Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analysis of Variance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A further analysis for the minimum-variance deconvolution filter performance

Chi and Mendel (1984) analyzed the performance of minimum-variance deconvolution (MVD). In this correspondence, a further analysis of the performance of the MVD filter is presented. It is shown that the MVD filter performs like an inverse filter and a whitening filter as SNR goes to infinity, and like a matched filter as SNR goes to zero. The estimation error of the MVD filter is colored noise, but it becomes white when SNR goes to zero. This analysis also conects the error power-spectral density of the MVD filter with the spectrum of the causal-prediction error filter.

Chi, Chong-Yung↗

Parameters’ Covariance in Neutron Time of Flight Analysis – Explicit Formulae

We present here a method that estimates the parameters’ variance in a parametric model for neutron time of flight (NToF). The analytical formulae for parameter variances, obtained independently of calculation of parameter values from measured data, express the variances in terms of the choice, settings, and placement of the detector and the oscilloscope. Consequently, the method can serve as a tool in planning a measurement setup.

fusion↗

Finite Element Model Calibration Approach for Area I-X

Ares I-X is a pathfinder vehicle concept under development by NASA to demonstrate a new class of launch vehicles. Although this vehicle is essentially a shell of what the Ares I vehicle will be, efforts are underway to model and calibrate the analytical models before its maiden flight. Work reported in this document will summarize the model calibration approach used including uncertainty quantification of vehicle responses and the use of non-conventional boundary conditions during component testing. Since finite element modeling is the primary modeling tool, the calibration process uses these models, often developed by different groups, to assess model deficiencies and to update parameters to reconcile test with predictions. Data for two major component tests and the flight vehicle are presented along with the calibration results. For calibration, sensitivity analysis is conducted using Analysis of Variance (ANOVA). To reduce the computational burden associated with ANOVA calculations, response surface models are used in lieu of computationally intensive finite element solutions. From the sensitivity studies, parameter importance is assessed as a function of frequency. In addition, the work presents an approach to evaluate the probability that a parameter set exists to reconcile test with analysis. Comparisons of pretest predictions of frequency response uncertainty bounds with measured data, results from the variance-based sensitivity analysis, and results from component test models with calibrated boundary stiffness models are all presented.

Horta, Lucas G.↗

Finite Element Model Calibration Approach for Ares I-X

Ares I-X is a pathfinder vehicle concept under development by NASA to demonstrate a new class of launch vehicles. Although this vehicle is essentially a shell of what the Ares I vehicle will be, efforts are underway to model and calibrate the analytical models before its maiden flight. Work reported in this document will summarize the model calibration approach used including uncertainty quantification of vehicle responses and the use of nonconventional boundary conditions during component testing. Since finite element modeling is the primary modeling tool, the calibration process uses these models, often developed by different groups, to assess model deficiencies and to update parameters to reconcile test with predictions. Data for two major component tests and the flight vehicle are presented along with the calibration results. For calibration, sensitivity analysis is conducted using Analysis of Variance (ANOVA). To reduce the computational burden associated with ANOVA calculations, response surface models are used in lieu of computationally intensive finite element solutions. From the sensitivity studies, parameter importance is assessed as a function of frequency. In addition, the work presents an approach to evaluate the probability that a parameter set exists to reconcile test with analysis. Comparisons of pre-test predictions of frequency response uncertainty bounds with measured data, results from the variance-based sensitivity analysis, and results from component test models with calibrated boundary stiffness models are all presented.

Horta, Lucas G.↗

Variance components in confocal scanning laser tomography measurements of neuro‐retinal rim area and the effect of repeated measurements on the power to detect loss over time

Abstract Purpose To estimate the variation in measurements of neuro‐retinal rim area (NRA) determined by confocal scanning laser tomography and consequences for clinical follow‐up. Methods Altogether, 24 healthy subjects were randomized on –320 μ m, Moorfields and Standard NRA plane strategies. Additionally, NRA was measured in 32 glaucoma subjects. Variance components for subjects, visits and measurements were estimated with analysis of variance. Sample sizes required to detect a 6.0 × 10 −2 mm 2 NRA change were estimated assuming a significance level of 0.05 and a power of 0.8. Consequences for independent group, and paired comparison design, respectively, were analysed. Further, precision in estimates within subjects over time was investigated. Results The variation of NRA among subjects was considerably larger than the variation among visits and measurements. For glaucoma subjects, the variation among visits and measurements were of the same order but larger than in healthy subjects. It was found that independent group comparisons require inconveniently large sample sizes. Within‐subject paired comparisons over time require sample sizes of below 15 subjects. The estimated variations for glaucoma subjects imply that 54 months of follow‐up is required for detection of change from baseline. Conclusions The variance for subjects is substantial in relation to those for visits and measurements. Cross‐sectional independent group comparisons of levels of NRA are unsuitable, due to considerable subject variation. Levels of NRA differences within subjects between visits can be estimated with acceptable precision. Neuro‐retinal rim area (NRA) measurement can be used for long‐term follow‐up of glaucoma progression.

Sandberg Melin, Camilla↗

Elliptically-Contoured Tensor-variate Distributions with Application to Image Learning

Statistical analysis of tensor-valued data has largely used the tensor-variate normal (TVN) distribution that may be inadequate for data arising from distributions with heavier or lighter tails. We study a general family of elliptically contoured (EC) TV distributions and derive its characterizations, moments, marginal, and conditional distributions. We describe procedures for maximum likelihood estimation from data that are (1) uncorrelated draws from an EC distribution, (2) from a scale mixture of the TVN distribution, and (3) from an underlying but unknown EC distribution, for which we extend Tyler’s robust estimator. A detailed simulation study highlights the benefits of choosing an EC distribution over the TVN for heavier-tailed data. We develop TV classification rules using discriminant analysis and EC errors and show that they better predict cats and dogs from images in the Animal Faces-HQ dataset than the TVN-based rules. A novel tensor-on-tensor regression and TV analysis of variance (TANOVA) framework under EC errors is also demonstrated to better characterize gender, age, and ethnic origin than the usual TVN-based TANOVA in the celebrated labeled faces of the wild dataset.

97 MATHEMATICS AND COMPUTING↗

Effects of 40Ar and 56Fe ions on retinal photoreceptor cells of the rabbit: implications for manned missions to Mars

Losses of photoreceptor cells (rods) from the retinas of New Zealand white (NZW) rabbits were detectable within 2 years after localized acute irradiation of optic and proximal tissues with > or = 7 Gy of 530 MeV u-1 40Ar ions or > or = 2 Gy of 465 MeV u-1 56Fe ions in the Bragg plateau region of energy deposition. Those limits were determined only from an analysis of variance of dose groups because the shapes of the dose response curves at early post-irradiation times are not known, a concern being addressed by experiments in progress. Losses of photoreceptor cells for the period 0.5-2.5 years post-irradiation, determined by provisional linear regression analysis, were approximately 1.7% Gy-1 and 2.5% Gy-1 for 40Ar and 56Fe ions, respectively.

NASA Discipline Radiation Health↗

Left ventricular outflow tract mean systolic acceleration as a surrogate for the slope of the left ventricular end-systolic pressure-volume relationship

OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.

Non-NASA Center↗

Unbalanced Nested Random Effects Estimation of Variance Components

To investigate the contributing factors of variance in the measurement of an iodine 127 (127I) sample, we implement a nested random effects analysis of variance (ANOVA). Historically, the reported uncertainty on a measurement of 127I has been obtained by methods of forward uncertainty propagation because there is typically only one replicate of a given sample for which to estimate the uncertainty. When samples are processed there are several types of quality control (QC) standards analyzed along-side the unknown samples with two to five replicates for each. Assuming the variance observed in these replicate QC standards is representative of that of the unknown samples, we use these data in a nested random effects ANOVA to estimate the total uncertainty of a measurement. We demonstrate this approach with two sets of measurements from Idaho National Laboratory and compare the results with the forward uncertainty propagation approach. Variance component estimates for the coarsest level of the nesting structure were most imprecise because replicates were most limited at these levels. We find that the results largely agree between forward propagation and ANOVA, and the greatest contributors of variance are due to instrument variation and chemical processing, with human processing being among the smallest contributors. This analysis provides reassurance that the reported uncertainties using forward propagation are reasonable and the process is well controlled. We propose a future designed experiment to increase replicates at the coarsest level of the hierarchy to improve estimates of these variance components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of secondary gas-phase reactions (SGR) in pyrolysis of carbon feedstocks for anisotropic carbon materials production – 2: Effects of SGR on tars produced from varying ranks of coal

Herein, this work explores the extent to which secondary gas-phase reactions (SGR) in pyrolysis can be used to modify coal tar chemistries from coals of different ranks in favor of improved anisotropy formation in their respective pitches. Pyrolysis was performed on four different coals of varying bituminous rank (Utah Sufco, Wyoming PRB Black Thunder, Illinois #6, and West Virginia Flying Eagle), with SGR temperatures ranging from 800 to 900° C and nominal SGR gas-phase residence times from 1 to 2.5 s. The oxygen content, aliphatic content, and molecular weight distributions of the coal tar samples were measured to indicate the changes with increasing levels of SGR, and microscopy was also used to measure changes in anisotropy formation in the resulting pitch samples. Generally, for all coals tested, increased levels of pyrolysis SGR led to decreased oxygen and aliphatic content, increased molecular weight sizes, and improved anisotropy formation. However, it was clear that the extent of these property changes depended on the chemistry and rank of the starting coal feedstock. Despite the relatively high rank of the Illinois #6 coal, its respective pitch samples performed poorly in improving anisotropy formation, due to its high sulfur content. The PRB, Sufco, and Flying Eagle coals performed better in their anisotropy formation than Illinois #6, depending on their respective coal ranks. Statistical analysis (analysis of variance, ANOVA) performed on the sample characterization data also suggests that SGR temperature is consistently the most dominant and significant effect on the resulting coal products.

01 COAL, LIGNITE, AND PEAT↗

Interannual variability and predictability of 500 mb geopotential heights over the Northern Hemisphere

The interannual variability of monthly mean 500 mb heights in a 15-year sample of observed data is compared to the variance expected from sampling errors associated with high-frequency fluctuations using the analysis of variance approach. The monthly mean 'signal' stands out significantly from the 'noise' over a substantial fraction of the Northern Hemisphere during the winter. The expected spectrum of variance at very low frequencies is assumed to be white at frequencies lower than per (30 days) rather than the per (96 days) cutoff used by Madden. This difference is justified by observing that the effective time between independent samples T(0) is relatively insensitive to changes in the maximum lag over which the local autocorrelation is integrated to calculate T(0). Further non-randomness in the variance of 500 mb heights is evidenced by the correlation between monthly mean height and contemporaneous daily variability.

Shukla, J.↗

Biological Sampling Variability Study

There are many sources of variability that exist in the sample collection and analysis process. This paper addresses many, but not all, sources of variability. The main focus of this paper was to better understand and estimate variability due to differences between samplers. Variability between days was also studied, as well as random variability within each sampler. Experiments were performed using multiple surface materials (ceramic and stainless steel), multiple contaminant concentrations (10 spores and 100 spores), and with and without the presence of interfering material. All testing was done with sponge sticks using 10-inch by 10-inch coupons. Bacillus atrophaeus was used as the BA surrogate. Spores were deposited using wet deposition. Grime was coated on the coupons which were planned to include the interfering material (Section 3.3). Samples were prepared and analyzed at PNNL using CDC protocol (Section 3.4) and then cultured and counted. Five samplers were trained so that samples were taken using the same protocol. Each sampler randomly sampled eight coupons each day, four coupons with 10 spores deposited and four coupons with 100 spores deposited. Each day consisted of one material being tested. The clean samples (no interfering materials) were run first, followed by the dirty samples (coated with interfering material). There was a significant difference in recovery efficiency between the coupons with 10 spores deposited (mean of 48.9%) and those with 100 spores deposited (mean of 59.8%). There was no general significant difference between the clean and dirty (containing interfering material) coupons or between the two surface materials; however, there was a significant interaction between concentration amount and presence of interfering material. The recovery efficiency was close to the same for coupons with 10 spores deposited, but for the coupons with 100 spores deposited, the recovery efficiency for the dirty samples was significantly larger (65.9% - dirty vs. 53.6% - clean) (see Figure 4.1). Variance component analysis was used to estimate the amount of variability for each source of variability. There wasn’t much difference in variability for dirty and clean samples, as well as between materials, so these results were pooled together. There was a significant difference in amount of concentration deposited, so results were separated for the 10 spore and 100 spore deposited tests. In each case the within sampler variability was the largest with variances of 426.2 for 10 spores and 173.1 for 100 spores. The within sampler variability constitutes the variability between the four samples of similar material, interfering material, and concentration taken by each sampler. The between sampler variance was estimated to be 0 for 10 spores and 1.2 for 100 spores. The between day variance was estimated to be 42.1 for 10 spores and 78.9 for 100 spores. Standard deviations can be calculated in each case by taking the square root of the variance.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of the helicopter environment on patient care capabilities: flight crew perceptions

INTRODUCTION: Flight crew perceptions of the effect of the rotary-wing environment on patient-care capabilities have not been subject to statistical analysis. We hypothesized that flight crew members perceived significant difficulties in performing patient-care tasks during air medical transport. METHODS: A survey was distributed to a convenience sample of flight crew members from 20 flight programs. Respondents were asked to compare the difficulty of performing patient-care tasks in rotary-wing and standard (emergency department or intensive care unit) settings. Demographic data collected on respondents included years of flight experience, flights per month, crew duty position and primary aircraft in which the respondent worked. Statistical analysis was performed as appropriate using Student's t-test, type III sum of squares, and analysis of variance. Alpha was defined as p < 0.05. RESULTS: Fifty-five percent of programs (90 individuals) responded. All tasks were significantly rated more difficult in the rotary-wing environment. Ratings were not significantly correlated with flight experience, duty position, flights per month or aircraft used. CONCLUSIONS: We conclude that the performance of patient-care tasks are perceived by air medical flight crew to be significantly more difficult during rotary-wing air medical transport than in hospital settings.

Noise, Transportation/adverse effects↗

Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions

OBJECTIVES: The purpose of this study was to evaluate the lossy Joint Photographic Experts Group compression for endodontic pretreatment digital radiographs. STUDY DESIGN: Fifty clinical charge-coupled device-based, digital radiographs depicting periapical areas were selected. Each image was compressed at 2, 4, 8, 16, 32, 48, and 64 compression ratios. One root per image was marked for examination. Images were randomized and viewed by four clinical observers under standardized viewing conditions. Each observer read the image set three times, with at least two weeks between each reading. Three pre-selected sites per image (mesial, distal, apical) were scored on a five-scale score confidence scale. A panel of three examiners scored the uncompressed images, with a consensus score for each site. The consensus score was used as the baseline for assessing the impact of lossy compression on the diagnostic values of images. The mean absolute error between consensus and observer scores was computed for each observer, site, and reading session. RESULTS: Balanced one-way analysis of variance for all observers indicated that for compression ratios 48 and 64, there was significant difference between mean absolute error of uncompressed and compressed images (P <.05). After converting the five-scale score to two-level diagnostic values, the diagnostic accuracy was strongly correlated (R (2) = 0.91) with the compression ratio. CONCLUSION: The results of this study suggest that high compression ratios can have a severe impact on the diagnostic quality of the digital radiographs for detection of periapical lesions.

NASA Discipline Space Human Factors↗

Predictive Modeling of NOx Emissions from Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blends Using Flame Imaging and Machine Learning

This research paper explores the use of machine learning to relate images of flame structure and luminosity to measured NOx emissions. Images of reactions produced by 16 aero-engine derived injectors for a ground-based turbine operated on a range of fuel compositions, air pressure drops, preheat temperatures and adiabatic flame temperatures were captured and postprocessed. The experimental investigations were conducted under atmospheric conditions, capturing CO, NO and NOx emissions data and OH* chemiluminescence images from 27 test conditions. The injector geometry and test conditions were based on a statistically designed test plan. These results were first analyzed using the traditional analysis approach of analysis of variance (ANOVA). The statistically based test plan yielded 432 data points, leading to a correlation for NOx emissions as a function of injector geometry, test conditions and imaging responses, with 70.2% accuracy. As an alternative approach to predicting emissions using imaging diagnostics as well as injector geometry and test conditions, a random forest machine learning algorithm was also applied to the data and was able to achieve an accuracy of 82.6%. This study offers insights into the factors influencing emissions in ground-based turbines while emphasizing the potential of machine learning algorithms in constructing predictive models for complex systems.

08 HYDROGEN↗

Angiogenesis and osteogenesis in an orthopedically expanded suture

The purpose of this study was to examine the angiogenic and the subsequent osteogenic responses during a 96-hour time-course after sutural expansion. Fifty rats were divided into: (1) a control group that received only angiogenic induction through injection of 5 ng/gm recombinant human endothelial cell growth factor (rhECGF); (2) an experimental group that received orthopedic expansion and rhECGF; (3) a sham group that received expansion and sodium chloride (NaCl) injection; and (4) a baseline group that received no expansion or injection. All rats were injected with 3H-thymidine (1.0 microCi/gm) 1 hour before death to label the DNA of S-phase cells. Demineralized sections (4 microm thick) were stained with hematoxylin and eosin. Angiogenesis and cell migration were analyzed with a previously established cell kinetics model. Analysis of variance was used to test the hypothesis that enhancement of angiogenesis stimulates reestablishment of osteogenic capability. Blood vessel number, area, and endothelial cell-labeled index significantly increased in experimental groups, but no difference was found between control and baseline groups. Labeled-pericyte index and activated pericyte numbers in the experimental group were also higher than in the sham groups. These results show that supplemental rhECGF enhances angiogenesis in expanded sutures but not in nonexpanded sutures. Data also suggest that pericytes are the source of osteoblasts in an orthopedically expanded suture.

NASA Discipline Musculoskeletal↗

Reactive control and reasoning assistance for scientific laboratory instruments

Scientific laboratory instruments that are involved in chemical or physical sample identification frequently require substantial human preparation, attention, and interactive control during their operation. Successful real-time analysis of incoming data that supports such interactive control requires: (1) a clear recognition of variance of the data from expected results; and (2) rapid diagnosis of possible alternative hypotheses which might explain the variance. Such analysis then aids in decisions about modifying the experiment protocol, as well as being a goal itself. This paper reports on a collaborative project at the NASA Ames Research Center between artificial intelligence researchers and planetary microbial ecologists. Our team is currently engaged in developing software that autonomously controls science laboratory instruments and that provides data analysis of the real-time data in support of dynamic refinement of the experiment control. the first two instruments to which this technology has been applied are a differential thermal analyzer (DTA) and a gas chromatograph (GC). coupled together, they form a new geochemicstry and microbial analysis tool that is capable of rapid identification of the organiz and mineralogical constituents in soils. The thermal decomposition of the minerals and organics, and the attendance release of evolved gases, provides data about the structural and molecular chemistry of the soil samples.

Thompson, David E.↗