Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANIMAL PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Experimental Liver Embolization with Four Different Spherical Embolic Materials: Impact on Inflammatory Tissue and Foreign Body Reaction

We sought to describe and compare material specific inflammatory and foreign body reactions after porcine liver embolization with spherical embolic agents. In 40 animals, superselective liver embolization was performed with four different spherical embolic agents of various sizes: 40-120 {mu}m (Embozene, Embosphere), and 100-300 {mu}m, 500-700 {mu}m, and 700-900 {mu}m (Embozene, Embosphere, Bead Block, and Contour SE, respectively). After 4 or 12 weeks, inflammatory reactions were evaluated microscopically according to the Banff 97 classification. For investigation of foreign body reactions, a newly designed giant cell score was applied. Banff 97 and giant cell scores closely correlated. At 4 weeks, small Embosphere particles (100-300 {mu}m) had a significantly higher Banff 97 score than Embozene, Bead Block, and Contour SE of the corresponding size. After 12 weeks, the calculated differences were not statistically significant. Comparison between the 4-week results and the 12-week results revealed a statistically higher Banff 97 score for Embosphere 100-300 {mu}m after 4 weeks than after 12 weeks (P = 0.02). The overall foreign body reaction was pronounced after embolization with smaller particles, especially in small Embosphere particles. Giant cell numbers with Embosphere 100-300 {mu}m were statistically higher compared with the other materials of corresponding size (P < 0.0001). Inflammatory and giant cell reactions after embolization procedures depend on the embolic material. The overall inflammatory reaction was low. However, marked inflammation was associated with small Embosphere particles at 4 weeks, a finding that might be caused by the allogeneic overcoat. Correspondingly, giant cells indicating a foreign body reaction were more frequently associated with small particle sizes, especially after embolization with small Embosphere particles.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NAA TECHNIQUE FOR CLINICAL INVESTIGATION OF MICE IMMUNIZED WITH BOTHROP VENOM

In the present study Neutron Activation Analysis (NAA) technique was used to determine sodium concentration in whole blood of mice immunized with Bothrops venom. With this value it was possible to perform clinical investigation in this animal model using whole blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiobiology, Omics and Microdosimetry of Systemic and Targeted Radiotherapeutics Workshop

The Radiobiology, Omics and Microdosimetry of Systemic and Targeted Radiotherapeutics Workshop fostered engagement across disciplines on critical topics that impact the development of targeted radionuclide therapies, bringing together scientific and medical professionals actively involved in radiotherapeutic design, optimization testing, patient treatment, and clinical trials along with basic science researchers, whose novel techniques have the potential to further our understanding of targeted radionuclide therapy. Discussion of the applications of radiotherapeutics to pediatric and adult, brain, prostate and blood cancers, and metastatic disease allowed scientific research to be presented in the context of real-world medical applications and provided an important backdrop to the basic research performed in computers, laboratories, and animal facilities. The workshop format, presentations, and panel discussions were designed to consider a holistic approach to the development of systemic and targeted radiotherapies, integrating radiobiology and microdosimetry, biological assessments on the microscale, and physiologically relevant models of tumor and tissue microenvironments. Important needs highlighted in the workshop include better models to assess the biological effects of radionuclide therapy, novel strategies to target radiotherapeutics to disease sites with high specificity, and new dosimetry techniques that address the importance of tumor microenvironments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Senecavirus A Isolates Collected From the Environment of U.S. Sow Slaughter Plants

Vesicular disease caused by Senecavirus A (SVA) is clinically indistinguishable from foot-and-mouth disease (FMD) and other vesicular diseases of swine. When a vesicle is observed in FMD-free countries, a costly and time-consuming foreign animal disease investigation (FADI) is performed to rule out FMD. Recently, there has been an increase in the number of FADIs and SVA positive samples at slaughter plants in the U.S. The objectives of this investigation were to: (1) describe the environmental burden of SVA in sow slaughter plants; (2) determine whether there was a correlation between PCR diagnostics, virus isolation (VI), and swine bioassay results; and (3) phylogenetically characterize the genetic diversity of contemporary SVA isolates. Environmental swabs were collected from three sow slaughter plants (Plants 1-3) and one market-weight slaughter plant (Plant 4) between June to December 2020. Of the 426 samples taken from Plants 1-3, 304 samples were PCR positive and 107 were VI positive. There was no detection of SVA by PCR or VI at Plant 4. SVA positive samples were most frequently found in the summer (78.3% June-September, vs. 59.4% October-December), with a peak at 85% in August. Eighteen PCR positive environmental samples with a range of C t values were selected for a swine bioassay: a single sample infected piglets ( n = 2). A random subset of the PCR positive samples was sequenced; and phylogenetic analysis demonstrated co-circulation and divergence of two genetically distinct groups of SVA. These data demonstrate that SVA was frequently found in the environment of sow slaughter plants, but environmental persistence and diagnostic detection was not indicative of whether a sampled was infectious to swine. Consequently, a more detailed understanding of the epidemiology of SVA and its environmental persistence in the marketing chain is necessary to reduce the number of FADIs and aide in the development of control measures to reduce the spread of SVA.

59 BASIC BIOLOGICAL SCIENCES↗

Sleep-wake cycle of an unrestrained isolated chimpanzee under entrained and free running conditions.

Biorhythmic patterns of EEG activity - the sleep-wake cycle and the sleep cycle - were investigated in an unrestrained chimpanzee subjected to 30 days of isolation in a 4-ft cubical cage placed in a high performance sound isolation chamber. The animal received 10 days of 12 hours of light and 12 hours of dark, then 10 days of continuous light, followed by 10 more days of 12 hours of light and 12 hours of dark. The circadian sleep-wake rhythm and the wake and sleep phases of this rhythm during entrained and free running conditions were analyzed in terms of duration. The awake and nonREM sleep and REM sleep stages were also analyzed. In addition, the mean duration of the sleep cycle of the sleep phase was computed.

Mcnew, J. J.↗

Comparative Study in Laboratory Rats to Validate Sperm Quality Methods and Endpoints

Abstract The Naval Health Research Center, Detachment (Toxicology) performs toxicity studies in laboratory animals to characterize the risk of exposure to chemicals of Navy interest. Research was conducted at the Toxicology Detachment at WPAFB, OH in collaboration with Wright State University, Department of Biological Sciences for the validation of new bioassay methods for evaluating reproductive toxicity. The Hamilton Thorne sperm analyzer was used to evaluate sperm damage produced by exposure to a known testicular toxic agent, methoxyacetic acid and by inhalation exposure to JP-8 and JP-5 in laboratory rats. Sperm quality parameters were evaluated (sperm concentration, motility, and morphology) to provide evidence of sperm damage. The Hamilton Thorne sperm analyzer utilizes a DNA specific fluorescent stain (similar to flow cytometry) and digitized optical computer analysis to detect sperm cell damage. The computer assisted sperm analysis (CASA) is a more rapid, robust, predictive and sensitive method for characterizing reproductive toxicity. The results presented in this poster report validation information showing exposure to methoxyacetic acid causes reproductive toxicity and inhalation exposure to JP-8 and JP-5 had no significant effects. The CASA method detects early changes that result in reproductive deficits and these data will be used in a continuing program to characterize the toxicity of chemicals, and combinations of chemicals, of military interest to formulate permissible exposure limits.

Price, W. A.↗

Invited review: what do we know about the effects of spaceflight on bone?

This review of the peer-reviewed literature focuses on the effects of spaceflight on bone. Studies performed in humans and laboratory animals have revealed abnormalities in bone and mineral metabolism that suggest that long-duration spaceflight will have detrimental effects on the skeleton. However, because of large gaps in our knowledge, it is not presently possible to estimate the magnitude of the health risk, individual variations in risk, effective countermeasures, or mechanism(s) of action. Specific recommendations are made for future research to ascertain risk and develop appropriate countermeasures.

NASA Discipline Musculoskeletal↗

Social Isolation Impacts Select Responses to Simulated Weightlessness

The rodent hindlimb unloading (HU) model was initially developed to simulate the cephalad fluid shift and musculoskeletal disuse in astronauts. Since then, the HU model has been applied to explore how other systems (e.g. immune, cardiovascular and CNS) respond to weightlessness. Most HU studies are performed with singly-housed animals, although social isolation also can substantially impact behavior and physiology, and therefore may confound HU experimental results. We hypothesized that relative to social housing, single housing exacerbates HU-induced dysfunction in select organ systems. We refined the standard NASA-Ames HU model to accommodate social housing in HU pairs, retaining advantageous features of traditional housing but using commercial off-the-shelf components to facilitate adoption by others. We conducted a 30 day HU experiment with adult, female C57Bl6/NJ mice that were either singly or socially housed. HU animals in both single and social HU housing displayed expected musculoskeletal deficits compared to housing matched, normally loaded (NL) controls. However, select immune, HPA axis, and CNS responses were differentially impacted by the HU social environment relative to NL controls. HU reduced % CD4+ T cells in singly-housed, but not socially-housed mice. Surprisingly, HU increased adrenal gland mass in socially-housed but not singly-housed mice, while social isolation increased adrenal gland mass in NL controls. HU also increased plasma corticosterone levels (day 30) in both singly and socially-housed mice. Thus, the social environment altered select adrenal and immune, but not musculoskeletal, responses to simulated weightlessness. We refine our original hypothesis since our results show combined stressors can mask, not only exacerbate, tissue responses to HU. These findings further expand the utility of the HU model for studying possible combined effects of the various spaceflight stressors.

Tahimic, Candice↗

CO2 Conversion By Nano Heaters

A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

54 ENVIRONMENTAL SCIENCES↗

Perceived control in rhesus monkeys (Macaca mulatta) - Enhanced video-task performance

This investigation was designed to determine whether perceived control effects found in humans extend to rhesus monkeys (Macaca mulatta) tested in a video-task format, using a computer-generated menu program, SELECT. Choosing one of the options in SELECT resulted in presentation of five trials of a corresponding task and subsequent return to the menu. In Experiments 1-3, the animals exhibited stable, meaningful response patterns in this task (i.e., they made choices). In Experiment 4, performance on tasks that were selected by the animals significantly exceeded performance on identical tasks when assigned by the experimenter under comparable conditions (e.g., time of day, order, variety). The reliable and significant advantage for performance on selected tasks, typically found in humans, suggests that rhesus monkeys were able to perceive the availability of choices.

Washburn, David A.↗

Tumor Resection Guided by Intraoperative Indocyanine Green Dye Fluorescence Angiography Results in Negative Surgical Margins and Decreased Local Recurrence in an Orthotopic Mouse Model of Osteosarcoma

Background: Surgical resection with negative margins is the foundation of extremity sarcoma management. Failure to achieve negative surgical margins can result in local recurrence (LR), a potentially devastating complication. Indocyanine green (ICG) is a US FDA-approved fluorophore previously used to guide carcinoma resections. We investigated the potential of ICG as an intraoperative guide during experimental sarcoma resection. Methods: Fifty 6-week-old immunocompetent Balb/c female mice received left proximal tibia paraphyseal injections of 5 × 10{sup 5} K7M2 murine osteosarcoma cells. Animals were separated into two groups (n = 25 each): (1) ICG-assisted surgical resection; and (2) no ICG-assisted resection. Resections were performed 4 weeks after primary tumor engraftment. All animals received 7.5 ug ICG via retro-orbital injection 12 h prior to surgery. ICG fluorescence measurements and clinical evaluations were performed 4 weeks after resection to detect LR. Results: Eleven of 25 animals from each group developed gross tumors. Four weeks after resection, group 1 had 0/11 tumor recurrences, while group 2 had recurrences in 9/11 (81.8%) experimental mice (p < 0.0002) (Fig. 2). There was a 100% NPV in group 1, and no tumor recurrence with fluorescence-free margins after the primary surgery. Group 2 had a 100% positive predictive value for the development of an LR if any fluorescent signal was present at the surgical margin after resection. Conclusion: Intraoperative ICG guidance led to reliably negative surgical margins and a diminished LR rate. Given the benign safety profile of ICG and its prior clinical success, these results could be immediately translatable to the clinical realm.

60 APPLIED LIFE SCIENCES↗

Design and Experimental Verification of Deployable/Inflatable Ultra-Lightweight Structures

Because launch cost of a space structural system is often proportional to the launch volume and mass and there is no significant gravity in space, NASA's space exploration programs and various science missions have stimulated extensive use of ultra-lightweight deployable/inflatable structures. These structures are named here as Highly Flexible Structures (HFSs) because they are designed to undergo large displacements, rotations, and/or buckling without plastic deformation under normal operation conditions. Except recent applications to space structural systems, HFSs have been used in many mechanical systems, civil structures, aerospace vehicles, home appliances, and medical devices to satisfy space limitations, provide special mechanisms, and/or reduce structural weight. The extensive use of HFSs in today's structural engineering reveals the need of a design and analysis software and a database system with design guidelines for practicing engineers to perform computer-aided design and rapid prototyping of HFSs. Also to prepare engineering students for future structural engineering requires a new and easy-to- understand method of presenting the complex mathematics of the modeling and analysis of HFSs. However, because of the high flexibility of HFSs, many unique challenging problems in the modeling, design and analysis of HFSs need to be studied. The current state of research on HFSs needs advances in the following areas: (1) modeling of large rotations using appropriate strain measures, (2) modeling of cross-section warpings of structures, (3) how to account for both large rotations and cross- section warpings in 2D (two-dimensional) and 1D structural theories, (4) modeling of thickness thinning of membranes due to inflation pressure, pretension, and temperature change, (5) prediction of inflated shapes and wrinkles of inflatable structures, (6) development of efficient numerical methods for nonlinear static and dynamic analyses, and (7) filling the gap between geometrically exact elastic analysis and elastoplastic analysis. The objectives of this research project were: (1) to study the modeling, design, and analysis of deployable/inflatable ultra-lightweight structures, (2) to perform numerical and experimental studies on the static and dynamic characteristics and deployability of HFSs, (3) to derive guidelines for designing HFSs, (4) to develop a MATLAB toolbox for the design, analysis, and dynamic animation of HFSs, and (5) to perform experiments and establish an adequate database of post-buckling characteristics of HFSs.

Pai, P. Frank↗

Simulating Scenes In Outer Space

Multimission Interactive Picture Planner, MIP, computer program for scientifically accurate and fast, three-dimensional animation of scenes in deep space. Versatile, reasonably comprehensive, and portable, and runs on microcomputers. New techniques developed to perform rapidly calculations and transformations necessary to animate scenes in scientifically accurate three-dimensional space. Written in FORTRAN 77 code. Primarily designed to handle Voyager, Galileo, and Space Telescope. Adapted to handle other missions.

Callahan, John D.↗

The value and potential of animal research in enabling astronaut health - Transition from Spacelab to Space Station Freedom

Maintaining astronaut health is a critical aspect of human space exploration. Three decades of space research have demonstrated that microgravity produces significant physiological changes in astronauts. For long-duration missions, the possibility exists that these changes may prevent the achievement of full health and safety and may therefore require countermeasures. Meeting this goal depends on a strong biomedical foundation. Although much research is conducted with humans, some of the most critical work involves a necessary in-depth look into complex problem areas requiring invasive procedures using animals. Much of this research cannot be performed in humans within the bounds of accepted medical practice. A large portion of knowledge and experience in flying animals and applying the data to astronaut health has been obtained through the Spacelab experience and can be applied to a space station situation (expanded to accommodate necessary standardization and flexibility). The objectives of this paper are to (a) discuss the value and potential of animal research in answering critical questions to enable astronaut health for advanced missions, (b) discuss how previous Spacelab operational experience in animal studies can be applied to facilitate transition into a space station era, and (c) review capabilities of biological facilities projected for Space Station Freedom.

Garshnek, V.↗

Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm{sup 2} and the total size of the detector head is 47.8 × 46.3 mm{sup 2}. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve high-resolution scintillator arrays common in small-animal PET with adequate energy resolution and timing resolution over a large detector area. The modular design of the Matrix9 detector allows it to be used as a building block for simple, low channel-count, yet high performance, small animal PET or PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗