Artificial neural network based isotopic analysis of airborne radioactivity measurement for radiological incident detection

Responders need tools to rapidly detect and identify airborne alpha radioactivity during consequence management scenarios. Traditional continuous air monitor systems used for this purpose compute the net counts in various energy windows to determine the presence of specified isotopes, such as 235U, 239Pu, and 241Am. These calculations rely on having a well-calibrated detector, which is challenging in low-background environments. Here an alternative approach of using artificial neural networks to classify alpha spectra is presented. Two network architectures, fully connected and convolutional networks, were trained to classify alpha spectra into four categories: background and background plus the three isotopes above. Sources were injected into measured background at various fractions of the derived response level (DRL) corresponding to early-phase Protective Action Guides. The convolutional network identifies all sources at 1% of the DRL with average probability of detection of 95% and false alarm probability of 1%. Further, the network identifies sources ranging between 0.25% and 1% of the DRL with higher than 80% probability of detection and lower than 7% false alarm probability. Most significantly, the network performance improves in low-count background conditions, increasing its minimum probability of detection to 93% and reducing the false alarm probabilities to lower than 0.25%. These results show that, once trained on datasets representing a range of detection scenarios, artificial neural networks can accurately identify alpha isotopes of interest without the need for detector calibration.

Woldegiorgis, Surafel F.↗

Investigating Fission Reaction Rate Ratio Sensitivities [Abstract]

Reaction rate ratios are a measurable parameter for reactor and criticality applications. A number of foil irradiations and fission chamber measurements have been performed for critical assemblies at Los Alamos National Laboratory starting in the 1950’s including (i) Godiva, a bare HEU spherical assembly; (ii) Flattop-25, a spherical assembly consisting of an HEU core and a natural uranium reflector; (iii) Jezebel, a bare 239 Pu assembly; and (iv) Flattop-Pu, a spherical assembly consisting of a 239Pu core and a natural uranium reflector. Fission ratio data for 238 U(n,f)/ 235 U(n,f), 237 Np(n,f)/ 235 U(n,f), 233 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f) were obtained and reported. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond k-effective. Recent investigations include the use of pulsed spheres for nuclear data validation and other measurement methods of interest. One focus of the work is to determine if other methods are complimentary to the critical experiments utilized for nuclear data validation. It is anticipated the investigations will help inform methods that may be utilized in machine learning algorithms for nuclear validation. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for parameters. This work looks at reaction rate ratio sensitivities with SENSMG and Monte Carlo N-Particle R Code Version 6.21.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reactivity Coefficient Measurements to Aid in Reducing Compensating Errors in Plutonium Nuclear Data

Compensating errors between several nuclear data observables in a nuclear data library can adversely impact application simulations. The primary goal of the EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) is to reduce compensating errors between fast (0.1–5 MeV) 239Pu nuclear data for prompt fission neutron spectra (PFNS), average prompt fission neutron multiplicities, and neutron induced fission, capture, elastic, and inelastic cross sections. This work will focus on the design and execution of void reactivity coefficient measurements in the EUCLID experiment, performed on the Planet vertical lift critical assembly machine at the National Criticality Experiments Research Center (NCERC). Two different base configurations were designed and measured, one with high neutron leakage, and one with low neutron leakage. Both were primarily made up of plutonium metal (Zero Power Physics Reactor plates) without interstitial moderators and reflected by half-inch aluminum. Design optimization showed that void reactivity coefficient measurements in three locations per configuration was most impactful to reduce nuclear data uncertainties due to the varying impacts from elastic and inelastic scattering, as well as fission and capture. The locations for measurements were chosen based on preliminary studies which balanced measurement uncertainty and measurement practicality. The measurements were also selected to have sensitivities maximally complementary to previous arrangements. Comparisons across nuclear data libraries highlight the potential impact.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AN INTEGRAL REACTOR PHYSICS EXPERIMENT TO INFER ACTINIDE CAPTURE CROSS-SECTIONS FROM THORIUM TO CALIFORNIUM WITH ACCELERATOR MASS SPECTROMETRY

The principle of the proposed experiment is to irradiate very pure actinide samples in the Advanced Test Reactor (ATR) at INL and, after a given time, determine the amount of the different transmutation products. The determination of the nuclide densities before and after neutron irradiation will allow inference of effective neutron capture cross-sections. This approach has been used in the past and the novelty of this experiment is that the atom densities of the different transmutation products will be determined using the Accelerator Mass Spectroscopy (AMS) technique at the ATLAS facility located at ANL. It is currently planned to irradiate the following isotopes: 232Th, 235U, 236U, 238U, 237Np, 238Pu, 239Pu, 240Pu, 241Pu, 242Pu, 241Am, 243Am and 248Cm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A non-destructive internal nuclear forensic investigation at Argonne: discovery of a Pu planchet from 1948

A plutonium alpha standard dating from 1948 was discovered at Argonne National Laboratory and characterized using a number of non-destructive analytical techniques. The principle radioactive isotope was found to be 239 Pu and unique ring structures were found across the surface of the deposition area. Due to chronological constraints on possible sources and its high isotopic purity, the plutonium in the sample was likely produced by the Oak Ridge National Lab X-10 Reactor. As a result, it is proposed that the rings are resultant through a combination of polishing and electrodeposition, though the hypothesis fails to address a few key features of the ring structures.

239Pu↗

Quasi-differential neutron induced neutron emissions from 235 U, and 239 Pu

Uncertainty in nuclear reaction cross sections, angular distributions, and other nuclear data directly impact how well simulations of nuclear systems represent physical observations. Here, to determine how well the nuclear data in ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0 evaluations describe the physical behaviour of 235 U, and 239 Pu when subjected to a neutron flux, the neutron emission spectrum was measured for carbon, 93.0% 235 U, and 93.9% 239 Pu samples, and compared against detailed MCNP6 simulations. The measurements were performed at the Los Alamos Neutron Science Center using a quasi-differential method previously developed at Rensselaer Polytechnic Institute. The measurement spanned 0.82–20 MeV and 30–150 degrees. The measurements show there are a significant number of discrepancies between library predictions of the neutron yield and physical observation. A few of the main discrepancies found are described in this paper. Based on these results a new evaluation utilizing these results for carbon, 235 U, and 239 Pu is recommended.

235U↗

Use of Compton suppression gamma ray spectrometry to determine 239 Pu

We report 239 Pu has been characterized by gamma-ray spectroscopy for a level higher than the usual environmental ones typically needing alpha spectrometry, ICP-MS or TIMS. The higher activities typically have applications in reprocessing, safeguards verification, and nuclear forensics. For activities of hundreds of Bq/g, it is possible to use gamma ray spectrometry for 239 Pu characterization. A soil reference standard of 185 Bq/g (75 ng/g) was measured on a 79% efficient HPGe with a digital Compton suppression system. The ratios of the counting statistics for suppressed and unsuppressed uncertainties for various 239 Pu photopeaks were determined. The effects of self-attenuation on the low energy gamma rays were evaluated, and it was determined that Compton suppression was an effective characterization method of 239 Pu after accounting for self-attenuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applying a Template of Expected Uncertainties to Updating 239 Pu(n,f) Cross-section Covariances in the Neutron Data Standards Database

Templates of uncertainties expected in specific measurement types were recently developed. One aim of these templates is to help evaluators in identifying (1) missing or suspiciously low uncertainties and (2) missing correlations between uncertainties of the same and different experiments, when estimating covariances for experimental data employed in their evaluations. These templates also provide realistic estimates of standard deviations and correlations for a particular uncertainty source and measurement type that can be used by evaluators in situations where they are not supplied by the experimenters. This information allows for a more comprehensive uncertainty analysis across all measurements considered in an evaluation and, thus, more realistic evaluated covariances. Here, in this work, we extend a template that is applicable to uncertainties expected in neutron-induced fission, (n,f), cross-section measurements. It is applied to improving covariances of 239 Pu(n,f) cross-section measurements in the database underlying the Neutron Data Standards evaluations. This particular example was chosen since this evaluation is primarily based on experimental information. Also, some uncertainties of individual 239 Pu(n,f) cross-section experiments in this database were suspected to be underestimated. The evaluated uncertainties obtained after updating the covariances in the database by means of the template indeed do increase compared to their original values. Even more importantly, the evaluated mean values change noticeably. These modified cross sections impact application calculations significantly, as is demonstrated by employing them in simulations of the effective neutron multiplication factor for a few selected critical assemblies. However, this updated evaluated 239 Pu(n,f) cross section should not be interpreted as the final one that should replace values of the current Neutron Data Standards project. Evaluations for the Neutron Data Standards of the 239 Pu(n,f) cross section must be linked to many other observables included in the associated database, most notably to cross sections for 235 U(n,f), but also to those for 10 B(n, α ), 6 Li(n,t), 238 U(n,f), and 238 U(n, γ ), because of included measurements of the 239 Pu(n,f) cross section that appear as ratios to these reactions. Some of these other reactions are correlated to further observables in the database. Hence, updating uncertainties of data sets of any of these observables can potentially impact the 239 Pu(n,f) cross section. Uncertainties for all measurements of these linked physical observables have to be updated before a comprehensive evaluation of the 239 Pu(n,f) cross section and its corresponding uncertainties can be provided.

239Pu Neutron-induced fission cross-section↗

Remeasurement of the 239 Pu(n,f)/ 235 U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber Using Vapor-deposited Targets

The NIFFTE fission Time Projection Chamber (fissionTPC) has been used to measure the 239 Pu(n,f)/ 235 U(n,f) cross-section ratio for neutron-induced fission in the range of 0.1–100 MeV, with high precision. A white neutron source was provided by the Los Alamos Neutron Science Center, where the experiment was conducted as a remeasurement to evaluate a roughly 2% discrepancy of the previous fissionTPC results with ENDF/B-VIII.0. Further, a detailed accounting of measurement uncertainties was performed, based on the fissionTPC's novel ability to provide three-dimensional reconstruction of fission-fragment ionization profiles. Current results obtained using a vapor-deposited, highly uniform 239 Pu target, in comparison to the measurement published in 2021, where a 239 Pu electroplated target was used, are presented and discussed. The remeasurement presented here is in agreement with the previous fissionTPC result within measurement uncertainties.

235U↗

Evaluating 239 Pu(n,f) cross sections via machine learning using experimental data, covariances, and measurement features

In this paper, the neutron-induced 239 Pu fission cross section, 239 Pu(n,f), is evaluated from 1–20 MeV using experimental data and associated covariances while also considering information on the measurement, termed features here. For instance, methods to determine the background, sample backing material, or impurities in the sample, are explicitly taken into account in the evaluation process. To this end, outliers in the experimental data are identified with a modified version of the Hybrid Robust Support Vector Machine. In a second step, two machine learning methods (logistic regression with elastic net regularization and random forest regression with SHAP feature importance metric) are used to highlight measurement features that are common among many of the outlying data points. Based on this analysis, penalty uncertainties are added to the experimental covariances of outlying data points that have outlier measurement features and are put through the generalized-least-squares evaluation. The resulting evaluated mean values and covariances differ distinctly from those data evaluated without the penalty uncertainties. These results highlight that certain measurement features should be more closely examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Four-decade follow-up of a plutonium-contaminated puncture wound treated with Ca-DTPA

Contaminated wounds are a common route of internal deposition of radionuclides for nuclear and radiation workers. They may result in significant doses to radiosensitive organs and tissues in an exposed individual's body. The United States Transuranium and Uranium Registries' whole-body donor (Case 0303) accidentally punctured his finger on equipment contaminated with plutonium nitrate. The wound was surgically excised and medically treated with intravenous injections of Ca-DTPA. A total of 16 g Ca-DTPA was administered in 18 treatments during the 2 months following the accident. Ninety-three urine samples were collected and analysed over 14 years following the accident. An estimated 239 Pu activity of 73.7 Bq was excreted during Ca-DTPA treatment. Post-mortem radiochemical analysis of autopsy tissues indicated that 40 years post-accident 21.6 ± 0.2 Bq of 239 Pu was retained in the skeleton, 12.2 ± 0.3 Bq in the liver, and 3.7 ± 0.1 Bq in other soft tissues; 1.35 ± 0.02 Bq of 239 Pu was measured in tissue samples from the wound site. To estimate the plutonium intake, late urine measurements, which were unaffected by chelation, and post-mortem radiochemical analysis results were evaluated using the IMBA Professional Plus software. The application of the National Council on Radiation Protection and Measurements wound model with an assumption of intake material as a predominantly strongly retained soluble plutonium compound with a small insoluble fraction adequately described the data (p = 0.46). The effective intake was estimated to be 50.2 Bq of plutonium nitrate and 1.5 Bq of the fragment. Here, the prompt medical intervention with contaminated tissue excision and subsequent Ca-DTPA decorporation therapy reduced 239 Pu activity available for uptake and long-term retention in this individual's systemic organs by a factor of 38.

239Pu↗

Interpretation of nasal swab measurements following suspected releases of actinide aerosols

For radionuclides such as plutonium and americium, detection of removable activity in the nose (i.e., nasal swab measurements) are frequently used to determine whether follow-up bioassay measurements are warranted following a potential intake. For this paper, the authors analyzed 429 nasal swab measurements taken following incidents or suspicious circumstances (such as an air monitor alarming) at Los Alamos National Laboratory (LANL) for which the dose was later evaluated using in vitro bioassay. Nasal swab measurements were found to be very poor predictors of dose and should not be used as such in the field. However, nasal swab measurements can be indicative of whether a reliably detectable committed effective dose (CED) occurred. About 14% of nasal swab measurements between 1.25 and 16.7 Bq corresponded to CEDs greater than 1 mSv, so in general, positive nasal swabs always indicate that follow-up bioassay should be performed (positive nasal swabs less than 1.25 Bq are considered separately). This probability increased significantly for nasal swabs greater than 16.7 Bq. Only about 3% of nasal swabs with no detectable activity (NDA) corresponded to reliably detectable CEDs. As a result, a nasal swab with NDA is therefore necessary, but not sufficient, to negate the need for a follow-up bioassay if it was collected following other workplace indicators of a potential intake.

238Pu↗

Measurement of the 239 Pu$(n, f$) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy 1–20 MeV

Although the prompt fission neutron spectrum (PFNS) is an essential component of neutron-driven systems that has been measured for decades, there are still multiple glaring unknowns regarding the PFNS of major actinides in the fission neutron incident energy range, specifically with regard to multichance fission and pre-equilibrium neutron emission processes. The only impactful experimental 239 Pu PFNS measurements included in recent nuclear data evaluations were measured over a limited outgoing neutron energy range at thermal and 1.5-MeV average incident neutron energy, while other potentially impactful measurements have been shown to contain errors that resulted in either large uncertainty increases or in complete exclusion from nuclear data evaluation. Here, we report a measurement of the 239 Pu PFNS over a wide range of incident neutron energy (1–20 MeV) and three orders of magnitude in outgoing neutron energy (0.01–10 MeV) resulting from the Chi-Nu experiment at the Los Alamos Neutron Science Center. These results are the combination of separate PFNS measurements in the same experimental area, one using a Li-glass and the other a liquid scintillator detector array. Covariances between all PFNS data points from each detector and within each incident energy range were generated between all other data in both detector arrays and within all other incident neutron energy bins, yielding a single covariance matrix for all 1300 PFNS data points reported here. These covariances are based on a thorough assessment of systematic bias and uncertainties associated with the measurement, PFNS extraction technique, combination of data from each detector type, and other aspects of the analysis. The existence of covariances between PFNS data points in different incident neutron energy ranges yielded covariances between average PFNS energy values at each incident energy to be reported here as well, which allowed for firm statements to be made regarding a shape of a purely experimental mean PFNS energy trend for the first time. Although minor PFNS shape differences exist between the results reported here and recent nuclear data evaluations, the ENDF/B-VIII.0 and JEFF-3.3 PFNS evaluations agree reasonably well with the present results from 1-to 10-MeV incident neutron energy, which spans the well-measured 1.5-MeV incident neutron energy PFNS from Lestone and Shores as well as the onset of second-chance fission. However, while the pre-equilibrium component of the PFNS above 12-MeV incident neutron energy roughly agrees in position and magnitude with ENDF/B-VIII.0 and JEFF-3.3, clear differences relating to the relative magnitude of third-chance fission PFNS features are present in the PFNS shape and in the mean PFNS energy trends.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Langevin model of low-energy fission

Since the earliest days of fission, stochastic models have been used to describe and model the process. For a quarter century, numerical solutions of Langevin equations have been used to model fission of highly excited nuclei, where microscopic potential-energy effects have been neglected. In this paper I present a Langevin model for the fission of nuclei with low to medium excitation energies, for which microscopic effects in the potential energy cannot be ignored. I solve Langevin equations in a five-dimensional space of nuclear deformations. The macroscopic-microscopic potential energy from a global nuclear structure model well benchmarked to nuclear masses is tabulated on a mesh of approximately 10 7 points in this deformation space. The potential is defined continuously inside the mesh boundaries by use of a moving five-dimensional cubic spline approximation. Because of reflection symmetry, the effective mesh is nearly twice this size. For the inertia, I use a (possibly scaled) approximation to the inertia tensor defined by irrotational flow. A phenomenological dissipation tensor related to one-body dissipation is used. A normal-mode analysis of the dynamical system at the saddle point and the assumption of quasiequilibrium provide distributions of initial conditions appropriate to low excitation energies, and are extended to model spontaneous fission. A dynamical model of postscission fragment motion including dynamical deformations and separation allows the calculation of final mass and kinetic-energy distributions, along with other interesting quantities. The model makes quantitative predictions for fragment mass and kinetic-energy yields, some of which are very close to measured ones. Varying the energy of the incident neutron for induced fission allows the prediction of energy dependencies of fragment yields and average kinetic energies. With a simple approximation for spontaneous fission starting conditions, quantitative predictions are made for some observables which are close to measurements. In conclusion, this model is able to reproduce several mass and energy yield observables with a small number of physical parameters, some of which do not need to be varied after benchmarking to 235 U (n, f) to predict results for other fissioning isotopes.

233U↗

Total kinetic energy and mass yields from the fast neutron-induced fission of $^{239}\hbox {Pu}$

The total kinetic energy (TKE) release in fission is an important observable, constituting over 80% of the energy released in fission (E f ≈ 200MeV). While the TKE release in the 239 Pu(n,f) reaction was previously measured up to 50 MeV incident neutron energy (E n ), there were features in TKE release at the highest values of E n that were puzzling. There was a marked flattening of TKE release from E n = 30 to 50 MeV, in disagreement with the clearly decreasing TKE observed from E n = 0.5 to 30 MeV. To verify and clarify this trend, TKE measurements at higher values of E n were made. We present absolute measurements of TKE release in 239 Pu(n,f) from E n = 2.4 to 100 MeV. Here, we used silicon PIN detectors to measure the fragment energies and deduce mass-yield curves using the 2E-method. We also discuss fission asymmetry and the relationships between approx. fission fragment mass and distortion.

239Pu↗

Neutron-induced fission measurements at the DANCE and LSDS facilities at LANL

New results from neutron-induced fission measurements performed at the Detector for Advanced Neutron Capture Experiments (DANCE) and Lead Slowing Down Spectrometer (LSDS) are presented. New correlated data on prompt-fission γ-ray (PFG) distributions were measured using the DANCE array for resonant neutron-induced fission of 233 U, 235 U and 239 Pu. The deduced properties of PFG emission are presented using a simple parametrization. An accurate knowledge of fission γ-ray spectra enables us to analyze the isomeric states of 236 U created after neutron capture on 235 U. We briefly discuss these new results. Finally, we review details and preliminary results of the challenging 237 U(n,f) cross section measurement at the LSDS facility.

233U↗

Including 238 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f) NIFFTE fission TPC Cross-sections into the Neutron Data Standards Database

The primary purpose of this report is to document how the 238 U/ 235 U and 239 Pu/ 235 U neutron induced fission cross-section ratios, 238 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f), respectively, measured by the NIFFTE fission Time Projection Chamber (fissionTPC) were included in the most recent database (termed GMA) underlying Neutron Data Standards (NDS) evaluations. This report shows and discusses NDS input files, and underlying assumptions regarding the uncertainty estimate and necessary for including these data. This uncertainty estimate and the resulting files were based on information provided by fissionTPC experimentalists, R.J.Casperson, N.S. Bowden, L. Snyder and K.T. Schmitt for the 238 U ratio, and by L. Snyder for the 239 Pu ratio. The fissionTPC data were included twice, by D. Neudecker and V. Pronyaev, to counter-check results and exclude possible mistakes in their inclusion. It is shown in both evaluations that including fissionTPC 239 Pu(n,f)/ 235 U(n,f) data points to a lower evaluated 239 Pu(n,f) cross section above 10 MeV than the currently released NDS data. This raises the question whether a part of a previous dataset by Tovesson et al., that was previously rejected above 13 MeV for having low values, should be included in the NDS evaluation after all. The evaluated 238 U(n,f) cross section only changes significantly close to the threshold. The impact on the 235 U(n,f) cross section is minimal. fissionTPC data reduce evaluated uncertainties on both observables by 0–12% of the GMA evaluated uncertainties. However, the currently released NDS data contain in addition to these GMA evaluated uncertainties “Unrecognized Sources of Uncertainties” (USU) of 1.2%. It needs to be further discussed within the NDS project, whether the new fissionTPC data should also reduce USU.

238U(n,f)/235U(n,f)↗