In-Rod Sensor System Overview, Benefits and Recent Irradiation Test Results

Westinghouse is developing an In-Rod Sensor (IRS) System capable of measuring critical fuel rod parameters such as center-line fuel temperature, rod internal pressure and axial fuel pellet stack elongation without having penetrations to the fuel rod. The technology is similar to the Halden Reactor instrumentation, but the IRS system focuses on commercial fuel rod instrumentation. Both systems circumvent fuel rod penetrations, however the IRS system overcomes unique geometric challenges found in commercial fuel rod assemblies. The IRS could also play a key role in accelerated fuel qualification by allowing real-time measurements during separate effects tests, integral fuel testing or during irradiation of lead test rods or lead test assemblies. Combining these measurements with data acquired from targeted separate effects testing and multi-scale modelling could significantly reduce the time required to qualify new fuel and reduce the safety margin uncertainty of operating plants. The IRS is actively in development for Light Water Reactors (LWR) based fuel assemblies but can also be applied to Gen IV reactor designs with minimal modifications.

Carvajal, Jorge↗

Increased range and contrast in fog with circularly polarized imaging

Fogs, low lying clouds, and other highly scattering environments pose a challenge for many commercial and national security sensing systems. Current autonomous systems rely on optical sensors for navigation whose performance is degraded by highly scattering environments. In our previous simulation work, we have shown that polarized light can penetrate through a scattering environment such as fog. We have demonstrated that circularly polarized light maintains its initial polarization state better than linearly polarized light, even through large numbers of scattering events and thus ranges. This has recently been experimentally verified by other researchers. In this work, we present the design, construction, and testing of active polarization imagers at short-wave infrared and visible wavelengths. We explore multiple polarimetric configurations for the imagers, focusing on linear and circular polarization states. The polarized imagers were tested at the Sandia National Laboratories Fog Chamber under realistic fog conditions. Here, we show that active circular polarization imagers can increase range and contrast in fog better than linear polarization imagers. We show that when imaging typical road sign and safety retro-reflective films, circularly polarized imaging has enhanced contrast throughout most fog densities/ranges compared to linearly polarized imaging and can penetrate over 15 to 25 m into the fog beyond the range limit of linearly polarized imaging, with a strong dependence on the interaction of the polarization state with the target materials.

47 OTHER INSTRUMENTATION↗

Determination of Ground Subsidence Around Snow Fences in the Arctic Region

In this study, we analyzed the effects of snow cover changes caused by snow fences (SFs) installed in 2017 in the Alaskan tundra to examine ground subsidence. Digital surface model data obtained through LiDAR-based remote sensing in 2019 and 2022, combined with a field survey in 2021, revealed approximately 0.2 m of ground subsidence around the SF. To investigate the relationship between SF-induced snow cover changes and ground subsidence, geophysical methods, electrical resistivity tomography (ERT) and ground-penetrating radar (GPR), were applied in 2023 to analyze subsurface characteristics. The increased snow cover due to the SF-enhanced insulation, delaying the penetration of winter cold into the subsurface. This delay caused subsurface temperatures to decrease more slowly, melting the upper permafrost and increasing the thickness of the active layer. ERT and GPR surveys well delineated the boundary between the active layer and permafrost, confirming that the increased snow cover thickened the active layer. This thickening led to the melting of pore ice, causing water runoff and ground compaction, which resulted in subsidence. The runoff also formed channels flowing eastward over the SF. This study highlights how changes in snow cover can influence active layer properties, leading to localized environmental changes and ground subsidence.

54 ENVIRONMENTAL SCIENCES↗

Single-gap isotropic s- wave superconductivity in single crystals AuSn 4

In this article, London, λ L (T), and Campbell, λ C (T), penetration depths were measured in single crystals of a topological superconductor candidate AuSn 4 . At low temperatures, λ L (T) is exponentially attenuated and, if fitted with the power law, λ(T) ~ T n , gives exponents n > 4, indistinguishable from the isotropic single s- wave gap Bardeen-Cooper-Schrieffer (BCS) asymptotic. The superfluid density fits perfectly in the entire temperature range to the BCS theory. The superconducting transition temperature, T c = 2.40 ± 0.05 K, does not change after 2.5 MeV electron irradiation, indicating the validity of the Anderson theorem for isotropic s- wave superconductors. Campbell penetration depth before and after electron irradiation shows no hysteresis between the zero-field cooling (ZFC) and field cooling (FC) protocols, consistent with the parabolic pinning potential. Interestingly, the critical current density estimated from the original Campbell theory decreases after irradiation, implying that a more sophisticated theory involving collective effects is needed to describe vortex pinning in this system. In general, our thermodynamic measurements strongly suggest that the bulk response of the AuSn 4 crystals is fully consistent with the isotropic s- wave weak-coupling BCS superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of Generation of Higher-Order Neutron Scattering Cross Sections

The generation of high-order neutron scattering cross sections consistent with high-fidelity simulations remains an area of active research. Popular options include generating cross sections from continuous energy Monte Carlo calculations or generating cross sections from a deterministic neutron transport calculation with high-fidelity tabulated cross sections. Both options present challenges. Monte Carlo simulations can naturally process continuous energy cross section data and allow for the general description of anisotropic neutron scattering given a scattering law. However, Monte Carlo simulations are inherently related to particle weighting and it has been suggested that this may be unacceptable for generating high-order neutron scattering cross sections. Deterministic neutron transport calculations can easily calculate high-order moments of the flux to appropriately calculate higher-order neutron scattering cross sections but are generally limited by discretization of space, energy, and angle. In this work, the trade-offs between generation of high-order neutron scattering cross sections via Monte Carlo and deterministic neutron transport methods are investigated. The methods implemented in the Monte Carlo computer program Serpent and the deterministic fast reactor neutron cross section generator MC2-3 are compared. Cross sections resulting from these methods are used in Rattlesnake, a deterministic neutron transport code developed by Idaho National Laboratory (INL), and results are compared to a reference continuous energy Monte Carlo calculation. Whereas previous work investigating the effects of anisotropic neutron scattering has focused on light water reactor (LWR) simulations, this work focuses on high-order neutron scattering cross sections as they relate to fast reactor simulations. To investigate the consequences of the Serpent and MC2-3 methodologies, a test problem is developed. The test problem is a one-dimensional geometry with fast reactor materials designed to demonstrate deep penetration and exacerbate the effects of high-order neutron scattering. Based on the results of the deep penetration test problem, it is concluded that P3 neutron scattering cross sections are sufficient to describe anisotropic scattering in fast reactor materials. Any neutron scattering of order higher than P3 offers negligible change in the eigenvalue of the test problem. Additionally, it is determined that the methodology as implemented in Serpent is applicable for generating high-order neutron scattering cross sections through at least P3 in fast reactor materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand Response in Bangalore: Implications for Electricity System Operations

Recent Greening the Grid studies for India highlight the benefits of flexible resources for integrating variable renewable energy onto India’s electricity system. India’s ambitious renewable energy targets, which are particularly focused on renewable resource states such as Karnataka, will face fewer challenges when combined with new planning and operational strategies and technologies. This report explores one such strategy - demand response - by which the system operator shifts load throughout a day to minimize system wide production costs. To explore this strategy, we added demand response resources to Karnataka’s electricity system in a production cost model of India, using load shifting potential analyzed by Lawrence Berkeley National Labs. We then investigated the impacts of increasing demand response capacity under several renewable resource scenarios. Our results show the addition of demand response enables fuel shifting from high-marginal-cost and emissions-intensive subcritical coal and diesel generation to zero-marginal-cost and emissions-free renewable generation. Accordingly, the value that demand response provides to the system increases as the renewable penetration increases. In addition to reducing production costs and emissions, demand response reduces the time that thermal generators spend at their minimum output levels, which typically represents a less efficient and costlier operational state. Agricultural load shifting provides greater value to the system than residential, commercial, or industrial loads. Agricultural demand response is more flexible than other sectors because it is not exposed to subdaily operational constraints and it can operate for more hours per day without impacting customer satisfaction. Further, the first increment of demand response that is added to a system provides the greatest value; further additions provide additional benefits but have a decreasing impact. The insights we discuss could be leveraged by system planners and operators in other jurisdictions, particularly those facing significant renewable energy penetrations, to develop their own demand response programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Counterflow Virtual Impactor (CVI) Inlet Aboard Aircraft (INLETCVI-AIR) Instrument Handbook

The counterflow virtual impactor (CVI) inlet separates out and samples cloud elements via inertial impaction. Warm, dry, particle-free carrier gas of known composition is pumped to the tip of the inlet in the direction opposite of the flow of air. The flow lines of the incoming free stream air are split. Larger droplets and ice crystals suspended in the sample air have enough inertia to penetrate the counterflow and enter the sample flow, while smaller, unactivated particles follow the streamlines of the air flowing around the inlet’s tip (Noone et al. 1988). The instrument is capable of sampling cloud elements as a function of cut size by changing the velocity of counterflow at the probe tip. The CVI cut size is usually defined as a diameter of a smallest particle for which penetration rate is 50%. For the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facilityGulfstream-159 aircraft’s CVI inlet, that value is usually around 13 microns. The dry heated air, normally used as the carrier gas, also serves to evaporate water from the hydrometeor, leaving the residuals to be sampled by in-cabin aerosol instrumentation. The number concentration of the droplet residue in the CVI sample line is usually increased with respect to corresponding cloud element number concentration. The CVI performance as a concentrator is usually described via CVI enhancement factor, which is a conversion factor between ambient volumetric concentration (not adjusted to standard temperature and pressure) and volumetric concentration in the CVI sample line.

54 ENVIRONMENTAL SCIENCES↗

Accobeam - Acoustic Collimated Beam

Researchers at Los Alamos have developed a collimated acoustic imaging technology for non-destructive characterization of highly attenuating media, such as concrete, rocks, mud, and metal casings. The technology is used to investigate structural defects that could compromise important assets such as well boreholes, building structures and sensitive materials like explosives. Current acoustic methods are often unable to penetrate such materials deeply for more informative analysis, which limits what can be learned about asset structural integrity, crucial information companies require to make investment decisions such as fixing or replacing structures well before assets are completely compromised. ACCObeam provides requisite penetration and high-resolution acoustic imaging with applications in borehole imaging, explosives threat evaluation, and structural health evaluation. This technology will potentially save companies significant money by producing accurate and useful visual analyses to better understand the actual condition of assets in the field and respond accordingly. Los Alamos is searching for a collaboration partner to develop this technology for commercial applications that will lead to licensing opportunities for broad industry deployment.

36 MATERIALS SCIENCE↗

RingIR AG-4000 Testing

The AG-4000 detector can identify gas phase species using molecular fingerprinting and has potential application for SARS-CoV-2 detection in near real time. As part of the development process Sandia will utilize the biological aerosol test bed deployed at the Aerosol Complex to evaluate the penetration of MS2 bacteriophage aerosol through the Ring IR system. The objective of this project is to provide experimentally derived measurements of the RingIR AG-4000 penetration efficiency, including external exhaust filter for mitigation of exhaust aerosol and operation using MS2 bacteriophage as a biological surrogate to the SARS-CoV-2 virus.

60 APPLIED LIFE SCIENCES↗

Electrical Systems of Pumped Storage Hydropower Plants: Electrical Generation, Machines, Power Electronics, and Power Systems

Adjustable-speed (AS) pumped storage hydropower (PSH) technology has the potential to become a large, consistent contributor to grid stability enabling higher penetrations of wind and solar energy on the future U.S. power system. AS-PSH has high-value characteristics, such as fast response to provide ancillary services to the grid, because it is a power converter interface with the grid (like battery storage), but at the same time it has the energy content large enough to supply both short-term (seconds-to-minutes) and long-term (minutes-to-hours) of energy needs, like more conventional power plants. However, designs must be optimized to lower the capital expenditure (CapEx) and to provide a high-quality grid interface capability (e.g. power quality, ancillary service provider, fault-tolerant or fault ride-through capability), which is a primary factor in the acceptance of AS-PSH into a utility’s generation mix. This CapEx will be greatly affected by the cost savings associated with the civil structure, turbine design, power electronics, control systems, or unique generator designs. A holistic design must be considered to get a full picture of the benefits of the technology proposed. The AS-PSH can be controlled to reduce the impact of transient disturbance on a power system and at the same time can be controlled to minimized subsequent component fatigue and potential oscillation modes within the plant, with the overall impact in reducing the operational expenditures (OpEx).Generating clean power to meet standards such as Institute of Electrical and Electronics Engineers (IEEE) 519 and International Electrotechnical Commission (IEC) 1000-3-2 will be a continuing challenge. For many technology developers, however, improved AS-PSH technologies will become a key component of generator-storage systems of the future given the prospects of increased performance and decreasing costs, and the ever-increasing penetration of renewables (e.g wind power and solar power).

13 HYDRO ENERGY↗

Use of Traveling Wave Signatures in Medium-Voltage Distribution Systems for Fault Detection and Location

Protection systems are a critical feature for the proper operation of a power grid. Protection systems should be able to quickly detect, identify, locate, and isolate the faults within a time frame that prevents damage to grid components and reduces customer outages. As more inverter-based photovoltaics (PV) are integrated into the grid, phasor domain based protection schemes become more inaccurate due to low levels of fault current from inverters or respond too slowly to accurately identify fault conditions. This points to the need to identify and develop novel protection approaches for distribution systems with high penetration of inverter based PV. The main objective of the project is to develop new time domain-based protection schemes to enable more accurate and faster detection, identification and location of faults in distribution systems and/or microgrids with high penetration of inverter-based PV. Our approach aims to exploit the traveling waves that are generated during a fault or other disturbances in the grid.

14 SOLAR ENERGY↗

Sea Breeze Influence on Aerosols and Convection in the Southeastern US

The goal of this research is to describe the inland penetrating sea breeze and interactions with atmospheric phenomena across multiple scales, thereby establishing a baseline of understanding. The land-ocean-atmosphere interface in the southeastern US drives regional sea breeze circulations that impact clouds, convection, and precipitation. We analyzed a variety of atmospheric observations to identify the characteristics and frequency of sea breezes. Sea breezes were identified all along the southeastern Atlantic coast (63% of days from March to September in 2019) at times impacting large areas of the southeastern US. They were found to penetrate inland to the Savannah River Site on about 27% of all days during the typical sea breeze season (March to October) from 2015 to 2020, often leaving a residual layer the following day. Future work focuses on modeling studies, analysis of additional data, and climate impacts on sea breezes.

58 GEOSCIENCES↗

Evaluating the Grid Impact of Oregon Offshore Wind

This analysis used high resolution offshore wind data and a detailed production cost model of the Western Interconnection to explore the value and operational impact of integrating offshore wind along Oregon's coastline. Leveraging local technical stakeholder expertise and input, we determined a set of scenarios to explore. These scenarios varied offshore wind penetrations and explored the differences of integrating offshore wind in the current grid and a potential future grid. This allowed us to determine how changes to the rest of the system and increasing penetrations of offshore wind affected our findings. We identified a number of key findings from the analysis, including that 2.6 GW of nameplate capacity offshore wind could be integrated into the Oregon power system with minimal curtailment due to transmission congestion or other factors. The range of system value provided by offshore wind ranges between $\$$65/MWh and $\$$85/MWh across the various scenarios considered. We also examined the influence offshore wind had on the trans-Cascade power flow, where we determined a strong correlation between offshore wind generation and reduction in flow across the Cascades. Finally, we also determined that offshore wind could serve between 84 - 93% of Coastal Oregon loads depending on the scenario.

17 WIND ENERGY↗

Deploying Intra-hour Uncertainty Analysis Tools to ABB’s GridView - CRADA 445

The quickly-changing generation resource mix in the US grid, with large additions of variable resources, retirements of traditional thermal generation, distributed generation and demand response, are creating new challenges on the traditional operation of both the generation and transmission systems. The ability to perform intra-hour high fidelity production cost modeling (PCM) is needed to allow grid operators and grid planners to integrate high penetration (more than 50%) of variable energy resources, and to make prompt well informed decisions in market operations and planning. In the last decade, PNNL has developed several stand-alone tools to enable grid operators and planners to understand the impact of high variable generation on their systems. These tools have been used is studies such as: (1) Evaluation the benefits of WECC balancing authorities coordination under high variable generation penetration , (2) Benefits of Energy Imbalance Market in the North West Power Pool and (3) Duke Energy and NV Energy solar integration studies. ABB’s GridView is a widely used commercial PCM tool. It is the tool used by WECC and their stakeholders to develop the WECC PCM planning model on bi-annual basis. This proposal is focused on the integrating of PNNL intra-hour uncertainty analysis tools to GridView.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical analysis of filter testing at the U.S. Department of Energy Filter Test Facility

The U.S. Department of Energy (DOE) technical standard DOE-STD-3020-2015 requires verification testing at the Filter Test Facility (FTF) of high-efficiency particulate air (HEPA) filters to be installed in nuclear facility (Hazard Category 1, 2, 3, and radiological facilities) confinement ventilation systems, or to be installed in habitability systems (e.g., filters for protection of workers required to act for the control and mitigation of emergency situations). Filters in these applications perform a safety function in accident situations, are designated as important to safety, or are necessary for habitability systems. Different FTFs have operated for decades, and results of tests are available to examine the need for and benefits of continued execution of 100 percent QA verification testing. The objective of this study and resulting report was to assess the need for 100 percent QA testing at the current FTF in Maryland, based on an examination of a database of test results from 2013 to August 2020. Filters that require independent testing per DOE-STD-3020-2015 to be installed in nuclear facilities are sent to the FTF before being shipped to the facilities. The FTF examines the documentation (e.g., certificates of compliance, results of particle penetration and airflow resistance testing by the manufacturers, labels affixed to filters and packages, and other requirements specified in purchase orders by the nuclear facility operators), implements visual inspections of the physical state of the filters, and checks the dimensions of frames. Filters that meet the documentation and visual inspection requirements are subjected to particle penetration and airflow resistance testing. In case of rejections, the filters are shipped back to the manufacturers, at the cost of the manufacturers, for replacement. Filters that pass all tests are shipped to the nuclear facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Solution to Asymmetric Marangoni GTA Weld Behavior in a Dissimilar Chemistry Stainless Steel Joint [Slides]

Asymmetric and irregular weld morphology is an issue with the 9516 shipping container GTA weld. Observation of the weld puddle and cross sections showed the weld was biased toward the body side of the joint. This issue is attributed to a difference in the sulfur content and Marangoni fluid flow characteristics of the lid (150 ppm) and body (10 ppm) components of the weld joint. An additional contributing factor in this issue is the large difference in mass between the ½” thick lid and 1/8” thick body. A solution was developed comprised of a preliminary partial penetration weave pass across the joint intended to homogenize the sulfur content prior to the full penetration pass.