Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-E-T-27: A Dosimetric Evaluation of Boney Anatomy Versus Fiducial Marker Alignment for the Treatment of Prostate Cancer Using Scanned Beam Proton Therapy

Purpose: In prostate proton radiotherapy, three fiducial markers are used for patient daily alignment. However fiducial alignment can change beamline heterogeneity in proton therapy. The purpose of this study is to determine the difference in fiducial and boney anatomy alignment for patient treatment. Methods and materials: Prostate cancer patients who received proton treatment were included in this study. 3 fiducial markers were implanted before the initial CT. All the patients were re-CT’d every 2 weeks to check the fiducial marker position reproducibility as well as dosimetric consistence of target coverage. In geometry study, re-CT were fused to the initial CT base on the boney anatomy and the average fiducial marker displacement was measured the centers of the fiducials. Dosimetrically, the initial plan was recalculated directly to re-CT image set based on the boney alignment and fiducial alignment to determine the difference from daily treatment. Prostate coverage and hotspots were evaluated using the dose to 98% of the CTV (D98) and dose to 2% (D2), respectively. Results: The shift from the initial 6 patient CT image sets resulted in an average change in the fiducial location of 5.70 +/− 3 mm. Dosimetric comparison from a single patient revealed that differences from the planned dose resulted from both boney and fiducial alignment. Planned clinical treatment volume coverage resulted in a D98 of 70.44Gy and D2 of 70.84Gy compared to a D98 of 70.13Gy and D2 70.94Gy for boney alignment and a D98 of 70.08Gy and D2 71.18Gy for fiducial alignment respectively. Conclusion: This study demonstrates that with boney anatomy alignment there is little change to CTV coverage and only slightly worse CTV coverage and hotspot production with fiducial alignment. An increase patient cohort and further investigation is necessary to determine the whether boney alignment can help better control dose heterogeneity.

60 APPLIED LIFE SCIENCES↗

Individual NSLS-II Multipole Magnet Alignment by Laser Trackers

The magnet alignment of the 90 th and final multipole girder assembly was completed January 17 th , 2013. Our procedure of “rough” pre-alignment by laser trackers and final alignment by vibrating wire & “Differential Variable Reluctance Transducers” (DVRT) has been quite successful, achieving magnet to magnet alignment well under the 30 micron specification. The pre-alignment accuracy is verified by the initial scan from the vibrating wire. The alignment residuals can be calculated from the offsets of a best fit line. The results are impressive, especially considering the environment of the Building 902 Annex (which has a large bay door that would open during pre-alignment, without fail), the sloppiness of the magnets’ fiducials, and especially the fact that the girders were pre-aligned to their mechanical centers, but the vibrating wire reports the magnetic centers which may be considerably different. This result hints at the potential feasibility of alignment with laser trackers for replacement magnets of NSLS-II and maybe even all magnets of future accelerators. But, it is difficult to predict the achievable accuracy until the main three error sources (a.k.a. Survey group excuses) are eliminated: measuring environment, bad magnet fiducials, and mechanical/magnetic center differences. The test performed on a large aperture quadrupole on girder assembly C19G4 was designed to answer the following questions with the aforementioned error sources either eliminated or simulated: 1) How accurately can a NSLS-II multipole be realigned after repair or other disturbance given the existing fiducials? 2) How accurately can a replacement NSLS-II multipole be installed in situ if its magnetic center is known relative to good fiducials? 3) If the current NSLS-II spares are never magnetically fiducialized, how well can they be installed using only mechanical data? 4) Could the magnets of a future accelerator (with similar alignment specifications as NSLS-II) be aligned using commercially available metrology instruments? This paper will answer these questions.

36 MATERIALS SCIENCE↗

A Comparison of Soft-Tissue Implanted Markers and Bony Anatomy Alignments for Image-Guided Treatments of Head-and-Neck Cancers

Purpose: To compare the geometric alignments of soft-tissue implanted markers to the traditional bony-based alignments in head-and-neck cancers, on the basis of daily image guidance. Dosimetric impact of the two alignment techniques on target coverage is presented. Methods and Materials: A total of 330 retrospective alignments (5 patients) were performed on daily megavoltage computed tomography (MVCT) image sets using both alignment techniques. Intermarker distances were tracked for all fractions to assess marker interfractional stability. Using a deformable image registration algorithm, target cumulative doses were calculated according to generated shifts on daily MVCT image sets. Target D95 was used as a dosimetric endpoint to evaluate each alignment technique. Results: Intermarker distances overall were stable, with a standard deviation of <1.5 mm for all fractions and no observed temporal trends. Differences in shift magnitudes between both alignment techniques were found to be statistically significant, with a maximum observed difference of 8 mm in a given direction. Evaluation of technique-specific dose coverage based on D95 of target clinical target volume and planning target volume shows small differences (within +-5%) compared with the kilovoltage CT plan. Conclusion: The use of daily MVCT imaging demonstrates that implanted markers in oral tongue and soft-palate cancers are stable localization surrogates. Alignments based on implanted markers generate shifts comparable overall to the traditional bony-based alignment, with no observed systematic difference in magnitude or direction. The cumulative dosimetric impact on target clinical target volume and planning target volume coverage was found to be similar, despite large observed differences in daily alignment shifts between the two techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alignment of Short Reads: A Crucial Step for Application of Next-Generation Sequencing Data in Precision Medicine

Precision medicine or personalized medicine has been proposed as a modernized and promising medical strategy. Genetic variants of patients are the key information for implementation of precision medicine. Next-generation sequencing (NGS) is an emerging technology for deciphering genetic variants. Alignment of raw reads to a reference genome is one of the key steps in NGS data analysis. Many algorithms have been developed for alignment of short read sequences since 2008. Users have to make a decision on which alignment algorithm to use in their studies. Selection of the right alignment algorithm determines not only the alignment algorithm but also the set of suitable parameters to be used by the algorithm. Understanding these algorithms helps in selecting the appropriate alignment algorithm for different applications in precision medicine. Here, we review current available algorithms and their major strategies such as seed-and-extend and q-gram filter. We also discuss the challenges in current alignment algorithms, including alignment in multiple repeated regions, long reads alignment and alignment facilitated with known genetic variants.

59 BASIC BIOLOGICAL SCIENCES↗

Heavy Higgs boson decays in the alignment limit of the 2HDM

The Standard Model (SM)-like couplings of the observed Higgs boson impose strong constraints on the structure of any extended Higgs sector. We consider the theoretical properties and the phenomenological implications of a generic two Higgs doublet model (2HDM). This model constitutes a simple and attractive extension of the SM that is consistent with the observation of the SM-like Higgs boson and precision electroweak observables, while providing a potential new source of CP-violation. In this paper we focus on the so-called Higgs alignment limit of the generic 2HDM, where the neutral scalar field H 1 , with the tree-level couplings of the SM Higgs boson, is a mass eigenstate that is aligned in field space with the direction of the Higgs vacuum expectation value. Tihe properties of the two other heavier neutral Higgs scalars, H 2 and H 3 , in the alignment limit of the 2HDM are also elucidated. It is shown that the couplings of H 2 and H 3 in the alignment limit are tightly constrained and correlated. For example, in the exact alignment limit at tree level, for bosonic final states BR( H 2,3 → W + W - , ZZ, H 1 Z ) = 0 and BR( H ± → W ± H 1 ) = 0, whereas for fermionic final states Γ( H 2 → ff ¯) / Γ( H 3 → ff ¯) ~ M 2 /M 3 (where M α is the mass of H α ). In some cases, the results of the alignment limit differ depending on whether or not alignment is achieved via the decoupling of heavy scalar states. In particular, in the exact alignment limit without decoupling BR( H 2,3 → H 1 H 1 ) = 0, whereas these branching ratios are nonzero in the decoupling regime. Observables that could be used to test the alignment scenario at the LHC are defined and discussed. The couplings of the Higgs bosons away from their exact alignment values are determined to leading order, and some consequences are elucidated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermoreversible Changes in Aligned and Cross-Linked Block Copolymer Melts Studied by Two Color Depolarized Light Scattering

A procedure for creating samples that can be repeatedly cycled between weakly aligned and strongly aligned states is described. Poly(styrene-b-isoprene) block copolymer samples were first shear-aligned and then cross-linked using a high energy electron beam. Samples with more than 1.0 cross-links per chain on average showed almost complete recovery of their initial alignment state even after 20 cycles of heating above the order–disorder transition temperature of the un-cross-linked block copolymer. Samples with 1.1 cross-links per chain, which showed over 90% loss of alignment on heating and almost 100% recovery of alignment on cooling, provided the best example of a reversible aligned-to-unaligned transition. Samples with lower cross-linking densities exhibited irreversible loss of alignment upon heating, while those with higher cross-linking densities exhibited less than 90% loss of alignment upon heating. Alignment was quantified by a technique that we call two color depolarized light scattering (TCDLS), an extension of the traditional depolarized light scattering experiment used to determine the state of order in block copolymers. Qualitative confirmation of our interpretation of TCDLS data was obtained by small-angle X-ray scattering and transmission electron microscopy.

Wilbur, Jeffrey D.↗

SU-F-J-44: Development of a Room Laser Based Real-Time Alignment Monitoring System Using An Array of Photodiodes

Purpose: To develop a real-time alignment monitoring system (RAMS) to compensate for the limitations of the conventional room laser based alignment system, and to verify the feasibility of the RAMS. Methods: The RAMS was composed of a room laser sensing array (RLSA), an analog-todigital converter, and a control PC. In the RLSA, seven photodiodes (each in 1 mm width) are arranged in a pattern that the RAMS provides alignment in 1 mm resolution. It works based on detecting laser light aligned on one of photodiodes. When misaligned, the laser would match with different photodiode(s) giving signal at unexpected location. Thus, how much displaced can be determined. To verify the reproducibility of the system with respect to time as well as repeated set-ups, temporal reproducibility and repeatability test was conducted. The accuracy of the system was tested by obtaining detection signals with varying laser-match positions. Results: The signal of the RAMS was found to be stable with respect to time. The repeatability test resulted in a maximum coefficient of variance of 1.14%, suggesting that the signal of the RAMS was stable over repeated set-ups. In the accuracy test, signals between when the laser was aligned and notaligned with any of sensors could be distinguished by signal intensity. The signals of not-aligned sensors were always below 75% of the signal of the aligned sensor. It was confirmed that the system could detect 1 mm of movement by monitoring the pattern of signals, and could observe the movement of the system in real-time. Conclusion: We developed a room laser based alignment monitoring system. The feasibility test verified that the system is capable of quantitative alignment monitoring in real time. The system is relatively simple, not expensive, and considered to be easily incorporated into conventional room laser systems for real-time alignment monitoring. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignments between Galaxies and the Cosmic Web at z ~ 1–2 in the IllustrisTNG Simulations

Galaxy formation theories predict that galaxy shapes and angular momenta have nonrandom alignments with the cosmic web. This leads to so-called intrinsic alignment between pairs of galaxies, which is important to quantify as a nuisance parameter for weak lensing. We study galaxy–cosmic web alignment in the IllustrisTNG suite of hydrodynamical simulations at redshifts 1 and 2, finding that alignment trends are consistent with previous studies. However, we find that the magnitude of the spin alignment signal is ~2.4× weaker than seen in previous studies of the Horizon-AGN simulation, suggesting that this signal may have a significant dependence on subgrid physics. Based on IllustrisTNG, we then construct mock observational spectroscopic surveys that can probe shape–cosmic web alignment at z ~ 1–2, modeled on the low-z galaxy redshift and IGM tomography surveys on the upcoming Subaru Prime Focus Spectrograph Galaxy Evolution (PFS GE) survey. However, even over box sizes of L = 205 h -1 Mpc, we find that global anisotropies induce a sample variance in the 2D projected alignment signal that depend on the projected direction; this induces significant errors in the observed alignment. We predict a 5.3σ detection of IllustrisTNG's shape alignment signal at z ~ 1 from Subaru PFS GE, although a detection would be challenging at z ~ 2. However, a rough rescaling of the relative alignment signal strengths between the TNG and Horizon-AGN simulations suggests that PFS GE should be able to more easily constrain the latter's stronger signal.

79 ASTRONOMY AND ASTROPHYSICS↗

System and method for 2D workpiece alignment

A carrier capable of holding one or more workpieces is disclosed. The carrier includes movable projections located along the sides of each cell in the carrier. This carrier, in conjunction with a separate alignment apparatus, aligns each workpiece within its respective cell against several alignment pins, using a multiple step alignment process to guarantee proper positioning of the workpiece in the cell. First, the workpieces are moved toward one side of the cell. Once the workpieces have been aligned against this side, the workpieces are then moved toward an adjacent orthogonal side such that the workpieces are aligned to two sides of the cell. Once aligned, the workpiece is held in place by the projections located along each side of each cell. In addition, the alignment pins are also used to align the associated mask, thereby guaranteeing that the mask is properly aligned to the workpiece.

42 ENGINEERING↗

Sequential Dual Alignments Introduce Synergistic Effect on Hexagonal Boron Nitride Platelets for Superior Thermal Performance

Planarly aligning 2D platelets is challenging due to their additional orientational freedom compared to 1D materials. Here, this study reports a sequential dual-alignment approach, employing an extrusion-printing-induced shear force and rotating-magnetic-field-induced force couple for platelet planarly alignment in a yield-stress support bath. It is hypothesized that the partial alignment induced by a directional shear force facilitates subsequent axial rotation of the platelets for planar alignment under an external force couple, resulting in a synergistic alignment effect. This sequential dual-alignment approach achieves better planar alignment of 2D modified hexagonal boron nitride (mhBN). Specifically, the thermal conductivity of the 40 wt% mhBN/epoxy composite is significantly higher (692%) than that of unaligned composites, surpassing the cumulative effect of individual methods (only 133%) with a 5 times more synergistic effect. For 30, 40, and 50 wt% mhBN composites, the thermal conductivity values (5.9, 9.5, and 13.8 W m –1 K –1 ) show considerable improvement compared to the previously reported highest values (5.3, 6.6, and 8.6 W m –1 K –1 ). Additionally, a 3D mhBN/epoxy heat sink is printed and evaluated to demonstrate the feasibility of device fabrication. The approach enables the planar alignment of electrically or thermally conducting 2D fillers during 3D fabrication.

36 MATERIALS SCIENCE↗

The Residual Setup Errors of Different IGRT Alignment Procedures for Head and Neck IMRT and the Resulting Dosimetric Impact

Purpose: To assess residual setup errors during head and neck radiation therapy and the resulting consequences for the delivered dose for various patient alignment procedures. Methods and Materials: Megavoltage cone beam computed tomography (MVCBCT) scans from 11 head and neck patients who underwent intensity modulated radiation therapy were used to assess setup errors. Each MVCBCT scan was registered to its reference planning kVCT, with seven different alignment procedures: automatic alignment and manual registration to 6 separate bony landmarks (sphenoid, left/right maxillary sinuses, mandible, cervical 1 [C1]-C2, and C7-thoracic 1 [T1] vertebrae). Shifts in the different alignments were compared with each other to determine whether there were any statistically significant differences. Then, the dose distribution was recalculated on 3 MVCBCT images per patient for every alignment procedure. The resulting dose-volume histograms for targets and organs at risk (OARs) were compared to those from the planning kVCTs. Results: The registration procedures produced statistically significant global differences in patient alignment and actual dose distribution, calling for a need for standardization of patient positioning. Vertically, the automatic, sphenoid, and maxillary sinuses alignments mainly generated posterior shifts and resulted in mean increases in maximal dose to OARs of >3% of the planned dose. The suggested choice of C1-C2 as a reference landmark appears valid, combining both OAR sparing and target coverage. Assuming this choice, relevant margins to apply around volumes of interest at the time of planning to take into account for the relative mobility of other regions are discussed. Conclusions: Use of different alignment procedures for treating head and neck patients produced variations in patient setup and dose distribution. With concern for standardizing practice, C1-C2 reference alignment with relevant margins around planning volumes seems to be a valid option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Liquid crystallinity driven highly aligned large graphene oxide composites

Graphene is an emerging graphitic carbon materials, consisting of sp{sup 2} hybridized two dimensinal honeycomb structure. It has been widely studied to incorporate graphene with polymer to utilize unique property of graphene and reinforce electrical, mechanical and thermal property of polymer. In composite materials, orientation control of graphene significantly influences the property of composite. Until now, a few method has been developed for orientation control of graphene within polymer matrix. Here, we demonstrate facile fabrication of high aligned large graphene oxide (LGO) composites in polydimethylsiloxane (PDMS) matrix exploiting liquid crystallinity. Liquid crystalline aqueous dispersion of LGO is parallel oriented within flat confinement geometry. Freeze-drying of the aligned LGO dispersion and subsequent infiltration with PDMS produce highly aligned LGO/PDMS composites. Owing to the large shape anisotropy of LGO, liquid crystalline alignment occurred at low concentration of 2 mg/ml in aqueous dispersion, which leads to the 0.2 wt% LGO loaded composites. - Graphical abstract: Liquid crystalline LGO aqueous dispersions are spontaneous parallel aligned between geometric confinement for highly aligned LGO/polymer composite fabrication. - Highlights: • A simple fabrication method for highly aligned LGO/PDMS composites is proposed. • LGO aqueous dispersion shows nematic liquid crystalline phase at 0.8 mg/ml. • In nematic phase, LGO flakes are highly aligned by geometric confinement. • Infiltration of PDMS into freeze-dried LGO allows highly aligned LGO/PDMS composites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding Interfacial Alignment in Solution Coated Conjugated Polymer Thin Films

Domain alignment in conjugated polymer thin films can significantly enhance charge carrier mobility. However, the alignment mechanism during meniscus-guided solution coating remains unclear. Furthermore, interfacial alignment has been rarely studied despite its direct relevance and critical importance to charge transport. In this study, we uncover a significantly higher degree of alignment at the top interface of solution coated thin films, using a donor–acceptor conjugated polymer, poly(diketopyrrolopyrrole-co-thiopheneco- thieno[3,2- b ]thiophene-co-thiophene) (DPP2T-TT), as the model system. At the molecular level, we observe in-plane π–π stacking anisotropy of up to 4.8 near the top interface with the polymer backbone aligned parallel to the coating direction. The bulk of the film is only weakly aligned with the backbone oriented transverse to coating. At the mesoscale, we observe a well-defined fibril-like morphology at the top interface with the fibril long axis pointing toward the coating direction. Significantly smaller fibrils with poor orientational order are found on the bottom interface, weakly aligned orthogonal to the fibrils on the top interface. The high degree of alignment at the top interface leads to a charge transport anisotropy of up to 5.4 compared to an anisotropy close to 1 on the bottom interface. We attribute the formation of distinct interfacial morphology to the skin-layer formation associated with high Peclet number, which promotes crystallization on the top interface while suppressing it in the bulk. As a result, we further infer that the interfacial fibril alignment is driven by the extensional flow on the top interface arisen from increasing solvent evaporation rate closer to the meniscus front.

36 MATERIALS SCIENCE↗

Computational studies of the x-ray scattering properties of laser aligned stilbene

The enhancement of the x-ray scattering signal from partially aligned molecular samples is investigated. The alignment properties of the studied molecular system are modeled based on the method of laser alignment. With the advances in the area of laser alignment of molecules, the application of this sample manipulation technique promises a great potential for x-ray scattering measurements. Preferential alignment of molecules in an otherwise amorphous sample leads to constructive interference and thus increases the scattering intensity. This enhances the structural information encoded in the scattering images and enables improved resolution in studies of reaction dynamics, as in this work is shown for the example of the photo-isomerization of stilbene. We demonstrate that the scattering signal is strongly influenced by the alignment axis. Even the most basic one-dimensional alignment offers significant improvement compared to the structural information provided by a randomly oriented sample. Although the signal is sensitive to the uncertainty in the alignment angle, it offers encouraging results even at realistic alignment uncertainties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alignments of dark matter halos with large-scale tidal fields: mass and redshift dependence

Large-scale tidal fields estimated directly from the distribution of dark matter halos are used to investigate how halo shapes and spin vectors are aligned with the cosmic web. The major, intermediate, and minor axes of halos are aligned with the corresponding tidal axes, and halo spin axes tend to be parallel with the intermediate axes and perpendicular to the major axes of the tidal field. The strengths of these alignments generally increase with halo mass and redshift, but the dependence is only on the peak height, ν≡δ{sub c}/σ(M{sub h},z). The scaling relations of the alignment strengths with the value of ν indicate that the alignment strengths remain roughly constant when the structures within which the halos reside are still in a quasi-linear regime, but decreases as nonlinear evolution becomes more important. We also calculate the alignments in projection so that our results can be compared directly with observations. Finally, we investigate the alignments of tidal tensors on large scales, and use the results to understand alignments of halo pairs separated at various distances. Our results suggest that the coherent structure of the tidal field is the underlying reason for the alignments of halos and galaxies seen in numerical simulations and in observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Halo Intrinsic Alignment: Dependence on Mass, Formation Time, and Environment

In this paper we use high-resolution cosmological simulations to study halo intrinsic alignment and its dependence on mass, formation time, and large-scale environment. In agreement with previous studies using N -body simulations, it is found that massive halos have stronger alignment. For the first time, we find that for a given halo mass older halos have stronger alignment and halos in cluster regions also have stronger alignment than those in filaments. To model these dependencies, we extend the linear alignment model with inclusion of halo bias and find that the halo alignment with its mass and formation time dependence can be explained by halo bias. However, the model cannot account for the environment dependence, as it is found that halo bias is lower in clusters and higher in filaments. Our results suggest that halo bias and environment are independent factors in determining halo alignment. We also study the halo alignment correlation function and find that halos are strongly clustered along their major axes and less clustered along the minor axes. The correlated halo alignment can extend to scales as large as 100 h {sup −1} Mpc, where its feature is mainly driven by the baryon acoustic oscillation effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Satellite alignment. I. Distribution of substructures and their dependence on assembly history from n-body simulations

Observations have shown that the spatial distribution of satellite galaxies is not random, but aligned with the major axes of central galaxies. This alignment is dependent on galaxy properties, such that red satellites are more strongly aligned than blue satellites. Theoretical work conducted to interpret this phenomenon has found that it is due to the non-spherical nature of dark matter halos. However, most studies overpredict the alignment signal under the assumption that the central galaxy shape follows the shape of the host halo. It is also not clear whether the color dependence of alignment is due to an assembly bias or an evolution effect. In this paper we study these problems using a cosmological N-body simulation. Subhalos are used to trace the positions of satellite galaxies. It is found that the shapes of dark matter halos are mis-aligned at different radii. If the central galaxy shares the same shape as the inner host halo, then the alignment effect is weaker and agrees with observational data. However, it predicts almost no dependence of alignment on the color of satellite galaxies, though the late accreted subhalos show stronger alignment with the outer layer of the host halo than their early accreted counterparts. We find that this is due to the limitation of pure N-body simulations where satellite galaxies without associated subhalos ('orphan galaxies') are not resolved. These orphan (mostly red) satellites often reside in the inner region of host halos and should follow the shape of the host halo in the inner region.

79 ASTRONOMY AND ASTROPHYSICS↗

MONACO: accurate biological network alignment through optimal neighborhood matching between focal nodes

Motivation: Alignment of protein–protein interaction networks can be used for the unsupervised prediction of functional modules, such as protein complexes and signaling pathways, that are conserved across different species. To date, various algorithms have been proposed for biological network alignment, many of which attempt to incorporate topological similarity between the networks into the alignment process with the goal of constructing accurate and biologically meaningful alignments. Especially, random walk models have been shown to be effective for quantifying the global topological relatedness between nodes that belong to different networks by diffusing node-level similarity along the interaction edges. However, these schemes are not ideal for capturing the local topological similarity between nodes. Results: Here, we propose MONACO, a novel and versatile network alignment algorithm that finds highly accurate pairwise and multiple network alignments through the iterative optimal matching of ‘local’ neighborhoods around focal nodes. Extensive performance assessment based on real networks as well as synthetic networks, for which the ground truth is known, demonstrates that MONACO clearly and consistently outperforms all other state-of-the-art network alignment algorithms that we have tested, in terms of accuracy, coherence and topological quality of the aligned network regions. Furthermore, despite the sharply enhanced alignment accuracy, MONACO remains computationally efficient and it scales well with increasing size and number of networks.

97 MATHEMATICS AND COMPUTING↗