Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Ground State Energy Functional with Hartree–Fock Efficiency and Chemical Accuracy

We introduce the deep post Hartree–Fock (DeePHF) method, a machine learning-based scheme for constructing accurate and transferable models for the ground-state energy of electronic structure problems. DeePHF predicts the energy difference between results of highly accurate models such as the coupled cluster method and low accuracy models such as the Hartree–Fock (HF) method, using the ground-state electronic orbitals as the input. It preserves all the symmetries of the original high accuracy model. The added computational cost is less than that of the reference HF or DFT and scales linearly with respect to system size. We examine the performance of DeePHF on organic molecular systems using publicly available data sets and obtain the state-of-art performance, particularly on large data sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ferroaxial density wave from intertwined charge and orbital order in rare-earth tritellurides

The discovery of the axial amplitude mode—commonly referred to as the Higgs mode—in charge density wave systems, such as rare-earth tritellurides, indicates the presence of a hidden order. A theoretical study proposed that this axial Higgs mode arises from a hidden orbital texture of the charge density wave, which produces a ferroaxial charge order. However, experimental evidence for the specific hidden order has been lacking. Here, we demonstrate a ferroaxial order of electronic origin throughout the rare-earth tritellurides. In ErTe 3 and HoTe 3 , which exhibit two distinct charge density waves with different ordering temperatures, a detailed investigation shows that the high-temperature charge order phase breaks translational, rotational and all vertical as well as diagonal mirror symmetries. Furthermore, this phase produces an axial Higgs mode and an axial electronic gap. By contrast, the low-temperature phase breaks only translational symmetry and gives rise to a scalar Higgs mode. Notably, both phases preserve the space inversion and time-reversal symmetries. These findings are consistent with a ferroaxial phase driven by coupled orbital and charge orders, highlighting the role of Higgs modes in revealing hidden orders in systems with intertwined charge density waves.

36 MATERIALS SCIENCE↗

In situ chemical probing of the electrode-electrolyte interface by ToF-SIMS

A portable vacuum interface allowing direct probing of the electrode-electrolyte interface was developed. A classical electrochemical system consisting of gold working electrode, platinum counter electrode, platinum reference electrode, and potassium iodide electrolyte was used to demonstrate real-time observation of the gold iodide adlayer on the electrode and chemical species as a result of redox reactions using cyclic voltammetry (CV) and the time-of-flight secondary ion mass spectrometry (ToF-SIMS, a vacuum-based surface analytical technique) simultaneously. This microfluidic electrochemical probe provides a new way to investigate the surface region with adsorbed molecules and region of diffused layer with chemical speciation in liquids in situ by surface sensitive techniques.

chemical imaging↗

Evaluation of the InSTEC's EDXRF assembly for Marine Sediment Pollution Studies

The determination of some heavy elements in marine sediments using the InSTEC's EDXRF assembly was evaluated. The spectrometer's main analytical characteristics were performed using {sup 109}Cd and {sup 238}Pu excitation sources. The system capabilities are tested by the analysis of the Certified Reference Material (CRM) IAEA-356. The results show that the K, Ca, Ti, Mn, Fe, Cu, Zn, Br, Rb, Zr and Pb elemental concentrations can be determined in marine sediments with an excellent accuracy and Co, Ni, Sr and Mo concentrations with an acceptable accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis, optical and electrochemical properties of Zn-porphyrin for dye sensitized solar cell applications

Zn-Porphyrin dye has been synthesized by the reaction between aldehydes and pyrrole. The dye structure was confirmed by {sup 1}H NMR, {sup 13}C NMR spectrum. The functional group of the dye molecule was confirmed by FTIR spectrum. The UV-Vis-NIR absorption spectrum of Zn-Porphyrin in DMF solution was recorded in spectrophotometer. The UV-Vis NIR spectrum of dye exhibits a strong Soret band and Q-band. Cyclic Voltammograms were obtained with three electrode systems: Pt as counter electrode, saturated calomel used as a reference electrode and glassy carbon as working electrode at a scan rate of 100 mV/s. The curves recorded the oxidation of 0.5 mM compound Zn-Porphyrin in a dichloromethane solution containing 0.1M TBAP as supporting electrolyte, reveal two successive quasi reversible redox couples with the first anodic and cathodic peak potentials of -0.2 V and -1 V. The second anodic and cathodic peak potentials are 0.82 V and 0.01 V respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Merging symmetry projection methods with coupled cluster theory: Lessons from the Lipkin model Hamiltonian

Coupled cluster and symmetry projected Hartree-Fock are two central paradigms in electronic structure theory. However, they are very different. Single reference coupled cluster is highly successful for treating weakly correlated systems but fails under strong correlation unless one sacrifices good quantum numbers and works with broken-symmetry wave functions, which is unphysical for finite systems. Symmetry projection is effective for the treatment of strong correlation at the mean-field level through multireference non-orthogonal configuration interaction wavefunctions, but unlike coupled cluster, it is neither size extensive nor ideal for treating dynamic correlation. We here examine different scenarios for merging these two dissimilar theories. We carry out this exercise over the integrable Lipkin model Hamiltonian, which despite its simplicity, encompasses non-trivial physics for degenerate systems and can be solved via diagonalization for a very large number of particles. We show how symmetry projection and coupled cluster doubles individually fail in different correlation limits, whereas models that merge these two theories are highly successful over the entire phase diagram. In conclusion, despite the simplicity of the Lipkin Hamiltonian, the lessons learned in this work will be useful for building an ab initio symmetry projected coupled cluster theory that we expect to be accurate in the weakly and strongly correlated limits, as well as the recoupling regime.

74 ATOMIC AND MOLECULAR PHYSICS↗

When do short-range atomistic machine-learning models fall short?

In this work, we explore the role of long-range interactions in atomistic machine-learning models by analyzing the effects on fitting accuracy, isolated cluster properties, and bulk thermodynamic properties. Such models have become increasingly popular in molecular simulations given their ability to learn highly complex and multi-dimensional interactions within a local environment; however, many of them fundamentally lack a description of explicit long-range interactions. In order to provide a well-defined benchmark system with precisely known pairwise interactions, we chose as the reference model a flexible version of the Extended Simple Point Charge (SPC/E) water model. Our analysis shows that while local representations are sufficient for predictions of the condensed liquid phase, the short-range nature of machine-learning models falls short in representing cluster and vapor phase properties. These findings provide an improved understanding of the role of long-range interactions in machine learning models and the regimes where they are necessary.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-throughput bend-strengths of ultra-small polysilicon MEMS components

The strength distribution of polysilicon bend specimens, approximately 10 μm in size, is measured using a high-throughput microelectromechanical system fabrication and testing method. The distribution is predicted from reference tests on tensile specimens and finite element analysis of the bend specimen geometry incorporated into a stochastic extreme-value strength framework. Agreement between experiment and prediction suggests that the ultra-small specimens may be at the limit of extreme-value scaling and contain only one strength-controlling flaw/specimen.

Cook, Robert F. (ORCID:0000000304228881)↗

Analysis of the effects of mismatched errors on coherent beam combining based on a self-imaging waveguide

A theoretical model of coherent beam combining (CBC) based on a self-imaging waveguide (SIW) is built and the effects of mismatched errors on SIW-based CBC are simulated and analysed numerically. With the combination of the theoretical model and the finite difference beam propagation method, two main categories of errors, assembly and nonassembly errors, are numerically studied to investigate their effect on the beam quality by using the M{sup 2} factor. The optimisation of the SIW and error control principle of the system is briefly discussed. The generalised methodology offers a good reference for investigating waveguide-based high-power coherent combining of fibre lasers in a comprehensive way. (lasers and laser beams)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A catalog of visually classified galaxies in the local (z ∼ 0.01) universe

The morphological types of 5836 galaxies were classified by a visual inspection of color images using the Sloan Digital Sky Survey Data Release 7 to produce a morphology catalog of a representative sample of local galaxies with z<0.01. The sample galaxies are almost complete for galaxies brighter than r{sub pet}=17.77. Our classification system is basically the same as that of the Third Reference Catalog of Bright Galaxies with some simplifications for giant galaxies. On the other hand, we distinguish the fine features of dwarf elliptical (dE)-like galaxies to classify five subtypes: dE, blue-cored dwarf ellipticals, dwarf spheroidals (dSph), blue dwarf ellipticals (dE{sub blue}), and dwarf lenticulars (dS0). In addition, we note the presence of nucleation in dE, dSph, and dS0. Elliptical galaxies and lenticular galaxies contribute only ∼1.5 and ∼4.9% of local galaxies, respectively, whereas spirals and irregulars contribute ∼32.1 and ∼42.8%, respectively. The dE{sub blue} galaxies, which are a recently discovered population of galaxies, contribute a significant fraction of dwarf galaxies. There seem to be structural differences between dSph and dE galaxies. The dSph galaxies are fainter and bluer with a shallower surface brightness gradient than dE galaxies. They also have a lower fraction of galaxies with small axis ratios (b/a≲0.4) than dE galaxies. The mean projected distance to the nearest neighbor galaxy is ∼260 kpc. About 1% of local galaxies have no neighbors with comparable luminosity within a projected distance of 2 Mpc.

79 ASTRONOMY AND ASTROPHYSICS↗

Spin Rotation Technique for Non-Collinear Magnetic Systems: Application to the Generalized Villain Model

This work develops a new generalized technique for determining the static and dynamic properties of any non-collinear magnetic system. By rotating the spin operators into the local spin reference frame, we evaluate the zeroth, first, and second order terms in a Holstein-Primakoff expansion, and through a Green s functions approach, we determine the structure factor intensities for the spin-wave frequencies. To demonstrate this technique, we examine the spin-wave dynamics of the generalized Villain model with a varying interchain interaction. The new interchain coupling expands the overall phase diagram with the realization of two non-equivalent canted spin configurations. The rotational Holstein-Primakoff expansion provides both analytical and numerical results for the spin dynamics and intensities of these phases.

Haraldsen, Jason T↗

Unified analytical description of the time evolution of decay for initial states formed by wave-packet scattering and by initial decaying states in quantum systems

We consider a unified analytical approach for scattering and decay processes in one-dimensional resonant tunneling systems using the formalism of resonant states to address the issue of the differences and similarities in the time evolution of decay between the decay of an arbitrary state prepared initially within a system and the formation and subsequent decay of a quasistationary state in the scattering of a Gaussian wavepacket on that system. We find three distinctive regimes. A first regime, which refers only to the quasistationary state, that is characterized by a buildup time of the probability density at a given position within the internal region of the potential. Here we find that the buildup time has a dependence on position. A second regime, dominated by the exponentially decaying terms, where the decay of the quasistationary state proceeds in an almost identical fashion as for the initially prepared decaying state. And finally, a third regime that involves the transition to nonexponential decay at long times and its ulterior behavior as an inverse power of time. Here we find that the time scale of the transition occurs at different times, which implies a dependence on the parameters of the initial state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unitarity potentials and neutron matter at the unitary limit

We study the equation of state of neutron matter using a family of unitarity potentials, all of which are constructed to have infinite {sup 1}S{sub 0} scattering lengths a{sub s}. For such a system, a quantity of much interest is the ratio xi=E{sub 0}/E{sub 0}{sup free}, where E{sub 0} is the true ground-state energy of the system and E{sub 0}{sup free} is that for the noninteracting system. In the limit of a{sub s}->+-{infinity}, often referred to as the unitary limit, this ratio is expected to approach a universal constant, namely {xi}{approx}0.44(1). In the present work we calculate this ratio {xi} using a family of hard-core square-well potentials whose a{sub s} can be exactly obtained, thus enabling us to have many potentials of different ranges and strengths, all with infinite a{sub s}. We have also calculated {xi} using a unitarity CDBonn potential obtained by slightly scaling its meson parameters. The ratios {xi} given by these different unitarity potentials are all close to each other and also remarkably close to 0.44, suggesting that the above ratio {xi} is indifferent to the details of the underlying interactions as long as they have infinite scattering length. A sum-rule and scaling constraint for the renormalized low-momentum interaction in neutron matter at the unitary limit is studied. The importance of pairing in our all-order ring diagram and model-space HF calculations of neutron matter is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Filtered Multi-Tone Spread Spectrum With Overlapping Subbands

A new form of the filter bank multi-carrier spread spectrum (FBMC-SS) waveform is presented. This new waveform modifies the filtered multi-tone spread spectrum (FMT-SS) system, and is intended to whiten the power spectral density (PSD) of the transmit signal. In the conventional FMT-SS, subcarrier bands are non-overlapping, leaving a spectral null between the adjacent subcarrier bands. To make FMT-SS more appealing for a broader set of applications than those studied in the past, we propose adding additional subcarriers centered at these nulls and thoroughly explore the impact of the added subcarriers on the system performance. This modified form of FMT-SS is referred to as overlapped FMT-SS (OFMT-SS). We explore the conditions required for maximally flattening the PSD of the synthesized OFMT-SS signal and for cancelling the interference caused by overlapping subbands. We also explore the choices of spreading gains that result in a low peak-to-average power ratio (PAPR) for a number of different scenarios. Further reduction of the PAPR of the synthesized signal through clipping methods is also explored. Additionally, we propose methods of multi-coding for increasing the data rate of the OFMT-SS waveform, while minimally impacting its PAPR.

42 - ENGINEERING↗

Efficient Interdependent Systems Recovery Modeling with DeepONets

Modeling the recovery of interdependent critical infrastructure is a key component of quantifying and optimizing societal resilience to disruptive events. However, simulating the recovery of large-scale interdependent systems under random disruptive events is computationally expensive. Therefore, we propose the application of Deep Operator Networks (DeepONets) in this paper to accelerate the recovery modeling of interdependent systems. DeepONets are ML architectures which identify mathematical operators from data. The form of governing equations DeepONets identify and the governing equation of interdependent systems recovery model are similar. Therefore, we hypothesize that DeepONets can efficiently model the interdependent systems recovery with little training data. We applied DeepONets to a simple case of four interdependent systems with sixteen states. DeepONets, overall, performed satisfactorily in predicting the recovery of these interdependent systems for out of training sample data when compared to reference results.

97 MATHEMATICS AND COMPUTING↗

SIMS Bias on Isotope Ratios in Ca-Mg-Fe Carbonates (Part III): δ 18 O and δ 13 C Matrix Effects Along the Magnesite-Siderite Solid-Solution Series

This study explores the effects of cation composition on mass bias (i.e., the matrix effect), which is a major component of instrumental mass fractionation (IMF) in the microanalyses of δ 13 C and δ 18 O by SIMS in carbonates of the magnesite–siderite solid-solution series (MgCO 3 –FeCO 3 ). A suite of twelve calibration reference materials (RMs) was developed and documented (calibrated range: Fe# = 0.002–0.997, where Fe# = molar Fe/[Mg + Fe]), along with empirical expressions for regressing calibration data (affording residuals < 0.5‰ relative to certified reference material NIST-19). The calibration curves of both isotope systems are non-linear and have, over a 2-year period, fallen into one of two distinct but largely self-consistent shape categories (data from ten measurement sessions), despite adherence to well-established analytical protocols for carbonate δ 13 C and δ 18 O analyses at WiscSIMS (CAMECA IMS 1280). Mass bias was consistently most sensitive to changes in composition near the magnesite end-member (Fe# 0–0.2), deviating by up to 4.5‰ (δ 13 C) and 14‰ (δ 18 O) with increasing Fe content. The cause of variability in calibration curve shapes is not well understood at present and demonstrates the importance of having available a sufficient number of well-characterised RMs so that potential complexities of curvature can be adequately delineated and accounted for on a session-by-session basis.

58 GEOSCIENCES↗

Commissioning and dosimetric characteristics of TrueBeam system: Composite data of three TrueBeam machines

Purpose: A TrueBeam linear accelerator (TB-LINAC) is designed to deliver traditionally flattened and flattening-filter-free (FFF) beams. Although it has been widely adopted in many clinics for patient treatment, limited information is available related to commissioning of this type of machine. In this work, commissioning data of three units were measured, and multiunit comparison was presented to provide valuable insights and reliable evaluations on the characteristics of the new treatment system. Methods: The TB-LINAC is equipped with newly designed waveguide, carousel assembly, monitoring control, and integrated imaging systems. Each machine in this study has 4, 6, 8, 10, 15 MV flattened photon beams, and 6 MV and 10 MV FFF photon beams as well as 6, 9, 12, 16, 20, and 22 MeV electron beams. Dosimetric characteristics of the three new TB-LINAC treatment units are systematically measured for commissioning. High-resolution diode detectors and ion chambers were used to measure dosimetric data for a range of field sizes from 10 Multiplication-Sign 10 to 400 Multiplication-Sign 400 mm{sup 2}. The composite dosimetric data of the three units are presented in this work. The commissioning of intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), image-guided radiation therapy, and gating systems are also illustrated. Critical considerations of P{sub ion} of FFF photon beams and small field dosimetric measurements were investigated. Results: The authors found all PDDs and profiles matched well among the three machines. Beam data were quantitatively compared and combined through average to yield composite beam data. The discrepancies among the machines were quantified using standard deviation (SD). The mean SD of the PDDs among the three units is 0.12%, and the mean SD of the profiles is 0.40% for 10 MV FFF open fields. The variations of P{sub ion} of the chamber CC13 is 1.2 {+-} 0.1% under 6 MV FFF and 2.0 {+-} 0.5% under 10 MV FFF from dmax to the 18 cm-off-axis point at 35 cm depth under 40 Multiplication-Sign 40 cm{sup 2}. The mean penumbra of crossplane flattened photon beams at collimator angle of 0 Degree-Sign is measured from 5.88 {+-} 0.09 to 5.99 {+-} 0.13 mm from 4 to 15 MV at 10 cm depth of 100 Multiplication-Sign 100 mm{sup 2}. The mean penumbra of crossplane beams at collimator angle of 0 Degree-Sign is measured as 3.70 {+-} 0.21 and 4.83 {+-} 0.04 mm for 6 MV FFF and 10 MV FFF, respectively, at 10 cm depth with a field size of 5 Multiplication-Sign 5 cm{sup 2}. The end-to-end test procedures of both IMRT and VMAT were performed for various energy modes. The mean ion chamber measurements of three units showed less than 2% between measurement and calculation; the mean MultiCube ICA measurements demonstrated over 90% pixels passing gamma analysis (3%, 3 mm, 5% threshold). The imaging dosimetric data of KV planar imaging and CBCT demonstrated improved consistency with vendor specifications and dose reduction for certain imaging protocols. The gated output verification showed a discrepancy of 0.05% or less between gating radiation delivery and nongating radiation delivery. Conclusions: The commissioning data indicated good consistency among the three TB-LINAC units. The commissioning data provided us valuable insights and reliable evaluations on the characteristics of the new treatment system. The systematically measured data might be useful for future reference.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-428: Dosimetric Impact of Multileaf Collimator Leaf Width On Single and multiple Isocenter Stereotactic IMRT Treatment Plans for multiple Brain Tumors

Purpose: To assess the impacts that multileaf collimator (MLC) leaf width has on the dose conformity and normal brain tissue doses of single and multiple isocenter stereotactic IMRT (SRT) plans for multiple intracranial tumors. Methods: Fourteen patients with 2–3 targets were studied retrospectively. Patients treated with multiple isocenter treatment plans using 9 to 12 non-coplanar beams per lesion underwent repeat planning using single isocenter and 10 to 12 non-coplanar beams with 2.5mm, 3mm and 5mm MLC leaf widths. Brainlab iPlan treatment planning system for delivery with the 2.5mm MLC served as reference. Identical contour sets and dose-volume constraints were applied. The prescribed dose to each target was 25 Gy to be delivered over 5 fractions with a minimum of 99% dose to cover ≥ 95% of the target volume. Results: The lesions and normal brains ranged in size from 0.11 to 51.67cc (median, 2.75cc) and 1090 to 1641cc (median, 1401cc), respectively. The Paddick conformity index for single and multiple isocenter (2.5mm vs. 3mm and 5mm MLCs) was (0.79±0.08 vs. 0.79±0.07 and 0.77±0.08) and (0.79±0.09 vs. 0.77±0.09 and 0.76±0.08), respectively. The average normal brain volumes receiving 15 Gy for single and multiple isocenter (2.5mm vs. 3mm and 5mm MLCs) were (3.65% vs. 3.95% and 4.09%) and (2.89% vs. 2.91% and 2.92%), respectively. Conclusion: The average dose conformity observed for the different leaf width for single and multiple isocenter plans were similar, throughout. However, the average normal brain volumes receiving 2.5 to 15 Gy were consistently lower for the 2.5mm MLC leaf width, especially for single isocenter plans. The clinical consequences of these integral normal brain tissue doses are still unknown, but employing the use of the 2.5mm MLC option is desirable at sparing normal brain tissue for both single and multiple isocenter cases.

60 APPLIED LIFE SCIENCES↗