Electrocardiogram preprocessing unit.
Analog circuit for presenting fixed pulse output corresponding to each cardiac cycle of given electrocardiogram and highly unresponsive to noise interference
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Analog circuit for presenting fixed pulse output corresponding to each cardiac cycle of given electrocardiogram and highly unresponsive to noise interference
Encoding and decoding techniques using integrated circuits and applicable to binary digitizing of electrical analog information
Key issues are discussed that must be overcome in order to apply commercial semiconductor technologies in space, emphasizing ways to test and qualify devices so they meet radiation hardness requirements.
Device, which converts directly from analog signal to its radix (-2) representation, is based on successive approximation approach.
Proposed integrated-circuit network of many identical units convert analog outputs of imaging arrays of x-ray or infrared detectors to digital outputs. Converter located near imaging detectors, within cryogenic detector package. Because converter output digital, lends itself well to multiplexing and to postprocessing for correction of gain and offset errors peculiar to each picture element and its sampling and conversion circuits. Analog-to-digital image processor is massively parallel system for processing data from array of photodetectors. System built as compact integrated circuit located near local plane. Buffer amplifier for each picture element has different offset.
Perform analog-to-digital conversion on input signal with staircase circuit having 10% resolution, convert digital result to analog voltage, subtract it from original input signal; read out feedback signals as decimal digit representation during one clock phase and servo-error difference between input and feedback as analog portion during following clock phase.
Faraday-rotation data from the linearly polarized 137-MHz beacons of the ATS-1, SIRIO, and Kiku-2 geosynchronous satellites are used to determine the ionospheric corrections to the range and Doppler data for interplanetary spacecraft navigation. The JPL operates the Deep Space Network of tracking stations for NASA; these stations monitor Faraday rotation with dual orthogonal, linearly polarized antennas, Teledyne polarization tracking receivers, analog-to-digital converter/scanners, and other support equipment. Computer software examines the Faraday data, resolves the pi ambiguities, constructs a continuous Faraday-rotation profile and converts the profile to columnar zenith total electron content at the ionospheric reference point; a second program computes the line-of-sight ionospheric correction for each pass of the spacecraft over each tracking complex. Line-of-sight ionospheric electron content using mapped Faraday-rotation data is compared with that using dispersive Doppler data from the Voyager spacecraft; a difference of about 0.4 meters, or 5 x 10 to the 16th electrons/sq m is obtained. The technique of determining the electron content of interplanetary plasma by subtraction of the ionospheric contribution is demonstrated on the plasma torus surrounding the orbit of Io.
With the availability of Magnetic Resonance Imaging (MRI) technology in the medical field and the development of powerful graphics engines in the computer world the possibility now exists for the simulation of surgery using data obtained from an actual patient. This paper describes a surgical simulation system which will allow a physician or a medical student to practice surgery on a patient without ever entering an operating room. This could substantially lower the cost of medial training by providing an alternative to the use of cadavers. This project involves the use of volume data acquired by MRI which are converted to polygonal form using a corrected marching cubes algorithm. The data are then colored and a simulation of surface response based on springy structures is performed in real time. Control for the system is obtained through the use of an attached analog-to-digital unit. A remote electronic device is described which simulates an imaginary tool having features in common with both arthroscope and laparoscope.
Typically an analog signal from a space system is sampled, quantized by Analog-to-Digital (A/D) conversion, merged into a bit stream, communicated to a ground station, received by the ground station, and processed by the ground station to extract useful information for dissemination to the users. The cost of each of these steps is reduced as the number of quantization steps is reduced in the A/D converter. The number of quantization steps should be as small as possible without losing the required information content. This report deals specifically with the accuracy of averages as a function of the number of quantized samples used to compute the averages with the noise on the analog signal as a parameter. For example, the success of the Visible Infrared Spin Scan Radiometer (VISSR) Atmospheric Sounder (VAS) Demonstration depends upon temporally averaging multiple samples in an effort to reduce noise to a sufficiently low level such that temperature profile sounding is made possible. A tutorial description of this process is presented.
The design and projected performance of a low-light-level active-pixel-sensor (APS) chip with semi-parallel analog-to-digital (A/D) conversion is presented. The individual elements have been fabricated and tested using MOSIS* 2 micrometer CMOS technology, although the integrated system has not yet been fabricated. The imager consists of a 128 x 128 array of active pixels at a 50 micrometer pitch. Each column of pixels shares a 10-bit A/D converter based on first-order oversampled sigma-delta (Sigma-Delta) modulation. The 10-bit outputs of each converter are multiplexed and read out through a single set of outputs. A semi-parallel architecture is chosen to achieve 30 frames/second operation even at low light levels. The sensor is designed for less than 12 e^- rms noise performance.
Threshold and A/D devices for converting a gray scale image into a binary one were investigated for all-optical and opto-electronic approaches to parallel processing. Integrated optical logic circuits (IOC) and optical parallel logic devices (OPA) were studied as an approach to processing optical binary signals. In the IOC logic scheme, a single row of an optical image is coupled into the IOC substrate at a time through an array of optical fibers. Parallel processing is carried out out, on each image element of these rows, in the IOC substrate and the resulting output exits via a second array of optical fibers. The OPAL system for parallel processing which uses a Fabry-Perot interferometer for image thresholding and analog-to-digital conversion, achieves a higher degree of parallel processing than is possible with IOC.
Conversion system for increasing resolution of analog to digital converters
The system was developed to record from one up to a maximum of sixteen channels of analog data onto magnetic tape. Each analog channel of data can be sampled at rates of 1, 2, 6, 12, or 60 times per minute. The system is divided into three subunits: a digital clock, an incremental magnetic tape recorder, and a sequential converter. The interfacing requirements of these subunits are presented.
Modification of conventional digital counting filter is designed to store all possible combinations of filter coefficients in random access memory. Filter includes analog-to-digital coverter, X shift register, memory, accumulator, and digital-to-analog converter.
The effect of quantization due to the finite wordlength of microprocessors, analog-to-digital, and digital-to-analog converters, on the desired control law for large flexible structures is investigated. Additionally, the practical effect of actuator dynamics on the stability and performance of the control law is addressed. Finally, an active control experiment is reported which takes into account and demonstrates some of the previously discussed practical considerations.
Multiplexable input/output (I/O) system developed as interface between host computer and real-time, fixed-base simulator cockpit. Unit designed to be general-purpose interface and operated through virtually any 8- or 16-bit, transistor/transistor-logic-level, parallel-I/O port with or without handshaking. Accepts byte-coded data in form of data blocks from host computer and routes data to various system I/O modules like discrete outputs, lamp drivers, and seven-segment-display drivers. Formats and routes data from input modules back to host computer. Other modules designed to drive alphanumeric displays and communications interfaces and to serve as analog-to-digital and digital-to-analog converter modules.
A digitized synchronous demodulator is constructed entirely of digital components including timing logic, an accumulator, and means to digitally filter the digital output signal. Indirectly, it accepts, at its input, periodic analog signals which are converted to digital signals by traditional analog-to-digital conversion techniques. Broadly, the input digital signals are summed to one of two registers within an accumulator, based on the phase of the input signal and medicated by timing logic. At the end of a predetermined number of cycles of the inputted periodic signals, the contents of the register that accumulated samples from the negative half cycle is subtracted from the accumulated samples from the positive half cycle. The resulting difference is an accurate measurement of the narrow band amplitude of the periodic input signal during the measurement period. This measurement will not include error sources encountered in prior art synchronous demodulators using analog techniques such as offsets, charge injection errors, temperature drift, switching transients, settling time, analog to digital converter missing code, and linearity errors.
Lightweight, low-power circuit provides noncontact measurement of alternating or direct current of many ampheres in main conductor. Advantages of circuit over other nulling Hall-effect current-measuring circuits is stability and accuracy increased by putting both analog-to-digital and digital-to-analog converters in nulling feedback loop. Converters and rest of circuit designed for operation at sampling rate of 100 kHz, but rate changed to alter time or frequency response of circuit.