Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Solar Powered Radioactive Air Monitoring Stations

Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

air sampling↗

High Throughput Argon-37 Field System

We report Pacific Northwest National Laboratory (PNNL) has developed a unique fieldable 37 Ar measurement system designed to measure 37 Ar activity concentrations from soil gas samples to detect above ground and underground nuclear explosions. The Argon-37 Field System is modular in design to accommodate both chemical processing and nuclear detection. The system can be packed into shipping crates and shipped to a location near where the sampling is taking place. The system can process six 2-m 3 whole-air samples in 24 hours and can measure the 37 Ar activity in each of the samples using six proportional counters. The proportional counters, designed and built at PNNL, are surrounded with both active and passive shielding to reduce background and can achieve a minimum detection concentration of 10 mBq/m 3 of 37 Ar in whole-air equivalent. The Argon-37 Field System has undergone extensive testing against rigorous requirements to assure the system meets the needs of the noble gas nuclear explosion monitoring community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Sulfuric Acid New Particle Formation Field Campaign Report

This campaign aimed to measure gaseous sulfuric acid concentrations at the surface level using a newly developed sulfuric acid dimethylamine-reactive condensation particle counter (SAD-RCPC). Sulfuric acid is a key nucleation precursor and is the likely driving compound for new particle formation at the Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory. The SAD-RCPC will be deployed in the future at ARM SGP (AFC010010: "Vertically Resolved Nucleation Precursors at SGP") scheduled for 2024. The campaign was in conjunction with Eleanor Browne's campaign (AFC010075: Boundary-layer gradients in new particle formation) and took place from 05/7/23 to 5/21/23. The measured sulfuric acid concentrations by the SAD-RCPC will be compared to concentrations measured by Browne's chemical ionization mass spectrometer (CIMS). The SAD-RCPC consisted of a glass flow reactor coupled to a 1-nm diethylene glycol condensation particle counter (DEG CPC). Sampled air was mixed with a high concentration of dimethylamine vapor (~1 ppbv). Sulfuric acid within the sampled gas nucleated with dimethylamine to form detectable 1-nm particles. The measured particle concentration was converted to sulfuric acid concentration using nucleation reaction kinetics. The pulse height distribution of particles detected by the DEG CPC was observed using a multi-channel analyzer. Large pre-existing particles were separated from the freshly formed particles in the SAD-RCPC from the pulse height distribution (PHD). During the short campaign, seven new particle formation events were observed. The SAD-RCPC detected an increase in sulfuric acid concentration, but this also coincided with an increase in pre-existing <3 nm particle concentrations. In addition, Browne's CIMS detect sulfuric acid concentrations in the range of 10 5 -10 6 cm -3 .

54 ENVIRONMENTAL SCIENCES↗

Measurement of Argon-37 Background Concentrations in the Atmosphere

Radioisotopes of noble gases, primarily xenon and argon, are important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133 Xe, 135 Xe, 131 mXe and 133 mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37 Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010). Therefore, inclusion of 37 Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations could improve the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37 Ar to evaluate the range of background concentrations. The range of 37 Ar concentrations measured in atmospheric air samples was relatively narrow ranging between less than 1 mBq/m 3 to greater than 2 mBq/m 3 . The average atmospheric concentration of all samples was 0.98 mBq/m 3 , with a standard deviation of 0.5 mBq/m 3 . This is consistent with previous published results. The results presented here demonstrate the capability to detect background concentrations of 37 Ar in atmospheric air.

61 RADIATION PROTECTION AND DOSIMETRY↗

Imprint of Anthropogenic Sources and Soil Removal on the Surface Concentration of H2 in the Contiguous US

Hydrogen (H2) is experiencing renewed interest throughout the world as a low carbon fuel alternative or complement to fossil fuels. Significant uncertainties remain regarding the environmental impact of increasing H2 usage, in part due to gaps in our understanding of the H2 atmospheric budget, including the H2 release from industrial activities and the H2 soil removal, the most important sink of H2. This study focuses on H2 dry air mole fractions measured by the NOAA Global Monitoring Laboratory in discrete ambient air samples collected every few days at sites located in the contiguous United States between 2010 and 2022. We take advantage of the long-term observations from this network to study the regional distribution of H2 sources using the potential source contribution function (PSCF). We find that H2 PSCF is consistent with a large anthropogenic source of atmospheric H2 from the incomplete combustion of fossil fuel. However, episodic air masses with high H2 dry air mole fractions (>700 ppb) recorded at some sampling locations in the Western and Southeastern US are not associated with elevated CO, suggesting significant noncombustion anthropogenic or geological sources of H2. Air masses depleted in H2 are recorded in rural or remote continental sites. Our analysis of observations from a tall tower in NE Colorado suggests that the degree of H2 depletion not only reflects differences in soil exposure but also the regional inhibition of the soil sink under arid conditions.

Paulot, Fabien↗

Short-lived species detection of nitrous acid by external-cavity quantum cascade laser based quartz-enhanced photoacoustic absorption spectroscopy

Spectroscopic detection of short-lived gaseous nitrous acid (HONO) at 1254.85 cm{sup −1} was realized by off-beam coupled quartz-enhanced photoacoustic spectroscopy (QEPAS) in conjunction with an external cavity quantum cascade lasers (EC-QCL). High sensitivity monitoring of HONO was performed within a very small gas-sample volume (of ∼40 mm{sup 3}) allowing a significant reduction (of about 4 orders of magnitude) of air sampling residence time which is highly desired for accurate quantification of chemically reactive short-lived species. Calibration of the developed QEPAS-based HONO sensor was carried out by means of lab-generated HONO samples whose concentrations were determined by direct absorption spectroscopy involving a ∼109.5 m multipass cell and a distributed feedback QCL. A minimum detection limit (MDL) of 66 ppbv (1 σ) HONO was achieved at 70 mbar using a laser output power of 50 mW and 1 s integration time, which corresponded to a normalized noise equivalent absorption coefficient of 3.6 × 10{sup −8 }cm{sup −1} W/Hz{sup 1/2}. This MDL was down to 7 ppbv at the optimal integration time of 150 s. The corresponding 1σ minimum detected absorption coefficient is ∼1.1 × 10{sup −7 }cm{sup −1} (MDL ∼ 3 ppbv) in 1 s and ∼1.1 × 10{sup −8 }cm{sup −1} (MDL ∼ 330 pptv) in 150 s, respectively, with 1 W laser power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CCG-Flasks Instrument Handbook

Surface-based sampling Samples are collected from the one of the two 60m inlet in the PGS shed. A site technician triggers sampling, usually at 2pm local time, every Thursday. Eacl flask (2.5liters) is sampled for about 2 minutes and pressurized to 40 PSI. This system automatically purges the flasks, dries the air sample, and fills the flasks. Aircraft-based sampling Samples are collected from the community inlet for as many as twelve elevations. The pilot triggers sampling when location and latitude have been reached. Each flask (0.75 liters) is sampled for about 2 minutes and pressurized to 40 PSI. The sampler has two components: (1) a rack mounted programmable compressor package (PCP, see picture below) and (2) a programmable flask package (PFP). Prior each flight, the pilot connects a new PFP to the PCP. An automatic test is then performed to check for leaks. After each flight the PFP is sent back to the laboratory for analysis of trace gases.

47 OTHER INSTRUMENTATION↗

Interferometric measurements of refractive index and dispersion at high pressure

Abstract We describe a high precision interferometer system to measure the pressure dependence of the refractive index and its dispersion in the diamond anvil cell (DAC). The reflective Fabry–Perot fringe patterns created by both a white light and a monochromatic beam are recorded to determine both the sample thickness and its index at the laser wavelength and to characterize the dispersion in the visible range. Advances in sample preparation, optical setup, and data analysis enable us to achieve $$10^{-4}$$ 10 - 4 random uncertainty, demonstrated with an air sample, a factor of five improvement over the best previous DAC measurement. New data on $${\text{H}}_{2}\text{O}$$ H 2 O liquid water and ice VI up to 2.21 GPa at room temperature illustrate how higher precision measurements of the index and its optical dispersion open up new opportunities to reveal subtle changes in the electronic structure of water at high pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

δ 13 C methane source signatures from tropical wetland and rice field emissions

The atmospheric methane (CH 4 ) burden is rising sharply, but the causes are still not well understood. One factor of uncertainty is the importance of tropical CH 4 emissions into the global mix. Isotopic signatures of major sources remain poorly constrained, despite their usefulness in constraining the global methane budget. Here, a collection of new δ 13 C CH 4 signatures is presented for a range of tropical wetlands and rice fields determined from air samples collected during campaigns from 2016 to 2020. Long-term monitoring of δ 13 C CH 4 in ambient air has been conducted at the Chacaltaya observatory, Bolivia and Southern Botswana. Both long-term records are dominated by biogenic CH 4 sources, with isotopic signatures expected from wetland sources. From the longer-term Bolivian record, a seasonal isotopic shift is observed corresponding to wetland extent suggesting that there is input of relatively isotopically light CH 4 to the atmosphere during periods of reduced wetland extent. This new data expands the geographical extent and range of measurements of tropical wetland and rice δ 13 C CH 4 sources and hints at significant seasonal variation in tropical wetland δ 13 C CH 4 signatures which may be important to capture in future global and regional models.

54 ENVIRONMENTAL SCIENCES↗

Selective Gas-Phase Capture of Explosives on Metal Beta-diketonate Polymers

A variety of metal beta-diketonate polymers were assessed for gas-phase selective retention of nitro aromatic, nitrate ester, and peroxide explosives. La(dihed) showed 13-42 times the retention for the nitro aromatics compared to a control column (identical column but lacking the 5% loading of the metal beta-diketonate polymer). Nitrate esters, the peroxide explosive TATP, and the taggant DMDNB were too strongly retained to elute from the La(dihed) column; however, these compounds could be eluted from the less retentive Cu(dihed) or Zn(dihed) columns. A Kovats index of 2124 for TNT the on the La(dihed) column compared to 1662 on the control illustrates the excellent discrimination against non-polar hydrocarbons, the principal matrix interference expected in air samples. A proof-of-principle experiment demonstrated analysis of an extrapolated 47 part-per trillion(v/v) of TNT in an air extract concentrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of volume resistivity/conductivity of metallic alloy in inhibited seawater by optical interferometry techniques

Optical interferometry techniques were used for the first time to measure the volume resistivity/conductivity of carbon steel samples in seawater with different concentrations of a corrosion inhibitor. In this investigation, the real-time holographic interferometry was carried out to measure the thickness of anodic dissolved layer or the total thickness, U{sub total}, of formed oxide layer of carbon steel samples during the alternating current (ac) impedance of the samples in blank seawater and in 5-20 ppm TROS C-70 inhibited seawater, respectively. In addition, a mathematical model was derived in order to correlate between the ac impedance (resistance) and the surface (orthogonal) displacement of the surface of the samples in solutions. In other words, a proportionality constant [resistivity ({rho}) or conductivity ({sigma})= 1/{rho}] between the determined ac impedance [by electrochemical impedance spectroscopy (EIS) technique] and the orthogonal displacement (by the optical interferometry techniques) was obtained. The value of the resistivity of the carbon steel sample in the blank seawater was found similar to the value of the resistivity of the carbon steel sample air, around 1 x 10{sup -5}{Omega} cm. On the contrary, the measured values of the resistivity of the carbon steel samples were 1.85 x 10{sup 7}, 3.35 x 10{sup 7}, and 1.7 x 10{sup 7}{Omega} cm in 5, 10, and 20 ppm TROS C-70 inhibited seawater solutions, respectively. Furthermore, the determined value range of {rho} of the formed oxide layers, from 1.7 x 10{sup 7} to 3.35 x 10{sup 7}{Omega} cm, is found in a reasonable agreement with the one found in literature for the Fe oxide-hydroxides, i.e., goethite ({alpha}-FeOOH) and for the lepidocrocite ({gamma}-FeOOH), 1 x 10{sup 9}{Omega} cm. The {rho} value of the Fe oxide-hydroxides, 1 x 10{sup 9}{Omega} cm, was found slightly higher than the {rho} value range of the formed oxide layer of the present study. This is because the former value was determined by a dc method rather than by an electromagnetic method, i.e., holographic interferometry with applications of EIS, i.e., ac method. As a result, erroneous measurements were recorded due to the introduction of heat to Fe oxide-hydroxides.

36 MATERIALS SCIENCE↗

ARM-LBNL-NOAA Flask Sampler for Carbon Cycle Gases

Data from ccg-flasks are sampled at the ARM SGP site and analyzed by the NOAA Earth System Research Laboratory (ESRL) as part of the NOAA Cooperative Global Air Sampling Network. Surface samples are collected from a 60m tower at the SGP Central Facility, usually once per week on one afternoon. The aircraft samples are collected approximately weekly from a chartered aircraft, and the collection flight path is centered over the tower where the surface samples are collected. Samples are collected by the ARM/LBNL Carbon Project. CO2 flask data contains measurements of CO2 concentration and CO2 stable isotope ratios (13CO2 and C18OO) from flasks collected at the SGP site. The flask samples are collected at 2m, 4m, 25m, and 60m along the 60m tower.

54 ENVIRONMENTAL SCIENCES↗

The background levels of atmospheric tritium concentration in the environment at NIFS Toki site of Japan

Atmospheric tritium concentrations at the National Inst. for Fusion Science (NIFS) Toki site of Japan, where the Large Helical Device (LHD) has been operating, were measured considering future deuterium plasma experiments and environmental safety. The major chemical forms of atmospheric tritium are water (HTO), hydrogen (HT) and methane (CH{sub 3}T). Average tritium concentrations of HTO, HT and CH{sub 3}T observed from January 2003 to March 2006 were 9.0 mBq/m{sup 3}, 9.0 mBq/m{sup 3} and 2.0 mBq/m{sup 3}, respectively. To examine about the systematic error of the air sampling device, we cross-checked with the sampling device of Kumamoto Univ.. The values obtained with both devices were almost consistent. The HTO concentration principally depends on humidity in air. The HTO concentration in the collected water and the HT concentration tend to show seasonal variation. The atmospheric tritium levels measured at Toki were consistent comparing with another environmental values measured in Japan. The present atmospheric tritium monitoring would be useful for safety consideration. (authors)

54 ENVIRONMENTAL SCIENCES↗

SCILLA nitrogen oxide (NOx) airborne data

Nitrogen oxides mixing ratios in ppb are measured using a Teledyne API Model T200UP. The analyzer uses chemiluminescence to determine NO concentration. Alternating measurement of the concentrations of total NOx (NO + NO2) and just NO are made by directing the sample through a blue light converter that photolyzes NO2 to NO and bypassing it, respectively, with the NO2 concentration calculated as the difference between the two. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, O3, and H2O) and an oxidation flow reactor. The NO, NO2, and NOx mixing ratios were recorded once per minute.

NOx concentration↗

SCILLA ozone (O3) airborne data

Ozone mixing ratios in ppb are measured using a Teledyne API Model T400U. The analyzer uses UV absorption at 254 nm to determine O3 concentration. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, NOx, and H2O) and an oxidation flow reactor. The data were recorded at 0.1 Hz.

Ozone concentration↗

Evaluation of Near Field Atmospheric Dispersion Around Nuclear Facilities Using a Lorentzian Distribution Methodology

Atmospheric dispersion modeling within the near field of a nuclear facility typically applies a building wake correction to the Gaussian plume model, whereby a point source is modeled as a plane source. The plane source results in greater near field dilution and reduces the far field effluent concentration. However, the correction does not account for the concentration profile within the near field. Receptors of interest, such as the maximally exposed individual, may exist within the near field and thus the realm of building wake effects. Furthermore, release parameters and displacement characteristics may be unknown, particularly during upset conditions. Therefore, emphasis is placed upon the need to analyze and estimate an enveloping concentration profile within the near field of a release. This investigation included the analysis of 64 air samples collected over 128 wk. Variables of importance were then derived from the measurement data, and a methodology was developed that allowed for the estimation of Lorentzian-based dispersion coefficients along the lateral axis of the near field recirculation cavity; the development of recirculation cavity boundaries; and conservative evaluation of the associated concentration profile. The results evaluated the effectiveness of the Lorentzian distribution methodology for estimating near field releases and emphasized the need to place air-monitoring stations appropriately for complete concentration characterization. Additionally, the importance of the sampling period and operational conditions were discussed to balance operational feedback and the reporting of public dose.

54 ENVIRONMENTAL SCIENCES↗

Structural, microstructural and surface properties of a specific CeO{sub 2}-Bi{sub 2}O{sub 3} multiphase system obtained at 600 {sup o}C

Polycrystalline samples of (1-x) CeO{sub 2}-x/2 Bi{sub 2}O{sub 3} phases, where x is the atom fraction of bismuth have been synthesized by the precipitation process and after the thermal treatment at 600 {sup o}C, under air. Samples are first characterized by the X-ray diffraction and scanning electron microscopy. To determine the samples specific surface areas, Brunauer-Emmett-Teller (BET) analyses have been performed. In the composition range 0{<=}x{<=}0.20, a cubic solid solution with fluorite structure is obtained. For compositions x comprised between 0.30 and 0.90, two types of T' (or {beta}') and T (or {beta}) tetragonal phases, similar to the well-known {beta}' or {beta} Bi{sub 2}O{sub 3} metastable structural varieties, are observed. However, the crystal cell volumes of these {beta}' or {beta} Bi{sub 2}O{sub 3} phases increase with the composition x in bismuth: this might be due to the presence of defects or substitution by cerium atoms, in the tetragonal lattices. Using X-ray diffraction profile analyses, correlations between bismuth composition x and crystal sizes or lattice distortions have been established. The solid-gas interactions between these polycrystalline materials and air-CH{sub 4} and air-CO flows have been studied as a function of temperature and composition x, using Fourier transform infrared (FTIR) analyses of the conversions of CH{sub 4} and CO gases into the CO{sub 2} gas. The transformations of CH{sub 4} and CO molecules as a function of time and temperature are determined through the intensities of FTIR CO{sub 2} absorption bands. Using the specific surface areas determined from BET analyses, these FTIR intensities have been normalized and compared. For all bismuth compositions, a low catalytic reactivity is observed with air-CH{sub 4} gas flows, while, for the highest bismuth compositions, a high catalytic reactivity is observed with air-CO gas flows. -- Graphical abstract: Catalytic efficiencies of CeO{sub 2}-Bi{sub 2}O{sub 3}system: catalytic actions on methane (on the left) or carbon monoxide (on the right) of (1-x)CeO{sub 2}-x/2 Bi{sub 2}O{sub 3} samples, as a function of the fraction x, and for fixed temperatures: on the vertical axis, the intensities of CO{sub 2} FTIR absorption bands are reported. Strong efficiency of bismuth rich samples for CO conversion. Display Omitted Research highlights: {yields} Stabilization of metastable polymorph Bi{sub 2}O{sub 3} phases in the mix system [(1-x)CeO{sub 2}+(x/2)Bi{sub 2}O{sub 3}] at 600 {sup o}C. {yields} Solid gas interactions between this system and air-CO or air-CH{sub 4} gas flows at various temperatures and bismuth compositions. {yields} High efficiency of bismuth rich samples to convert CO into CO{sub 2}.

36 MATERIALS SCIENCE↗

Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere

Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.

Fritz, Brad G.↗