Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABSORB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Insights on the Effects of Magnetic Forces on the Efficiency of Vibration Energy Harvesting Absorbers in Controlling Dynamical Systems

This study investigates the effects of magnetic constraints on a piezoelectric energy harvesting absorber while simultaneously controlling a primary structure and harnessing energy. An accurate forcing representation of the magnetic force is investigated and developed. A reduced-order model is derived using the Euler–Lagrange principle, and the impact of the magnetic force is evaluated on the absorber’s static position and coupled natural frequency of the energy harvesting absorber and the coupled primary absorber system. The results show that attractive magnet configurations cannot improve the system substantially before pull-in occurs. A rigorous eigenvalue problem analysis is performed on the absorber’s substrate thickness and tip mass to effectively design an energy harvesting absorber for multiple initial gap sizes for the repulsive configurations. Then, the effects of the forcing amplitude on the primary structure absorber are studied and characterized by determining an effective design of the system for a simultaneous reduction in the primary structure’s motion and improvement in the harvester’s efficiency.

42 ENGINEERING↗

Determination of decay coefficients for combustors with acoustic absorbers

An analytical technique for the calculation of linear decay coefficients in combustors with acoustic absorbers is presented. Tuned circumferential slot acoustic absorbers were designed for the first three transverse modes of oscillation, and decay coefficients for these absorbers were found as a function of backing distance for seven different chamber configurations. The effectiveness of the absorbers for off-design values of the combustion response and acoustic mode is also investigated. Results indicate that for tuned absorbers the decay coefficient increases approximately as the cube of the backing distance. For most off-design situations the absorber still provides a damping effect. However, if an absorber designed for some higher mode of oscillation is used to damp lower mode oscillations, a driving effect is frequently found.

Mitchell, C. E.↗

Characterization of metal oxide absorbents for regenerative carbon dioxide and water vapor removal for advanced portable life support systems

Characterization of the performance of a silver-oxide-based absorbent in terms of its ability to remove both gaseous CO2 and water vapor in an astronaut portable life support systems (PLSS) is discussed. Attention is focused on regeneration of the absorbent from the carbonite state of the oxide state, preconditioning of the absorbent using a humidified gas stream, and absorption breakthrough testing. Based on the results of bench-scale experiments, a test plan is carried out to further characterize the silver-oxide-based absorbent on a larger scale; it calls for examination of the absorbent in both an adiabatic packed bed and a near-isothermal cooled bed configuration. It is demonstrated that the tested absorbent can be utilized in a way that removes substantial amounts of CO2 and water vapor during an 8-hour extravehicular activity mission, and that applying the absorbent to PLSS applications can simplify the ventilation loop.

Kast, Timothy P.↗

The X-ray and ultraviolet absorbing outflow in 3C 351

3C 351 (z = 0.371), and X-ray-'quiet' quasar, is one of the few quasars showing signs of a 'warm absorber' in its X-ray spectrum; i.e., partially ionized absorbing material in the line of sight whose opacity depends on its ionization structure. The main feature in the X-ray spectrum is a K-edge due to O VII or O VIII. 3C 351 also shows unusually strong, blueshifted, associated, absorption lines in the ultraviolet (Bahcall et al. 1993) including O VI (lambda lambda 1031, 1037). This high ionization state strongly suggests an identification with the X-ray absorber and a site within the active nucleus. In this paper we demonstrate that the X-ray and UV absorption is due to the same material. This is the first confirmed UV/X-ray absorber. Physical conditions of the absorber are determined through the combination of constraints derived from both the X-ray and UV analysis. This highly ionized, outflowing, low-density, high-column density absorber situated outside the broad emission line region (BELR) is a previously unknown component of nuclear material. We rule out the identification of the absorber with a BELR cloud as the physical conditions in the two regions are inconsistent with one another. The effect of the X-ray quietness and IR upturn in the 3C 351 continuum on the BELR is also investigated. The strengths of the high-ionization lines of C IV lambda-1549 and O VI lambda-1034 with respect to Lyman-alpha are systematically lower (up to a factor of 10) in the material ionized by the 3C 351 continuum as compared to those produced by the 'standard' quasar continuum, the strongest effect being on the strength of O VI lambda-1034. We find that for a 3C 351-like continuum, C III) lambda-1909 ceases to be a density indicator.

Mathur, Smita↗

Application of PML Absorbing Boundary Conditions to the Benchmark Problems of Computational Aeroacoustics

Accurate numerical non-reflecting boundary conditions are important in all the proposed benchmark problems of the Second Workshop. Recently, a new absorbing boundary condition has been developed using Perfectly Matched Layer (PML) equations for the Euler equations. In this approach, a region with a width of a few grid points is introduced adjacent to the non-reflecting boundaries. In the added region, Perfectly Matched Layer equations are constructed and applied so that the out-going waves are absorbed inside the layer with little reflection to the interior domain. It will be demonstrated in the present paper that the proposed absorbing boundary condition is quite general and versatile, applicable to radiation boundaries as well as inflow and outflow boundaries. It is also easy to implement. The emphasis of the paper will be on the application of the PML absorbing boundary condition to problems in Categories 1, 2, and 3. In Category 1, solutions of problems 1 and 2 are presented. Both problems are solved using a multi-domain polar grid system. Perfectly Matched Layer equations for a circular boundary are constructed and their effectiveness assessed. In Category 2, solutions of problem 2 are presented. Here, in addition to the radiation boundary conditions at the far field in the axisymmetric coordinate system, the inflow boundary condition at the duct inlet is also dealt with using the proposed Perfectly Match Layer equations. At the inlet, a PML domain is introduced in which the incident duct mode is simulated while the waves reflected from the open end of the duct are absorbed at the same time. In Category 3, solutions of all three problems are presented. Again, the PML absorbing boundary condition is used at the inflow boundary so that the incoming vorticity wave is simulated while the outgoing acoustic waves are absorbed with very little numerical reflection. All the problems are solved using central difference schemes for spatial discretizations and the optimized Low-Dissipation and Low-Dispersion Runge-Kutta scheme for the time integration. Issues of numerical accuracy and efficiency are also addressed.

Hu, Fang Q.↗

Discovery of Associated Absorption Lines in an X-Ray Warm Absorber: Hubble Space Telescope Observations of PG 1114+445

The unified picture of X-ray/UV absorbers offers a unique opportunity to probe the nuclear environment of active galactic nuclei. To test the unified absorber scenario and to understand the physical properties of the absorber, we obtained the first UV spectrum of PG 1114+445 using the Hubble Space Telescope (HST) Faint Object Spectrograph. PG 1114+445 is known to have an X-ray ionized ('warm') absorber,so that UV absorption is predicted. The HST spectrum clearly shows strong UV absorption lines due to Lyalpha, C iv, and N v, blueshifted by approximately 530 km s(exp -1) with respect to the quasar redshift. Since both X-ray and UV absorbers are rare in radio-quiet quasars, these observations argue strongly that the X-ray and UV absorbers are closely physically related. perhaps identical. We place constraints on the parameters of the absorber and conclude that the mass outflow rate is comparable to the accretion rate in PG 1114+445.

Mathur, Smita↗

Discovery of Associated Absorption Lines in an X-Ray Warm Absorber: Hubble Space Telescope Faint Object Spectrograph Observations of MR 2251-178

The presence of a 'warm absorber' was first suggested to explain spectral variability in an X-ray spectrum of the radio-quiet quasi-stellar object (QSO) MR 2251-178. A unified picture, in which X-ray warm absorbers and 'intrinsic' UV absorbers are the same, offers the opportunity to probe the nuclear environment of active galactic nuclei. To test this scenario and understand the physical properties of the absorber, we obtained a UV spectrum of MR 2251-178 with the Faint Object Spectrograph on board the Hubble Space Telescope (HST). The HST spectrum clearly shows absorption due to Lyalpha, N v, and C IV, blueshifted by 300 km s(exp -1) from the emission redshift of the QSO. The rarity of both X-ray and UV absorbers in radio-quiet QSOs suggests these absorbers are physically related, if not identical. Assuming the unified scenario, we place constraints on the physical parameters of the absorber and conclude the mass outflow rate is essentially the same as the accretion rate in MR 2251-178.

Monier, Eric M.↗

Unification of X-ray Winds in Seyfert Galaxies: From Ultra-fast Outflows to Warm Absorbers

The existence of ionized X-ray absorbing layers of gas along the line of sight to the nuclei of Seyfert galaxies is a well established observational fact. This material is systematically outflowing and shows a large range in parameters. However, its actual nature and dynamics are still not clear. In order to gain insights into these important issues we performed a literature search for papers reporting the parameters of the soft X-ray warm absorbers (WAs) in 35 type 1 Seyferts and compared their properties to those of the ultra-fast outflows (UFOs) detected in the same sample. The fraction of sources with WAs is >60 per cent, consistent with previous studies. The fraction of sources with UFOs is >34 per cent, >67 per cent of which also show WAs. The large dynamic range obtained when considering all the absorbers together, spanning several orders of magnitude in ionization, column, velocity and distance allows us, for the first time, to investigate general relations among them. In particular, we find significant correlations indicating that the closer the absorber is to the central black hole, the higher the ionization, column, outflow velocity and consequently the mechanical power. In all the cases, the absorbers continuously populate the whole parameter space, with the WAs and the UFOs lying always at the two ends of the distribution. These evidence strongly suggest that these absorbers, often considered of different types, could actually represent parts of a single large-scale stratified outflow observed at different locations from the black hole. The UFOs are likely launched from the inner accretion disc and the WAs at larger distances, such as the outer disc and/or torus. We argue that the observed parameters and correlations are, to date, consistent with both radiation pressure through Compton scattering and magnetohydrodynamic processes contributing to the outflow acceleration, the latter playing a major role. Most of the absorbers, especially the UFOs, show a sufficiently high mechanical power (at least approx 0.5 per cent of the bolometric luminosity) to provide a significant contribution to active galactic nuclei (AGN) feedback and thus to the evolution of the host galaxy. In this regard, we find possible evidence for the interaction of the AGN wind with the surrounding environment on large scales.

Unification↗

Composite energy-absorbing assembly

An energy-absorbing assembly includes a housing and a plurality of discrete energy-absorbing elements. The housing includes a first wall and a second wall. The first wall and the second wall are spaced apart from one another to at least partially define an interior compartment. Each element of the plurality of energy-absorbing elements includes a polymer and a plurality of reinforcing fibers. The plurality of energy-absorbing elements is at least partially disposed within the interior compartment and fixed to the housing. Each energy-absorbing element of the plurality of energy-absorbing elements includes an elongated hollow structure extending between a first end and a second end. Each elongated hollow structure defines a longitudinal axis extending nonparallel to at least one of the first wall and the second wall. In various alternative aspects, each energy-absorbing element may include a transverse wall.

Rodgers, William R.↗

Oxidizer Testing on Alternative Absorbents for Los Alamos National Laboratory - 18656

In the summer of 2016, during glovebox operations in TA-55, cheesecloth, a cellulosic material, was used to clean up a small spill of 9.8 molar nitric acid (oxidizer). Because cellulosic materials and oxidizers are incompatible, this prompted a chemical compatibility evaluation of the waste in TA-55 to determine if this waste was Resource Conservation and Recovery Act (RCRA) ignitable waste (D001) or RCRA reactive waste (D003). After testing and consulting with the Carlsbad Field Office in Carlsbad (CBFO), Los Alamos National Laboratory (LANL) NPI-7 decided to look for alternative absorbents to use in the gloveboxes that would not create an incompatibility issue with an oxidizer. While small spills are infrequent, they do happen and LANL wanted to be proactive and search for a material that would be compatible with an oxidizer. In December 2016, LANL NPI-7 requested LANL-Carlsbad's (LANL-CO) Difficult Waste Team to perform compatibility testing on potential alternative wipes for disposal at the Waste Isolation Pilot Plant (WIPP). The purpose for testing was to meet the Operational Experience Level 3 (OE-3) requirements that states 'any proposed use of organic absorbents or engineered absorbents in combination with potentially oxidizing TRU waste, wet or dry, should be evaluated and approved by the National TRU Program, Carlsbad Field Office' [1]. LANL NPI-7 requested LANL-CO to perform these tests because they were the group that performed all of the oxidizer testing for CBFO for the Basis of Knowledge (BoK) [2]. LANL NPI-7 chose nine fabrics and KMI Zeolite to be tested. The testing in Carlsbad took approximately 2 months to prepare the procedures, test plans and for the procurement of items. The burn rate testing was done in accordance with the requirements discussed in the BoK and approved by the LANL-CO Difficult Waste Team. Each absorbent was tested for 1) capacity limiting tests, 2) verifying the non-oxidizer threshold concentration of the oxidizer and 3) establishing the non-oxidizer concentration based on the experimental results. The effect of rinsing cheesecloth samples that have absorbed an oxidizer was also tested [3]. The burn rate testing provided three potential alternative absorbents (Spilfyter Hazmat Sorbent SM Pads Premium, Kimtech Pure W4 Wipers and Polybenzimidazole (PBI) Staple fiber) that produced a non-oxidizer result as defined by the BoK. Two wipes Spilfyter Hazmat Sorbent SM Pads Premium and Kimtech Pure W4 Wipers were able to absorb the highest concentration of potassium nitrite and still produce a non-oxidizer. TA-55 has used Spilfyter Hazmat Sorbent SM Pads Premium for a number of years in several of the processes and has ordered Kimtech Pure W4 Wipers for use in the facility. PBI fabric passed at 25 wt. % solution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Realizing thin electromagnetic absorbers for wide incidence angles from commercially available planar circuit materials

In this study, recent work on engineering R-card surface resistivity with printed metallic patterns is extended to the design of thin electromagnetic absorbers. Thin electromagnetic absorbers for wide incidence angles and both polarizations have recently been computationally verified by Luukkonen et al.. These absorbers are analytically modeled high-impedance surfaces with capacitive arrays of square patches implemented with relatively high dielectric constant and high loss substrate. However, the advantages provided by the accurate analytical model are largely negated by the need to obtain high dielectric constant material with accurately engineered loss. Fig. I(c) illustrates full-wave computational results for an absorber without vias engineered as proposed by Luukkonen et al.. Unique values for the dielectric loss are required for different center frequencies. Parameters for the capacitive grid are D=5.0 mm and w=O.l mm for a center frequency of 3.36 GHz. The relative permittivity and thickness is 9.20(1-j0.234) and 1=3.048 mm. Consider a center frequency of5.81 GHz and again 1=3.048 mm, the required parameters for the capacitive grid are D=2.0 mm and w=0.2 mm where the required relative permittivity is now 9.20(1-j0.371) Admittedly, engineered dielectrics are themselves a historically interesting and fruitful research area which benefits today from advances in monolithic fabrication using direct-write of dielectrics with nanometer scale inclusions. However, our objective in the present study is to realize the advantages of the absorber proposed by Luukkonen et al. without resort to engineered lossy dielectrics. Specifically we are restricted to commercially available planer circuit materials without use of in-house direct-write technology or materials engineering capability. The materials considered here are TMM 10 laminate with (35 {mu}lm copper cladding with a complex permittivity 9.20-j0.0022) and Ohmegaply resistor conductor material (maximum 250 {Omega}/sq.). A thin electromagnetic absorber for incidence angles greater than 30deg. but less than 60deg. and both polarizations is computationally demonstrated. This absorber utilizes high-permittivity, low-loss microwave substrate in conjunction with an engineered lossy sheet impedance. The lossy sheet impedance is easily engineered with simple analytical approximations and can be manufactured from commercially available laminate materials on microwave substrate.

66↗

RANS Simulation of the Heave Response of a Two-Body Floating Point Wave Absorber: Preprint

A preliminary study on a two-body floating wave absorbers is presented in this paper. A Reynolds-Averaged Navier-Stokes computational method is applied for analyzing the hydrodynamic heave response of the absorber in operational wave conditions. The two-body floating wave absorber contains a float section and a submerged reaction section. For validation purposes, our model is first assumed to belocked. The two sections are forced to move together with each other. The locked single body model is used in a heave decay test, where the RANS result is validated with the experimental measurement. For the two-body floating point absorber simulation, the two sections are connected through a mass-spring-damper system, which is applied to simulate the power take-off mechanism under design waveconditions. Overall, the details of the flow around the absorber and its nonlinear interaction with waves are investigated, and the power absorption efficiency of the two-body floating wave absorber in waves with a constant value spring-damper system is examined.

17 WIND ENERGY↗

Burnable absorbers in nuclear reactors – A review

Burnable absorbers can benefit nuclear reactors of virtually any design by providing reactivity control for extended fuel cycles, tritium production, burning of long-lived radionuclides, and reactor safety. When selecting the ideal burnable absorber type and its design, one must consider the resulting impact on the reactor’s fuel cycle design and cost, reactivity, thermal hydraulics, manufacturing, and radiation response. These selection criteria, as well as neutronic and thermophysical material property requirements, may be vastly different depending on whether the burnable absorber is intended for use in a commercial water-cooled reactor, a research reactor, or a next-generation advanced reactor system. A recent integration, synthesis, description of past and present technologies, and identification of existing gaps and areas of future research is lacking on these important topics. Here, this paper includes a fundamental description of the use of burnable absorbers and their impacts on reactivity, absorber depletion, self-shielding, basic thermophysical properties, and the use of burnable absorbers in next-generation nuclear applications..

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Semiconductor-dielectric-metal solar absorbers with high spectral selectivity

An ideal solar thermal absorber has a sharp transition between high and low absorptance at the wavelength where the blackbody emissive power begins to exceed the solar irradiance. However, most real selective absorbers have a fairly broad transition, leading to both solar absorption and thermal emission losses. Here, we model, fabricate, and characterize a highly selective semiconductor-dielectric-metal (Ga0.46In0.54As - MgF2 - Ag) solar absorber with an extremely sharp transition from high to low absorptance. The thin semiconductor serves as a selective filter, absorbing photons with wavelengths shorter than the bandgap and transmitting those with longer wavelengths. The highly reflective dielectric-metal rear mirror allows the structure to have very low emittance for longer wavelengths. These characteristics provide the absorber with a measured solar absorptance >91% below the bandgap wavelength and infrared emittance <5% at 100 degrees C above the bandgap wavelength. This transition wavelength can be tuned by modifying the semiconductor composition, and modeling indicates that the absorber's optical properties should be stable at high temperatures, making the structure a good candidate for unconcentrated to highly concentrated solar thermal energy conversion.

14 SOLAR ENERGY↗

SU-E-T-204: Comparison of Absorbed-Dose to Water in High-Energy Photon Beams Based On Addendum AAPM TG-51, IAEA TRS-398, and JSMP 12

Purpose: Several clinical reference dosimetry protocols for absorbed-dose to water have recently been published: The American Association of Physicists in Medicine (AAPM) published an Addendum to the AAPM’s TG-51 (Addendum TG-51) in April 2014, and the Japan Society of Medical Physics (JSMP) published the Japan Society of Medical Physics 12 (JSMP12), a clinical reference dosimetry protocol, in September 2012. This investigation compared and evaluated the absorbed-dose to water of high-energy photon beams according to Addendum TG-51, International Atomic Energy Agency Technical Report Series No. 398 (TRS-398), and JSMP12. Methods: Differences in the respective beam quality conversion factors with Addendum TG-51, TRS-398, and JSMP12 were analyzed and the absorbed-dose to water using 6- and 10-MV photon beams was measured according to the protocols recommended in Addendum TG-51, TRS-398, and JSMP12. The measurements were conducted using two Farmer-type ionization chambers, Exradin A12 and PTW 30013. Results: The beam quality conversion factors for both the 6- and 10-MV photon beams with Addendum TG-51 were within 0.6%, in agreement with the beam quality conversion factors with TRS-398 and JSMP12. The Exradin A12 provided an absorbed-dose to water ratio from 1.003 to 1.006 with TRS-398 / Addendum TG-51 and from 1.004 to 1.005 with JSMP 12 / Addendum TG-51, whereas the PTW 30013 provided a ratio of 1.001 with TRS-398 / Addendum TG-51 and a range from 0.997 to 0.999 with JSMP 12 / Addendum TG-51. Conclusion: Despite differences in the beam quality conversion factor, no major differences were seen in the absorbed-dose to water with Addendum TG-51, TRS-398, and JSMP12. However, Addendum TG-51 provides the most recent data for beam quality conversion factors based on Monte Carlo simulation and greater detail for the measurement protocol. Therefore, the absorbed-dose to water measured with Addendum TG-51 is an estimate with less uncertainty.

60 APPLIED LIFE SCIENCES↗

Accuracy of a dose-area product compared to an absorbed dose to water at a point in a 2 cm diameter field

Purpose: Graphite calorimeters with a core diameter larger than the beam can be used to establish dosimetric references in small fields. The dose-area product (DAP) measured can theoretically be linked to an absorbed dose at a point by the determination of a profile correction. This study aims at comparing the DAP-based protocol to the usual absorbed dose at a point protocol in a 2 cm diameter field for which both references exist. Methods: Two calorimeters were used, respectively, with a sensitive volume of 0.6 cm (for the absorbed dose at a point measurement) and 3 cm diameter (for the DAP measurement). Profile correction was calculated from a 2D dose mapping using three detectors: a PinPoint chamber, a synthetic diamond, and EBT3 films. A specific protocol to read EBT3 films was implemented and the dose-rate and energy dependences were studied to assure a precise measurement, especially in the penumbra and out-of-field regions. Results: EBT3 films were found independent on dose rates over the range studied but showed a strong under-response (18%) at low energies. Depending on the dosimeter used for calculating the profile correction, a deviation of 0.8% (PinPoint chamber), 0.9% (diamond), or 1.9% (EBT3 films) was observed between the calibration coefficient derived from DAP measurements and the one directly established in terms of absorbed dose to water at a point. Conclusions: The DAP method can currently be linked to the classical dosimetric reference system based in an absorbed dose at a point only with a confidence interval of 95% (k = 2). None of the detectors studied can be used to determine an absorbed dose to water at a point from a DAP measurement with an uncertainty smaller than 1.2%.

60 APPLIED LIFE SCIENCES↗

A microchannel shell-and-tube absorber for ammonia-water absorption

A shell-and-tube absorber with microscale geometric features that yields significant volumetric heat duties is investigated. A vertically-oriented baffled shell-and-tube heat exchanger with a tightly packed tube bundle is designed to serve as the absorber for a 10.5 kW nominal cooling capacity absorption chiller. The heat and mass transfer in this absorber is investigated experimentally at operating conditions spanning a wide range of working fluid and coupling fluid flow rates and ambient temperatures. An experimental facility is fabricated to closely simulate the operating conditions in an absorption refrigeration system. Absorption heat duties in the range of 5-15 kW are measured. In addition to operating the absorber in the baseline co-current flow configuration with premixed inlet, fluid ports are provided to enable operation in counter-current flow, where the dilute solution enters from the top and vapor enters from the bottom. The performance of these two flow configurations is compared. A preliminary heat and mass transfer model is developed to quantify the local temperatures, concentrations, and mass flow rates of the solution and vapor streams along the length of the absorber. The model predictions for total heat duty agree with the experimental results within 10% for almost all the data points, with an AAD of ~3.4%. Finally, the results of this study, along with the modeling framework, can guide further development of highly compact and efficient absorbers absorption systems.

42 ENGINEERING↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗