Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Assessing Intra-arterial Complications of Planning and Treatment Angiograms for Y-90 Radioembolization

PurposeTo report hepatic arterial-related complications encountered during planning and treatment angiograms for radioembolization and understand any potential-associated risk factors.Materials and Methods518 mapping or treatment angiograms for 180 patients with primary or metastatic disease to the liver treated by Yttrium-90 radioembolization between 2/2010 and 12/2015 were retrospectively reviewed. Intra-procedural complications were recorded per SIR guidelines. Patient demographics, indication for treatment, prior exposure to chemotherapeutic agents, operator experience, and disease burden were reviewed. Technical variables including type of radioembolic (glass vs. resin microspheres), indication for angiography (mapping vs. treatment), variant anatomy, and attempts at coil embolization were also assessed.ResultsThirteen (13/518, 2.5%) arterial-related complications occurred in 13 patients. All but two complications resulted during transcatheter coil embolization to prevent non-target embolization. Complications included coil migration (n = 6), arterial dissection (n = 2), focal vessel perforation (n = 2), arterial thrombus (n = 2), and vasospasm prohibiting further arterial sub-selection (n = 1). Transarterial coiling was identified as a significant risk factor of complications on both univariate and multivariate regression analysis (odds ratio 7.8, P = 0.004). Usage of resin microspheres was also a significant risk factor (odds ratio 9.5, P = 0.042). No other technical parameters or pre-procedural variables were significant after adjusting for confounding on multivariate analysis (P > 0.05).ConclusionIntra-procedural hepatic arterial complications encountered during radioembolization were infrequent but occurred mainly during coil embolization to prevent non-target delivery to extra-hepatic arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ischemic Gastric Conditioning by Preoperative Arterial Embolization Before Oncologic Esophagectomy: A Single-Center Experience

PurposeSurgical esophagectomy is the gold standard treatment of early-stage esophageal cancer. The procedure is complicated with significant morbidity; the most severe complication being the anastomotic leakage. Anastomotic fistulas are reported in 5–25% of cases and are mainly due to gastric transplant ischemia. Here, we report our experience of ischemic pre-conditioning using preoperative arterial embolization (PreopAE) before esophagectomy.Materials and MethodsThe medical records of all patients who underwent oncologic esophagectomy from 2008 to 2015 were retrospectively reviewed. Patients were divided into two groups: patients who received PreopAE, and a control group of patients who did not benefit from ischemic pre-conditioning. The target arteries selected for PreopAE were the splenic artery, left gastric artery, and right gastric artery. Evaluation of the results was based on anastomotic leakage, postoperative mortality, technical success of PreopAE, and complications related to the embolization procedure.ResultsForty-six patients underwent oncologic esophagectomy with PreopAE and 13 patients did not receive ischemic conditioning before surgery. Thirty-eight PreopAE were successfully performed (83%), but right gastric artery embolization failed for 8 patients. Anastomotic leakage occurred in 6 PreopAE patients (13%) and in 6 patients (46%) in the control group (p = 0.02). The mortality rate was 2% in the PreopAE group and 23% in the control group (p = 0.03). Eighteen patients suffered from partial splenic infarction after PreopAE, all treated conservatively.ConclusionPreoperative ischemic conditioning by arterial embolization before oncologic esophagectomy seems to be effective in preventing anastomotic leakage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effects of MEK1/2 inhibition on cigarette smoke exposure-induced ET receptor upregulation in rat cerebral arteries

Cigarette smoking, a major stroke risk factor, upregulates endothelin receptors in cerebral arteries. The present study examined the effects of MEK1/2 pathway inhibition on cigarette smoke exposure-induced ET receptor upregulation. Rats were exposed to the secondhand smoke (SHS) for 8 weeks followed by intraperitoneal injection of MEK1/2 inhibitor, U0126 for another 4 weeks. The urine cotinine levels were assessed with high-performance liquid chromatography. Contractile responses of isolated cerebral arteries were recorded by a sensitive wire myograph. The mRNA and protein expression levels of receptor and MEK/ERK1/2 pathway molecules were examined by real-time PCR and Western blotting, respectively. Cerebral artery receptor localization was determined with immunohistochemistry. The results showed the urine cotinine levels from SHS exposure group were significantly higher than those from the fresh group. In addition, the MEK1/2 inhibitor, U0126 significantly reduced SHS exposure-increased ET{sub A} receptor mRNA and protein levels as well as contractile responses mediated by ET{sub A} receptors. The immunoreactivity of increased ET{sub A} receptor expression was primarily cytoplasmic in smooth muscle cells. In contrast, ET{sub B} receptor was noted in endothelial cells. However, the SHS-induced decrease in endothelium-dependent relaxation was unchanged after U0126 treatment. Furthermore, SHS increased the phosphorylation of MEK1/2 and ERK1/2 protein in cerebral arteries. By using U0126 could inhibit the phosphorylated ERK1/2 protein but not MEK1/2. Taken together, our data show that treatment with MEK1/2 pathway inhibitor offsets SHS exposure-induced ET{sub A} receptor upregulation in rat cerebral arteries. - Highlights: • Cigarette smoke exposure induces ET{sub A} receptor upregulation in rat cerebral arteries. • U0126 can alleviate the receptor upregulation. • The mechanism relies on MEK/ERK1/2 pathway activation. • We may provide a new target for the treatment of SHS-associated cerebral artery diseases.

60 APPLIED LIFE SCIENCES↗

Offline Arterial Signal Timing Optimization for Closely Spaced Intersections

The stop-and-go driving behavior at a busy arterial causes a significant amount of fuel waste and emissions that could be reduced. For closely spaced intersections, the traditional bottom-up signal timing approach could fail under high volumes when the queues reach the upstream intersections. A well-coordinated arterial should manage the queue length to prevent the control from failing. Traditionally, coordination among signalized intersections for an arterial means finding the good offsets for each intersection. The control of the intersections along an arterial can also be coordinated by optimizing splits. Splits impact the capacity of an intersection. Similar to the highway, the capacity drop could cause growing queues. This work is based on the Virtual Phase-Link (VPL) model, a street traffic model designed for online traffic model predictive control, to obtain a top-down offline arterial signal timing. The VPL-based model can guarantee capacity consistency in intersections along an arterial. We, therefore, adopted the VPL-based model and developed an offline signal timing optimization approach. The proposed timing derived from the VPL-based offline signal timing optimization showed very good results in simulation. We also collected field experiment data, which demonstrated overall energy reductions and speed improvements on some sections of the study arterial.

47 OTHER INSTRUMENTATION↗

Coronary artery wall imaging in mice using osmium tetroxide and micro-computed tomography (micro-CT)

The high spatial resolution of micro-computed tomography (micro-CT) is ideal for 3D imaging of coronary arteries in intact mouse heart specimens. Previously, micro-CT of mouse heart specimens utilized intravascular contrast agents that hardened within the vessel lumen and allowed a vascular cast to be made. However, for mouse coronary artery disease models, it is highly desirable to image coronary artery walls and highlight plaques. For this purpose, we describe an ex vivo contrast-enhanced micro-CT imaging technique based on tissue staining with osmium tetroxide (OsO{sub 4}) solution. As a tissue-staining contrast agent, OsO{sub 4} is retained in the vessel wall and surrounding tissue during the fixation process and cleared from the vessel lumens. Its high X-ray attenuation makes the artery wall visible in CT. Additionally, since OsO{sub 4} preferentially binds to lipids, it highlights lipid deposition in the artery wall. We performed micro-CT of heart specimens of 5- to 25-week-old C57BL/6 wild-type mice and 5- to 13-week-old apolipoprotein E knockout (apoE{sup -/-}) mice at 10 {mu}m resolution. The results show that walls of coronary arteries as small as 45 {mu}m in diameter are visible using a table-top micro-CT scanner. Similar image clarity was achieved with 1/2000th the scan time using a synchrotron CT scanner. In 13-week-old apoE mice, lipid-rich plaques are visible in the aorta. Our study shows that the combination of OsO{sub 4} and micro-CT permits the visualization of the coronary artery wall in intact mouse hearts.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of lung segments in computed tomography images using the Euclidean distance to the pulmonary artery

Purpose: Computed tomography (CT) imaging is the modality of choice for lung cancer diagnostics. With the increasing number of lung interventions on sublobar level in recent years, determining and visualizing pulmonary segments in CT images and, in oncological cases, reliable segment-related information about the location of tumors has become increasingly desirable. Computer-assisted identification of lung segments in CT images is subject of this work.Methods: The authors present a new interactive approach for the segmentation of lung segments that uses the Euclidean distance of each point in the lung to the segmental branches of the pulmonary artery. The aim is to analyze the potential of the method. Detailed manual pulmonary artery segmentations are used to achieve the best possible segment approximation results. A detailed description of the method and its evaluation on 11 CT scans from clinical routine are given.Results: An accuracy of 2–3 mm is measured for the segment boundaries computed by the pulmonary artery-based method. On average, maximum deviations of 8 mm are observed. 135 intersegmental pulmonary veins detected in the 11 test CT scans serve as reference data. Furthermore, a comparison of the presented pulmonary artery-based approach to a similar approach that uses the Euclidean distance to the segmental branches of the bronchial tree is presented. It shows a significantly higher accuracy for the pulmonary artery-based approach in lung regions at least 30 mm distal to the lung hilum.Conclusions: A pulmonary artery-based determination of lung segments in CT images is promising. In the tests, the pulmonary artery-based determination has been shown to be superior to the bronchial tree-based determination. The suitability of the segment approximation method for application in the planning of segment resections in clinical practice has already been verified in experimental cases. However, automation of the method accompanied by an evaluation on a larger number of test cases is required before application in the daily clinical routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiation of hepatic abscess from metastasis on contrast-enhanced dynamic computed tomography in patients with a history of extrahepatic malignancy: emphasis on dynamic change of arterial rim enhancement

Objectives: The objective of the study is to identify computed tomography (CT) findings that differentiate hepatic abscess from hepatic metastasis in a patient with a history of extrahepatic malignancy. Materials and methods: This retrospective study included 30 patients with 93 hepatic abscesses and 40 patients with 125 hepatic metastases who had a history of extrahepatic malignancy and underwent contrast-enhanced dynamic CT with arterial phase (AP) and portal venous phase (PVP). The diagnosis of hepatic abscess and hepatic metastasis was made using pathological confirmation or clinical diagnosis. Margin, patchy parenchymal enhancement, arterial rim enhancement, dynamic change of arterial rim enhancement, size discrepancy of lesions between arterial and portal phases, bile duct dilatation, perilesional hyperemia, and perilesional low density were evaluated by two radiologists independently. Significant findings for differentiating two groups were identified at univariate and multivariate analysis with nomogram for predicting hepatic abscess. Interobserver agreement was also analyzed for each variable. Results: Multivariate analysis revealed that patchy parenchymal enhancement (P < 0.001), arterial rim enhancement persistent through PVP (P < 0.001), and perilesional hyperemia (P = 0.013) were independent significant findings to predict hepatic abscess than metastasis. Among them, arterial rim enhancement persistent through PVP showed a highest odds ratio (OR 33.73) on multivariate analysis and a highest predictor point on a nomogram for predicting hepatic abscess. When two of these three criteria were combined, 80.7% (75/93) of hepatic abscess were correctly identified, with a specificity of 85.6% (107/125). When all three criteria were satisfied, specificity was up to 100% (125/125). Conclusions: At contrast-enhanced dynamic CT, patchy parenchymal enhancement, arterial rim enhancement persistent through PVP, perilesional hyperemia, and their combinations may be reliable CT features for differentiating hepatic abscess from metastasis in patients with a history of primary extrahepatic malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dyslipidemia Profiles in Patients with Peripheral Artery Disease

Purpose of Review: This review of the literature aims to discuss the evidence linking different lipid and apolipoprotein measures to peripheral artery disease. Recent Findings: Measures of atherogenic dyslipidemia, including elevations in total cholesterol and total cholesterol/high-density lipoprotein cholesterol as well as low levels of high-density lipoprotein cholesterol, are strongly associated with future risk of peripheral artery disease. Compared to coronary artery disease, there are fewer data showing an association between low-density lipoprotein cholesterol and future risk of peripheral artery disease. Novel lipid measures, including nuclear magnetic resonance-derived lipoproteins and oxidized lipids, may lead to better assessments of future peripheral artery disease risk. Summary: These data highlight the important differences between lipid risk factors for peripheral and coronary artery disease. Improved understanding of these distinctions may lead to new therapeutic options for patients with peripheral artery disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Heart and Coronary Artery Doses Associated With Intensity-Modulated Radiotherapy Versus Three-Dimensional Conformal Radiotherapy for Distal Esophageal Cancer

Purpose: To compare heart and coronary artery radiation exposure using intensity-modulated radiotherapy (IMRT) vs. four-field three-dimensional conformal radiotherapy (3D-CRT) treatment plans for patients with distal esophageal cancer undergoing chemoradiation. Methods and Materials: Nineteen patients with distal esophageal cancers treated with IMRT from March 2007 to May 2008 were identified. All patients were treated to 50.4 Gy with five-field IMRT plans. Theoretical 3D-CRT plans with four-field beam arrangements were generated. Dose-volume histograms of the planning target volume, heart, right coronary artery, left coronary artery, and other critical normal tissues were compared between the IMRT and 3D-CRT plans, and selected parameters were statistically evaluated using the Wilcoxon rank-sum test. Results: Intensity-modulated radiotherapy treatment planning showed significant reduction (p < 0.05) in heart dose over 3D-CRT as assessed by average mean dose (22.9 vs. 28.2 Gy) and V30 (24.8% vs. 61.0%). There was also significant sparing of the right coronary artery (average mean dose, 23.8 Gy vs. 35.5 Gy), whereas the left coronary artery showed no significant improvement (mean dose, 11.2 Gy vs. 9.2 Gy), p = 0.11. There was no significant difference in percentage of total lung volume receiving at least 10, 15, or 20 Gy or in the mean lung dose between the planning methods. There were also no significant differences observed for the kidneys, liver, stomach, or spinal cord. Intensity-modulated radiotherapy achieved a significant improvement in target conformity as measured by the conformality index (ratio of total volume receiving 95% of prescription dose to planning target volume receiving 95% of prescription dose), with the mean conformality index reduced from 1.56 to 1.30 using IMRT. Conclusions: Treatment of patients with distal esophageal cancer using IMRT significantly decreases the exposure of the heart and right coronary artery when compared with 3D-CRT. Long-term studies are necessary to determine how this will impact on development of coronary artery disease and other cardiac complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of breast arterial calcification using full field digital mammography

Breast arterial calcification is commonly detected on some mammograms. Previous studies indicate that breast arterial calcification is evidence of general atherosclerotic vascular disease and it may be a useful marker of coronary artery disease. It can potentially be a useful tool for assessment of coronary artery disease in women since mammography is widely used as a screening tool for early detection of breast cancer. However, there are currently no available techniques for quantification of calcium mass using mammography. The purpose of this study was to determine whether it is possible to quantify breast arterial calcium mass using standard digital mammography. An anthropomorphic breast phantom along with a vessel calcification phantom was imaged using a full field digital mammography system. Densitometry was used to quantify calcium mass. A calcium calibration measurement was performed at each phantom thickness and beam energy. The known (K) and measured (M) calcium mass on 5 and 9 cm thickness phantoms were related by M=0.964K-0.288 mg (r=0.997 and SEE=0.878 mg) and M=1.004K+0.324 mg (r=0.994 and SEE=1.32 mg), respectively. The results indicate that accurate calcium mass measurements can be made without correction for scatter glare as long as careful calcium calibration is made for each breast thickness. The results also indicate that composition variations and differences of approximately 1 cm between calibration phantom and breast thickness introduce only minimal error in calcium measurement. The uncertainty in magnification is expected to cause up to 5% and 15% error in calcium mass for 5 and 9 cm breast thicknesses, respectively. In conclusion, a densitometry technique for quantification of breast arterial calcium mass was validated using standard full field digital mammography. The results demonstrated the feasibility and potential utility of the densitometry technique for accurate quantification of breast arterial calcium mass using standard digital mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonrigid registration-based coronary artery motion correction for cardiac computed tomography

Purpose: X-ray computed tomography angiography (CTA) is the modality of choice to noninvasively monitor and diagnose heart disease with coronary artery health and stenosis detection being of particular interest. Reliable, clinically relevant coronary artery imaging mandates high spatiotemporal resolution. However, advances in intrinsic scanner spatial resolution (CT scanners are available which combine nearly 900 detector columns with focal spot oversampling) can be tempered by motion blurring, particularly in patients with unstable heartbeats. As a result, recently numerous methods have been devised to improve coronary CTA imaging. Solutions involving hardware, multisector algorithms, or {beta}-blockers are limited by cost, oversimplifying assumptions about cardiac motion, and populations showing contraindications to drugs, respectively. This work introduces an inexpensive algorithmic solution that retrospectively improves the temporal resolution of coronary CTA without significantly affecting spatial resolution. Methods: Given the goal of ruling out coronary stenosis, the method focuses on 'deblurring' the coronary arteries. The approach makes no assumptions about cardiac motion, can be used on exams acquired at high heart rates (even over 75 beats/min), and draws on a fast and accurate three-dimensional (3D) nonrigid bidirectional labeled point matching approach to estimate the trajectories of the coronary arteries during image acquisition. Motion compensation is achieved by employing a 3D warping of a series of partial reconstructions based on the estimated motion fields. Each of these partial reconstructions is created from data acquired over a short time interval. For brevity, the algorithm 'Subphasic Warp and Add' (SWA) reconstruction. Results: The performance of the new motion estimation-compensation approach was evaluated by a systematic observer study conducted using nine human cardiac CTA exams acquired over a range of average heart rates between 68 and 86 beats/min. Algorithm performance was based-lined against exams reconstructed using standard filtered-backprojection (FBP). The study was performed by three experienced reviewers using the American Heart Association's 15-segment model. All vessel segments were evaluated to quantify their viability to allow a clinical diagnosis before and after motion estimation-compensation using SWA. To the best of the authors' knowledge this is the first such observer study to show that an image processing-based software approach can improve the clinical diagnostic value of CTA for coronary artery evaluation. Conclusions: Results from the observer study show that the SWA method described here can dramatically reduce coronary artery motion and preserve real pathology, without affecting spatial resolution. In particular, the method successfully mitigated motion artifacts in 75% of all initially nondiagnostic coronary artery segments, and in over 45% of the cases this improvement was enough to make a previously nondiagnostic vessel segment clinically diagnostic.

60 APPLIED LIFE SCIENCES↗

Arterial Pressure Gradients during Upright Posture and 30 deg Head Down Tilt

Gravity alters local blood pressure within the body so that arterial pressures in the head and foot are lower and higher, respectively, than that at heart level. Furthermore, vascular responses to local alterations of arterial pressure are probably important to maintain orthostatic tolerance upon return to the Earth after space flight. However, it has been difficult to evaluate the body's arterial pressure gradient due to the lack of noninvasive technology. This study was therefore designed to investigate whether finger arterial pressure (FAP), measured noninvasively, follows a normal hydrostatic pressure gradient above and below heart level during upright posture and 30 deg head down tilt (HDT). Seven healthy subjects gave informed consent and were 19 to 52 years old with a height range of 158 to 181 cm. A Finapres device measured arterial pressure at different levels of the body by moving the hand from 36 cm below heart level (BH) to 72 cm above heart level (AH) in upright posture and from 36 cm BH to 48 cm AH during HDT in increments of 12 cm. Mean FAP creased by 85 mmHg transitioning from BH to AH in upright posture, and the pressure gradient calculated from hydrostatic pressure difference (rho(gh)) was 84 mmHg. In HDT, mean FAP decreased by 65 mmHg from BH to AH, and the calculated pressure gradient was also 65 mmHg. There was no significant difference between the measured FAP gradient and the calculated pressure gradient, although a significant (p = 0.023) offset was seen for absolute arterial pressure in upright posture. These results indicate that arterial pressure at various levels can be obtained from the blood pressure at heart level by calculating rho(gh) + an offset. The offset equals the difference between heart level and the site of measurement. In summary, we conclude that local blood pressure gradients can be measured by noninvasive studies of FAP.

Sanchez, E. R↗

Strength training reduces arterial blood pressure but not sympathetic neural activity in young normotensive subjects

The effects of resistance training on arterial blood pressure and muscle sympathetic nerve activity (MSNA) at rest have not been established. Although endurance training is commonly recommended to lower arterial blood pressure, it is not known whether similar adaptations occur with resistance training. Therefore, we tested the hypothesis that whole body resistance training reduces arterial blood pressure at rest, with concomitant reductions in MSNA. Twelve young [21 +/- 0.3 (SE) yr] subjects underwent a program of whole body resistance training 3 days/wk for 8 wk. Resting arterial blood pressure (n = 12; automated sphygmomanometer) and MSNA (n = 8; peroneal nerve microneurography) were measured during a 5-min period of supine rest before and after exercise training. Thirteen additional young (21 +/- 0.8 yr) subjects served as controls. Resistance training significantly increased one-repetition maximum values in all trained muscle groups (P < 0.001), and it significantly decreased systolic (130 +/- 3 to 121 +/- 2 mmHg; P = 0.01), diastolic (69 +/- 3 to 61 +/- 2 mmHg; P = 0.04), and mean (89 +/- 2 to 81 +/- 2 mmHg; P = 0.01) arterial blood pressures at rest. Resistance training did not affect MSNA or heart rate. Arterial blood pressures and MSNA were unchanged, but heart rate increased after 8 wk of relative inactivity for subjects in the control group (61 +/- 2 to 67 +/- 3 beats/min; P = 0.01). These results indicate that whole body resistance exercise training might decrease the risk for development of cardiovascular disease by lowering arterial blood pressure but that reductions of pressure are not coupled to resistance exercise-induced decreases of sympathetic tone.

NASA Discipline Neuroscience↗

Interactions between CO2 chemoreflexes and arterial baroreflexes

We studied interactions between CO2 chemoreflexes and arterial baroreflexes in 10 supine healthy young men and women. We measured vagal carotid baroreceptor-cardiac reflexes and steady-state fast Fourier transform R-R interval and photoplethysmographic arterial pressure power spectra at three arterial pressure levels (nitroprusside, saline, and phenylephrine infusions) and three end-tidal CO2 levels (3, 4, and 5%, fixed-frequency, large-tidal-volume breathing, CO2 plus O2). Our study supports three principal conclusions. First, although low levels of CO2 chemoreceptor stimulation reduce R-R intervals and R-R interval variability, statistical modeling suggests that this effect is indirect rather than direct and is mediated by reductions of arterial pressure. Second, reductions of R-R intervals during hypocapnia reflect simple shifting of vagally mediated carotid baroreflex responses on the R-R interval axis rather than changes of baroreflex gain, range, or operational point. Third, the influence of CO2 chemoreceptor stimulation on arterial pressure (and, derivatively, on R-R intervals and R-R interval variability) depends critically on baseline arterial pressure levels: chemoreceptor effects are smaller when pressure is low and larger when arterial pressure is high.

NASA Discipline Cardiopulmonary↗

Relationship of 133Xe cerebral blood flow to middle cerebral arterial flow velocity in men at rest

Cerebral blood flow (CBF) was measured by 133Xe clearance simultaneously with the velocity of blood flow through the left middle cerebral artery (MCA) over a wide range of arterial PCO2 in eight normal men. Average arterial PCO2, which was varied by giving 4% and 6% CO2 in O2 and by controlled hyperventilation on O2, ranged from 25.3 to 49.9 mm Hg. Corresponding average values of global CBF15 were 27.2 and 65.0 ml 100 g min-1, respectively, whereas MCA blood-flow velocity ranged from 42.8 to 94.2 cm/s. The relationship of CBF to MCA blood-flow velocity over the imposed range of arterial PCO2 was described analytically by a parabola with the equation: CBF = 22.8 - 0.17 x velocity + 0.006 x velocity2 The observed data indicate that MCA blood-flow velocity is a useful index of CBF response to change in arterial PCO2 during O2 breathing at rest. With respect to baseline values measured while breathing 100% O2 spontaneously, percent changes in velocity were significantly smaller than corresponding percent changes in CBF at increased levels of arterial PCO2 and larger than CBF changes at the lower arterial PCO2. These observed relative changes are consistent with MCA vasodilation at the site of measurement during exposure to progressive hypercapnia and also during extreme hyperventilation hypocapnia.

NASA Discipline Cardiopulmonary↗

Vapor resistant arteries

A vapor block resistant liquid artery structure for heat pipes. A solid tube artery with openings is encased in the sintered material of a heat pipe wick. The openings are limited to that side of the artery which is most remote from the heat source. The liquid in the artery can thus exit the artery through the openings and wet the sintered sheath, but vapor generated at the heat source is unlikely to move around the solid wall of the artery and reverse its direction in order to penetrate the artery through the openings. An alternate embodiment uses finer pore size wick material to resist vapor entry.

Shaubach, Robert M.↗

Vapor resistant arteries

A vapor block resistant liquid artery structure for heat pipes. A solid tube artery with openings is encased in the sintered material of a heat pipe wick. The openings are limited to that side of the artery which is most remote from the heat source. The liquid in the artery can thus exit the artery through the openings and wet the sintered sheath, but vapor generated at the heat source is unlikely to move around the solid wall of the artery and reverse its direction in order to penetrate the artery through the openings. An alternate embodiment uses finer pore size wick material to resist vapor entry.

Shaubach, Robert M.↗

Arterial endothelial function measurement method and apparatus

A "relaxoscope" (100) detects the degree of arterial endothelial function. Impairment of arterial endothelial function is an early event in atherosclerosis and correlates with the major risk factors for cardiovascular disease. An artery (115), such as the brachial artery (BA) is measured for diameter before and after several minutes of either vasoconstriction or vasorelaxation. The change in arterial diameter is a measure of flow-mediated vasomodification (FMVM). The relaxoscope induces an artificial pulse (128) at a superficial radial artery (115) via a linear actuator (120). An ultrasonic Doppler stethoscope (130) detects this pulse 10-20 cm proximal to the point of pulse induction (125). The delay between pulse application and detection provides the pulse transit time (PTT). By measuring PTT before (160) and after arterial diameter change (170), FMVM may be measured based on the changes in PTT caused by changes in vessel caliber, smooth muscle tone and wall thickness.

47 OTHER INSTRUMENTATION↗