Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

NEAT: A Microarcsec Astrometric Telescope

NEAT, Nearby Exo-Earth Astrometric Telescope is a medium-small telescope (is) approximately 1m in diameter that is designed to make ultra precise (is) less than 1 uas (microarcsec) astrometric measurements of nearby stars in a (is) approximately 1hr observation. Four major error sources prevent normal space telescopes from obtaining accuracies close to 1 uas. Even with a small 1m telescope, photon noise is usually not a problem for the bright nearby target stars. But in general, the reference stars are much fainter. Typically a field of view of (is) approximately 0.5 deg dia is needed to obtain enough bright reference stars. The NEAT concept uses a very simple but unusual design to avoid optically induced astrometric errors. The third source of error is the accuracy and stability of the focal plane. A 1uas error over a (is) approximately 2000 arcsec field of view implies the focal plane is accurate or at least stable to 5 parts in 10(exp 10) over the lifetime of the mission ( (is) approximately 5yrs). The 4th class of error has to do with our knowledge of the PSF and how that PSF is sampled by an imperfect detector. A Nyquist sampled focal plane would have (is) greater than 2 pixels per lambda/D, and centroiding to 1uas means centroiding to 10-5 pixels. This paper describes the mission concept, and an overview of the technology needed to perform 1uas astrometry with a small telescope, and how we overcome problems 1 and 2. A companion paper will describe the technical progress we've made in solving problems 3 and 4.

Earth like planets↗

Long-Term Evaluation of Landsat 9 Oli Data Product Uniformity at Focal Plane Module-Boundaries Using Earth Scenes

The uniformity performance characteristic in remote sensing data products is a metric that helps evaluate how an image accurately represents radiometric responses to geophysical variability at the Earth’s surface or within the atmosphere. These uniformity attributes are used in Earth remote sensing science applications such as investigating water quality, land-cover/land-use classifications, and crop health assessments. To ensure these applications perform effectively, it is crucial to maintain and regularly assess the uniformity of calibrated remote sensing data products. In the Landsat missions, data from the onboard radiometric reference Solar diffuser device are used as the standard approach to derive the calibration parameters, ensuring the maintenance of both absolute radiance and radiometric uniformity through quarterly updates. This publication presents an alternative approach that leverages Earth scene data to assess the on-orbit uniformity performance of the Landsat 9 (L9) mission. The analysis characterizes uniformity at a specific set of spatial positions (the focal-plane boundary zones) that are intrinsic to the Operational Land Imager (OLI) focal plane design. By employing these Earth data statistics, the article further explores the temporal trends in the radiometric uniformity results. The results shown in this article demonstrate that for pushbroom imaging design systems with staggered sensor chip focal plane architectures, the co-registered pixels, i.e., overlapping measurements of the same ground target viewed by different detectors, offer a self-contained mechanism for assessing product uniformity. Remarkably, this alternative approach achieves a level of radiometric quality comparable to that delivered by a stable, well-characterized onboard Solar diffuser calibration device. The findings demonstrate the potential and capability of such Earth scene statistics in maintaining radiometric uniformity in calibrated data products to better than 1% (1-sigma) throughout the mission’s operational lifetime.

trend↗

Silicon vertex tracker for RHIC PHENIX Experiment

The PHENIX experiment at Relativistic Heavy Ion Collider will be equipped with Silicon Vertex tracker to enhance its physics capability. There are four layers of silicon sensor to reconstruct charged tracks with 50 {micro}m resolution of decay length measurement. The VTX surrounds the collision point. The inner two layers and the outer two layers are composed of 30 pixel ladders and 44 stripixel ladders, respectively. We have been developing these detectors and done a performance test with 120 GeV proton beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Silicon vertex tracker for RHIC PHENIX experiment

The PHENIX experiment at Relativistic Heavy Ion Collider will be equipped with Silicon Vertex tracker to enhance its physics capability. There are four layers of silicon sensor to reconstruct charged tracks with 50 {micro}m resolution of decay length measurement. The VTX surrounds the collision point. The inner two layers and the outer two layers are composed of 30 pixel ladders and 44 stripixel ladders, respectively. We have been developing these detectors and done a performance test with 120 GeV proton beam.

74 ATOMIC AND MOLECULAR PHYSICS↗

Machine Learning for DUNE Supernova Trigger

One of the major scientific goals of the Deep Underground Neutrino Experiment (DUNE) is to detect and measure the neutrino flux originating from galactic core-collapse supernovae. These neutrinos provide an opportunity to study the end of life evolution of massive stars, and reveal information about the structure of core-collapse that is not visible in observations of the electromagnetic spectrum. Because of the rarity of these events, it is crucial that DUNE is able to detect supernova neutrino interactions when they occur. However, this will require sifting through a large quantity of data, motivating the development of a trigger algorithm to identify significant events and discard irrelevant data. Machine learning provides a potential approach to building this trigger. This project generates ADC and ground truth images of simulated neutrino interactions in a LArTPC detector to be used for machine learning, and uses them to train a sparse Convolutional Neural Network (C NN). The performance of this model when applied to the task of pixel classification based on interaction type is examined. This project found that the sparse CNN approach has the potential to have high accuracy in pixel classification, meaning it may be highly relevant to the development of a supernova neutrino trigger for the DUNE far detector.

Damish, S.↗

Centroid Position as a Function of Total Counts in a Windowed CMOS Image of a Point Source

We obtained 960,200 22-by-22-pixel windowed images of a pinhole spot using the Teledyne H2RG CMOS detector with un-cooled SIDECAR readout. We performed an analysis to determine the precision we might expect in the position error signals to a telescope's guider system. We find that, under non-optimized operating conditions, the error in the computed centroid is strongly dependent on the total counts in the point image only below a certain threshold, approximately 50,000 photo-electrons. The LSST guider camera specification currently requires a 0.04 arcsecond error at 10 Hertz. Given the performance measured here, this specification can be delivered with a single star at 14th to 18th magnitude, depending on the passband.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron Fluence and Energy Reconstruction with the LNE-IRSN/MIMAC Recoil Detector MicroTPC at 27 keV

The French Institute for Radiation protection and Nuclear Safety (IRSN), designated by the French Metrology Institute (LNE) for neutron metrology, is developing a time projection chamber using a Micromegas anode: microTPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize the energy distribution of neutron fluence in the energy range 8 keV - 5 MeV with a primary procedure. The time projection chambers are gaseous detectors able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulation of the detector response. The μTPC is a new reliable detector able to measure energy distribution of the neutron fluence without unfolding procedure or prior neutron calibration contrary to usual gaseous counters. The microTPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27 keV and 144 keV are shown and compared to the complete detector response simulation. This work shows the first direct reconstruction of neutron energy and fluence, simultaneously, at 27.2 keV in a continuous irradiation mode. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards Dualband Megapixel QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024 x 1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NEDT) of 17 mK at a 95 K operating temperature with f/2.5 optics at 300 K background and the LWIR detector array has demonstrated a NEDT of 13 mK at a 70 K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90 K and 70 K operating temperatures respectively, with similar optical and background conditions. In addition, we have demonstrated MWIR and LWIR pixel co-registered simultaneously readable dualband QWIP focal plane arrays. In this paper, we will discuss the performance in terms of quantum efficiency, NEDT, uniformity, operability, and modulation transfer functions of the 1024 x 1024 pixel arrays and the progress of dualband QWIP focal plane array development work.

Infrared detectors↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

Initial On-Orbit Spatial Resolution Characterization of OrbView-3 Panchromatic Images

Characterization was conducted under the Memorandum of Understanding among Orbital Sciences Corp., ORBIMAGE, Inc., and NASA Applied Sciences Directorate. Acquired five OrbView-3 panchromatic images of the permanent Stennis Space Center edge targets painted on a concrete surface. Each image is available at two processing levels: Georaw and Basic. Georaw is an intermediate image in which individual pixels are aligned by a nominal shift in the along-scan direction to adjust for the staggered layout of the panchromatic detectors along the focal plane array. Georaw images are engineering data and are not delivered to customers. The Basic product includes a cubic interpolation to align the pixels better along the focal plane and to correct for sensor artifacts, such as smile and attitude smoothing. This product retains satellite geometry - no rectification is performed. Processing of the characterized images did not include image sharpening, which is applied by default to OrbView-3 image products delivered by ORBIMAGE to customers. Edge responses were extracted from images of tilted edges in two directions: along-scan and cross-scan. Each edge response was approximated with a superposition of three sigmoidal functions through a nonlinear least-squares curve-fitting. Line Spread Functions (LSF) were derived by differentiation of the analytical approximation. Modulation Transfer Functions (MTF) were obtained after applying the discrete Fourier transform to the LSF.

Blonski, Slawomir↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial assessment of multilayer silicon detectors for hard X-ray imaging

Silicon detectors with lower material budget, ultrafast readout and radiation hardness are under developments. These unique features make pixelized silicon sensors a good option for hard X-ray imaging. To verify the performance of spatial resolution and energy sensitivity of silicon sensors to hard X-rays, a two layer setup of Pixelink PL-D725MU sensors has been tested at the Argonne National Laboratory Advanced Photon Source (APS) ID-10 sector with 29.2 keV high photon flux (4.5 x 10(8) to 4.5 x 10(10) photons per second) X-rays. Better than 3 mu m spatial resolution and clear energy characterization have been achieved by both layers. Commercial CMOS sensors with superior spatial resolution could be used for phase contrast imaging in current synchrotrons. These studies pave the path for future multilayer ultrafast silicon sensor development with ns to sub-ns readout speeds in hard X-ray imaging at synchrotrons and XFEL beamlines.

Hard X-ray imaging↗

Constraints on Light Dark Matter Particles Interacting with Electrons from DAMIC at SNOLAB

We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2–6×10-22 A cm^-2. We evaluate the charge distribution of pixels that collect < 10 e- for contributions beyond the leakage current that may be attributed to dark matter interactions. Constraints are placed on so-far unexplored parameter space for dark matter masses between 0.6 and 100 MeV c^-2. We also present new constraints on hidden-photon dark matter with masses in the range 1.2–30 eV c^-2.

Dark Matter, DAMIC, SNOLAB↗

1024x1024 Pixel MWIR and LWIR QWIP Focal Plane Arrays and 320x256 MWIR:LWIR Pixel Colocated Simultaneous Dualband QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024x1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NE(Delta)T) of 17 mK at a 95K operating temperature with f/2.5 optics at 300K background and the LWIR detector array has demonstrated a NE(Delta)T of 13 mK at a 70K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90K and 70K operating-temperatures respectively, with similar optical and background conditions. In addition, we are in the process of developing MWIR and LWIR pixel collocated simultaneously readable dualband QWIP focal plane arrays.

quantum wells↗

The LiteBIRD Satellite Mission: Sub-Kelvin Instrument

Inflation is the leading theory of the first instant of the universe. Inflation, which postulates that the universe underwent a period of rapid expansion an instant after its birth, provides convincing explanation for cosmological observations. Recent advancements in detector technology have opened opportunities to explore primordial gravitational waves generated by the inflation through “B-mode” (divergent-free) polarization pattern embedded in the cosmic microwave background anisotropies. If detected, these signals would provide strong evidence for inflation, point to the correct model for inflation, and open a window to physics at ultra-high energies. LiteBIRD is a satellite mission with a goal of detecting degree-and-larger-angular-scale B-mode polarization. LiteBIRD will observe at the second Lagrange point with a 400 mm diameter telescope and 2622 detectors. It will survey the entire sky with 15 frequency bands from 40 to 400 GHz to measure and subtract foregrounds. The US LiteBIRD team is proposing to deliver sub-Kelvin instruments that include detectors and readout electronics. A lenslet-coupled sinuous antenna array will cover low-frequency bands (40–235 GHz) with four frequency arrangements of trichroic pixels. An orthomode-transducer-coupled corrugated horn array will cover high-frequency bands (280–402 GHz) with three types of single frequency detectors. The detectors will be made with transition edge sensor (TES) bolometers cooled to a 100 milli-Kelvin base temperature by an adiabatic demagnetization refrigerator. The TES bolometers will be read out using digital frequency multiplexing with Superconducting QUantum Interference Device (SQUID) amplifiers. Up to 78 bolometers will be multiplexed with a single SQUID amplifier. Lastly, we report on the sub-Kelvin instrument design and ongoing developments for the LiteBIRD mission.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EFFECT OF VARIOUS DETECTOR GEOMETRIES ON THE PERFORMANCE OF CZT USING ONE CRYSTAL

CdZnTe (CZT) continues to be a major thrust interest mainly due to its potential application as a room temperature radiation detector. The performance of CZT detectors is directly related to the charge collection ability which can be affected by the configuration of the electrical contact. The charge collection efficiency is determined in part by the specific geometry of the anode contact which serves as the readout electrode. In this report, contact geometries including single pixel, planar, coplanar, and dual anode will be systematically explored by comparing the performance efficiencies of the detector using both low and high energy gamma rays. To help eliminate the effect of crystal quality variations, the contact geometries were fabricated on the same crystal detector with minimal polishing between contact placements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gallium arsenide quantum well-based far infrared array radiometric imager

We have built an array-based camera (FIRARI) for thermal imaging (lambda = 8 to 12 microns). FIRARI uses a square format 128 by 128 element array of aluminum gallium arsenide quantum well detectors that are indium bump bonded to a high capacity silicon multiplexer. The quantum well detectors offer good responsivity along with high response and noise uniformity, resulting in excellent thermal images without compensation for variation in pixel response. A noise equivalent temperature difference of 0.02 K at a scene temperature of 290 K was achieved with the array operating at 60 K. FIRARI demonstrated that AlGaAS quantum well detector technology can provide large format arrays with performance superior to mercury cadmium telluride at far less cost.

Forrest, Kathrine A.↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗