Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “47 OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

General guide concepts for compact, high-brilliance neutron moderators

The trend in neutron sciences is toward integrating compact, high-brightness moderators into new or upgraded facilities. Transporting neutrons from the source to the sample position with a phase-space distribution tailored to specific requirements is crucial to leverage high source brilliance. Here we have investigated four guide concepts using Monte Carlo ray tracing simulations: Montel beamline with nested Kirkpatrick–Baez mirrors, curved-tapered beamline with a bender and straight sections, straight-elliptical beamline, and curved-elliptical beamline. The straight-elliptical (curved-elliptical) beamline features two half-ellipse guides connected by a straight (non-straight) guide section. The neutron transport efficiency and phase space homogeneity have been quantitatively compared. Our results show that the straight-elliptical beamline performs best because of few neutron bounces on the guide surface with small reflection angles, minimizing flux loss. The Montel beamline provides the best spatial confinement of neutrons within the desired region; however, there is a high thermal-neutron loss due to large reflection angles. The curved-tapered beamline suffers from significant flux loss due to high bounces, and it shows a non-uniform angular distribution related to broad ranges of bounces and reflection angles. The non-straight guide section of the curved-elliptical beamline increases the phase space inhomogeneity, leading to a spatially non-uniform beam profile. The results apply to general neutron instruments that require transporting thermal and cold neutrons from a compact, high-brilliance moderator to the sample location with a moderate phase-space volume.

47 OTHER INSTRUMENTATION↗

SRNL Coulometer for LANL - SRNL-Testing 2020 (Final Report)

SRNL fabricated two coulometers that have been delivered to LANL. All testing for electrical components is performed by R&D engineering and the results are attached to this report. Instrument testing for the first instrument was completed on August 2018 and installation at LANL was completed February 2019. This report addresses testing performed at FH Analytical Laboratory for the second instrument that arrived at LANL on June 5th, 2020. The testing is performed using Plutonium working standards. The instrument was kept in a radiologically clean area. The component calibration of the second LANL coulometer was completed in SRNL Building 723-A.

47 OTHER INSTRUMENTATION↗

Isokinetic Inlet Aboard Aircraft (INLETISOK-AIR) Instrument Handbook

Isokinetic Inlet aboard the aircraft designed by Brechtel (Hayward, California) and modified by Pacific Northwest National Laboratory (PNNL). Additional information can be found on the manufacturer’s website. An earlier model was used on the Gulfstream-159 (G-1) aircraft operated by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF) until 2019. A newer version of this instrument will be deployed on the replacement Challenger 850 aircraft. Modifications to the inlet involve making the software compatible with the aircraft’s data acquisition system.

47 OTHER INSTRUMENTATION↗

An overview of polarized neutron instruments and techniques in Asia Pacific

Polarized neutron scattering is an indispensable tool for exploring a vast range of scientific phenomena. With its dynamic scientific community and significant governmental support as well as the rapid economic growth, the Asia–Pacific region has become a key player in the worldwide neutron scattering arena. From traditional research reactors to cutting-edge spallation neutron sources, this region is home to a myriad of advanced instruments offering a wide range of polarized neutron capabilities. This review aims to provide a comprehensive overview of the development and current status of polarized neutron instruments and techniques in the Asia–Pacific region, emphasizing the important role of the Asia–Pacific region in shaping the landscape of global polarized neutron scattering development.

47 OTHER INSTRUMENTATION↗

Calibration of the Falcon Solid-state Energetic Electron Detector (SEED)

The Falcon Solid-state Energetic Electron Detector (FalconSEED) is an energetic charged particle sensor that has been developed and tested at the United States Air Force Academy in an effort to monitor electron flux across the energy range of 14 to 145 keV in geosynchronous orbit. This sensor has been developed to complement ongoing efforts by the Air Force Research Laboratory to advance a comprehensive space environment sensor suite, Compact Environmental Anomaly Sensor (CEASE3), for anomaly resolution. In addition, FalconSEED is intended to demonstrate the ability to operate a radiation sensor based on predominantly commercial off the shelf components in the geosynchronous environment. This paper describes the design, development, and calibration of FalconSEED. The electron energy spectrum of interest for the FalconSEED sensor is 14 to 145 keV, and is intended to supplement data acquired from the CEASE3 instrument for anomaly resolution. The calibrations at the Space Atmospheric Research Center at the United States Air Force Academy and Kirtland Air Force Base were used to first establish the conversion between histogram bin number and deposited energy in the sensor, and second have been used to determine the geometric factor as a function of energy. The FalconSEED will be integrated as a science payload on the Space Test Program Satellite-6 which also includes the first flight of the CEASE3 instrument and is scheduled to launch in 2021.

47 OTHER INSTRUMENTATION↗

Predicting ptychography probe positions using single-shot phase retrieval neural network

Ptychography is a powerful imaging technique that is used in a variety of fields, including materials science, biology, and nanotechnology. However, the accuracy of the reconstructed ptychography image is highly dependent on the accuracy of the recorded probe positions which often contain errors. These errors are typically corrected jointly with phase retrieval through numerical optimization approaches. When the error accumulates along the scan path or when the error magnitude is large, these approaches may not converge with satisfactory result. We propose a fundamentally new approach for ptychography probe position prediction for data with large position errors, where a neural network is used to make single-shot phase retrieval on individual diffraction patterns, yielding the object image at each scan point. The pairwise offsets among these images are then found using a robust image registration method, and the results are combined to yield the complete scan path by constructing and solving a linear equation. We show that our method can achieve good position prediction accuracy for data with large and accumulating errors on the order of 10 2 pixels, a magnitude that often makes optimization-based algorithms fail to converge. For ptychography instruments without sophisticated position control equipment such as interferometers, our method is of significant practical potential.

47 OTHER INSTRUMENTATION↗

Matter in Extreme Conditions Upgrade (Conceptual Design Report)

The Linac Coherent Light Source (LCLS) X-ray Free Electron Laser (XFEL) is an open-access user facility that delivers ultrashort X-ray pulses that are nine orders of magnitude brighter than any prior source, able to probe the characteristics of matter with unprecedented spatial and temporal precision. The Matter in Extreme Conditions (MEC) instrument at LCLS combines the XFEL with high-power, short-pulse lasers to produce and study high energy density (HED) plasmas to develop the fundamental understanding of plasmas and matter in extreme environments. This has driven a remarkably rich array of high-profile scientific results with applications in fusion energy, isotope production, advanced materials, and medical and nuclear technology. The Matter in Extreme Conditions Upgrade (MEC-U) Project proposes a major upgrade to MEC that would significantly increase the power and repetition rate of the high intensity laser system to the petawatt level (PW, 10 15 Watts) at 10 Hz, increase the energy of the shock-driver laser to the kilojoule level (kJ), and expand the capabilities of the MEC instrument to support groundbreaking experiments enabled by the combination of high-power lasers with the world’s brightest X-ray source.

36 MATERIALS SCIENCE↗

Quantitative Assessment and Measurement of X-ray Detector Performance and Solid Angle in the Analytical Electron Microscope

A wide range of X-ray detectors and geometries are available today on transmission/scanning transmission analytical electron microscopes. While there have been numerous reports of their individual performance, no single experimentally reproducible metric has been proposed as a basis of comparison between the systems. In this paper, we detail modeling, experimental procedures, measurements, and specimens which can be used to provide a manufacturer-independent assessment of the performance of an analytical system. Using these protocols, the geometrical collection efficiency, system peaks, and minimum detection limits can be independently assessed and can be used to determine the best conditions to conduct modern hyperspectral and/or spectrally resolved tomographic analyses for an individual instrument. Here, a simple analytical formula and specimen is presented which after suitable system calibrations can be used to experimentally determine the X-ray detector solid angle.

47 OTHER INSTRUMENTATION↗

XTIP – the world's first beamline dedicated to the synchrotron X-ray scanning tunneling microscopy technique

In recent years, there have been numerous efforts worldwide to develop the synchrotron X-ray scanning tunneling microscopy (SX-STM) technique. Here, the inauguration of XTIP, the world's first beamline fully dedicated to SX-STM, is reported. The XTIP beamline is located at Sector 4 of the Advanced Photon Source at Argonne National Laboratory. It features an insertion device that can provide left- or right-circular as well as horizontal- and vertical-linear polarization. XTIP delivers monochromatic soft X-rays of between 400 and 1900 eV focused into an environmental enclosure that houses the endstation instrument. This article discusses the beamline system design and its performance.

47 OTHER INSTRUMENTATION↗

Intercomparison of Aerosol Instrumental Responses Using AEROTRAK, SMPS, and APS in a Simulated Building

In this work, three aerosol instruments were intercompared by using data collected from field campaigns in a simulated building environment during the last quarter of 2020 from October to December at Oak Ridge National Laboratory. The three aerosol instruments—AeroTrak Model 9110, Scanning Mobility Particle Spectrometer (SMPS) 3080L + 3025A, and Aerodynamic Particle Sizer (APS) 3320—were manufactured by TSI Inc. to perform in situ measurements of particle number concentration in the air. These instruments were co-located in one room in which an aerosol generator was used to produce a defined aerosol population for the instruments to sample and detect in each campaign. The SMPS measured aerosol particles with diameters from 0.01 to 0.7 µm, APS measured aerosol particles with diameters from 0.5 to 20 µm, and AeroTrak measured aerosol particles with diameters from 0.1 to 10 µm. The results suggest that although AeroTrak is fast and easy to use, it does not provide measurements comparable with those obtained by SMPS and APS. The differences in particle counts were orders of magnitude in size (i.e., the AeroTrak data were unreasonably small in the tested scenarios). The results clearly indicate that AeroTrak should not be used in ambient applications in which the level of particle concentration is expected to be high. This would cause difficulty to a campaign in which the dilution factor is unknow a priori. The high particle concentration could also lead to an erroneous aerosol size distribution (e.g., a bimodal size distribution was measured as opposed to a single-mode one). The number concentration limit that AeroTrak is expected to run reliably (i.e., with a counting coincidence error less than ±10%) is approximately three to four per cubic centimeter. This suggests that the instrument is best used in a clean room environment, not in an ambient or indoor application, such as the Flexible Research Platform campaigns.

47 OTHER INSTRUMENTATION↗

Novel Harsh Environment Materials and Fabrication Techniques for Wireless Sensor Applications (Final Report)

The overarching goal of this project is to establish a center of excellence program at the University of Maine that is focused on Harsh Environmental Materials and Fabrication Techniques for Wireless Sensor Applications. UMaine is well-positioned to build on previous successes in the areas of materials science research and sensor engineering. Since 1980, the Laboratory for Surface Science & Technology (LASST) has been a very successful interdisciplinary UMaine research center with a well-established infrastructure to investigate surfaces, interfaces, thin films, and micro/nano-fabrication. This infrastructure established through NSF, DOE, DOD, NASA, the State of Maine, and industry includes (i) a 3,500 ft2 clean room with nano/microfabrication and photolithography instrumentation, (ii) thin film synthesis, processing and characterization, (iii) surface and thin film analytical chemistry tools, and (iv) device packaging, electronic testing, wireless devices, system fabrication, and sensor test facilities. This strong foundation is the basis for a planned significant growth in R&D capacity currently underway. To that end, since the start of this project in the Fall of 2019, LASST has undergone a transition to become a new interdisciplinary center at UMaine, named the Frontier Institute for Research in Sensor Technologies (FIRST). This new focus represents a commitment and investment by UMaine that aligns with the proposed DOE-EPSCoR theme, capitalizing on the state-of-the-art instrumentation to form an energized group of faculty and students pursuing advances in sensor materials, devices, and applications.

36 MATERIALS SCIENCE↗

Why would you put a flashlight in a dark matter detector?

Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, could potentially degrade the science goals of future xenon dark matter experiments. In this article, we measure the effect of external crosstalk in a dual-phase, liquid xenon time projection chamber fully instrumented with SiPMs. We then consider the implications for a future xenon dark matter experiment utilizing SiPMs and discuss possible solutions.

47 OTHER INSTRUMENTATION↗

Tomographic FLEET with a wedge array for multi-point three-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) velocimetry is an important diagnostic technique for seedless velocimetry measurements particularly in supersonic and hypersonic flows. Typical FLEET measurements feature a single laser line and camera system to achieve one-component velocimetry along a line, although some multiple-spot and multiple-component configurations have been demonstrated. In this work, tomographic imaging is used to track the three-dimensional location of many FLEET spots. A quadscope is used to combine four unique views onto a single high-speed image intensifier and camera. Tomographic reconstructions of the FLEET emission are analyzed for three-component velocimetry from multiple FLEET spots. Glass wedges are used to create many (nine) closely spaced FLEET spots with less than 10% transmission losses. These developments lead to a significant improvement in the dimensionality and spatial coverage of a FLEET instrument with some increases in experimental complexity and data processing. Multiple-point three-component FLEET velocimetry is demonstrated in an underexpanded jet.

47 OTHER INSTRUMENTATION↗

Non-contact velocity measurement instruments and systems, and related methods

Methods for calibration of non-contact velocity measurements and systems for implementing the same are described. Generally, the method comprises inducing a shock wave into a sample at a stress intensity that varies across the sample's elastic limit, which corresponds to the elastic-plastic state transition of the sample. That transition state may be at the sample's Hugoniot elastic limit. The velocity of the sample is measured using a non-contact velocity measurement instrument such as a velocimeter. The measurement may be compared to a predicted velocity or a velocity measurement made by another system to determine calibration parameters.

47 OTHER INSTRUMENTATION↗

The integrated miniaturized electrostatic analyzer: A space plasma environment sensor

The integrated Miniaturized Electrostatic Analyzer (iMESA) was a satellite-based ionospheric sensor that operated on NASA’s Space Test Program Satellite (STPSat-3) from December 2013 to July 2019. The instrument’s scientific objective was to (1) measure the plasma density in low Earth orbit, (2) measure the plasma temperature in low Earth orbit, and (3) quantify the spacecraft potential with respect to the ambient plasma potential in the ionosphere. iMESA sampled the ionosphere every 10 s by measuring the ion current density through the ESA as a result of the motion of the spacecraft through the plasma. Current density spectra were transmitted to the ground where they were post-processed into ion density spectra and then analyzed numerically to determine the ion density, ion temperature, and spacecraft potential. This article discusses the instrument design and simulation, the determination of a geometric factor, and data processing procedures and evaluates the final data product with regard to the mission success criteria. Here, the ion density and ion temperature captured by the iMESA instrument are on the same order and range as the values predicted in the literature. The spacecraft potential was also quantified. The conclusion after the evaluation of the instrument’s data product is that the scientific mission is successful on all three points.

47 OTHER INSTRUMENTATION↗

Modulation of intensity emerging from zero effort (MIEZE) with extended Fourier time at large scattering angle

Modulation of Intensity Emerging from Zero Effort (MIEZE) is a neutron resonant spin echo technique that allows one to measure time correlation scattering functions in materials by implementing radio-frequency (RF) intensity modulation at the sample and the detector. The technique avoids neutron spin manipulation between the sample and the detector and, thus, could find applications in cases where the sample depolarizes the neutron beam. However, the finite sample size creates a variance in the path length between the locations where scattering and detection happen, which limits the contrast in intensity modulation that one can detect, in particular, toward long correlation times or large scattering angles. We propose a modification to the MIEZE setup that will enable one to extend those detection limits to longer times and larger angles. Furthermore, we use Monte Carlo simulations of a neutron scattering beamline to show that by tilting the RF flippers in the primary spectrometer with respect to the beam direction, one can shape the wave front of the intensity modulation at the sample to compensate for the path variance from the sample and the detector. The simulation results indicate that this change enables one to operate a MIEZE instrument at much increased RF frequencies, thus improving the effective energy resolution of the technique. For the MIEZE instrument simulated, it shows that for an incident beam with the maximum divergence of 0.33°, the maximum Fourier time can be increased by a factor of 3.

47 OTHER INSTRUMENTATION↗

Focused Interest Groups Propel Innovation in the Emerging Data-Driven Hardware Ecosystem

Over the past several decades, the science of electron microscopy (EM) has risen to become one of the cornerstone approaches to understanding material structure, chemistry, and defects at exceptional spatial resolution. This rise can be attributed to the hard work of researchers and companies who have pushed the bounds of instrumentation and analysis, but it is also the result of advocacy by members of professional societies. Furthermore, such advocacy is exemplified by the Aberration Corrected EM (ACEM) focused interest group (FIG) of the Microscopy Society of America (MSA), which has played an important role in facilitating new hardware developments, promoting the exchange of ideas to catalyze discovery, and building the next generation of leaders in electron microscopy. From the early 2000s to the present, aberration correction has moved from proof-of-concept instrumentation to an established technique, providing unprecedented improvements in spatial and chemical resolution for breakthroughs in chemistry, physics, and materials science.

47 OTHER INSTRUMENTATION↗

Aerosol Optical Depth Best Estimate Value-Added Product Report

Four aerosol optical depth (AOD) products are offered by four collocated ground-based instruments deployed at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory (SGP Central Facility 1 [C1] and Extended Facility 13 [E13]) for more than two decades. Two of these instruments, the multifilter rotating shadowband radiometers (MFRSRs C1 and E13), are sensors with horizontal hemispherical receivers shaded by rotating shadowbands.

47 OTHER INSTRUMENTATION↗