Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

3D Imaging of the nucleon with JLab experiments

Deeply-Virtual Compton scattering and semi-inclusive meson production experiments at Jefferson Lab are probing the nucleon's partonic structure both in the transverse coordinate space (encoded in the Generalized Parton Distributions) and in the transverse momentum space (encoded in the Transverse Momentum Dependent distributions). The combination of the high-intensity, high-polarization electron beam provided by the CEBAF with the complementary equipments of the three experimental halls makes JLab an ideal enviroment for the analysis of both exclusive and semi-inclusive processes, allowing high-precision measurements of the observables of interest in a wide kinematical region. The important results obtained during the 6-GeV era will be described, together with the future studies proposed for the 12-GeV upgrade. Eventually, analyses of a large body of experimental data, collected with a high precision in an extended kinematical region, will lead to multi-dimensional space-momentum imaging of the nucleon.

Pisano, Silvia↗

Comparison of CT-derived Ventilation Maps with Deposition Patterns of Inhaled Microspheres in Rats

Purpose: Computer models for inhalation toxicology and drug-aerosol delivery studies rely on ventilation pattern inputs for predictions of particle deposition and vapor uptake. However, changes in lung mechanics due to disease can impact airflow dynamics and model results. It has been demonstrated that non-invasive, in vivo, 4DCT imaging (3D imaging at multiple time points in the breathing cycle) can be used to map heterogeneities in ventilation patterns under healthy and disease conditions. The purpose of this study was to validate ventilation patterns measured from CT imaging by exposing the same rats to an aerosol of fluorescent microspheres (FMS) and examining particle deposition patterns using cryomicrotome imaging. Materials and Methods: Six male Sprague-Dawley rats were intratracheally instilled with elastase to a single lobe to induce a heterogeneous disease. After four weeks, rats were imaged over the breathing cycle by CT then immediately exposed to an aerosol of ~1µm FMS for ~5 minutes. After the exposure, the lungs were excised and prepared for cryomicrotome imaging, where a 3D image of FMS deposition was acquired using serial sectioning. Cryomicrotome images were spatially registered to match the live CT images to facilitate direct quantitative comparisons of FMS signal intensity with the CT-based ventilation maps. Results: Comparisons of fractional ventilation in contiguous, non-overlapping, 3D regions between CT-based ventilation maps and FMS images showed strong correlations in fractional ventilation (r=0.888, p<0.0001). Conclusion: We conclude that ventilation maps derived from CT imaging are predictive of the 1µm aerosol deposition used in ventilation-perfusion heterogeneity inhalation studies.

Jacob, Rick E.↗

Parallel Infrastructure Modeling and Inversion Module for E4D

Electrical resistivity tomography ERT is a method of imaging the electrical conductivity of the subsurface. Electrical conductivity is a useful metric for understanding the subsurface because it is governed by geomechanical and geochemical properties that drive subsurface systems. ERT works by injecting current into the subsurface across a pair of electrodes, and measuring the corresponding electrical potential response across another pair of electrodes. Many such measurements are strategically taken across an array of electrodes to produce an ERT data set. These data are then processed through a computationally demanding process known as inversion to produce an image of the subsurface conductivity structure that gave rise to the measurements. Data can be inverted to provide 2D images, 3D images, or in the case of time-lapse 3D imaging, 4D images. ERT is generally not well suited for environments with buried electrically conductive infrastructure such as pipes, tanks, or well casings, because these features tend to dominate and degrade ERT images. This reduces or eliminates the utility of ERT imaging where it would otherwise be highly useful for, for example, imaging fluid migration from leaking pipes, imaging soil contamination beneath leaking subsurface tanks, and monitoring contaminant migration in locations with dense network of metal cased monitoring wells. The location and dimension of buried metallic infrastructure is often known. If so, then the effects of the infrastructure can be explicitly modeled within the ERT imaging algorithm, and thereby removed from the corresponding ERT image. However, there are a number of obstacles limiting this application. 1) Metallic infrastructure cannot be accurately modeled with standard codes because of the large contrast in conductivity between the metal and host material. 2) Modeling infrastructure in true dimension requires the computational mesh to be highly refined near the metal inclusions, which increases computational demands. 3) The ERT imaging algorithm requires specialized modifications to accommodate high conductivity inclusions within the computational mesh. The solution to each of these challenges was implemented within E4D (formerly FERM3D), which is a parallel ERT imaging code developed at PNNL (IPID #30249). The infrastructure modeling module implement in E4D uses a method of decoupling the model at the metallic interface(s) boundaries, into several well posed sub-problems (one for each distinct metallic inclusion) that are subsequently solved and recombined to form the global solution. The approach is based on the immersed interface method, with has been applied for similar problems in other fields (e.g. semiconductor industry). Comparisons to analytic solutions have shown the results to be very accurate, addressing item 1 above. The solution is implemented about an unstructured mesh, which enables arbitrary shapes to be efficiently modelled, thereby addressing item 2 above. In addition, the algorithm is written in parallel and shows excellent scalability, which also addresses equation 2 above. Finally, because only the boundaries of metallic inclusions are modeled, there are no high conductivity cells within the modeling mesh, and the problem described by item 3 above is no longer applicable.

Johnson, TimC.↗

Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy

Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dimensional (2D), requiring a skilled physician for both safety and accuracy. The authors developed a 3D US-guided biopsy system to be integrated with, and to supplement SM imaging. Their goal is to be able to biopsy a larger percentage of suspicious masses using US, by clarifying ambiguous structures with SM imaging. Features from SM and US guided biopsy were combined, including breast stabilization, a confined needle trajectory, and dual modality imaging. The 3D US guided biopsy system uses a 7.5 MHz breast probe and is mounted on an upright SM machine for preprocedural imaging. Intraprocedural targeting and guidance was achieved with real-time 2D and near real-time 3D US imaging. Postbiopsy 3D US imaging allowed for confirmation that the needle was penetrating the target. The authors evaluated 3D US-guided biopsy accuracy of their system using test phantoms. To use mammographic imaging information, they registered the SM and 3D US coordinate systems. The 3D positions of targets identified in the SM images were determined with a target localization error (TLE) of 0.49 mm. The z component (x-ray tube to image) of the TLE dominated with a TLE{sub z} of 0.47 mm. The SM system was then registered to 3D US, with a fiducial registration error (FRE) and target registration error (TRE) of 0.82 and 0.92 mm, respectively. Analysis of the FRE and TRE components showed that these errors were dominated by inaccuracies in the z component with a FRE{sub z} of 0.76 mm and a TRE{sub z} of 0.85 mm. A stereotactic mammography and 3D US guided breast biopsy system should include breast compression for stability and safety and dual modality imaging for target localization. The system will provide preprocedural x-ray mammography information in the form of SM imaging along with real-time US imaging for needle guidance to a target. 3D US imaging will also be available for targeting, guidance, and biopsy verification immediately postbiopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast GPU 3D diffeomorphic image registration

3D image registration is one of the most fundamental and computationally expensive operations in medical image analysis. Here, we present a mixed-precision, Gauss–Newton–Krylov solver for diffeomorphic registration of two images. Our work extends the publicly available CLAIRE library to GPU architectures. Despite the importance of image registration, only a few implementations of large deformation diffeomorphic registration packages support GPUs. Our contributions are new algorithms to significantly reduce the run time of the two main computational kernels in CLAIRE: calculation of derivatives and scattered-data interpolation. Additionally, we deploy (i) highly-optimized, mixed-precision GPU-kernels for the evaluation of scattered-data interpolation, (ii) replace Fast-Fourier-Transform (FFT)-based first-order derivatives with optimized 8th-order finite differences, and (iii) compare with state-of-the-art CPU and GPU implementations. As a highlight, we demonstrate that we can register clinical images in less than 6 s on a single NVIDIA Tesla V100. This amounts to over 20 speed-up over the current version of CLAIRE and over 30 speed-up over existing GPU implementations.

97 MATHEMATICS AND COMPUTING↗

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION↗

CS651 Computer Systems Security Foundations 3d Imagination Cyber Security Management Plan

3d Imagination is a new company that bases its business on selling and improving 3d open source related hardware. The devices that they sell include 3d imagers, 3d printers, pick and place machines and laser etchers. They have a fast company intranet for ease in sharing, storing and printing large, complex 3d designs. They have an employee set that requires a variety of operating systems including Windows, Mac and a variety of Linux both for running business services as well as design and test machines. There are a wide variety of private networks for testing transfer rates to and from the 3d devices, without interference with other network tra c. They do video conferencing conferencing with customers and other designers. One of their machines is based on the project found at delta.firepick.org(Krassenstein, 2014; Biggs, 2014), which in future, will perform most of those functions. Their devices all include embedded systems, that may have full blown operating systems. Most of their systems are designed to have swappable parts, so when a new technology is born, it can be quickly adopted by people with 3d Imagination hardware. This company is producing a fair number of systems and components, however to get the funding they need to mass produce quality parts, so they are preparing for an IPO to raise the funds they need. They would like to have a cyber-security audit performed so they can give their investors con dence that they are protecting their data, customers information and printers in a proactive manner.

97 MATHEMATICS AND COMPUTING↗

Time resolved 3D momentum imaging of ultrafast dynamics by coherent VUV-XUV radiation

We present a new experimental setup for measuring ultrafast nuclear and electron dynamics of molecules after photo-excitation and ionization. We combine a high flux femtosecond vacuum ultraviolet (VUV) and extreme ultraviolet (XUV) source with an internally cold molecular beam and a 3D momentum imaging particle spectrometer to measure electrons and ions in coincidence. We describe a variety of tools developed to perform pump-probe studies in the VUV-XUV spectrum and to modify and characterize the photon beam. First benchmark experiments are presented to demonstrate the capabilities of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of Single-sided 3D elemental imaging

We present single-sided 3D image reconstruction and neutron spectrum of non-nuclear material interrogated with a deuterium-tritium neutron generator. The results presented here are a proof-of-principle of an existing technique previously used for nuclear material, applied to non-nuclear material. While we do see excess signatures over background, they do not have the expected form and are currently un-identified.

36 MATERIALS SCIENCE↗

Imaging in 3D under pressure: a decade of high-pressure X-ray microtomography development at GSECARS

The high-pressure X-ray microtomography (HPXMT) apparatus has been operating at the GeoSoilEnviroCARS (GSECARS) bending magnet beamline at the Advanced Photon Source since 2005. By combining the powerful synchrotron X-ray source and fast switching between white (for X-ray diffraction) and monochromatic (for absorption imaging) modes, this technique provides the high-pressure community with a unique opportunity to image the three-dimensional volume, texture, and microstructure of materials under high pressure and temperature. The ability to shear the sample with unlimited strain by twisting the two opposed anvils in the apparatus allows shear deformation studies under extreme pressure and temperature to be performed. HPXMT is a powerful tool for studying the physical properties of both crystalline and non-crystalline materials under high pressure and high temperature. Over the past 10 years, continuous effort has been put into technical development, modifications to improve the overall performance, and additional probing techniques to meet users’ needs. Here in this paper, we present an up-to-date report on the HPXMT system, a brief review of some of its many exciting scientific applications, and a discussion of future developments.

47 OTHER INSTRUMENTATION↗

WE-AB-BRA-01: 3D-2D Image Registration for Target Localization in Spine Surgery: Comparison of Similarity Metrics Against Robustness to Content Mismatch

Purpose: In image-guided spine surgery, mapping 3D preoperative images to 2D intraoperative images via 3D-2D registration can provide valuable assistance in target localization. However, the presence of surgical instrumentation, hardware implants, and soft-tissue resection/displacement causes mismatches in image content, confounding existing registration methods. Manual/semi-automatic methods to mask such extraneous content is time consuming, user-dependent, error prone, and disruptive to clinical workflow. We developed and evaluated 2 novel similarity metrics within a robust registration framework to overcome such challenges in target localization. Methods: An IRB-approved retrospective study in 19 spine surgery patients included 19 preoperative 3D CT images and 50 intraoperative mobile radiographs in cervical, thoracic, and lumbar spine regions. A neuroradiologist provided truth definition of vertebral positions in CT and radiography. 3D-2D registration was performed using the CMA-ES optimizer with 4 gradient-based image similarity metrics: (1) gradient information (GI); (2) gradient correlation (GC); (3) a novel variant referred to as gradient orientation (GO); and (4) a second variant referred to as truncated gradient correlation (TGC). Registration accuracy was evaluated in terms of the projection distance error (PDE) of the vertebral levels. Results: Conventional similarity metrics were susceptible to gross registration error and failure modes associated with the presence of surgical instrumentation: for GI, the median PDE and interquartile range was 33.0±43.6 mm; similarly for GC, PDE = 23.0±92.6 mm respectively. The robust metrics GO and TGC, on the other hand, demonstrated major improvement in PDE (7.6 ±9.4 mm and 8.1± 18.1 mm, respectively) and elimination of gross failure modes. Conclusion: The proposed GO and TGC similarity measures improve registration accuracy and robustness to gross failure in the presence of strong image content mismatch. Such registration capability could offer valuable assistance in target localization without disruption of clinical workflow. G. Kleinszig and S. Vogt are employees of Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Advancing 3D surface imaging: single-axis structured light illumination plenoptic camera with machine learning integration

Structured light illumination (SLI) is a configurable 3D surface imaging modality that can function largely independently of surface texture. At the same time, machine learning (ML) approaches are providing new ways to capture relevant information from SLI patterns, avoiding the need to develop advanced computer vision algorithms. By projecting an optical pattern onto a surface and measuring the apparent distortion of that pattern, one can determine surface topography from a single image. Common realizations of SLI 3D imaging use off-axis SLI to allow for parallax-based determination of depth; however, in constrained geometries, the ability to make single-axis measurements can be of major benefit. While plenoptic imaging (PI) cameras have long been developed for the purpose of single-axis 3D imaging, they are generally reliant on the surface texture of the measured object, thus making them unreliable in certain experimental conditions. Therefore, we present a single-axis 3D SLI plenoptic camera, which combines the single-axis benefits of PI technology while using coaxial SLI to maintain indifference to surface conditions. We also present a study of the camera capabilities paired with the development of several algorithms, including traditional feature tracking methods as well as ML methods, which are found to enhance resolution and range. We report depth sensitivity down to 0.2% $\frac{dz}{z_0}$. The single-axis SLI 3D plenoptic camera demonstrates potential applicability for in-situ topographical measurements under a wide range of conditions including, but not limited to, objects without trackable surface texture, high temperatures, and constrained geometry environments.

Imaging systems↗

Multimodal Imaging of Autofluorescent Sites Reveals Varied Chemical Speciation in SSZ-13 Crystals

In this report a multimodal imaging study of chabazite is used to analyse emissive deposits. A notable difference is seen in the morphology of agglomerated surface deposits and larger subsurface deposits. Comparison of the distribution of organic residue throughout the crystal volume and XRF mapping is demonstrating that a fluorescence-based technique can also be used to indirectly comment on the compositional chemistry of the inorganic framework. A multimodal imaging study of chabazite is used to show the distribution of and discriminate between different emissive deposits arising as a result of the detemplation process. Confocal imaging, 3D fluorescence lifetime imaging, 3D multispectral fluorescence imaging, and Raman mapping are used to show three different types of emissive behaviours each characterised by different spatial distributions, trends in lifetime, spectral signals, and Raman signatures. A notable difference is seen in the morphology of agglomerated surface deposits and larger subsurface deposits, which experience lifetime augmentation due to spatial confinement. The distribution of organic residue throughout the crystal volume is comparable to XRF mapping that shows Si enrichment on the outer edges and higher Al content through the centre, demonstrating that a fluorescence-based technique can also be used to indirectly comment on the compositional chemistry of the inorganic framework.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accurate surface estimation from high-resolution 3D microwave images

Active millimeter and microwave imaging techniques can be used to create a high-resolution 3D image volume of a target’s reflectivity. Millimeter-wave imaging is commonly used for personnel security screening and numerous other applications. Backprojection based image reconstruction techniques form a 3D complex-valued volume. The complex-valued volume is commonly reduced to a real-valued volume by taking the magnitude. For anomaly detection and cross image registration of an object it is beneficial to generate an accurate representation of an object’s surface. Extracting a smooth and accurate surface from a magnitude only image is challenging. One difficulty is the magnitude image has limited resolution in the depth direction which normally limits precision to a moderate fraction of the depth resolution. Another difficulty is that the magnitude of the image depends heavily on the geometry and orientation of the object being imaged. The phase information in a complex-valued image volume provides a means to decouple the magnitude of the image from the geometry of an object and provide precision much finer than the depth resolution would indicate. This enables the generation of a smooth and accurate point cloud representation of the surface of an imaged object. A method to extract a point cloud from the phase information in a 3D complex-valued millimeter-wave image volume is developed and results with simulated and experimental data are presented.

Clark, Richard T.↗

3D MRI in Musculoskeletal Imaging: Current and Future Applications

Purpose of Review: This article addresses current clinical applications, recent literature, and potential future applications of 3-dimensional magnetic resonance imaging (3D MRI) for musculoskeletal (MSK) applications. Recent Findings: The main advantage of 3D MRI over standard 2-dimensional MRI is its ability to reduce partial volume averaging artifacts and create multiplanar reconstruction (MPRs) in any plane with any slice thickness from a single high-resolution isotropic acquisition. 3D MRI acquisitions are particularly useful for the evaluation of articular cartilage, which is prone to volume averaging artifacts, and for the assessment of longitudinally coursing structures such as peripheral nerves and tendons, which are better visualized with non-orthogonal MPRs. 3D MRI is also useful for surface and volumetric analysis of bone and cartilage for preoperative and longitudinal assessments. Current research is focused on decreasing acquisition times and automating segmentation through machine learning, thus overcoming some of the current limitations of 3D MRI and providing new applications for this technique. Summary: 3D MRI is widely used in MSK imaging today, and its use is likely to continue to increase in the future, with recent advancements focused on accelerated acquisition techniques and quantitative imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗