was developed by the PTB, Germany’s national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, it integrates a rotational and translational movement of several photodiodes as well as a translational movement of a beam-geometry-defining aperture system. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors such as reference-free X-Ray Fluorescence (XRF) analysis, total-reflection XRF, grazing-incidence XRF, in addition to optional X-Ray Reflectometry (XRR) measurements or polarization-dependent X-ray absorption fine structure analyses (XAFS). Samples having a size of up to (100 × 100) mm{sup 2}; can be analyzed with respect to their mass deposition, elemental, spatial or species composition. Surface contamination, nanolayer composition and thickness, depth pro-file of matrix elements or implants, nanoparticles or buried interfaces as well as molecular orientation of bonds can be accessed. Three technology transfer projects of adapted instruments have enhanced X-Ray Spectrometry (XRS) research activities within Europe at the synchrotron radiation facilities ELETTRA (IAEA) and SOLEIL (CEA/LNE-LNHB) as well as at the X-ray innovation laboratory BLiX (TU Berlin) where different laboratory sources are used. Here, smaller chamber requirements led PTB in cooperation with TU Berlin to develop a modified instrument equipped with a 7-axis manipulator: reduced freedom in the choice of experimental geometry modifications (absence of out-of-SR-plane and reference-free XRS options) has been compensated by encoder-enhanced angular accuracy for GIXRF and XRR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A search for warm/hot gas filaments between pairs of SDSS Luminous Red Galaxies

Abstract We search the Planck data for a thermal Sunyaev–Zel’dovich (tSZ) signal due to gas filaments between pairs of Luminous Red Galaxies (LRGs) taken from the Sloan Digital Sky Survey Data Release 12 (SDSS/DR12). We identify ∼260 000 LRG pairs in the DR12 catalogue that lie within 6–10 $h^{-1} \, \mathrm{Mpc}$ of each other in tangential direction and within 6 $h^{-1} \, \mathrm{Mpc}$ in radial direction. We stack pairs by rotating and scaling the angular positions of each LRG so they lie on a common reference frame, then we subtract a circularly symmetric halo from each member of the pair to search for a residual signal between the pair members. We find a statistically significant (5.3σ) signal between LRG pairs in the stacked data with a magnitude Δy = (1.31 ± 0.25) × 10−8. The uncertainty is estimated from two Monte Carlo null tests which also establish the reliability of our analysis. Assuming a simple, isothermal, cylindrical filament model of electron overdensity with a radial density profile proportional to rc/r (as determined from simulations), where r is the perpendicular distance from the cylinder axis and rc is the core radius of the density profile, we constrain the product of overdensity and filament temperature to be $\delta _\mathrm{ c} \times (T_{\rm e}/10^7 \, {\rm K}) \times (r_\mathrm{ c}/0.5h^{-1} \, {\rm Mpc}) = 2.7 \pm 0.5$. To our knowledge, this is the first detection of filamentary gas at overdensities typical of cosmological large-scale structure. We compare our result to the BAHAMAS suite of cosmological hydrodynamic simulations (McCarthy et al. 2017) and find a slightly lower, but marginally consistent Comptonization excess, Δy = (0.84 ± 0.24) × 10−8.

Tanimura, Hideki↗

Spatial locality of electronic correlations in LiFeAs

In this work, we address the question of the degree of spatial nonlocality of the self-energy in the iron-based superconductors, a subject which is receiving considerable attention. Using LiFeAs as a prototypical example, we extract the self-energy from angular-resolved photoemission spectroscopy data. We use two distinct electronic structure references: density functional theory in the local density approximation and linearized quasiparticle self-consistent GW (LQSGW). We find that with the LQSGW reference, spatially local dynamical correlations provide a consistent description of the experimental data, and account for some surprising aspects of the data such as the substantial out-of-plane dispersion of the electron Fermi surface having dominant xz/yz character. Hence, correlations effects can be separated into static nonlocal contributions well described by LQSGW and dynamical local contributions. Hall effect and resistivity data are shown to be consistent with this description.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-494: Influence of Proton Track-Cell Nucleus Incidence Angle On Relative Biological Effectiveness

Purpose: To explain a Monte Carlo (MC) simulation artifact whereby differences in relative biological effectiveness (RBE) in the induction of initial double strand breaks are observed as a function of the proton track incidence angles in a geometric cell nucleus model. Secondly, to offer an alternative isotropic irradiation procedure to mitigate this effect. Methods: MC tracks of 1 MeV protons were generated in an event-by-event mode. They were overlaid on a cylindrical model of a cell nucleus containing 6×109 nucleotide base pairs. The tracks incidence angle θ with respect to the cell nucleus’s axis was varied in 10 degrees intervals, each time generating one hundred fractions of ∼2 Gy. Strand breaks were scored in the modeled DNA sugar-phosphate groups and further sub-classified into single or double strand breaks (ssbs or dsbs). For each angle, an RBE for the induction of initial dsbs with reference to Co-60 was calculated. Results: Our results show significant angular dependencies of RBE, with maximum values for incidence angles parallel to the nucleus central axis. Further examination shows that the higher cross-sections for the creation of dsbs is due to the preferential alignment of tracks with geometrical sub-parts of the cell nucleus model, especially the nucleosomes containing the sugar-phosphate groups. To alleviate the impact of this simulation artifact, an average RBE was calculated with a procedure based on a weighted sampling of the angular data. Conclusion: This work demonstrates a possible numerical artifact in estimated RBE if the influence of the particle incidence angle is not correctly taken into account. A correction procedure is presented to better conform the simulations to real-life experimental conditions. We would like to acknowledge support from the Fonds de recherche du Quebec Sante (FRQS), from the CREATE Medical Physics Research Training Network grant (number 432290) of NSERC, support from NSERC under grants RGPIN 397711-11 and RGPIN-2014-06475 and support from the CIHR under grants MOP-114910, MOP-136774 and MOP-102550.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRA-01: A Novel 3D Registration Method for Multiparametric Radiological Images

Purpose: Multiparametric and multimodality radiological imaging methods, such as, magnetic resonance imaging(MRI), computed tomography(CT), and positron emission tomography(PET), provide multiple types of tissue contrast and anatomical information for clinical diagnosis. However, these radiological modalities are acquired using very different technical parameters, e.g.,field of view(FOV), matrix size, and scan planes, which, can lead to challenges in registering the different data sets. Therefore, we developed a hybrid registration method based on 3D wavelet transformation and 3D interpolations that performs 3D resampling and rotation of the target radiological images without loss of information Methods: T1-weighted, T2-weighted, diffusion-weighted-imaging(DWI), dynamic-contrast-enhanced(DCE) MRI and PET/CT were used in the registration algorithm from breast and prostate data at 3T MRI and multimodality(PET/CT) cases. The hybrid registration scheme consists of several steps to reslice and match each modality using a combination of 3D wavelets, interpolations, and affine registration steps. First, orthogonal reslicing is performed to equalize FOV, matrix sizes and the number of slices using wavelet transformation. Second, angular resampling of the target data is performed to match the reference data. Finally, using optimized angles from resampling, 3D registration is performed using similarity transformation(scaling and translation) between the reference and resliced target volume is performed. After registration, the mean-square-error(MSE) and Dice Similarity(DS) between the reference and registered target volumes were calculated. Results: The 3D registration method registered synthetic and clinical data with significant improvement(p<0.05) of overlap between anatomical structures. After transforming and deforming the synthetic data, the MSE and Dice similarity were 0.12 and 0.99. The average improvement of the MSE in breast was 62%(0.27 to 0.10) and prostate was 63%(0.13 to 0.04;p<0.05). The Dice similarity was in breast 8%(0.91 to 0.99) and for prostate was 89%(0.01 to 0.90;p<0.05) Conclusion: Our 3D wavelet hybrid registration approach registered diverse breast and prostate data of different radiological images(MR/PET/CT) with a high accuracy.

60 APPLIED LIFE SCIENCES↗