Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Multipacting simulation and test results of BNL 704 MHz SRF gun

The BNL 704MHz SRF gun has a grooved choke joint to support the photo-cathode. Due to the distortion of grooves at the choke joint during the BCP for the choke joint, several multipacting barriers showed up when it was tested with Nb cathode stalk at JLab. We built a setup to use the spare large grain SRF cavity to test and condition the multipacting at BNL with various power sources up to 50kW. The test is carried out in three stages: testing the cavity performance without cathode, testing the cavity with the Nb cathode stalk that was used at Jlab, and testing the cavity with a copper cathode stalk that is based on the design for the SRF gun. This paper summarizes the results of multipacting simulation, and presents the large grain cavity test setup and the test results.

43 PARTICLE ACCELERATORS↗

SINGLE EVENT EFFECTS TEST FACILITY AT OAK RIDGE NATIONAL LABORATORY

Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of ICs and systems for use in radiation environments requires the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.

atmospheric radiation↗

Increasing Software Testing Coverage and Portability with Spack

Adequate testing coverage is critical for successful scientific software development. For numerically intensive codes, the test matrix should cover a variety of machines, compilers, third-party library dependencies, as well as possible other features such as memory testing, parallelization paradigms, and application options that may be enabled or disabled, as some examples. Such coverage can be a major burden on developers without powerful methods for managing the matrix. Spack is a great tool developed by Lawrence Livermore National Lab for managing software on a Unix-based system and in addition to this, we are leveraging Spack to simplify application testing development and management. Here we demonstrate exploiting many of Spack's features to orchestrate the test coverage for the Nalu-Wind application we are developing under the Exascale Computing Project. By using Spack underneath our testing infrastructure, we have increased our testing coverage, portability, robustness, and software quality. While we use our Nalu-Wind application as an example, the benefits of exploiting Spack for application testing can be had for other applications as well.

97 MATHEMATICS AND COMPUTING↗

A Revised Capsule Design for the Accelerated Testing of Advanced Reactor Fuels

Testing of fast reactor fuel is currently challenging because of the thermal neutron spectrum of the Advanced Test Reactor (ATR) and the fact that ATR coolant is substantially below typical temperatures found in liquid metal-cooled fast reactors. Despite these issues, since 2003 the Idaho National Laboratory (INL) has successfully tested a variety of metallic, oxide, and nitride fuels for fast reactor applications. There are, however, opportunities to improve the experiments so that the time required to reach a desired burnup can be reduced, and so the sensitivity of the experiments to fabrication tolerances can be minimized. A revised capsule design exploits the use of smaller diameter rodlets to increase power densities and correspondingly reduce the irradiation time required to reach high burnup. Thermal and nuclear analyses indicate that the time to reach 30at% burnup could be reduced from about 12 years to approximately 2-3 years if the fuel diameter is reduced by one-half and to around 1-2 years if the diameter is reduced by one-third. In addition, reducing fuel diameter improves the radial power distribution in the fuel without the use of cadmium shrouding. This observation opens up the possibility of testing advanced reactor fuel systems in Small I locations in the ATR where there is substantial unused capacity. Although not directly tied to a revised capsule design, post-irradiation furnace testing is proposed to provide time-to-failure data that will be helpful in the benchmarking of fuel performance models and in assessing the performance of new fuel designs relative to more standard fast reactor fuel systems. In this paradigm, ATR irradiation experiments will be viewed more as preparation for furnace testing than as experiments that exist in isolation. An added benefit to furnace testing is that uncertainties in temperatures will significantly be reduced relative to non-instrumented capsules in the ATR. The time and cost in developing this experimental capability is expected to be reduced considerably because of the availability of the blister anneal furnace used by the HPRR program. A key issue in the experiment approach is the potential for non-prototypical rodlet dimensions to influence the observed performance of a given fuel design. For example, a qualitative assessment indicates that the effects of fuel-cladding chemical interactions during furnace testing might be more pronounced in reduced diameter rodlets simply because thinner cladding would be more sensitive to a given depth of fission product penetration. In a traditional empirically-driven approach to fuel qualification, any change from prototypical behavior is undesirable because the resulting data cannot easily be assimilated into a statistical correlation. However, in the current approach, systematic variations in fuel diameter provide the opportunity to benchmark fuel performance models over a wider range of parameter space, which in turn is expected to improve understanding and result in better, more physically based models in the long term.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Functional and Operating Requirements for the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET)

Microreactors, or small, transportable reactors with a capacity of < 20 MWTH, are sought to provide heat and power for myriad applications in remote areas, military installations, emergency operations, humanitarian missions and disaster relief zones as illustrated in Figure 1. These small, transportable reactor designs, while offering many advantages, are largely untested and unproven. System and component testing is needed to demonstrate to regulators that these designs are safe and to convince customers that the systems are robust, reliable, and efficient. The microreactor agile non-nuclear experimental test bed (MAGNET) is being constructed at Idaho National Laboratory to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will support technology maturation to reduce uncertainty and risk relative to the operation and deployment of this unique class of systems. Stakeholders for this test bed include microreactor developers, energy users, and regulators. Regulators will be engaged early in the design and testing to expedite regulatory approval and licensing. Within MAGNET, systems and components can be safely tested, providing valuable information on operating regimes, failure modes, and thresholds. Since there are various types of microreactors being proposed, which can be classified according to their core cooling method, heat-pipes, gas-cooled (pebble bed or prismatic), molten salt, light water, or light water, the goal is to provide a test bed that is broadly applicable to multiple microreactor concepts. Each reactor type poses a different set of design and operational challenges and performance claims stated by commercial vendors have not been independently verified through rigorous testing. The initial set of tests to be performed in MAGNET are targeted towards demonstrating the feasibility and performance of heat-pipe cooled reactors, since this concept is unique to very small nuclear reactors. However, the testbed will be constructed to accommodate other designs in addition to heat-pipe cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A One System Integrated Approach to Simulant Selection for Hanford High Level Waste Mixing and Sampling Tests - 13342

The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capabilities using simulated Hanford High-Level Waste (HLW) formulations. This represents one of the largest remaining technical issues with the high-level waste treatment mission at Hanford. Previous testing has focused on very specific TOC or WTP test objectives and consequently the simulants were narrowly focused on those test needs. A key attribute in the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2 is to ensure testing is performed with a simulant that represents the broad spectrum of Hanford waste. The One System Integrated Project Team is a new joint TOC and WTP organization intended to ensure technical integration of specific TOC and WTP systems and testing. A new approach to simulant definition has been mutually developed that will meet both TOC and WTP test objectives for the delivery and receipt of HLW. The process used to identify critical simulant characteristics, incorporate lessons learned from previous testing, and identify specific simulant targets that ensure TOC and WTP testing addresses the broad spectrum of Hanford waste characteristics that are important to mixing, sampling, and transfer performance are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing Dual Rotary Filters - 12373

The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek{sup R} Rotary Micro-filter units to determine the behavior of a multiple filter system and develop a multi-filter automated control scheme. Developing and testing the control of multiple filters was the next step in the development of the rotary filter for deployment. The test stand was assembled using as much of the hardware planned for use in the field including instrumentation and valving. The control scheme developed will serve as the basis for the scheme used in deployment. The multi filter setup was controlled via an Emerson DeltaV control system running version 10.3 software. Emerson model MD controllers were installed to run the control algorithms developed during this test. Savannah River Remediation (SRR) Process Control Engineering personnel developed the software used to operate the process test model. While a variety of control schemes were tested, two primary algorithms provided extremely stable control as well as significant resistance to process upsets that could lead to equipment interlock conditions. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The equipment selected for deployment, including the concentrate discharge control valve, the pressure transmitters, and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual rotary filter system. Experience acquired on a multi-filter system behavior and with the system layout during this test helped to identify areas where the current deployment rotary filter installation design could be improved. Completion of this testing provides the necessary information on the control and system behavior that will be used in deployment on actual waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Seismic and LOCA safety testing and analysis program for Westinghouse PWR fuel under end of life conditions

The NRC issued Information Notice - IN 2012-09 in June 2012 which challenges approved assumptions based on the beginning of life (BOL) conditions in seismic and LOCA analysis. Westinghouse manufactures a variety of PWR fuel designs, including 14*14, 15*15, 16*16 and 17*17 array, also different fuel lengths from 12 feet to 14 feet. The fuels are supplied to the cores designed by Westinghouse and Combustion Engineering, and other cores around world. To address IN 2012-09 efficiently and economically, Westinghouse and PWR Owner Groups launched a testing and analysis program funded by PWROG. The program planed testing and analysis matrices based on types of fuel designs. The testing plan includes grid crush tests, fuel assembly mechanical tests and flowing water damping tests. Applying modelling technique, the program will reduce the number of test and cost. The ultimate goal of the program is to generate fuel assembly EOL models for all fuel designs manufactured by Westinghouse and to be ready for any plant specific seismic and LOCA analysis to address NRC IN for EOL effect. The phase I of PWROG for EOL conditions has been completed and several conclusions are obtained. First, the gapped grids reduce grid dynamic stiffness, local impact stiffness and crush strength. Also, due to gapped grids, both the fuel assembly natural frequency and stiffness are reduced. Secondly, applying higher fuel assembly damping due to the flowing water effect can significantly reduce fuel assembly impact forces. However, during a seismic event the reactor coolant pumps may trip resulting in a coast-down. As such, reduced flow rates that occur during the pump coast-down must be considered. Thirdly, the analytical model representation of a reactor core adequately characterizes the core response under seismic and LOCA excitations. Static and dynamic structural test results of a fuel assembly compared with analytical predictions indicate that the fuel assembly lateral and axial structural behavior can be fully determined with finite element models. Fourthly, analyses for EOL fuel assemblies under seismic and LOCA loads demonstrate EOL effect and flowing water damping effect. With flowing water damping benefit, significant margin can be recovered for fuel assemblies with EOL conditions and under seismic loads.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TREAT Transient Test Reactor Restart Status

Transient testing involves placing nuclear fuel or material into the core of a nuclear reactor designed to operate at high power for a short time, and subjecting the nuclear fuel or material to short bursts of intense, high power radiation. After the experiment is completed, the fuel or material is analyzed to determine the effects of the radiation. The results are then used in fuel or material design and/or qualification. Transient testing is required for essentially all nuclear fuel design and qualification efforts to learn how nuclear fuel will respond during accidents involving transient overpower and/or under cooling events. For example, nuclear fuel may fragment when exposed to higher than normal power. This fragmentation can cause unacceptable performance. Transient testing is also needed to validate performance models for nuclear fuel and materials. These models, when validated, will dramatically shorten the development and qualification life cycle for nuclear fuels, supporting rapid development of low emissions, reliable power generation. In the past, transient testing was primarily done in facilities that no longer exist. The U.S. Department of Energy evaluated how to provide the required transient testing capability and, following completion of the National Environmental Policy Act process, they selected the Transient Reactor Test (TREAT) facility to resume transient testing. TREAT is located at Idaho National Laboratory (INL). The TREAT reactor was used from 1959 to 1994 to conduct more than 2,500 nuclear fuel transient tests, and was placed in standby in 1994. TREAT is capable of transients in excess of 19 GW. The paper describes the progress towards restart. The restart efforts have revealed that the plant fuel and equipment is acceptable for future operations. The safety basis development, procedures, and training are well under way. Experiment capability preparations are in progress. Reactor startup is anticipated no later than 2018. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Managing Risks via Small/Pilot Scale Testing for INL's Integrated Waste Treatment Unit (IWTU) - 19268

In 2005, the THOR steam reforming fluidized-bed reactor (FBR) technology was selected by the U.S. Department of Energy (DOE) as the technology of choice for treatment of sodium- bearing waste (SBW) at the INL. The basis of the process was to use fluidized bed technology to convert an acidic radioactive nitrate-rich liquid waste into a solid carbonate product suitable for long-term disposal and storage. During initial commissioning, as well as subsequent start-ups, the plant faced many operational challenges, such as stagnant/de-fluidized bed, and wall-scale formation. Such operational issues prompted the original contractor to seek expertise in pilot-scale testing, thereby reaching out to Hazen Research Inc. (HRI, Golden, Co). Several tests were conducted, but the results did not seem to address the underlying issues observed in the full-scale plant, as evidenced by continued operational issues. A systematic approach was then taken by the Fluor-Idaho team (new contractor as of June 2016) with respect to solving these technical issues. First, two different bench-scale, 2-inch fluidized bed reactors (stainless-steal and quartz), were utilized to test several theories to better understand the underlying chemical reactions that may be taking place under expected normal operating conditions. Then, the team designed and built an 18-inch FBR unit, mimicking the full-scale main vessel at IWTU - Denitration Mineralization Reformer (DMR). This was used to test various aspects of operational challenges observed at IWTU, namely particle size control, wall-scale growth-rate control, long-term operational stability, process optimization, and process off- gas filtration challenges. An example of information obtained from bench-scale testing, which was then tested during pilot-scale testing, was the phenomena that an addition of 5 vol % of CO{sub 2} gas into the fluidizing gas system nearly eliminated the formation of agglomerates that had typically led to bed de-fluidization. This change proved to be correct in both the pilot and full-scale testing and will be implemented as part of a long-term operational strategy of IWTU. Several other findings that have provided answers with respect to IWTU operational issues will be discussed in this report. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Perspective on the Successes of the NNSS Underground Test Area (UGTA) Activity - 20221

Between 1951 and 1992, 828 underground nuclear tests were performed at the Nevada National Security Site (NNSS). Underground testing was done in five major testing areas, which included (1) Frenchman Flat, (2) Rainier Mesa/Shoshone Mountain, (3) Yucca Flat/Climax Mine (4) Central Pahute Mesa, and (5) Western Pahute Mesa. About one third of the underground tests were detonated near, at or below the water table, and thus radioactive contamination was introduced to the groundwater system. The U.S. Department of Energy's Underground Test Area (UGTA) Activity was established in the late 1990's to address the fate and movement of residual radioactivity in groundwater, and characterize the risk that it may pose to NNSS workers and the offsite public. It has accomplished this goal through a process of iterative groundwater sampling and numerical groundwater flow and transport modeling, and long-term monitoring. The UGTA Activity draws on the expertise of scientists in the fields of geology, hydrology, radiochemistry, and risk assessment from the U.S. DOE staff, the lead contractor (currently Navarro) and many other organizations, in cooperation with the governing regulatory body, the State of Nevada's Division of Environmental Protection (NDEP). Los Alamos National Laboratory (LANL) is one of the participating research organizations involved with the UGTA Activity. Under the direction of DOE and the lead contractor, LANL's role in UGTA has evolved over time from an initial focus on geologic characterization, to conducting field and laboratory experiments, and finally to its current role of providing modeling and geochemistry expertise to characterize the rates and directions of groundwater and radionuclide movement. In its current role, LANL has either developed or provided the numerical tools for developing flow and transport models in each of the four major testing areas. In addition, LANL has provided an independent assessment of future groundwater flow and transport behavior through the analysis of naturally-occurring geochemical and isotopic tracers in groundwater. The five major testing areas are now in different stages of investigation or closure: (1) Frenchman Flat is in its fifth year of post closure modeling; (2) The Rainier Mesa/Shoshone Mountain Closure Report has been submitted to NDEP and is awaiting approval; (3) The Yucca Flat/Climax Mine Closure Report is under development; and (4) Central and (5) Western Pahute Mesa is still undergoing investigation and flow and transport model development. The success of the UGTA Activity in reaching or approaching closure in three of the five major testing areas is primarily due to the DoE's focus on regulatory closure requirements, but also is in part attributable to a rigorous internal review process and the involvement of NDEP and Nye County water professionals as participants and observers in the reviews. County and state involvement in the internal review process has promoted trust that the U.S. DOE is deeply committed to ensuring the present and future safely of NNSS workers and the surrounding communities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Korean Localization Program for Performance Verification Test of APR1400's RCP

The Korean government together with the Korean nuclear society completed the development of technologies for the design, manufacturing, and performance verification test of the APR1400's Reactor Coolant Pump (RCP) as one of the national programs for the localization of deficient nuclear technology. The RCP localization program was driven by KAERI, which was responsible for the development of the performance verification and evaluation technology, and by DOOSAN heavy industrial company, which was in charge of the design and manufacturing of the RCP. The test facility for the localized APR1400's RCP was constructed at the KAERI site at the end of 2012. The thermal hydraulic and electric capability of the RCP test facility (RCPTF) covers up to 18.5 MPa, 343 deg. C, 11.7 m{sup 3}/s, and 14.0 MW for the design pressure, temperature, flow rate, and maximum electric power, respectively. In 2013, a commissioning test was performed to verify its designed capability, followed by several modifications in the RCPTF including signal processing and control logic to enhance the verification and evaluation capability of the RCP performance. After finishing the commissioning and modification of the RCPTF, a type test for the new-type of RCP was performed successfully. In 2014 and 2015, eight production tests for the localized RCPs, which will be installed in a commercial nuclear power plant in Korea, were successfully completed. As a final stage of the localization program of the RCP, KAERI will perform a seal LOCA test to verify the leakage characteristics and produce experimental data on the localized seal assembly for a safety analysis during a station black out (SBO) condition. In this summary, several technical issues developed through a series of research processes for a performance verification test of the localized RCP are described.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Counterpart Test on IBLOCA of 13% Cold Leg Break in ATLAS Facility

In the analysis for Loss-of-Coolant Accident (LOCA) as a design-basis accident (DBA) of a pressurized water reactor (PWR), redefinition of the break size based on the risk-informed regulation (RIR) is being extensively investigated due to the potential safety benefits. The pipe integrity and break frequency has been found to depend on the pipe size, so that a complete rupture of a smaller pipe such as a pressurizer surge-line or an emergency core cooling system (ECCS) nozzle is more probable than a double-ended guillotine break (DEGB) of primary coolant circuit piping. The scenario with the break of these pipes can be regarded as intermediate break (IB) LOCA. With an aim of expanding code validation to address safety issues of the IBLOCA and developing an evaluation model (EM) for full spectrum LOCA, the database for the IBLOCA test in an integral effect test (IET) facility is essential. In particular, an experimental data from the counterpart test can contribute to enhance our understanding on the phenomena and resolve the scaling issues in the scaled-down test facilities. The objective of this study is to investigate thermal hydraulic phenomena during the IBLOCA by the counterpart test for the 13% cold leg break in ATLAS facility, which was the A.2 test in the OECDATLAS project. This integral effect test would contribute to evaluate the scaling effect of the ATLAS design and test condition.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

2009 PILOT SCALE FLUIDIZED BED STEAM REFORMING TESTING USING THE THOR (THERMAL ORGANIC REDUCTION) PROCESS: ANALYTICAL RESULTS FOR TANK 48H ORGANIC DESTRUCTION - 10408

The Savannah River Site (SRS) must empty the contents of Tank 48H, a 1.3 million gallon Type IIIA HLW storage tank, to return this tank to service. The tank contains organic compounds, mainly potassium tetraphenylborate that cannot be processed downstream until the organic components are destroyed. The THOR{reg_sign} Treatment Technologies (TTT) Fluidized Bed Steam Reforming (FBSR) technology, herein after referred to as steam reforming, has been demonstrated to be a viable process to remove greater than 99.9% of the organics from Tank 48H during various bench scale and pilot scale tests. These demonstrations were supported by Savannah River Remediation (SRR) and the Department of Energy (DOE) has concurred with the SRR recommendation to proceed with the deployment of the FBSR technology to treat the contents of Tank 48H. The Savannah River National Laboratory (SRNL) developed and proved the concept with non-radioactive simulants for SRR beginning in 2003. By 2008, several pilot scale campaigns had been completed and extensive crucible testing and bench scale testing were performed in the SRNL Shielded Cells using Tank 48H radioactive sample. SRNL developed a Tank 48H non-radioactive simulant complete with organic compounds, salt, and metals characteristic of those measured in a sample of the radioactive contents of Tank 48H. FBSR Pilot Scaled Testing with the Tank 48H simulant has demonstrated the ability to remove greater than 98% of the nitrites and greater than 99.5% of the nitrates from the Tank 48H simulant, and to form a solid product that is primarily alkali carbonate. The alkali carbonate is soluble and, thus, amenable to pumping as a liquid to downstream facilities for processing. The FBSR technology was demonstrated in October of 2006 in the Engineering Scale Test Demonstration (ESTD) pilot scale steam reformer at the Hazen Research Inc. (HRI) facility in Golden, CO. Additional ESTD tests were completed in 2008 and in 2009 that further demonstrated the TTT steam reforming process ability to destroy organics in the Tank 48 simulant and produce a soluble carbonate waste form. The ESTD was operated at varying feed rates and Denitration and Mineralization Reformer (DMR) temperatures, and at a constant Carbon Reduction Reformer (CRR) temperature of 950 C. The process produced a dissolvable carbonate product suitable for processing downstream. ESTD testing was performed in 2009 at the Hazen facility to demonstrate the long term operability of an integrated FBSR processing system with carbonate product and carbonate slurry handling capability. The final testing demonstrated the integrated TTT FBSR capability to process the Tank 48 simulant from a slurry feed into a greater than 99.9% organic free and primarily dissolved carbonate FBSR product slurry. This paper will discuss the SRNL analytical results of samples analyzed from the 2008 and 2009 THOR{reg_sign} steam reforming ESTD performed with Tank 48H simulant at HRI in Golden, Colorado. The final analytical results will be compared to prior analytical results from samples in terms of organic, nitrite, and nitrate destruction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CRUSH TESTING OF 9977 GENERAL PURPOSE FISSILE PACKAGINGS

The 9977 General Purpose Fissile Package (GPFP) was designed in response to the adoption of the crush test requirement in the US regulations for packages for radioactive materials (10 CFR 71). This presentation on crush testing of the 9977 GPFP Reviews origins of Crush Test Requirements and implementation of crush test requirements in 10 CFR 71. SANDIA testing performed to support the rule making is reviewed. The differences in practice, on the part of the US Department of Energy from those required by the NRC for commercial purposes, are explained. The design features incorporated into the 9977 GPFP to enable it to withstand the crush test and the crush tests performed on the 9977 are described. Lessons learned from crush testing of GPFP packagings are given.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing and modeling of PBX-9591 shock initiation

This paper describes an ongoing effort to develop a detonation sensitivity test for PBX-9501 that is suitable for studying pristine and damaged HE. The approach involves testing and comparing the sensitivities of HE pressed to various densities and those of pre-damaged samples with similar porosities. The ultimate objectives are to understand the response of pre-damaged HE to shock impacts and to develop practical computational models for use in system analysis codes for HE safety studies. Computer simulation with the CTH shock physics code is used to aid the experimental design and analyze the test results. In the calculations, initiation and growth or failure of detonation are modeled with the empirical HVRB model. The historical LANL SSGT and LSGT were reviewed and it was determined that a new, modified gap test be developed to satisfy the current requirements. In the new test, the donor/spacer/acceptor assembly is placed in a holder that is designed to work with fixtures for pre-damaging the acceptor sample. CTH simulations were made of the gap test with PBX-9501 samples pressed to three different densities. The calculated sensitivities were validated by test observations. The agreement between the computed and experimental critical gap thicknesses, ranging from 9 to 21 mm under various test conditions, is well within 1 mm. These results show that the numerical modeling is a valuable complement to the experimental efforts in studying and understanding shock initiation of PBX-9501.

36 MATERIALS SCIENCE↗

Azura Advanced Controls 1/15th Scale Wave Tank Testing

Experimental data from the wave tank test of the Advanced control systems developed by NWEI for the Azura. Summary data is included utilizing the WEC Lab Testing Content Model v2.1. All raw and processed experimental data files are also included. The test plan and test report are included, along with the test plan and the test report from prior, passively controlled tests of the same model for reference.

16 TIDAL AND WAVE POWER↗

Development of a Testing Protocol for C7 Carbon Fiber Core Conductors

To avoid the high costs and environmental and regulatory challenges of building new lines to meet the power demand, utilities are searching for ways to increase power transmission capacity on existing lines and thereby. This could involve upgrading the network lines with conductors capable of transmitting greater capacity. In recent years, conductor manufacturers have begun producing new conductors that can operate at higher temperatures without violating present electrical clearances to ground and other objects. One new conductor technology is a carbon composite core with PPS polymer matrix and PEEK capping layer composite conductor, manufactured by Southwire Inc. The conductor uses new materials, which have not previously been used for overhead lines. The project made an initial characterization of the composite core to define the material used in the manufacture of the composite. Several analytical procedures were then conducted to evaluate the physical-chemical impacts on the composite as a result of thermal exposure. These procedures included thermogravimetry, dynamic mechanical analysis, thermal mechanical analyses, and optical microscopy. Mechanical three-point flexural tests, tensile tests, creep tests, and dynamic vibration tests were then performed to estimate the potential degradation after thermal aging. The report provides the basis to develop a qualification testing protocol for the carbon composite core at targeted service environments. The work covers the design of the qualification testing protocol and the follow-on validation testing to support the proposed methods. The research includes the following approaches: initial characterization, performance of thermal aging, characterization of the aged material, comparison of aged properties or characteristics to the original, and concluding by the findings through the developed qualification procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗