Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3-He detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Search for slow magnetic monopoles with the NOvA detector on the surface

We report a search for a magnetic monopole component of the cosmic-ray flux in a 95-day exposure of the NOvA experiment’s Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of 2 × 10 -14 cm -2 s -1 sr -1 at 90% C.L. for monopole speed 6 × 10 -4 < β < 5 × 10 -3 and mass greater than 5 × 10 8 GeV. Because of NOvA’s small overburden of 3 meters-water equivalent, this constraint covers a previously unexplored low-mass region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon to electron conversion search in the presence of Al nuclei at the Fermilab Mu2e experiment: Motivation, Design and Progress

The Mu2e experiment aims to find charged lepton flavor violation(CLFV) by measuring the monochromatic electrons from $\mu^- N\rightarrow e^- N$ conversion with an unprecedented single event sensitivity of $3 \times 10^{-17}$. When completed the experiment will improve the current limit by four orders of magnitude and make a previously unexplored phase space available for the search for beyond the standard model physics. Physics motivation for the experiment is discussed and design choices for the detectors and various sub systems are explained in this document. The construction of the Mu2e experiment is well underway and commissioning will begin in late 2022 with first data taking in late 2025 and 4-5 years of data taking thereafter to reach our goal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving ICARUS Track Reconstruction Algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino (SBN) program at Fermilab. The main goal of the experiment is to investigate the possibility of sterile neutrinos in the O(1 eV) mass region and provide clarification of the anomaly detected from the Liquid Scintillator Neutrino Detector (LSND) and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber (LAr-TPC), that can provide excellent 3D imaging and calorimetric reconstruction of any ionizing particles. This detection technique allows a detailed study of neutrino interactions, spanning a wide energy spectrum (from a few keV to several hundreds of GeV). The detector consists of two identical adjacent modules, filled with a total of 760 tons of ultra-pure liquid argon. Each module houses two LAr-TPCs separated by a common cathode with a maximum drift distance of 1.5 m, equivalent to about 1 ms drift time for the nominal $500$ V/m electric drift field. The anode is made of three parallel wire planes positioned 3 mm apart, where the stainless-steel wires are oriented on each plane at a different angle with respect to the horizontal direction ($+60^\degree$,$-60^\degree$,$0^\degree$). The first two planes (Induction 1 and Induction 2) provide a non-destructive charge measurement, whereas the ionization charge is fully collected by the last collection plane. In total, 53248 wires with a 3 mm pitch and length up to 9 m are installed in the detector. In the first stage of the reconstruction, segments of waveforms corresponding to physical signals (hits) are searched for in the deconvolved wire waveform with a threshold-based hit-finding algorithm. Each hit is then fitted with a Gaussian, whose area is proportional to the number of drift electrons generating the signal. In the second stage of the reconstruction, hits are passed as input to Pandora, a framework software composed of different pattern recognition algorithms, that performs a 3D reconstruction of the full image recorded in the collected event, including the identification of interaction vertices and tracks and showers inside the TPC. These are organized into a hierarchical structure (called slice) of particles generated starting from a primary interaction vertex. In some cases, related to the inefficiencies in the hit detection or excessive deflection of the particle trajectory, Pandora breaks the particle's track into two or more smaller pieces and considers each piece as an independent track. We studied this phenomenon focusing on primary muons from ν_μ CC interactions contained in a single module with a track at least 20 cm long, to exclude delta rays. The study determined that about $7-8\%$ of the muon tracks are broken. Approximately $80\%$ of the times, Pandora assigns all segments of the track to the same slice (intra-slice track split), while in the remaining $20\%$ of the cases, one of the segments is associated with another slice (extra-slice track split). To mitigate this phenomenon, we designed an algorithm that detects and stitches the tracks broken by Pandora for the intra-slice split. In Monte Carlo simulations, the algorithm showed an efficiency exceeding $80\%$ and a purity exceeding $93\%$.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Quantitative Modeling of High-Energy Electron Scattering in Thick Samples Using Monte Carlo Techniques

Cryo-electron microscopy (cryo-EM) is a powerful tool for imaging biological samples but is typically limited by sample thickness, which is restricted to a few hundred nanometers depending on the electron energy. However, there is a growing need for imaging techniques capable of studying biological samples up to 10 µm in thickness while maintaining nanoscale resolution. This need motivates the use of mega-electron-volt scanning transmission electron microscopy (MeV-STEM), which leverages the high penetration power of MeV electrons to generate high-resolution images of thicker samples. In this study, we employ Monte Carlo simulations to model electron–sample interactions and explore the signal decay of imaging electrons through thick specimens. By incorporating material properties, interaction cross-sections for energy loss, and experimental parameters, we investigate the relationship between the incident and transmitted beam intensities. Key factors such as detector collection angle, convergence semi-angle, and the material properties of samples were analyzed. Our results demonstrate that the relationship between incident and transmitted beam intensities follows the Beer–Lambert law over thicknesses ranging from a few microns to several tens of microns, depending on material composition, electron energy, and collection angles. The linear depth of silicon dioxide reaches 3.9 µm at 3 MeV, about 6 times higher than that at 300 keV. Meanwhile, the linear depth of amorphous ice reaches 17.9 µm at 3 MeV, approximately 11.5 times higher than that at 300 keV. These findings are crucial for advancing the study of thick biological and semiconductor samples using MeV-STEM.

36 MATERIALS SCIENCE↗

Search for Low mass Higgs Portal Scalars at the MicroBooNE Detector in the NuMI Beam

The MicroBooNE experiment exploits Liquid Argon Time Projection Chamber (LArTPC) technology to detect neutrinos from two beams at Fermilab, Chicago: on-axis Booster Neutrino Beam (BNB) and the off-axis Neutrinos at the Main Injector (NuMI) beam. While the aim of the experiment is to study the low-energy excess of electron neutrino events observed by the MiniBooNE experiment, to search for eV-scale sterile neutrinos and to characterise neutrino interactions on argon, it could also be exploited to probe Beyond Standard Model (BSM) Physics. This thesis presents a BSM search for low-mass Higgs Portal Scalars at MicroBooNE in the NuMI beam using data collected during the Run 1 and Run 3 data-taking periods with a total exposure corresponding to $7.01 \times 10^{20}$ protons on target (POT). The Higgs Portal Model is an extension to the Standard Model in which a dark-sector scalar, $S$, mixes with the Higgs boson with mixing angle $\theta$ and acquires a coupling to the Standard Model fermions via the Higgs Yukawa coupling. We search for low-mass Higgs Portal scalars, in the mass range $100-200$ MeV, at MicroBooNE via the production channel $K \rightarrow \pi + S$, where scalars are produced from kaons decaying at rest in the NuMI target and beam dump, as well as kaons decaying in flight in the decay pipe of the NuMI beam. In the MicroBooNE detector, we search for the decay channel $S \rightarrow e^+e^-$, which is the only decay channel available to the scalars in the mass range of our search. The results are expressed as limits, at the 95\% confidence level, on the scalar-Higgs mixing angle $\theta$ for scalars in the mass range $100-200$ MeV.Date of Award1 Aug 2023Original languageEnglishAwarding InstitutionThe University of ManchesterSupervisorStefan Soldner-Rembold (Supervisor) & Justin Evans (Supervisor)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High rate studies of the ATLAS sTGC detector and optimization of the filter circuit on the input of the front-end amplifier

Abstract The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5–7.5 × 10 34 cm -2 s -1 . This represents a more than 3–4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficiently in this high background rate environment. In this article, we summarize multiple performance studies of the small-strip Thin Gap Chamber (sTGC) at high rate using nearly final front-end electronics. We demonstrate that the efficiency versus rate distribution can be well described by an exponential decay with electronics dead-time being the primary cause of loss of efficiency at high rate. We then demonstrate several methods that can decrease the electronics dead-time and therefore minimize efficiency loss. One such method is to install either a pi-network input filter or pull-up resistor to minimize the charge input into the amplifier. We optimized the pi-network capacitance and pull-up resistor resistance using the results from our measurements. The results shown here were not only critical to finalizing the components on the front-end board, but also are critical for setting the optimal operating parameters of the sTGC detector and electronics in the ATLAS cavern.

Instruments & Instrumentation↗

Beam-Based Target Alignment for Mu2e

The Mu2e Experiment is a precision experiment at Fermi National Accelerator Laboratory, searching for charged lepton flavor violation (CLFV) in the conversion of a muon to an electron in the presence of an atomic nucleus. In order to achieve the expected single-event sensitivity of $3\times 10^{-17}$ , Mu2e will require an intense muon beam, generated via pion decay. These pions are the product of a proton beam striking a radiatively-cooled tungsten target. In order to maximize pion production and prevent target failure, the beam will have to be aligned with the target center to within 0.5 mm. The production target monitor (PTM) will ensure this alignment. The PTM consists of a series of proportional wire chambers (PWC’s) upstream and downstream of the production target. In this dissertation, I explain the requirements of this detector system and derive the decisions about which detector model to use and how they should be arranged from these requirements. After this, I describe my e xperience building the detectors and show an early use for them in the Mu2e proton beam. I also performed a study of the sensitivity and time resolution of this model of PWC and its electronics, and give the results here. I then describe a series of simulation campaigns which shed light on the interactions between the beam and the target, and how these interactions manifest on the downstream detectors. Finally, I give the target scanning procedure to be used to align the beam and target during experiment start up.

43 PARTICLE ACCELERATORS↗

Searching for Sterile Neutrinos In the NOvA Experiment and Measurements of Hadronic Energy Response with NOvA Test Beam Data

The NOvA (NuMI Off-Axis electron neutrino Appearance) experiment is a long-baseline neutrino oscillation experiment composed of two functionally identical detectors: a 300-ton Near Detector and a 14-kton Far Detector, separated by 809 km and placed 14 mrad off the axis of the NuMI neutrino beam created at Fermilab. This configuration enables NOvA’s rich neutrino physics program, which includes measuring neutrino mixing parameters, determining the neutrino mass hierarchy, probing CP violation in the leptonic sector, studying neutrino cross sections, searching for sterile neutrinos, and more.\\ In this thesis I will present two independent analyses developed within the NOvA experiment. The first is a search for light sterile neutrino oscillations in the 3+1 framework using $\nu_\mu$-CC and NC samples from the NOvA Near and Far Detectors. Light sterile neutrinos are hypothetical neutral leptons that do not participate in the weak interactions but can mix with the three known active neutrinos: $\nu_e$, $\nu_\mu$, and $\nu_\tau$. Anomalous results, such as $\nu_e$/$\bar{\nu}e$ appearance in a $\nu_\mu$ ($\bar{\nu}_\mu$) beam observed by the MiniBooNE and LSND experiments, can be explained by the existence of sterile neutrinos. Thus, proving the existence of this type of neutrino is essential. The latest results of these searches in the NOvA experiment, along with contributions to this effort, will be presented.\\ The second is the first measurement of the pion energy response using data from the NOvA Test Beam experiment. The NOvA Test Beam experiment, deployed at Fermilab, uses a scaled-down 30-ton NOvA detector to analyze tagged beamline particles. The beamline can select and identify electrons, muons, pions, kaons, and protons with momenta ranging from 0.4 to 1.4 GeV/c. Pions are an important component of the hadronic system in neutrino interactions, and understanding how the detector responds to these particles is crucial for the validation of the simulation and the reduction of detector calibration uncertainties, which remain one of the largest systematic uncertainties in NOvA analyses.

Dueñas Tonguino, David Francisco [Cincinnati U.] (↗

Final Search for Short-Baseline Neutrino Oscillations with the PROSPECT-I Detector at HFIR

The PROSPECT experiment is designed to perform precise searches for antineutrino disappearance at short distances (7–9 m) from compact nuclear reactor cores. This Letter reports results from a new neutrino oscillation analysis performed using the complete data sample from the PROSPECT-I detector operated at the High Flux Isotope Reactor in 2018. The analysis uses a multiperiod selection of inverse beta decay neutrino interactions with reduced backgrounds and enhanced statistical power to set limits on electron neutrino disappearance caused by mixing with sterile neutrinos with 0.2–20 eV 2 mass splittings. Inverse beta decay positron energy spectra from six different reactor-detector distance ranges are found to be statistically consistent with one another, as would be expected in the absence of sterile neutrino oscillations. The data excludes at 95% confidence level the existence of sterile neutrinos in regions above 3 eV 2 previously unexplored by terrestrial experiments, including all space below 10 eV 2 suggested by the recently strengthened Gallium Anomaly. The best-fit point of the Neutrino-4 reactor experiment’s claimed observation of short-baseline oscillation is ruled out at more than 5 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Timing-Based Search for Magnetic Monopoles with the NOvA Detector on the Surface

We report a search for a magnetic monopole component of the cosmic-ray flux in a 2743-live-day exposure of the NOvA experiment's Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of $8\times 10^{-16}~\mathrm{cm^{-2}s^{-1}sr^{-1}}$ at 90% C.L. for monopole speed $6\times 10^{-4} < β< 5\times 10^{-3}$ and mass greater than $10^{9}$ GeV. Because of NOvA's small overburden of 3 meters-water equivalent, this constraint covers a previously unexplored low-mass region.

Abubakar, S. [Erciyes U.]↗

Searches for violation of Lorentz invariance in top quark pair production using dilepton events in 13 TeV proton-proton collisions

A search for violation of Lorentz invariance in the production of top quark pairs ($t\bar{t}$) is presented. The measured normalized differential $t\bar{t}$production cross section, as a function of the sidereal time, is examined for potential modulations induced by Lorentz-invariance breaking operators in an effective field theory extension of the standard model (SM). The cross section is measured from collision events collected by the CMS detector at a center-of-mass-energy of 13 TeV, corresponding to an integrated luminosity of 77.8 fb −1 , and containing one electron and one muon. The results are found to be compatible with zero, in agreement with the SM, and are used to place upper limits at 68% confidence level on the magnitude of the Lorentz-violating couplings ranging from 1–8 × 10 −3 . This is the first precision test of the isotropy in special relativity with top quarks at the LHC, restricting further the bounds on such couplings by up to two orders of magnitude with respect to previous searches conducted at the Tevatron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mapping of inhomogeneous quasi-3D electrostatic field in electro-optic materials

Abstract This paper describes a new method for direct measurement and evaluation of the inhomogeneous electrostatic vector field with translational symmetry in electro-optic materials exhibiting the Pockels effect. It is based on the evaluation of maximum transmittance of low intensity light passing through a sample under a voltage bias. Here, the sample is located between rotating crossed polarizers, and camera images are obtained at each point to determine the electric field. The evaluation procedure is demonstrated using data acquired on a CdZnTeSe quasi-hemispheric semiconductor gamma-ray detector. In addition to CdTe-related compounds, the method can be used for various other materials showing $$\overline{4}3m$$ 4 ¯ 3 m symmetry such as GaAs, CdTe, GaP, 3C-SiC, and ZnS. Furthermore, it can be generalized to other crystalline materials showing the Pockels effect. The method can be used to probe the space charge and the electric field in several kinds of electronic components and devices, as well as provide useful data on the role of defects, contact configurations and other surface and bulk inhomogeneities in the material that can affect the distribution of the internal electric field.

36 MATERIALS SCIENCE↗

Data reduction through optimized scalar quantization for more compact neural networks

Raw data generation for several existing and planned large physics experiments now exceeds TB/s rates, generating untenable data sets in very little time. Those data often demonstrate high dimensionality while containing limited information. Meanwhile, Machine Learning algorithms are now becoming an essential part of data processing and data analysis. Those algorithms can be used offline for post processing and post data analysis, or they can be used online for real time processing providing ultra low latency experiment monitoring. Both use cases would benefit from data throughput reduction while preserving relevant information: one by reducing the offline storage requirements by several orders of magnitude and the other by allowing ultra fast online inferencing with low complexity Machine Learning models. Moreover, reducing the data source throughput also reduces material cost, power and data management requirements. In this work we demonstrate optimized nonuniform scalar quantization for data source reduction. This data reduction allows lower dimensional representations while preserving the relevant information of the data, thus enabling high accuracy Tiny Machine Learning classifier models for online fast inferences. We demonstrate this approach with an initial proof of concept targeting the CookieBox, an array of electron spectrometers used for angular streaking, that was developed for LCLS-II as an online beam diagnostic tool. We used the Lloyd-Max algorithm with the CookieBox dataset to design an optimized nonuniform scalar quantizer. Optimized quantization lets us reduce input data volume by 69% with no significant impact on inference accuracy. When we tolerate a 2% loss on inference accuracy, we achieved 81% of input data reduction. Finally, the change from a 7-bit to a 3-bit input data quantization reduces our neural network size by 38%.

97 MATHEMATICS AND COMPUTING↗

First Detection of 120 GeV Protons with Superconducting Nanowire Detectors

We report the test results for a 120 GeV proton beam incident on superconducting nanowire particle detectors of various wire sizes. NbN devices with the same sensitive area were fabricated with different wire widths and tested at a temperature of 3 K. The relative detection efficiency was extracted from bias current scans for each device. The results demonstrate efficient detection of high energy protons for wire widths less than 400 nm. These results are particularly relevant for novel applications at accelerator facilities, such as the Electron-Ion Collider, where cryogenic cooling is readily available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Improved Limits on Millicharged Particles Using the ArgoNeuT Experiment at Fermilab

A search for millicharged particles, a simple extension of the standard model, has been performed with the ArgoNeuT detector exposed to the Neutrinos at the Main Injector beam at Fermilab. The ArgoNeuT liquid argon time projection chamber detector enables a search for millicharged particles through the detection of visible electron recoils. We search for an event signature with two soft hits (MeV-scale energy depositions) aligned with the upstream target. For an exposure of the detector of 1.0×10 20 protons on target, one candidate event has been observed, compatible with the expected background. This search is sensitive to millicharged particles with charges between 10 -3 $e$ and 10 -1 $e$ and with masses in the range from 0.1 to 3 GeV. This measurement provides leading constraints on millicharged particles in this large unexplored parameter space region.

43 PARTICLE ACCELERATORS↗

A search for new physics in low-energy electron recoils from the first LZ exposure

Searches for new physics signatures in low-energy electron recoils using a fiducial LXe mass of 5.5±0.2 t tonnes over a period of 60±1 live days. The following evidences of recoiling electrons from interactions with; - Solar axions - Axion-like particles - Hidden photons - Solar neutrino magnetic moment - Solar neutrino millicharge are investigated in the study. Data reported here are from Science Run 1, which ran from 23 Dec 2021 to 11 May 2022 under stable detector conditions. Single-scatter (SS) reconstruction and analysis cuts are applied to data, and the region of interest (ROI) is defined as follows; - in the range of 3–80 phd for S1c. - in the range of uncorrected S2 greater than 600 phd and S2c less than 10^{5} phd for S2c.

Source record↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗