Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Use of an Uninhabited Aircraft System (UAS) for Atmospheric Observations During an Acoustic Flight Test

A jet noise test was performed at Niagara Falls International Airport using a Calspan Learjet 25 by acoustics researchers at NASA Glenn Research Center in partnership with Calspan personnel and Uninhabited Aircraft Systems (UAS) pilots and sensor operators from NASA Langley Research Center. To account for atmospheric attenuation in the de-propagation of jet noise from a ground-based microphone array to the source for comparison with model data collected in a facility at NASA GRC, a vertical profile of atmospheric conditions was required. To that end, a sUAS was flown with a weather sensor package measuring atmospheric pressure, humidity, and temperature in a range of altitudes from ground level to 304.8 m (1,000 ft) above ground level (AGL). The sUAS flights were performed concurrently with and adjacent to the Learjet flight path. Data from these UAS flights are presented herein; additionally, comparisons with conventional balloon-borne instrumentation are made with a particular focus on the quality and capability of UAS-based observations for acoustic flight test applications. Furthermore, a ground-based light detection and ranging (LiDAR) system was deployed for collecting wind magnitude and direction for discrete altitudes up to 304.8 m (1,000 ft) AGL. Data from the LiDAR unit will be presented and discussed in the context of aircraft acoustic flight testing. This effort was supported by NASA’s Commercial Supersonic Technology project.

UAS↗

Advanced Collision Detection and Site Monitoring for Avian and Bat Species for Offshore Wind Energy (Final Technical Report)

This final technical report summarizes the outcomes from a project that aimed to design, build, and test a persistent and autonomous monitoring system for avian and bat collisions with offshore wind turbines blades and structures. The system comprises four primary sensor modules: 1) on-blade sensor modules for collision detection and dual-vision image capture on each blade with both visible light and near-infrared imagers; 2) additional on-blade collision sensors mounted further from the root; 3) a nacelle-mounted unit including a 360º camera and ultrasonic microphone array; and, 4) an on-blade, high-performance infrared camera module. Primary targeted outcomes were high sensitivity for the detection of blade strikes from bats and small birds, and automatically captured visual confirmation of the striking object; these features are critical for monitoring offshore wind turbine installations, where ground-based methods are not viable. In addition, local recording will provide a long-term sensor recording database. Following laboratory validation, field testing was conducted on an operational wind turbine in collaboration with the National Wind Technology Center at the NREL Flatirons campus over two planned field tests.

17 WIND ENERGY↗

Optical Processes behind Plasmonic Applications

Plasmonics is a revolutionary concept in nanophotonics that combines the properties of both photonics and electronics by confining light energy to a nanometer-scale oscillating field of free electrons, known as a surface plasmon. Generation, processing, routing, and amplification of optical signals at the nanoscale hold promise for optical communications, biophotonics, sensing, chemistry, and medical applications. Surface plasmons manifest themselves as confined oscillations, allowing for optical nanoantennas, ultra-compact optical detectors, state-of-the-art sensors, data storage, and energy harvesting designs. Surface plasmons facilitate both resonant characteristics of nanostructures and guiding and controlling light at the nanoscale. Plasmonics and metamaterials enable the advancement of many photonic designs with unparalleled capabilities, including subwavelength waveguides, optical nanoresonators, super- and hyper-lenses, and light concentrators. Alternative plasmonic materials have been developed to be incorporated in the nanostructures for low losses and controlled optical characteristics along with semiconductor-process compatibility. This review describes optical processes behind a range of plasmonic applications. It pays special attention to the topics of field enhancement and collective effects in nanostructures. The advances in these research topics are expected to transform the domain of nanoscale photonics, optical metamaterials, and their various applications.

2D materials↗

High-voltage space-plasma interactions measured on the PASP Plus test arrays

The Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) experiment was developed by the Air Force's Phillips Laboratory with support from NASA's Lewis Research Center. It was launched on the Advanced Photovoltaic and Electronics EXperiments (APEX) satellite on August 3, 1994 into a 70 degree inclination, 363 km by 2550 km elliptical orbit. This orbit allows the investigation of space plasma effects on high-voltage operation (leakage current at positive voltages and arcing at negative voltages) in the perigee region. PASP Plus is testing twelve solar arrays. There are four planar Si arrays: an old standard type (used as a reference), the large-cell Space Station Freedom (SSF) array, a thin 'APSA' array, and an amorphous Si array. Next are three GaAs on Ge planar arrays and three new material planar arrays, including InP and two multijunction types. Finally, there are two concentrator arrays: a reflective-focusing Mini-Cassegrainian and a Fresnel-lens focusing Mini-Dome. PASP Plus's diagnostic sensors include: Langmuir probe to measure plasma density, an electrostatic analyzer (ESA) to measure the 30 eV to 30 KeV electron/ion spectra and determine vehicle negative potential during positive biasing, and a transient pulse monitor (TPM) to characterize the arcs that occur during the negative biasing. Through positive biasing of its test arrays, PASP Plus investigated the snapover phenomenon, which took place over the range of +100 to +300 V. It was found that array configurations where the interconnects are shielded from the space plasma (i.e., the concentrators or arrays with 'wrap-through' connectors) have lower leakage current. The concentrators exhibited negligible leakage current over the whole range up to +500 V. In the case of two similar GaAs on Ge arrays, the one with 'wrap-through' connectors had lower leakage current than the one with conventional interconnects. Through negative biasing, PASP Plus investigated the arcing rates of its test arrays. The standard Si array, with its old construction (exposed rough-surface interconnects), arced significantly over a wide voltage and plasma-density range. The other arrays arced at very low rates, mostly at voltages greater than -350 V and plasma densities near or greater than 10(exp 5)/cm(exp -3). AS expected according to theory, arcing was more prevalent when array temperatures were cold (based on biasing in eclipse).

Guidice, Donald A.↗

The Source Physics Experiment Large N Array

To improve the understanding of S wave generation from an explosion, a temporary deployment of 996 geophones, including both one component (Z) and three component sensors (3C), was installed from April 15 to May 23, 2016 at the Nevada National Security Site (NNSS). Sensor spacing varied from 25 to 100 m and consisted of 500 Z and 496 3C 5-Hz geophones. Data were continuously recorded during the deployment at low-gain (0 db) from April 15 to April 28 and high-gain (36 db) from April 29 to May 23. A buried (76.5 m depth) 5035 kg TNT equivalent chemical explosion (SPE-5) was recorded on April 26. It was situated in a weathered granite body surrounded by volcanic tuffs, Paleozoic carbonates, and alluvium. The array was deployed approximately 400 to 3000 m from the explosion. A set of large weight-drop shots (13,000 kg source) at 53 locations both inside and outside the geophone array were also recorded, as were local, regional, and teleseismic earthquakes. Data recovery was good, with 95% of data recovered from the chemical explosion and up to 99% in the following weeks, including both the weightdrop shots campaign and the continuous data. Important initial results from the deployment include estimates of the spatial correlation length of velocity heterogeneities and a higher resolution velocity model. Observations of the data and synthetics, indicate that some far-field (elastic) S wave energy is generated by scattering and conversion outside the near-field (inelastic) region. Interferometric processing was conducted on a Hadoop ‘big-data’ cluster.

58 GEOSCIENCES↗

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

NIST: Soil Respiration, Moisture, Temperature, Chemistry; and Fine Root Measurements from a Transect Through a Forest Edge, Gaithersburg, Maryland, 2017-2021

This dataset contains soil respiration, moisture, temperature, and chemistry, as well as fine root measurements from the National Institute of Standards and Technology (NIST) Forested Optical Reference for Evaluating Sensor Technology (FOREST) research facility at Gaithersburg, Maryland. Measurements were taken at an existing transect array that begins in a grassy meadow, crosses a sharp forest edge, then a small stream, and finally extends upwards in the interior of the forest at the top of a ridge. There are 6 different landscape positions replicated across three transects in the array. Soil respiration was measured during growing seasons in 2017-2019 (2017-06-02 to 2020-02-27). Pedons (1 m3) were isolated from surrounding tree roots using trenching and a fabric to inhibit root ingrowth. Flux measurements inside the pedons were thus assumed to represent heterotrophic only respiration in 2019, and these fluxes were paired with nearby fluxes assumed to represent total respiration. Deep vertical probes measured volumetric moisture content and temperature at the same points in the array every 10 cm in depth to either 90 cm or 120 cm total depth, at 15 minute intervals, from 2019-2021 (2019-07-09 to 2021-09-10). Soil core samples were collected from each of the array points for three different months in early- to mid-2019 (2019-03-19 to 2019-07-10), at three depths each. Soils were analyzed for gravimetric moisture content; pH; total carbon, nitrogen, and phosphorus; texture; microbial biomass carbon, nitrogen, and phosphorus; extractable dissolved organic carbon, nitrogen, and phosphorus; extractable nitrate and ammonia; and extracellular hydrolytic enzyme activities. The fine roots were separated from the cores and segregated by plant functional type (grass or tree species) and if they were dead or alive. Fine roots were then measured for length, surface area, diameter, and dry mass. This dataset contains four data files in comma separated (*.csv) format. These data serve to deepen our understanding of root and soil processes at forest edges and in transitional zones.

54 ENVIRONMENTAL SCIENCES↗

Absolute radiometric calibration of advanced remote sensing systems

The distinction between the uses of relative and absolute spectroradiometric calibration of remote sensing systems is discussed. The advantages of detector-based absolute calibration are described, and the categories of relative and absolute system calibrations are listed. The limitations and problems associated with three common methods used for the absolute calibration of remote sensing systems are addressed. Two methods are proposed for the in-flight absolute calibration of advanced multispectral linear array systems. One makes use of a sun-illuminated panel in front of the sensor, the radiance of which is monitored by a spectrally flat pyroelectric radiometer. The other uses a large, uniform, high-radiance reference ground surface. The ground and atmospheric measurements required as input to a radiative transfer program to predict the radiance level at the entrance pupil of the orbital sensor are discussed, and the ground instrumentation is described.

Slater, P. N.↗

Absolute radiometric calibration of advanced remote sensing systems

The distinction between the uses of relative and absolute spectroradiometric calibration of remote sensing systems is discussed. The advantages of detector-based absolute calibration are described, and the categories of relative and absolute system calibrations are listed. The limitations and problems associated with three common methods used for the absolute calibration of remote sensing systems are addressed. Two methods are proposed for the in-flight absolute calibration of advanced multispectral linear array systems. One makes use of a sun-illuminated panel in front of the sensor, the radiance of which is monitored by a spectrally flat pyroelectric radiometer. The other uses a large, uniform, high-radiance reference ground surface. The ground and atmospheric measurements required as input to a radiative transfer program to predict the radiance level at the entrance pupil of the orbital sensor are discussed, and the ground instrumentation is described. Previously announced in STAR as N83-28544

Slater, P. N.↗

Multispectral Linear Array detector technology

The Multispectral Linear Array (MLA) program sponsored by NASA has the aim to extend space-based remote sensor capabilities. The technology development effort involves the realization of very large, all-solid-state, pushbroom focal planes. The pushbroom, staring focal planes will contain thousands of detectors with the objective to provide two orders of magnitude improvement in detector dwell time compared to present Landsat mechanically scanned systems. Attenton is given to visible and near-infrared sensor development, the shortwave infrared sensor, aspects of filter technology development, the packaging concept, and questions of system performance. First-sample, four-band interference filters have been fabricated successfully, and a hybrid packaging technology is being developed.

Tower, J. R.↗

Deep, Precise Etching in Semiconductors

Semiconductors made to accept precise etching after pretreatment. Combination of material destabilization and anisotropic etching permits formation of precise perpendicular-wall cavities in silicon wafers and other semiconductors. New technique extends capabilities of current micromachining technology to fabrication of submillimeter waveguide arrays and filters. Pre-etching process currently used to fabricate thin-walled arrays of submillimeter waveguides for use as dichroic bandpass filters. Possible applications include integration of sensor probes and processing of circuitry on same silicon chip.

Shlichta, P. J.↗

Airborne imaging spectrometer II - The optical design

The Airborne Imaging Spectrometer (AIS I) was a multispectral infrared imaging instrument utilizing a 32 x 32 element mercury-cadmium-telluride detector array. A novel optical design provided high spectral resolution and, in conjunction with the 32-element spatial resolution, made optimal use of the capabilities of the area array. The operational successes of this proof-of-concept instrument, coupled with advances in infrared detector array technology, have provided the impetus and opportunity to upgrade the instrument by replacing the sensor with a newly developed 64 x 64 detector. The original instrument configuration is reviewed, and the design considerations, limitations and trade-offs necessitated by the new detector are examined, particularly the near doubling of the field of view and the increase from 1024 to 4096 pixels per read-out frame.

La Baw, Clayton↗

An augmented MMS MACS for the Topex/Poseidon mission and beyond

The augmented Modular Attitude Control Subsystem (MACS) is described, with emphasis on the significant hardware modifications that have been incorporated into the Landsat MMS (Multimission Modular Spacecraft) MACS design to satisfy the Topex/Poseidon mission attitude control and determination requirements. Particular attention is given to a modification consisting in the addition of an earth pointing safe hold mode utilizing yaw coarse sun sensors to provide a yaw-slew capability for maintaining adequate illumination of the solar array. The design utility of this augmented MACS module for future spacecraft applications is pointed out.

Williams, R. J.↗

Pyroelectric Applications of the VDF-TrFE Copolymer

VDF/TrFe pyroelectric sensors have now definitely reached the level of a product. Based on a bidimensional staring array, it can be considered as a whole system with a monolithic technology processed on a silicon substrate provided with the integrated read out circuit. The paper will describe the main procedure dealing with the elaboration of a 32 x 32 focal plane array developed, in the context of the PROMETHEUS PROCHIP European Program (EUREKA), as a passive infrared obstacle detection applied to automotive. Additional experimental data suggest that this microsystem could operate in space environment.

Simonne, J. J.↗

Detectors for the James Webb Space Telescope Near-Infrared Spectrograph

The Near-Infrared Spectrograph (NIRSpec) is the James Webb Space Telescope's primary near-infrared spectrograph. NASA is providing the NIRSpec detector subsystem, which consists of the focal plane array, focal plane electronics, cable harnesses, and software. The focal plane array comprises two closely-butted lambda (sub co) approximately 5 micrometer Rockwell HAWAII- 2RG sensor chip assemblies. After briefly describing the NIRSpec instrument, we summarize some of the driving requirements for the detector subsystem, discuss the baseline architecture (and alternatives), and presents some recent detector test results including a description of a newly identified noise component that we have found in some archival JWST test data. We dub this new noise component, which appears to be similar to classical two-state popcorn noise in many aspects, "popcorn mesa noise." We close with the current status of the detector subsystem development effort.

Rauscher, Bernard J.↗

Star sensing for an earth imaging sensor

A star sensor includes (a) a scan mirror for scanning at least one star; (b) a detector array, coupled to the scan mirror, for detecting the one star; and (c) a processor, coupled to the detector array. The processor includes a first filter configured to reduce noise spikes in the detected one star, and provide a detection mask of filtered data. Also included is a second filter configured to reduce non-contiguous samples in the detection mask. A centroid calculator is included to determine a location of the one star, after the first and second filtering. The first filter includes a median filter, followed by an averaging filter, both configured to filter the one star in an along-scan direction of the scan mirror. The first filter includes another median filter, which is configured to filter the detected one star in the cross-scan direction of the scan mirror. An adder is included to subtract (a) output data from the other median filter from (b) output data from the averaging filter and provide filtered star data to the second filter.

Ellis, Kenneth K.↗

NASA Tech Briefs, January 2014

Topics include: Multi-Source Autonomous Response for Targeting and Monitoring of Volcanic Activity; Software Suite to Support In-Flight Characterization of Remote Sensing Systems; Visual Image Sensor Organ Replacement; Ultra-Wideband, Dual-Polarized, Beam-Steering P-Band Array Antenna; Centering a DDR Strobe in the Middle of a Data Packet; Using a Commercial Ethernet PHY Device in a Radiation Environment; Submerged AUV Charging Station; Habitat Demonstration Unit (HDU) Vertical Cylinder Habitat; Origami-Inspired Folding of Thick, Rigid Panels; A Novel Protocol for Decoating and Permeabilizing Bacterial Spores for Epifluorescent Microscopy; Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples; Enabling Microliquid Chromatography by Microbead Packing of Microchannels; On-Command Force and Torque Impeding Devices (OC-FTID) Using ERF; Deployable Fresnel Rings; Transition-Edge Hot-Electron Microbolometers for Millimeter and Submillimeter Astrophysics; Spacecraft Trajectory Analysis and Mission Planning Simulation (STAMPS) Software; Cross Support Transfer Service (CSTS) Framework Library; Arbitrary Shape Deformation in CFD Design; Range Safety Flight Elevation Limit Calculation Software; Frequency-Modulated, Continuous-Wave Laser Ranging Using Photon-Counting Detectors; Calculation of Operations Efficiency Factors for Mars Surface Missions; GPU Lossless Hyperspectral Data Compression System; Robust, Optimal Subsonic Airfoil Shapes; Protograph-Based Raptor-Like Codes; Fuzzy Neuron: Method and Hardware Realization; Kalman Filter Input Processor for Boresight Calibration; Organizing Compression of Hyperspectral Imagery to Allow Efficient Parallel Decompression; and Temperature Dependences of Mechanisms Responsible for the Water-Vapor Continuum Absorption.

Source record↗

A Highly Sensitive Multi-Element HgCdTe E-APD Detector for IPDA Lidar Applications

An HgCdTe electron avalanche photodiode (e-APD) detector has been developed for lidar receivers, one application of which is integrated path differential absorption lidar measurements of such atmospheric trace gases as CO2 and CH4. The HgCdTe APD has a wide, visible to mid-wave-infrared, spectral response, high dynamic range, substantially improved sensitivity, and an expected improvement in operational lifetime. A demonstration sensor-chip assembly consisting of a 4.3 lm cutoff HgCdTe 4 9 4 APD detector array with 80 micrometer pitch pixels and a custom complementary metal-oxide-semiconductor readout integrated circuit was developed. For one typical array the APD gain was 654 at 12 V with corresponding gain normalized dark currents ranging from 1.2 fA to 3.2 fA. The 4 9 4 detector system was characterized at 77 K with a 1.55 micrometer wavelength, 1 microsecond wide, laser pulse. The measured unit gain detector photon conversion efficiency was 91.1%. At 11 V bias the mean measured APD gain at 77 K was 307.8 with sigma/mean uniformity of 1.23%. The average, noise-bandwidth normalized, system noise-equivalent power (NEP) was 1.04 fW/Hz(exp 1/2) with a sigma/mean of 3.8%. The measured, electronics-limited, bandwidth of 6.8 MHz was more than adequate for 1 microsecond pulse detection. The system had an NEP (3 MHz) of 0.4 fW/Hz(exp 1/2) at 12 V APD bias and a linear dynamic range close to 1000. A gain-independent quantum-limited SNR of 80% of full theoretical was indicative of a gain-independent excess noise factor very close to 1.0 and the expected APD mode quantum efficiency.

NEP↗