Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APERTURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Aperture modulated, translating bed total body irradiation

Purpose: Total body irradiation (TBI) techniques aim to deliver a uniform radiation dose to a patient with an irregular body contour and a heterogeneous density distribution to within {+-}10% of the prescribed dose. In the current article, the authors present a novel, aperture modulated, translating bed TBI (AMTBI) technique that produces a high degree of dose uniformity throughout the entire patient. Methods: The radiation beam is dynamically shaped in two dimensions using a multileaf collimator (MLC). The irregular surface compensation algorithm in the Eclipse treatment planning system is used for fluence optimization, which is performed based on penetration depth and internal inhomogeneities. Two optimal fluence maps (AP and PA) are generated and beam apertures are created to deliver these optimal fluences. During treatment, the patient/phantom is translated on a motorized bed close to the floor (source to bed distance: 204.5 cm) under a stationary radiation beam with 0 deg. gantry angle. The bed motion and dynamic beam apertures are synchronized. Results: The AMTBI technique produces a more homogeneous dose distribution than fixed open beam translating bed TBI. In phantom studies, the dose deviation along the midline is reduced from 10% to less than 5% of the prescribed dose in the longitudinal direction. Dose to the lung is reduced by more than 15% compared to the unshielded fixed open beam technique. At the lateral body edges, the dose received from the open beam technique was 20% higher than that prescribed at umbilicus midplane. With AMTBI the dose deviation in this same region is reduced to less than 3% of the prescribed dose. Validation of the technique was performed using thermoluminescent dosimeters in a Rando phantom. Agreement between calculation and measurement was better than 3% in all cases. Conclusions: A novel, translating bed, aperture modulated TBI technique that employs dynamically shaped MLC defined beams is shown to improve dose uniformity in three dimensions. In comparison with the fixed open beam TBI technique, homogeneity of dose distribution is greatly improved.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-583: Comparison of EBT3 Radiochromic Film Densitometry with Narrow Bandwidth LED Source in Point, Slot and Full Aperture Geometries

Purpose: Film densitometers optimized for radiochromic EBT3 film are not commercially available and flatbed document scanners are limited by broad spectral overlap of the red green and blue channels and polarization effects. Non-polarized, narrow bandwith, intensity stabilized light emitting diode (LED) light sources were constructed and transmission measurements compared for point, slot and full aperture geometries. Methods: LED’s with 10 nm bandwidths were focused to 1 mm spots for point scanning. The LED’s back-illuminated a 6 mm diameter diffuser near the focal point of a 25 cm diameter Fresnel lens for slot and full aperture transmission imaging. Films were located at the aperture plane, 15 cm from the lens and imaged with a 16 bit digital camera with 50 mm lens. Sheets, 10×8 cm, were irradiated to 25 Gy with a 4×4 cm 6 MV photon beam. Transmission measurements with a 633nm, linearly polarized laser were used as lowacceptance angle reference geometry. Results: LED intensity stabilized to <1% within one minute of startup. The useful transmission range increased as the acceptance angle decreased, laser(∼2%)> spot(∼3%)> slot(∼5%)> full aperture(∼10%). The Fresnel lens introduced a 4-fold polarization symmetry that increased radially causing a 2% change in transmission at 10 cm from the optic axis for EBT3 film. Polarized spot densitometer and laser transmission were similar. Conclusion: Spectrally filtered LED sources were effective for transmission measurements of radiochromic films. Because of polarization sensitivity of EBT3 film, the scanning spot geometry is the most general for measuring unpolarised transmission of larger film sizes, ie > 15×15 cm. Due to EBT3 film scatter, spot scanning should provide the most accurate profiles of high dose gradients, for a given acceptance angle. The spot scanning densitometer provided useful transmission to ∼5, 25, >25 Gy with 635, 590 and 530 nm light respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IMAGING ANALYSIS OF THE HARD X-RAY TELESCOPE ProtoEXIST2 AND NEW TECHNIQUES FOR HIGH-RESOLUTION CODED-APERTURE TELESCOPES

Wide-field (≳100 deg{sup 2}) hard X-ray coded-aperture telescopes with high angular resolution (≲2′) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation and study of a multi-aperture antenna system final report, 1 jan. - 1 apr. 1964

This investigation was concerned with a multiple aperture adaptive antenna system for application to receiving telemetered data from remote space vehicles or satellites. The primary criterion for determining the feasibility of such a system has been economic considerations, but of necessity many physical constraints imposed on both a single antenna and a multiple aperture system have been evaluated. These include such factors as acquisition and combining of signals, look angle, shadowing, propagation influences system spatial bandwidth, collimation, interference, doppler effects, reliability, and noise. Specific conclusions have been made for a system operating at a frequency of 2 Gc, but the system model adopted allows quick evaluation at other frequencies. At a frequency of 2Gc, the crossover point between a single antenna or a multiple aperture configuration occurs for an 85 foot reflector. However this transition region is not critical. For lunar range communications a single antenna appears to be the most economical, whereas at interplanetary ranges aperture equivalents of around 400 feet are required and achieved by arraying eight 142 foot antennas.

TELEMETRY↗

Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU /flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

00000↗

The Solid Angle for a Spherical Surface Source and a Detector with an Arbitrary Aperture: An Elegant Proof

It has previously been proven that the solid angle (or geometry factor, also called the geometrical efficiency) for a spherically symmetric outward-directed surface source with an arbitrary radius and polar angle distribution and an arbitrary detector aperture is equal to the solid angle for an isotropic point source located at the center of the spherical surface source and the same detector aperture. The solid angle for a source-detector system is the fraction of source particles that enter the detector aperture and so it is not purely geometric-the angular distribution of the source is a factor. The previous proof relied on an analytic transport-theory (streaming only) calculation of the solid angle Ω for a spherically symmetric surface source and a point detector. In this paper, a new, more elegant proof is given. Since the net current across any portion of a plane that intersects the center of a spherical surface source is zero, the solid angle for a spherical surface source with any polar angle distribution and a uniform azimuthal angle distribution and any detector aperture is equal to the solid angle for an isotropic point source and the same detector. This insight obviates the calculus and trigonometry involved in the previous proof. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of Dynamic Aperture of PEP-X Baseline Design

SLAC is developing a long-range plan to transfer the evolving scientific programs at SSRL from the SPEAR3 light source to a much higher performing photon source. Storage ring design is one of the possibilities that would be housed in the 2.2-km PEP-II tunnel. The design goal of PEPX storage ring is to approach an optimal light source design with horizontal emittance less than 100 pm and vertical emittance of 8 pm to reach the diffraction limit of 1-{angstrom} x-ray. The low emittance design requires a lattice with strong focusing leading to high natural chromaticity and therefore to strong sextupoles. The latter caused reduction of dynamic aperture. The dynamic aperture requirement for horizontal injection at injection point is about 10 mm. In order to achieve the desired dynamic aperture the transverse non-linearity of PEP-X is studied. The program LEGO is used to simulate the particle motion. The technique of frequency map is used to analyze the nonlinear behavior. The effect of the non-linearity is tried to minimize at the given constrains of limited space. The details and results of dynamic aperture optimization are discussed in this paper.

43 PARTICLE ACCELERATORS↗

Scale–Bridging in Three–Dimensional Fracture Networks: Characterizing the Effects of Variable Fracture Apertures on Network–Scale Flow Channelization

Here, we incorporate observations of real fracture aperture variability observed in laboratory experiments into an ensemble of three-dimensional discrete fracture network (DFN) simulations to characterize how variations of this micro-scale feature can influence flow and transport behavior at the network scale. A shear fracture is created within a Marcellus shale sample, and the fracture aperture is measured using a triaxial direct-shear device coupled with real-time X-ray imaging at in-situ stress conditions. We construct an ensemble of fracture networks based on natural fractures in Marcellus shale and project regions of the experimental aperture field onto each fracture in the networks. Our calculations demonstrate that the degree of flow channelization, a network-scale flow field structure, is dramatically increased by local changes in the aperture field that in turn affects flow and transport properties.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

Velocity Dispersion σ aper Aperture Corrections as a Function of Galaxy Properties from Integral-field Stellar Kinematics of 10,000 MaNGA Galaxies

Abstract The second moment of the stellar velocity within the effective radius, denoted by σ e 2 , is a crucial quantity in galaxy studies, as it provides insight into galaxy properties and their mass distributions. However, large spectroscopic surveys typically do not measure σ e directly, instead providing σ aper , the second moment of the stellar velocity within a fixed fiber aperture. In this paper, we derive an empirical aperture correction formula, given by σ aper / σ e = ( R aper / R e ) α , using spatially resolved stellar kinematics extracted from approximately 10,000 Sloan Digital Sky Survey–Mapping Nearby Galaxies at Apache Point Observatory integral field unit observations. Our analysis reveals a strong dependence of α on the r -band absolute magnitude M r , g – i color, and Sérsic index n Ser , where α values are lower for brighter, redder galaxies with higher Sérsic indices. Our results demonstrate that the aperture correction derived from previous literature on early-type galaxies cannot be applied to predict the aperture corrections for galaxies with intermediate Sérsic indices. We provide a lookup table of α values for different galaxy types, with parameters in the ranges of −18 > M r > −24, 0.4 < g – i < 1.6, and 0 < n Ser < 8. A Python script is provided to obtain the correction factors from the lookup table.

Astronomy & Astrophysics↗

Field Quality Study of a 1-m-Long Single-Aperture 11-T Nb$_3$Sn Dipole Model for LHC Upgrades

FNAL and CERN are carrying out a joint R&D program with the goal of building a 5.5-m-long twin-aperture 11-T Nb_3Sn dipole prototype that is suitable for installation in the LHC. An important part of the program is the development and test of a series of short single-aperture and twin-aperture dipole models with a nominal field of 11 T at the LHC operation current of 11.85 kA and 20% margin. This paper presents the results of magnetic measurements of a 1-m-long single-aperture Nb_3Sn dipole model fabricated and tested recently at FNAL, including geometrical field harmonics and effects of coil magnetization and iron yoke saturation.

43 PARTICLE ACCELERATORS↗

11 T Twin-Aperture Nb$_3$Sn Dipole Development for LHC Upgrades

FNAL and CERN are developing a twin-aperture 11 T Nb3Sn dipole suitable for installation in the LHC. This paper describes the design and parameters of the 11 T dipole developed at FNAL for the LHC upgrades in both single-aperture and twin-aperture configurations, and presents details of the constructed dipole models. Results of studies of magnet quench performance, quench protection and magnetic measurements performed using short 1 m long coils in the dipole mirror and single-aperture configurations are reported and discussed.

43 PARTICLE ACCELERATORS↗

Design and Assembly of a Large-Aperture Nb 3 Sn Cos-Theta Dipole Coil With Stress Management in Dipole Mirror Configuration

The stress-management cos-theta (SMCT) coil is a new concept which has been proposed and is being developed at Fermilab in the framework of US Magnet Development Program (US-MDP) for high-field and/or large-aperture accelerator magnets based on low-temperature and high-temperature superconductors. The SMCT structure is used to reduce large coil deformations under the Lorentz forces and, thus, the excessively large strains and stresses in the coil. A large-aperture Nb 3 Sn SMCT dipole coil has been developed and fabricated at Fermilab to demonstrate and test the SMCT concept including coil design, fabrication technology and performance. The first SMCT coil has been assembled with 60-mm aperture Nb 3 Sn coil inside a dipole mirror configuration and will be tested separately and in series with the insert coil. Here this paper summarizes the large-aperture SMCT coil design and parameters and reports the coil fabrication steps and its assembly in dipole mirror configuration.

43 PARTICLE ACCELERATORS↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

Effect of the photon lifetime on the characteristics of 850-nm vertical-cavity surface-emitting lasers with fully doped distributed Bragg reflectors and an oxide current aperture

The effect of the photon lifetime in an optical microcavity on the characteristics of 850-nm vertical-cavity surface-emitting lasers (VCSELs) with fully doped distributed Bragg reflectors (DBRs) and an oxide current aperture is studied. The photon lifetime in the microcavity is controlled by varying the upper DBR reflectance. It is found that the speed of VCSELs with a current-aperture diameter of 10 μm is mainly limited by the self-heating effect, despite an increase in the relaxation-oscillation damping coefficient with increasing photon lifetime in the microcavity. At the same time, the higher level of internal optical loss in lasers with a current-aperture diameter of 1.5 μm leads to dominance of the effect of relaxation-oscillation damping independently of the radiation output loss. In the case of devices with a current-aperture diameter of 5.5 μm, both mechanisms limiting the speed operate, which allow an increase in the VCSEL effective modulation frequency from 21 to 24 GHz as the photon lifetime decreases from 3.7 to 0.8 ps.

36 MATERIALS SCIENCE↗

Large Aperture and Wedged Multilayer Laue Lens for X-ray Nanofocusing

Diffraction optics fabricated from multilayers offer an intriguing alternative to lithography-based zone plates due to their advantages of virtually limitless aspect ratio and extremely small feature size. However, other issues, intrinsic to thin-film deposition, such as film stress and deposition rate instability, for example, limit the total achievable aperture. Over the last decade, Multilayer Laue Lens (MLLs) have progressed from a mere curiosity with initial aperture sizes in the 3–10 μm range, to real beamline-deployed optics with apertures in the 40–50 μm range (X. Huang, et al., Scientific Reports 3, 3562 (2013); E. Nazaretski, et al., Rev. Sci. Instrum. 85, 033707 (2014); E. Nazaretski, et al., Journal of Synchrotron Radiation 24, 1113 (2017)). By optimizing deposition conditions and incorporating new materials, MLLs have now broken the 100 μm thickness milestone. A flat WSi 2 /Al–Si MLL with a deposition thickness of 102 μm, the largest MLL to date, is reviewed. New large aperture wedged MLLs (wMLL), which were first fabricated by APS in 2006 using the WSi 2 /Si material system, are presented which demonstrate high focusing efficiency across a broad energy range. Furthermore, these results confirm findings by other groups who have also independently fabricated wMLL (A. J. Morgan, et al., Scientific Reports 5, 9892 (2015); S. Bajt, et al., Nature Light: Science and Applications 7, 17162 (2017)) based on a similar material system.

47 OTHER INSTRUMENTATION↗

Development and test of a large-aperture Nb3Sn cos-theta dipole coil with stress management

The stress-managed cos-theta (SMCT) coil is a new concept which was proposed and is being developed at Fermilab in the framework of US Magnet Development Program (US-MDP) for high-field and/or large-aperture accelerator magnets based on low-temperature and high-temperature superconductors. A 120-mm aperture two-layer Nb3Sn SMCT dipole coil has been developed at Fermilab to demonstrate and test the SMCT concept including coil design, fabrication technology and performance. The first SMCT demo coil was fabricated and assembled with 60-mm aperture Nb3Sn coil inside a dipole mirror configuration and tested separately and in series with the insert coil. This paper summarizes the design, parameters, and quench performance of the 120-mm aperture SMCT coil in a dipole mirror configuration.

43 PARTICLE ACCELERATORS↗

Large aperture optics performance

The objective of this work was to improve understanding of the damage performance of large aperture optics under conditions similar to those experienced in large, megajouleclass laser systems. We evaluated large optics at full aperture over a wide range of fluence and intensity, with unconverted light present and with statistical fluctuations typical of large aperture lasers. Specialized optomechanical hardware which edgeilluminated the optics was coupled with a new flaw inspection system and extensive laser diagnostics in an existing large aperture laser system called the Precision Diagnostic System (PDS) to allow in situ analysis of damage initiation and growth. Nearby upstream (-z) flaws on neighboring optics was found to be a major contributor to optics damage. Based on results of the initial experiments, improvements were made in the optical configuration and in the optics themselves that significantly reduced their susceptibility to laser-induced damage.

42 ENGINEERING↗