Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Field Laboratory for Emerging Stacked Unconventional Plays in Central Appalachia

The goal of the Field Laboratory for Emerging Stacked Unconventional Plays (ESUP) in Central Appalachia project was to investigate and characterize the resource potential for multi-play production of emerging unconventional reservoirs in Central Appalachia. Project activities included drilling, logging and coring of a vertical characterization well drilled to basement to approximately 15,000 feet in depth. The data from drilling and well logs as well recovered core samples were used by the research team to support characterization of the geology and potential pay zones within the Nora Gas Field of southwestern Virginia and the greater Central Appalachian Basin. This project was led by Dr. Nino Ripepi of the Virginia Center for Coal and Energy Research (VCCER) in close collaboration with EnerVest Operating LLC (EnerVest). VCCER is housed in the Department of Mining and Minerals Engineering at Virginia Tech and was created by an Act of the Virginia General Assembly on March 30, 1977, as an interdisciplinary study, research, information, and resource facility for the Commonwealth of Virginia. EnerVest is a top tier, low-cost oil and natural gas company with a long history of traditional operating relationships with institutional investors as well as public and private companies. This report summarizes two major research activities: 1) Log and Core Analysis and 2) Numerical Modeling. Core analysis comprises the characterization efforts of the ESUP Field Laboratory and includes a discussion of the well logs run in the deep characterization wells, an initial analysis of those, the number, size and location of cores recovered, core testing and analysis done to date as well as plans for future analysis. Numerical modeling is comprised of seven major modeling efforts, including (1) Multiphysics shale transport modeling work, (2) the developed in-house compositional simulator studies, (3) reservoir modeling studies using GEM software, (4) fracture modeling work using EFRAC3D software and (5) numerical modeling efforts with ABAQUS software, (6) Numerical modeling efforts using FLAC3D and PFC3D, and (7) Automatic Machine Learning (AutoML) Studies.

02 PETROLEUM↗

Characterizing Hydraulic Fracture Propagation Before Fracture Hits

Estimating the distance from hydraulic fracture tip to monitor well can be very useful for fracture characterization, well spacing optimization, and preventing parent-child well interference. Heart-shape signal is referred to as the extensional precursor of fracture hit recorded by cross-well strain measurements and can be served as a vital tool to make such estimation. This study incorporates the 3D Displacement Discontinuity Method to understand the impact of fracture geometry and monitor well offset on the heart-shape signal’s characteristics. Results from numerical simulation and analytical solutions reveal a strong linear correlation between the spatial extent of heart shape signal and fracture tip distance. This relationship was further developed to predict tip distance using field data from the Hydraulic Fracture Test Site 2. A reasonable approximation result from field data further validates the methodology. In addition, it is worth noting that the estimation accuracy depends on the ratio between fracture dimension and tip distance. The findings of this study offer a novel approach for real-time monitoring and characterizing hydraulic fracture propagation, which can be further used for well spacing optimization in unconventional and Enhanced Geothermal System reservoir development, as well as cap rock integrity monitoring for carbon sequestration projects.

Jin, Ge↗

Web-Based Tools for Data-Informed Remedy Optimization: Software Theory and User Guide

This report documents the development and application of two web-based decision-support tools for pump-and-treat (P&T) groundwater remediation systems: PTOLEMY (Pump-and-Treat Optimized Location Evaluation to Maximize Yields) and OPTIMA (Optimization for Pump-and-Treat Implementation, Management, & Assessment). These tools enhance remedy design and management by leveraging advanced computational methods – specifically deep learning and multi-objective optimization – within a user-friendly platform. By integrating data-driven models with established hydrogeological knowledge, PTOLEMY and OPTIMA enable more efficient evaluation of well placement and operational strategies, helping site managers balance multiple remediation objectives under complex conditions. Both tools are implemented as modules within the SOCRATES (Suite Of Comprehensive Rapid Analysis Tools for Environmental Sites) web platform, which provides data access, visualization, and analytics to support remedy optimization across sites in the U.S. Department of Energy Office of Environmental Management complex. PTOLEMY is a rapid screening module designed to identify promising locations for new extraction wells. It employs a multi-channel three-dimensional convolutional neural network (MC3D-CNN) trained on high-fidelity simulation data to predict the relative performance (in terms of contaminant mass recovery) of potential well sites. Through an interactive web interface, PTOLEMY visualizes the probability of high performance across a site, highlighting areas where an extraction well is likely to yield above-threshold contaminant removal over a multi-year period. PTOLEMY’s map-based displays and exportable results support transparent communication of screening analyses. By focusing attention on the most favorable candidate locations, the tool augments traditional engineering judgment and physics-based modeling, providing a data informed basis for subsequent detailed evaluations. OPTIMA is a multi objective optimization module designed to find wellfield layouts and operating schedules that meet various cleanup goals. It quickly evaluates thousands of candidate setups – combinations of well locations, timing, and rates – and returns a small set of best trade-off options for comparison. At its core, OPTIMA uses a U-Net-based surrogate model – a deep-learning emulator of a groundwater flow and transport simulator – to dramatically accelerate scenario evaluations. Coupling this fast surrogate with the NSGA-II (Non-dominated Sorting Genetic Algorithm II) evolutionary algorithm, OPTIMA explores a wide decision space of well locations and schedules to identify Pareto-optimal solutions that trade off key objectives (e.g., minimizing cleanup time, maximizing contaminant mass removal, and minimizing plume extent). The tool outputs a family of optimal configurations and visualizes their trade-offs (Pareto frontiers of cleanup metrics and maps of optimized well placements). Site managers can use these results to understand the range of viable strategies and to select candidate designs for more detailed verification. OPTIMA is currently under active development and not yet fully released; this guide provides early documentation to support planning and gather user feedback.

54 ENVIRONMENTAL SCIENCES↗

Williston Basin Resource Study for Commercial-Scale Subsurface Hydrogen Storage

The Energy & Environmental Research Center (EERC), in partnership with the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), the EERC’s State Energy Research Center (SERC), MPLX Operations LLC, and TC Energy Development Holdings Inc. (a subsidiary of TC Energy Corporation), studied the potential for subsurface hydrogen storage and recovery in the Williston Basin of western North Dakota. The project’s goal was to evaluate the feasibility of large-scale, secure geologic H 2 storage to support future hydrogen generation, storage, and use. This work included laboratory testing, H 2 –rock–fluid exposure experiments, literature reviews on H 2 embrittlement, and reservoir modeling and simulations. The study included an assessment of storage potential across three types of storage reservoirs using both reservoir simulation and DOE’s web-based tool SHASTA-HELP (Subsurface Hydrogen Assessment, Storage, and Technology Acceleration – Hydrogen Estimator for Logistical Planning), as well as investigation of potential H 2 production and markets for commercial-scale deployment. Building on prior EERC gas storage research, three storage options were selected for detailed evaluation: the Broom Creek Formation (a clastic saline reservoir), the Dickinson Lodgepole Mounds (DLM) complex (carbonate mud mound structures) of the Lodgepole Formation (an active oil and gas producing reservoir), and the Dunham Salt Interval of the Piper Formation (to be used for engineered salt cavern development). These targets were prioritized based on prior EERC research using datasets related to seal capacity, reservoir quality, mechanical integrity, and injectivity. Exposure tests on Broom Creek and DLM samples showed mineral dissolution and precipitation that increased brine salinity and altered reservoir rock surfaces. Although these results provide useful insight, they are limited by small sample sizes and short-term (30-day) exposure, requiring further study to assess long-term storage integrity. Salt formations were not tested because of their known nonreactivity and established mechanical stability. Results of reservoir simulations performed for a single site demonstrated that the Broom Creek Formation may be capable of receiving up to 42,000 tonnes of injected H 2 over 7 months via one well. H 2 recovery took place over 5 months, resulting in approximately 26,000 tonnes (~62% without cushion gas [CG]). This work suggests water production may be important and subsequent cycles of injection and production may perform more efficiently; however, significant site-specific work in the future is needed to assess actual reservoir performance of injection and withdrawal of H 2 storage. For oil reservoir potential, a multiple-well model was used to simulate injection of approximately 32,000 tonnes of H 2 into a single wellbore while simultaneously producing in place reservoir fluids from four offset wells to maintain reservoir pressure. The simulation results suggested a high recovery (~98%); in addition, cost advantages through existing infrastructure could be realized. Challenges in this reservoir include vi managing gas purity and leakage risks. In both scenarios, production of H 2 takes place in a single-well scenario with 10 cycles (7 months of injection and 5 months of production) over 10 years. Finally, the use of engineered caverns in the Dunhan Salt was evaluated, and the results suggest that while they have a smaller capacity (<1000 tonnes per cavern), they exhibit nearly complete gas recovery (>99%), fast response times, and low purity risk. While caverns in North Dakota may be smaller in capacity, fields can be developed in galleries to accommodate the volumetric needs and rapid turnaround times necessary to meet market demands. Geographic limitations and thin salt intervals in North Dakota may represent less total storage potential than salt domes elsewhere, but significant opportunities exist to expand this market for gas storage in North Dakota. A basinwide assessment was performed to estimate a first-of-its-kind value for H 2 storage on a large scale. DOE’s SHASTA-HELP, combined with EERC simulation work, was used to perform the assessment. Estimated H 2 storage potential varied widely for each formation type. The Broom Creek saline formation was estimated to have a storage potential of approximately 1.7–90.5 million tonnes (MMt). The DLM oil reservoirs were estimated to have 0.07–0.19 MMt of capacity. Notably, each of these estimates relies on significant assumptions regarding reservoir thickness, porosity, permeability, and CG needed for operation. Much research is needed to understand the true site-specific storage resource potential of each formation. Using the Dunham Salt Interval for cavern development may result in as much as 4.79 MMt (up to 2.87 MMt working gas) of H 2 storage potential. An important note for consideration is that the values presented here need significantly more geological characterization and engineering assessments prior to gaining confidence in performance. This will be a focal point for future research and development needs. The basinwide evaluation also indicated that North Dakota has significant H 2 generation potential, with estimates up to a possible 13 MMt annually, suggesting a substantial opportunity for H 2 market development and thus the need for commercial-scale H 2 storage to facilitate growth and resilience. Key Recommendations 1. Conduct detailed site characterization (3D seismic, well logs, core sampling) to reduce geologic uncertainty. 2. Perform techno-economic analyses incorporating market, regulatory, and incentive frameworks. 3. Investigate long-term interactions among H 2 , CGs, well materials, and formations to assess risks. 4. Develop pilot- and field-scale demonstrations to validate models and establish best practices.

03 NATURAL GAS↗

Increasing Power Generation at the Patua Nevada Geothermal Field through Targeted and Adaptive EGS

In 2020, Patua Acquisition Company LLC, submitted the proposal “Increasing Power Generation at the Patua Nevada Geothermal Field through Targeted and Adaptive EGS”, in response to the DOE’s Geothermal Wells of Opportunity Funding Opportunity Announcement. The primary goal of the project was to convert an idle well, Patua 16-29, to an active producer and generate at least an additional 5 MWe at the Patua plant. The project was intended to provide an example of a reproducible methodology for well stimulation in Enhanced Geothermal Systems The project was proposed to be performed in three phases over a period of performance of four years. A first project go/no-go decision was made at the end of Phase 1 based on feasibility of the wellbore, site, and ability to realize a 5 MWe benefit from the project. Several factors were recognized that led to a no-go decision at this phase: • Electrical needs for placing the stimulated well on production were not considered in the initial scoping. Costs of pipeline costs were also underestimated in the original cost share. Easements and rights-of-way to establish a geothermal pipeline underneath or across an interstate highway were also found to be intractable on the time scale of the project. • The plant is injection limited, and no design or cost estimate was in place to handle the additional production needed to realize a 5 Mwe benefit. A new injection well would need to be drilled in addition to the other facility improvements to bring in the stimulated well. Patau Acquisition Company attempted to locate additional wells of opportunity that could realize the SOPOs goals, but was unsuccessful. As a result, this project is being terminated at the end of Phase 1.

15 GEOTHERMAL ENERGY↗

Geochemistry and Microbiology Predict Environmental Niches with Conditions Favoring Potential Microbial Activity in the Bakken Shale

The Bakken Shale and underlying Three Forks Formation is an important oil and gas reservoir in the United States. The hydrocarbon resources in this region are accessible using unconventional oil and gas extraction methods, including horizontal drilling and hydraulic fracturing. However, the geochemistry and microbiology of this region are not well understood, although they are known to have major implications for productivity and water management. In this study, we analyzed the produced water from 14 unconventional wells in the Bakken Shale using geochemical measurements, quantitative PCR (qPCR), and 16S rRNA gene sequencing with the overall goal of understanding the complex dynamics present in hydraulically fractured wells. Bakken Shale produced waters from this study exhibit high measurements of total dissolved solids (TDS). These conditions inhibit microbial growth, such that all samples had low microbial loads except for one sample (well 11), which had higher 16S rRNA gene copies. Our produced water samples had elevated chloride concentrations typical of other Bakken waters. However, they also contained a sulfate concentration trend that suggested higher occurrence of sulfate reduction, especially in wells 11 and 18. The unique geochemistry and microbial loads recorded for wells 11 and 18 suggest that the heterogeneous nature of the producing formation can provide environmental niches with conditions conducive for microbial growth. This was supported by strong correlations between the produced water microbial community and the associated geochemical parameters including sodium, chloride, and sulfate concentrations. The produced water microbial community was dominated by 19 bacterial families, all of which have previously been associated with hydrocarbon-reservoirs. These families include Halanaerobiaceae, Pseudomonadaceae, and Desulfohalobiaceae which are often associated with thiosulfate reduction, biofilm production, and sulfate reduction, respectively. Notably, well 11 was dominated by sulfate reducers. Our findings expand the current understanding of microbial life in oil and gas related environments, provide new insights into how the unique produced water conditions shape microbial communities, and demonstrate thatproduced water chemistry is tightly linked with microbiota in the Bakken Shale. Finally, our study shows that additional research efforts are necessary to understand this ecosystem and highlights the need for work in other unconventional reservoirs.

Tinker, Kara↗

Lineaments on Skylab photographs: Detection, mapping, and hydrologic significance in central Tennessee

The author has identified the following significant results. Lineaments were detected on Skylab photographs by stereo viewing, projection viewing, and composite viewing. Sixty-nine percent more lineaments were found by stereo viewing than by projection, but segments of projection lineaments are longer; total length of lineaments found by these two methods is nearly the same. Most Skylab lineaments consist of topographic depression: stream channel alinements, straight valley walls, elongated swales, and belts where sinkholes are abundant. Most of the remainder are vegetation alinements. Lineaments are most common in dissected areas having a thin soil cover. Results of test drilling show: (1) the median yield of test wells on Skylab lineaments is about six times the median yield of all existing wells; (2) three out of seven wells on Skylab lineaments yield more than 6.3 1/s (110 gal/min): (3) low yields are possible on lineaments as well as in other favorable locations; and (4) the largest well yields can be obtained at well locations of Skylab lineaments that also are favorably located with respect to topography and geologic structure, and are in the vicinity of wells with large yields.

Moore, G. K.↗

Long-Wavelength Infrared Detector

Proposed device detects infrared photons of 10- to 100-micrometer wavelength by intersubband absorption in coupled quantum wells. Based on splitting of energy level occuring when two quantum wells placed so close together wave functions of quantized energy levels overlap. Detector absorbs photons, energy which equals difference in energy between two levels resulting from split. Because degree of overlap of wave functions and, therefore, magnitude of split varied by varying width of barrier between two coupled wells, such detector, in principle, designed to operate at any desired wavelength. Restrictions on design parameters of quantum wells of proposed device less severe than single-well devices. Energy levels near tops of wells still necessary so photoexcited carriers tunnel out. Additional flexibility in design obtained by use of wells formed by barriers of different heights.

Vasquez, Richard P.↗

Resonant tunneling IR detectors

Researchers propose a novel semiconductor heterojunction photodetector which would have a very low dark current and would be voltage tunable. A schematic diagram of the device and its band structure are shown. The two crucial components of the device are a cathode (InGaAs) whose condition band edge is below the conduction band edge of the quantum wells and a resonant tunneling filter (GaAs-AlGaAs). In a standard resonant tunneling device the electrodes are made of the same material as the quantum wells, and this device becomes highly conducting when the quantum levels in the wells are aligned with the Fermi level in the negatively biased electrode. In contrast, the researchers device is essentially non-conducting under the same bias conditions. This is because the Fermi Level of the cathode (InGaAs) is still well below the quantum levels so that no resonant transport occurs and the barriers (AlGaAs) effectively block current flow through the device. However, if light with the same photon energy as the conduction-band discontinuity between the cathode and the quantum wells, E sub c3-E sub c1, is shone on the sample, free carriers will be excited to an energy corresponding to the lowest quantum level in the well closest to the cathode (hv plue E sub c1 = E sub o). These electrons will resonantly tunnel through the quantum wells and be collected as a photocurrent in the anode (GaAs). To improve the quantum efficiency, the cathode (InGaAs) should be very heavily doped and capped with a highly reflective metal ohmic contact. The thickness of the device should be tailored to optimize thin film interference effects and afford the maximum absorption of light. Because the device relies on resonant tunneling, its response should be very fast, and the small voltages needed to change the responsivity should allow for very high frequency modulation of the photocurrent. In addition, the device is tuned to a specific photon energy so that it can be designed to detect a fairly narrow range of wavelengths. This selectivity is important for reducing the photocurrent due to spurious light sources.

Woodall, Jerry M.↗

Development of a New Membrane Casting Apparatus for Studying Macrovoid Defects in Low-G

A new membrane-casting apparatus is developed for studying macrovoid defects in polymeric membranes made by the wet- and dry-casting process in low-gravity. Macrovoids are large (10-50 micron), open cavities interspersed among the smaller pores in the substructure under the gelled skin surface layer of the cast membrane. Although their occurrence is considered endemic to the wet- and dry-casting process since they can lead to compaction or skin rupture in the membrane process, recent studies suggest several useful applications such as transdermal and osmotic drug delivery systems, miniature bioreactors, etc. However, lack of knowledge about the macrovoid formation mechanism is an obstacle to further development of applications using them. An on-going debate is the role of the surface-tension-driven solutocapillary convection during macrovoid formation. The rapid growth of macrovoids within 1-5 seconds and the high polymer concentration in and near macrovoids make it difficult to explain the mechanism of macrovoid growth by diffusion alone, which is the widely accepted hypothesis proposed by Reuvers et al. The hypothesis advanced by our research group can explain this rapid growth via a mechanism that involves diffusion from the casting solution in the meta-stable region to the macrovoid enhanced by solutocapillary convection induced by the steep nonsolvent concentration gradient in the vicinity of the macrovoid. Since macrovoid growth is hypothesized to be the interplay of a solutocapillary-induced driving force counteracted by viscous drag and buoyancy, eliminate the latter provides a means for testing this hypothesis. Moreover, free convection mass transfer in the nonsolvent immersion bath used to cause phase-separation in membrane casting complicates developing a model for both the wet-casting process and macrovoid growth. The low-g environment minimizes gravitationally induced free convection thereby permitting a tractable solution to the ternary diffusion equations that characterize membrane formation. NASA's Parabolic Flight Research Aircraft provides a small window of low-g (approximately 25 s) that can be used to study macrovoid development in both wet- and dry-cast membranes if an appropriate casting apparatus is used. This casting apparatus should be able to cast the membrane in both low- and high-g in a manner so that essential one-dimensional mass transfer conditions are achieved to insure lateral uniformity in the membrane. The apparatus used in previous research on membrane casting in low-gravity was operated with the plunger driven mechanism. The spring-loaded plunger pushes the bottom block containing the polymer casting solution well directly under the absorbent chamber located in the upper stationary block. However, membranes made via this casting apparatus often displayed lateral nonuniformities that precluded obtaining quantitative information on the macrovoid growth process. Thus, it was necessary to determine the reason for these structural irregularities observed in the low-g casting apparatus. Both experimental as well as computer simulation studies of the low-g casting apparatus established that the impulsive action of the plunger caused the undesired structural nonuniformities. The simulation results showed that the width-to-depth aspect ratio of the shallow well that contains the casting solution in this apparatus was not an important factor in minimizing this problem. Even for a 40:1 (width : depth) aspect ratio, any convection induced by the horizontal motion of the interface of the casting solution will be damped out within 6.25x10(exp 4) seconds. However, the experimental studies revealed that the impulsive motion of the plunger caused a 'sloshing' of the casting solution that had to be eliminated. Therefore, the plungerdriven mechanism was changed to a cam-driven mechanism that did not cause any impulsive motion of the casting solution. Other refinements to this new membrane-casting apparatus include provision for removing the membranes from the casting wells in a less destructive manner. This was accomplished by using a slit geometry for the casting well that permitted disassembly for removal of the cast membrane. The materials used in the construction of this casting apparatus were chosen to insure wetting at the side walls and to maintain precise control of the thickness of the polymer solution in the casting well. An additional provision in this new casting apparatus is the ability to carry out both wet- as well as dry-casting. As such, this apparatus permitted the first studies of the wet-casting of polymeric membranes in low-g. Both wet- and dry-casting experiments on NASA's KC-135 research aircraft employing this new membrane-casting apparatus are scheduled in July 2002. The morphology of the resulting membranes will be characterized using an environmental scanning electron microscope (ESEM). The results of these low-g studies will be reported later.

Lee, Hanyong↗

Progress in Development of Improved Ion-Channel Biosensors

Further improvements have recently been made in the development of the devices described in Improved Ion-Channel Biosensors (NPO-30710), NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 30. As discussed in more detail in that article, these sensors offer advantages of greater stability, greater lifetime, and individual electrical addressability, relative to prior ion-channel biosensors. In order to give meaning to a brief description of the recent improvements, it is necessary to recapitulate a substantial portion of the text of the cited previous article. The figure depicts one sensor that incorporates the recent improvements, and can be helpful in understanding the recapitulated text, which follows: These sensors are microfabricated from silicon and other materials compatible with silicon. Typically, the sensors are fabricated in arrays in silicon wafers on glass plates. Each sensor in the array can be individually electrically addressed, without interference with its neighbors. Each sensor includes a well covered by a thin layer of silicon nitride, in which is made a pinhole for the formation of a lipid bilayer membrane. In one stage of fabrication, the lower half of the well is filled with agarose, which is allowed to harden. Then the upper half of the well is filled with a liquid electrolyte (which thereafter remains liquid) and a lipid bilayer is painted over the pinhole. The liquid contains a protein that forms an ion channel on top of the hardened agarose. The combination of enclosure in the well and support by the hardened agarose provides the stability needed to keep the membrane functional for times as long as days or even weeks. An electrode above the well, another electrode below the well, and all the materials between the electrodes together constitute a capacitor. What is measured is the capacitive transient current in response to an applied voltage pulse. One notable feature of this sensor, in comparison with prior such sensors, is a relatively thick dielectric layer between the top of the well and the top electrode. This layer greatly reduces the capacitance of an aperture across which the ion channels are formed, thereby increasing the signal-to-noise ratio. The use of a relatively large aperture with agarose support makes it possible to form many ion channels instead of only one, thereby further increasing the signal-to-noise ratio and effectively increasing the size of the available ionic reservoir. The relatively large reservoir makes it possible to measure AC rather than DC. This concludes the recapitulation from the cited previous article.

Nadeau, Jay L.↗

Wilson Corners SWMU 001 2014 Annual Long Term Monitoring Report Kennedy Space Center, Florida

This document presents the findings of the 2014 Long Term Monitoring (LTM) that was completed at the Wilson Corners site, located at the National Aeronautics and Space Administration (NASA) John F. Kennedy Space Center (KSC), Florida. The goals of the 2014 annual LTM event were to evaluate the groundwater flow direction and gradient and to monitor the vertical and downgradient horizontal extent of the volatile organic compounds (VOCs) in groundwater at the site. The LTM activities consisted of an annual groundwater sampling event in December 2014, which included the collection of water levels from the LTM wells. During the annual groundwater sampling event, depth to groundwater was measured and VOC samples were collected using passive diffusion bags (PDBs) from 30 monitoring wells. In addition to the LTM sampling, additional assessment sampling was performed at the site using low-flow techniques based on previous LTM results and assessment activities. Assessment of monitoring well MW0052DD was performed by collecting VOC samples using low-flow techniques before and after purging 100 gallons from the well. Monitoring well MW0064 was sampled to supplement shallow VOC data north of Hot Spot 2 and east of Hot Spot 4. Monitoring well MW0089 was sampled due to its proximity to MW0090. MW0090 is screened in a deeper interval and had an unexpected detection of trichloroethene (TCE) during the 2013 LTM, which was corroborated during the March 2014 verification sampling. Monitoring well MW0130 was sampled to provide additional VOC data beneath the semi-confining clay layer in the Hot Spot 2 area.

Monitoring↗

Paint and Oil Locker SWMU 067 Southern Treatment Area Air Sparge System Year 2 Performance Monitoring and Paint and Oil Locker Northern Area (SWMU 067) and Supply Warehouse #3, SWMU 088 Long-Term Monitoring Kennedy Space Center, Florida

This Year 2 Air Sparge (AS) System Performance Monitoring (PM) Report for Paint and Oil Locker (POL) Solid Waste Management Unit (SWMU) 067 Southern Treatment Area and Long- Term Monitoring (LTM) Report for POL Northern Area (SWMU 067) and Supply Warehouse #3 (SW3) SWMU 088 documents ongoing remedial efforts at the POL and SW3 sites at Kennedy Space Center (KSC), Florida. The overall goal for these sites is to reduce concentrations of groundwater contaminants of concern (COCs), specifically trichloroethene (TCE), cis-1,2-dichloroethene (cDCE), trans-1,2-dichloroethene (tDCE) and vinyl chloride (VC), to below the State of Florida Groundwater Cleanup Target Levels (GCTLs). Remediation and reporting of POL and SW3 have been streamlined over the years due to the proximity of the two sites. The scope for these sites currently includes two main components: (1) LTM at SW3 and the POL Northern Area, where an AS system began operation in May 2009 (with expansion in December 2012) and June 2013, respectively, and subsequently turned off for both sites in March 2018 (NASA, 2019a); and (2) Active AS operations and PM in the POL Southern Treatment Area where an AS system was installed and began operation in 2021. The timeframe for activities covered under this report is from September 2022 to July 2023. Based on Year 2 system operation and PM results, the AS system at POL operated as designed and successfully met the performance objective of reducing VOCs to concentrations that support transition of the site from active remediation to long-term monitoring. The results from the samples collected from performance monitoring wells within the AS system ROI showed a significant decrease in COC concentrations since the baseline sampling event conducted in April 2020. Based on the Year 2 OM&M and monitoring results obtained from the POL Southern Treatment Area, the IM objective to reduce concentrations to below the LTM transition target concentrations for TCE, cDCE, tDCE, and VC has been achieved. LTM sampling events at SW3 were conducted in October 2022 and July 2023. LTM sampling was conducted at the POL Northern Area in October 2022, December 2022, March 2023, and July 2023. Analytical results from October 2022 and July 2023 generally indicate that concentrations of COCs have been stable or decreasing compared to the previous year. TCE remains greater than the NADC in one monitoring well (POL-MW0034S) and greater than the GCTL in one monitoring well (POL-MW0009S). Concentrations of cDCE were greater than the GCTL in one monitoring well (POL-MW0026S), and tDCE was non-detect or less than the GCTL in all monitoring wells sampled. VC was greater than the GCTL in four monitoring wells (MW0024, MW0025, MW0027, and MW0028) at SW3 and one monitoring well (MW0026S) at the POL Northern Area.

remediation↗

The Lunar Explorer Instrument for Space Biology Applications (LEIA) Pre-Flight Tests: Mechanical Considerations​

The BioSensor payload on the upcoming LEIA platform aboard the CLPS (CP-22) lander will carry yeast to the Moon's south pole to study the effects of lunar radiation and gravity. From Earth, BioSensor will transport desiccated yeast within 16 fluidic cards, each containing 16 fluidic wells of 100 microliters volume. At the start of the experiment, these microbes will be autonomously rehydrated on the Moon, and optical absorbance measurements at three wavelengths will be performed across all 256 wells. Absorbance measurements in fluidic wells are susceptible to noise and artifacts due to bubble formation during well rehydration and microbial growth. BioSensor, as a biofluidics system, faces significant data anomalies caused by payload vibrations, particularly from the operation of the co-located PROSPECT’s ProSEED drill, to assess lunar resources by penetrating the subsurface. To evaluate the impact of drill vibrations, fully assembled and filled fluidic cards were subjected to sine sweep signals in the x, y, z planes, ranging from 5 - 2560 Hz at g-loads of 0.25 and 0.5, with on-board accelerometer for localized vibration measurement. Wells with various fill conditions, including partial fills with different bubble sizes and completely filled wells, were tested. Results indicated that small bubbles adhered to well walls at high frequencies but were dislodged at low frequencies, causing data anomalies. Medium and large bubbles exhibited higher interference with optical data due to lower surface tension and variable bubble surface flexion. Overall, it was found that irrespective of the fill type, low-frequency vibrations were most detrimental to optical readings. Understanding the drill schedule and correlating it with BioSensor timestamps will help identify periods when BioSensor data is unreliable, a crucial step for accurately interpreting the microbial response data and ensuring the validity of the BioSensor's scientific measurements on the lunar surface.

Chinmayee Govinda Raj↗

Recent Thermal and Hydraulic Stimulation Results at Raft River, ID EGS Site

The Raft River geothermal system, located 160 km northwest of Salt Lake City, Utah is the site of a Department of Energy Enhanced Geothermal System (EGS) stimulation demonstration project. The target well RRG-9 ST-1, is roughly 1.6 km (1 mile) south of the power plant. This well has undergone a series of thermal and hydraulic stimulation treatments. Furthermore, the well passes through approximately 1,524 m MD (5,000 ft. MD) of laterally discontinuous Quaternary and Tertiary volcanoclastic and volcanic rocks that unconformably overlie the Precambrian basement. The Elba Quartzite formation located in the Precambrian basement is the target zone for the stimulation program. Fluid injected into the well exits through a fracture zone in the Elba Quartzite at 1,567 m TVD (5,140 ft. TVD). In June 2013 low-rate stimulation began at RRG-9 ST-1 using injection water from the geothermal plant. The average injection rate, temperature, and well head pressure of the low-rate stimulation was 163 Lpm (43 gpm), 34°C, and 1,931kPa (280 psig), respectively. This injection continued through late August of 2013 when wellhead pressures were intentionally increased to approximately 5,516 kPa (800 psig) at approximately 984 Lpm (260 gpm). From September 12 to September 24, 2013 cold well water was injected. The average surface injection temperature was approximately 12°C. On September 25, 2013 injection of the warmer plant water was resumed. This was continued through the rest of 2013 and into 2014. Between April 1, 2014 and April 4, 2014, a higher rate hydraulic stimulation was conducted. Colder water (~10°C) was injected at rates of 20 bpm to 30 bpm (3,178 Lpm to 4,770 Lpm) at wellhead pressures of 5,861 kPa (850 psig) over approximately 24 hours. Microseismic activity was recorded near the Tertiary-Precambrian contact. Subsequently, injection of water from the plant was resumed. As of mid-January, 2015, over 666 million liters (176 million gallons) have been injected into the well. The fate of this water is the subject of ongoing numerical analyses and continuous site monitoring. Various analyses have been implemented to monitor and assess the ongoing stimulation program. Modified Hall plot analysis shows increasing conductivity and/or a decreasing skin factor around the wellbore. Since April, 2014, the injectivity index has increased significantly from 0.28 Lpm/kPa (0.5 gpm/psig) to 0.93 Lpm/kPa (1.7 gpm/psig).

enhanced geothermal system↗

Thermal Stimulation and Injectivity Testing at Raft River, ID EGS Site

The Raft River geothermal field is the site of an innovative Department of Energy Enhanced Geothermal System (EGS) project to determine the viability of using combined thermal and hydraulic stimulation techniques to improve energy production. Well RRG-9 is currently undergoing a stimulation program using injectate from the US Geothermal Raft River Power Plant and cold water from a cooling tower make-up water well. The stimulation began on 13 June 2013 with injection from the power plant at a temperature of about 39 °C and a pressure of 275 psig. Next, two positive displacement plunger type pumps were used to increase the injection pressure and flow rate for about one month. The highest rate achieved was 258 gpm at a pressure of 741 psig. During this time, fluid from the cooler water well was injected for about 2 weeks at various pressures. Then, the pumps were removed and plant injection resumed on 25 September. Plant injection will continue until the spring of 2014, when a high pressure hydraulic stimulation will be conducted. A series of seismic monitoring stations deployed around the well are providing data on seismic events occurring at the site. Over the past year, 51 microseismic events have been recorded, all less than Magnitude 1. During injection, several diagnostic tests were conducted to gain a better understanding of the well and reservoir. A step-rate test was performed on 22 August to measure the in-situ stress and aid in modeling in-situ fractures. A tracer was injected into the well on 9 September. No tracer was detected in adjacent production wells after several months. A second borehole televiewer survey was conducted for comparison to pre-stimulation images. Here, a third borehole televiewer survey is planned after the high pressure stimulation. Injection test data is evaluated in real time. A modified Hall plot analysis indicates the effective permeability is increasing. The injectivity index supports the results of the modified Hall plot analysis. As the thermal stimulation has continued, the injectivity index has consistently followed an upward trend from 0.1 gpm/psi to 0.53 gpm/psi.

enhanced geothermal systems↗

Wellbore integrity assessment with casing-based advanced sensing

Wellbore integrity is of paramount importance to subsurface resource extraction, energy storage 1 and waste disposal. After installation, well casing and cement are subject to mechanical stress due to near-well pressure changes and fluid induced corrosion. This is exacerbated for geothermal wells where produced fluid is at high temperature and corrosive. The current state-of-the-art technologies for wellbore integrity assessments are an array of cased hole logging tools. Wireline deployed acoustic, electromagnetic and mechanical tools are all available to inspect steel casing corrosion and casing-cement bond and these tools can provide high-resolution assessment of borehole conditions. They are intrusive, however, in terms of borehole preparation and interruption to the normal operation of the wells, and not suitable for high temperature or highly deviated well deployments. In addition, these measurements are performed infrequently due to high cost, and are therefore incapable of providing frequent data to better predict borehole degradation trajectory, which can help provide early warning of potential borehole failures. For this project we are developing a suite of novel, non-invasive, casing based tools for wellbore integrity assessment, combining fast/low cost screening with higher-precision investigation. Our approach is based on monitoring the response of the casing when energized at the wellhead, thereby interrogating the casing without well intervention. Lab, field and numerical approaches are used in our study. During the early stage of the research, we focus on numerical simulations, which have shown the sensitivity of the low frequency electromagnetic (EM) signals to changes in borehole depths and have successfully tested the concept at a field site with different length well casings. Initial seismic modeling efforts have also demonstrated our capability to simulate seismic tube wave and seismic field alterations due to borehole breakage and associated fluid leakage. Further numerical, laboratory and field experiments are underway for additional technology sensitivity analysis, particularly the transient EM/Seismic reflectometry methods, data acquisition optimization, and numerical simulation improvements.

Wilt, Michael↗

Integrated solid-state rapid thermo-cycling system

Techniques, systems, and devices are disclosed for implementing a portable lab system for PCR testing. An example method for operating an integrated thermal cycling system includes depositing samples into the integrated thermal cycling system that includes a thermal cycling device and an electronic interface. The thermal cycling device includes multiple wells to receive the samples to be thermally cycled, a thermoelectric cooling (TEC) element connected to the multiple wells, a substrate on which the TEC element is positioned, and a controller coupled to the TEC element. The multiple wells are positioned within the substrate that includes a thermally conductive ground positioned between adjacent wells. Supplying power to the integrated thermal cycling system, via the electronic interface, allows the multiple wells to exchange heat with the substrate and for each well to operate independently from other wells.

Beer, N. Reginald↗