Partial flocculation for spray drying of spherical mixed metal oxide particles

Abstract Particles are an important design consideration for many proposed solar thermochemical water splitting reactor concepts. These particles must maintain physical integrity and chemical performance at very high temperatures (>900°C) while flowing within a system. Spray drying is a commonly used, scalable method to produce solid spherical particles that have the best opportunity to meet these requirements. Spray drying is used to produce hercynite (FeAl 2 O 4 ) particles using pH ‐modification of a charge‐stabilized sol. This process involves inducing partial flocculation in nanoparticle suspensions to yield larger particles that are spherical and structurally robust. A commercial boehmite suspension is characterized along with a mixture of the boehmite suspension with an iron oxide suspension. Zeta potential near zero and peak yield stress measurements at the same pH indicate flocculation, but associated sedimentation behavior is not observed. The behavior of both the boehmite‐only and mixed suspensions both seem to be driven by the behavior of the boehmite suspension alone. Spray dried particles from the mixed suspension at the critical pH gave significantly larger and more spherical particles, which also indicates flocculation. This relatively simple technique shows promise for new mixed‐metal material formulations and scalable applications.

Ehrhart, Brian D.↗

Chemical Reactor Network Modeling of Ammonia Rich-Quench-Lean Combustion Using a Partially Stirred Reactor Approach

Ammonia is a promising alternative to hydrogen with high energy density and favorable storage and transport characteristics. However, low flammability and a propensity for high nitrogen oxide (NO x ) emissions make direct utilization challenging. Recently, two-stage rich-quench-lean (RQL) combustion strategies have shown promise in achieving low NO x emissions with ammonia. In this approach, the rich stage serves to oxidize a portion of the fuel while thermally decomposing as much of the remaining ammonia as possible, generating hydrogen. In the second (lean) stage, air is rapidly introduced, burning out the hydrogen and residual ammonia. Two-stage RQL combustion of ammonia has been investigated in the open literature both experimentally and numerically. In general, idealized chemical reactor network (CRN) models predict NO x concentrations below those of 2D/3D computational fluid dynamics models and experiments. The primary drivers of these discrepancies may be largely attributed to finite rate mixing nonadiabatic operation. The typical CRN model is comprised of a perfectly-stirred-reactor (PSR), followed by a plug-flow-reactor (PFR), meant to represent the flame, and postflame zones, respectively. In the two-stage RQL approach two PSR-PFR networks are arranged sequentially, corresponding to the rich and lean stages, with secondary air injection in between. In the authors' past work, this arrangement has demonstrated the significant sensitivity of exit NO x to the rich stage equivalence ratio, while the amount of secondary air injection was shown to be less critical. In this paper, the CRN model is extended to (1) include the impacts of heat loss and (2) utilize a partially-stirred-reactor (PaSR) approach to study the impacts of mixing on emissions performance. Varying amounts of heat loss are applied to the rich relaxation zone to understand emissions performance and changes to optimization of equivalence ratio and residence time. Premixed and nonpremixed configurations are considered in the rich stage PaSR, with varying degrees of mixing intensity to study the interaction between mixing, transport, and kinetic timescales. Critically, the impact of mixing between hot products and secondary air injection is studied to understand practical injector needs. Results show unburnt ammonia leaving the rich stage as a primary contributor to NO x emissions – driven both by increased heat loss and reduced mixing rates. Furthermore, heat losses have been shown to create conditions that are conducive to increased N 2 O formation in the lean stage. In conclusion, the results of this study will be considered in the context of developing optimized two-stage RQL combustors for ammonia.

Combustion↗

Cyclic Combustion Variations in Dual Fuel Partially Premixed Pilot-Ignited Natural Gas Engines

Dual fuel pilot ignited natural gas engines are identified as an efficient and viable alternative to conventional diesel engines. This paper examines cyclic combustion fluctuations in conventional dual fuel and in dual fuel partially premixed low temperature combustion (LTC). Conventional dual fueling with 95% (energy basis) natural gas (NG) substitution reduces NOx emissions by almost 90%t relative to straight diesel operation; however, this is accompanied by 98% increase in HC emissions, 10 percentage points reduction in fuel conversion efficiency (FCE) and 12 percentage points increase in COVimep. Dual fuel LTC is achieved by injection of a small amount of diesel fuel (2-3 percent on an energy basis) to ignite a premixed natural gas₋air mixture to attain very low NOx emissions (less than 0.2 g/kWh). Cyclic variations in both combustion modes were analyzed by observing the cyclic fluctuations in start of combustion (SOC), peak cylinder pressures (Pmax), combustion phasing (Ca50), and the separation between the diesel injection event and Ca50 (termed "relative combustion phasing" ). For conventional dual fueling, as % NG increases, Pmax decreases, SOC and Ca50 are delayed, and cyclic variations increase. For dual fuel LTC, as diesel injection timing is advanced from 20° to 60° BTDC, the relative combustion phasing is identified as an important combustion parameter along with SoC, Pmax, and CaPmax. For both combustion modes, cyclic variations were characterized by alternating slow and fast burn cycles, especially at high %NG and advanced injection timings. Finally, heat release return maps were analyzed to demonstrate thermal management strategies as an effective tool to mitigate cyclic combustion variations, especially in dual fuel LTC.

Srinivasan, K. K.↗

A Simulated Evaluation of Powder Flowability Through a Partially Obstructed Consumable in Blown Powder Directed Energy Deposition Systems

Abstract In the interest of continued industrialization of metal additive manufacturing in modern production environments, cost is often referenced as a primary deterrent to new adopters. Conventional economic models for additive systems, processes, and supply chains often focus on specific process applications with little generalizability, or they neglect significant costs associated with production such as machine maintenance and consumable part replacement. Compounding the latter issue are substantial knowledge gaps in consumable part wear characterization for additive and other convergent manufacturing systems. In coaxial blown powder directed energy deposition systems, gas atomized metal powder is wasted during material deposition at a rate that is partly dependent on present wear phenomena in a consumable nozzle housed in the cladding head assembly. The price and lead time required to replace the nozzle incentivizes its reuse even when visibly worn. Often this initiates a process quality decline in the form of underbuilt geometry and internal defects due to losses in powder catchment efficiency. While depositing H13 steel using a hybrid manufacturing machine tool equipped with such a deposition system, a unique partial clog with a bridge-like structure formed at the consumable nozzle exit when supporting argon gas flows failed mid-process. To further understand coaxial multi-phase powder flow in the event of support gas failure, a computational fluid dynamics simulation is tailored to relevant process parameters, H13 powder material profile, and machine operator observations collected after the incident. The resulting differences in powder flow compared to control gas flow parameters is presented and discussed. The powder flowability and performance of the clogged nozzle is then assessed by using an optical profilometer to extract the profile of the clog and recreate the clog geometry within the simulation environment. In past work this simulation has been experimentally validated for a 316L steel powder material profile and used specifically for analyzing powder stream geometry and catchment efficiency. After the initial powder flow characterization, the clog is removed, and the nozzle is reprofiled. After removing the obstructing clog, the newly unobstructed nozzle geometry, the original off the shelf nozzle geometry, and additional nozzle profiles exploring different consumable refurbishment strategies are reevaluated in the simulation. Powder catchment efficiency for all variant nozzle geometries and relevant flow variables are compared and discussed, along with potential mitigation strategies for optimizing powder flowability with worn consumables. This work expands on the known morphology of blown powder obstructions and wear defects present in consumable coaxial nozzles while discussing pragmatic simulation driven responses to unanticipated subsystem failure in hybrid manufacturing machining platforms.

DeWitte, Lisa↗

Operando study of HfO 2 atomic layer deposition on partially hydroxylated Si(111)

The introduction of atomic layer deposition (ALD), to the microelectronics industry has introduced a large number of new possible materials able to be deposited in layers with atomic thickness control. One such material is the high-κ oxide HfO 2 ; thermally stable and ultrathin HfO 2 films deposited by ALD are a significant contender to replace SiO 2 as the gate oxide in capacitor applications. We present a mechanistic study of the first deposition cycle of HfO 2 on the Si(111) surface using tetrakis(dimethylamido) hafnium (TDMAHf) and water as precursors using operando ambient pressure x-ray photoelectron spectroscopy. Here, we show that the hydroxylation of the clean Si(111) surface by residual water vapor, resulting in a 0.3 monolayer coverage of hydroxyls, leads to instantaneous full surface coverage of TDMAHf. The change in the atomic ratio of Hf to C/N found during the first deposition half-cycle, however, does not match the assumed immediate ligand loss through reaction with surface hydroxyls. One would expect an immediate loss of ligands, indicated by a Hf:N ratio of approximately 1:3 as TDMAHf deposits onto the surface; however, a Hf:N ratio of 1:3.6 is observed. The partial hydroxylation on the Si(111) surface leads to binding through the TDMAHf ligand N atoms resulting in both N and CH 3 being found remaining on the surface post water half-cycle. Although there is evidence of ligand exchange reactions occurring at Si–OH sites, it also seems that N binding can occur on bare Si, highlighting the complexity of the substrate/precursor reaction even when hydroxyls are present. Moreover, the initial low coverage of Si–OH/Si–H appears to severely limit the amount of Hf deposited, which we hypothesize is due to the specific geometry of the initial arrangement of Si–OH/Si–H on the rest- and adatoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dosimetric comparison of partial and whole breast external beam irradiation in the treatment of early stage breast cancer

A dosimetric comparison was performed on external-beam three-dimensional conformal partial breast irradiation (PBI) and whole breast irradiation (WBI) plans for patients enrolled in the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 protocol at our institution. Twenty-four consecutive patients were treated with either PBI (12 patients) or WBI (12 patients). In the PBI arm, the lumpectomy cavity was treated to a total dose of 38.5 Gy at 3.85 Gy per fraction twice daily using a four-field noncoplanar beam setup. A minimum 6 h interval was required between fractions. In the WBI arm, the whole breast including the entirety of the lumpectomy cavity was treated to a total dose of 50.4 Gy at 1.8 Gy per fraction daily using opposed tangential beams. The lumpectomy cavity volume, planning target volume for evaluation (PTV{sub E}VAL), and critical structure volumes were contoured for both the PBI and WBI patients. Dosimetric parameters, dose volume histograms (DVHs), and generalized equivalent uniform dose (gEUD) for target and critical structures were compared. Dosimetric results show the PBI plans, compared to the WBI plans, have smaller hot spots in the PTV{sub E}VAL (maximum dose: 104.2% versus 110.9%) and reduced dose to the ipsilateral breast (V50: 48.6% versus 92.1% and V100: 10.2% versus 50.5%), contralateral breast (V3: 0.16% versus 2.04%), ipsilateral lung (V30: 5.8% versus 12.7%), and thyroid (maximum dose: 0.5% versus 2.0%) with p values {<=}0.01. However, similar dose coverage of the PTV{sub E}VAL (98% for PBI and 99% for WBI, on average) was observed and the dose difference for other critical structures was clinically insignificant in both arms. The gEUD data analysis showed the reduction of dose to the ipsilateral breast and lung, contralateral breast and thyroid. In addition, preliminary dermatologic adverse event assessment data suggested reduced skin toxicity for patients treated with the PBI technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tracking the dynamic seroma cavity using fiducial markers in patients treated with accelerated partial breast irradiation using 3D conformal radiotherapy

Purpose: The purpose of the present study was to perform an analysis of the changes in the dynamic seroma cavity based on fiducial markers in early stage breast cancer patients treated with accelerated partial breast irradiation (APBI) using three-dimensional conformal external beam radiotherapy (3D-CRT). Methods: A prospective, single arm trial was designed to investigate the utility of gold fiducial markers in image guided APBI using 3D-CRT. At the time of lumpectomy, four to six suture-type gold fiducial markers were sutured to the walls of the cavity. Patients were treated with a fractionation scheme consisting of 15 fractions with a fractional dose of 333 cGy. Treatment design and planning followed NSABP/RTOG B-39 guidelines. During radiation treatment, daily kV imaging was performed and the markers were localized and tracked. The change in distance between fiducial markers was analyzed based on the planning CT and daily kV images. Results: Thirty-four patients were simulated at an average of 28 days after surgery, and started the treatment on an average of 39 days after surgery. The average intermarker distance (AiMD) between fiducial markers was strongly correlated to seroma volume. The average reduction in AiMD was 19.1% (range 0.0%-41.4%) and 10.8% (range 0.0%-35.6%) for all the patients between simulation and completion of radiotherapy, and between simulation and beginning of radiotherapy, respectively. The change of AiMD fits an exponential function with a half-life of seroma shrinkage. The average half-life for seroma shrinkage was 15 days. After accounting for the reduction which started to occur after surgery through CT simulation and treatment, radiation was found to have minimal impact on the distance change over the treatment course. Conclusions: Using the marker distance change as a surrogate for seroma volume, it appears that the seroma cavity experiences an exponential reduction in size. The change in seroma size has implications in the size of the CTV, PTV, and percent of normal breast tissue irradiated when using 3D-CRT.

60 APPLIED LIFE SCIENCES↗

SU-E-I-59: Image Quality and Dose Measurement for Partial Cone-Beam CT

Purpose: To characterize performance of cone beam CT (CBCT) used in dentistry investigating quantitatively the image quality and radiation dose during dental CBCT over different settings for partial rotation of the x-ray tube. Methods: Image quality and dose measurements were done on a variable field of view (FOV) dental CBCT (Carestream 9300). X-ray parameters for clinical settings were adjustable for 2–10 mA, 60–90 kVp, and two optional voxel size values, but time was fixed for each FOV. Image quality was assessed by scanning cylindrical poly-methyl methacrylate (PMMA) image quality phantom (SEDENTEXCT IQ), and then the images were analyzed using ImageJ to calculate image quality parameters such as noise, uniformity, and contrast to noise ratio (CNR). A protocol proposed by SEDENTEXCT, dose index 1 (DI1), was applied to dose measurements obtained using a thimble ionization chamber and cylindrical PMMA dose index phantom (SEDENTEXCT DI). Dose distributions were obtained using Gafchromic film. The phantoms were positioned in the FOV to imitate a clinical positioning. Results: The image noise was 6–12.5% which, when normalized to the difference of mean voxel value of PMMA and air, was comparable between different FOVs. Uniformity was 93.5ß 99.7% across the images. CNR was 1.7–4.2 and 6.3–14.3 for LDPE and Aluminum, respectively. Dose distributions were symmetric about the rotation angle's bisector. For large and medium FOVs at 4 mA and 80–90 kVp, DI1 values were in the range of 1.26–3.23 mGy. DI1 values were between 1.01–1.93 mGy for small FOV (5×5 cm{sup 2}) at 4–5 mA and 75–84 kVp. Conclusion: Noise decreased by increasing kVp, and the CNR increased for each FOV. When FOV size increased, image noise increased and CNR decreased. DI1 values were increased by increasing tube current (mA), tube voltage (kVp), and/or FOV. Funding for this project from NSERC Discovery grant, UBC Faculty of Dentistry Research Equipment Grant and UBC Faculty of Dentistry S. Wah Leung Endowment Fund.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-76: Incorporation of Ultrasound Elastography in Target Volume Delineation for Partial Breast Radiotherapy Planning: A Comparative Study

Purpose: There is substantial observer variability in the delineation of target volumes for post-surgical partial breast radiotherapy because the tumour bed has poor x-ray contrast. This variability may result in substantial variations in planned dose distribution. Ultrasound elastography (USE) has an ability to detect mechanical discontinuities and therefore, the potential to image the scar and distortion in breast tissue architecture. The goal of this study was to compare USE techniques: strain elastography (SE), shear wave elastography (SWE) and acoustic radiation force impulse (ARFI) imaging using phantoms that simulate features of the tumour bed, for the purpose of incorporating USE in breast radiotherapy planning. Methods: Three gelatine-based phantoms (10% w/v) containing: a stiff inclusion (gelatine 16% w/v) with adhered boundaries, a stiff inclusion (gelatine 16% w/v) with mobile boundaries and fluid cavity inclusion (to mimic seroma), were constructed and used to investigate the USE techniques. The accuracy of the elastography techniques was quantified by comparing the imaged inclusion with the modelled ground-truth using the Dice similarity coefficient (DSC). For two regions of interest (ROI), the DSC measures their spatial overlap. Ground-truth ROIs were modelled using geometrical measurements from B-mode images. Results: The phantoms simulating stiff scar tissue with adhered and mobile boundaries and seroma were successfully developed and imaged using SE and SWE. The edges of the stiff inclusions were more clearly visible in SE than in SWE. Subsequently, for all these phantoms the measured DSCs were found to be higher for SE (DSCs: 0.91–0.97) than SWE (DSCs: 0.68–0.79) with an average relative difference of 23%. In the case of seroma phantom, DSC values for SE and SWE were similar. Conclusion: This study presents a first attempt to identify the most suitable elastography technique for use in breast radiotherapy planning. Further analysis will include comparison of ARFI with SE and SWE. This work is supported by the EPSRC Platform Grant, reference number EP/H046526/1.

60 APPLIED LIFE SCIENCES↗

SU-E-T-487: Impact of Geometric Uncertainties in Accelerated Partial Breast Irradiation Using the Strut-Adjusted Volume Implant (SAVI)

Purpose: Single-entry multi-catheter devices have been developed for accelerated partial breast irradiation (APBI). Rotational and translational uncertainties are usually mitigated by quality assurance, however its actual dosimetric impact has not been addressed, which is presented here for SAVI applicator. Methods: Under Institutional Review Board exemption status, we retrospectively analyzed 48 APBI treatment plans using SAVI applicator. For quick calculation of dose-volume histogram (DVH) considering geometric uncertainties, the coordinate of each voxel of critical organs after rotation or translation along the central catheter was calculated using an in-house software instead of rotating or translating the entire dose distribution. Results: For most cases, the skin doses increased with rotation to both directions. At 10 degree of rotation, the increase of Dmax (percent prescribed dose) at 50% (median), 75%, 90%, and 100% (maximum) percentile were 0.3%, 1.7%, 5.6% and 25.0%, respectively. The increase of chest wall Dmax at 50%, 75%, 90%, and 100% percentile were 0.1%, 1.0%, 10.3% and 38.8%, respectively. The increase of skin Dmax of the patients with the distance between skin surface and lumpectomy cavity surface ≤16 mm was significantly larger than those with the distance >16 mm. Similarly, patients with the distance between lung and lumpectomy cavity surface ≤20 mm showed higher sensitivity of chest wall Dmax against rotation than patients with the distance <20 mm. Translation of the applicator showed larger impact on the skin dose than rotation, although the effects on chest wall was less than 2% even at 10 mm displacement. At 5 mm of translation, increase of skin Dmax at 50%, 75%, 90%, and 100% percentile were 2.3%, 8.0%, 15.3% and 77.7%, respectively. Conclusion: The impacts of the geometric uncertainties (rotation and translation) of SAVI applicator were investigated. The skin-lumpectomy cavity and lung-lumpectomy cavity distances showed significant relationship with skin and chest wall doses, respectively.

60 APPLIED LIFE SCIENCES↗

SU-E-T-528: Robustness Evaluation for Fiducial-Based Accelerated Partial Breast Proton Therapy

Purpose: To investigate the robustness of the proton treatment plans in the presence of rotational setup error when patient is aligned with implanted fiducials. Methods: Five Stage I invasive breast cancer patients treated with the APBP protocol (PCG BRE007-12) were studied. The rotational setup errors were simulated by rotating the original CT images around the body center clockwise and counterclockwise 5 degrees (5CW and 5CCW). Manual translational registration was then performed to match the implanted fiducials on the rotated images to the original dataset. Patient contours were copied to the newly created CT set. The original treatment plan was applied to the new CT dataset with the beam isocenter placed at the geometrical center of PTV. The dose distribution was recalculated for dosimetric parameters comparison. Results: CTV and PTV (D95 and V95) coverages were not significantly different between the two simulated plans (5CW and 5CCW) and the original plan. PTV D95 and CTV D95 absolute difference among the three plans were relatively small, with maximum changes of 0.28 CGE and 0.15 CGE, respectively. PTV V95 and CTV V95 absolute differences were 0.79% and 0.48%. The dosage to the thyroid, heart, contralateral breast and lung remained zero for all three plans. The Dmax and Dmean to the volume of ipsilateral breast excluding CTV were compared, with maximum difference values of 1.02 CGE for Dmax and 3.56 CGE for Dmean. Ipsilateral lung Dmean maintained no significant changes through the three plan comparison, with the largest value 0.32 CGE. Ipsilateral lung Dmax was the most sensitive parameter to this simulation study, with a maximum difference at 20.2 CGE. Conclusion: Our study suggests that fiducial-based Accelerated Partial Breast Proton Therapy is robust with respect to +/− 5 degree patient setup rotational errors, as long as the internal fiducial markers are used for patient alignment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-619: Comparison of CyberKnife Versus HDR (SAVI) for Partial Breast Irradiation

Purpose: Compare SAVI plans and CyberKnife (CK) plans for the same accelerated course. Methods and Materials: Three SAVI patients were selected. Pre-SAVI CTs were used for CK planning. All prescriptions are 3400cGy in 10 fractions BID. Max dose to skin and chestwall is 425cGy. For SAVI, PTV is a 1cm expansion of the cavity minus the cavity. For CK, CTV is a 1cm expansion of the seroma, with 2mm margin. CK plans are normalized to SAVI, so that in both cases the 323cGy isodose line covers the same percentage of PTV. For CK Fiducial/Synchrony tracking is used. Results: In the following, all doses are per fraction and results are averaged. The PTVs for the CK plans are 2.4 times larger than the corresponding SAVI PTVs. Nonetheless the CK plans meet all constraints and are superior to SAVI plans in several respects. Max skin dose for SAVI vs CK is 332cGy vs 337cGy. Max dose to chestwall is 252cGy vs 286cGy. The volume of lung over 125cGy is 6.4cc for SAVI and 2.5cc for CK. Max heart dose is 60cGy for SAVI and 83cGy for CK. The volume of PTV receiving over 425cGy is 49cc for SAVI and 1.3cc for CK. Max dose to contra-lateral breast is 16cGy for SAVI and 4.5cGy for CK. Conclusion: CK PTVs are directly derived from the seroma. Corresponding SAVI PTVs tend to be much smaller. Dosimetrically, CK plans are equivalent or superior to SAVI plans despite the larger PTVs. Interestingly, the dose delivered to the lung is higher in SAVI vs CK. Fiducial/Synchrony tracking employed by CK might reduce errors in delivery compared to errors associated with shifts of the SAVI implant. In conclusion, when CK is an option for partial breast irradiation it may preferable to SAVI.

60 APPLIED LIFE SCIENCES↗

WE-G-BRE-09: Targeted Radiotherapy Enhancement During Accelerated Partial Breast Irradiation (ABPI) Using Controlled Release of Gold Nanoparticles (GNPs)

Purpose: Several studies have demonstrated low rates of local recurrence with brachytherapy-based accelerated partial breast irradiation (APBI). However, long-term outcomes on toxicity (e.g. telangiectasia), and cosmesis remain a major concern. The purpose of this study is to investigate the dosimetric feasibility of using targeted non-toxic radiosensitizing gold nanoparticles (GNPs) for localized dose enhancement to the planning target volume (PTV) during APBI while reducing dose to normal tissue. Methods: Two approaches for administering the GNPs were considered. In one approach, GNPs are assumed to be incorporated in a micrometer-thick polymer film on the surface of routinely used mammosite balloon applicators, for sustained controlled in-situ release, and subsequent treatment using 50-kVp Xoft devices. In case two, GNPs are administered directly into the lumpectomy cavity e.g. via injection or using fiducials coated with the GNP-loaded polymer film. Recent studies have validated the use of fiducials for reducing the PTV margin during APBI with 6 MV beams. An experimentally determined diffusion coefficient was used to determine space-time customizable distribution of GNPs for feasible in-vivo concentrations of 43 mg/g. An analytic calculational approach from previously published work was employed to estimate the dose enhancement due to GNPs (2 and 10 nm) as a function of distance up to 1 cm from lumpectomy cavity. Results: Dose enhancement due to GNP was found to be about 130% for 50-kVp x-rays, and 110% for 6-MV external beam radiotherapy, 1 cm away from the lumpectomy cavity wall. Higher customizable dose enhancement could be achieved at other distances as a function of nanoparticle size. Conclusion: Our preliminary results suggest that significant dose enhancement can be achieved to residual tumor cells targeted with GNPs during APBI with electronic brachytherapy or external beam therapy. The findings provide a useful basis for developing nanoparticle-aided APBI, with potential to significantly reduce normal tissue/skin toxicity.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-09: Planning and Delivery of the Fully Dynamic Trajectory Modulated Arc Therapy: Application to Accelerated Partial Breast Irradiation

Purpose: A novel trajectory modulated arc therapy (TMAT) system was developed that uses source motion trajectory involving synchronized gantry rotation with translational and rotational couch movement. MLC motion and dose rate were fully optimized for dynamic beam delivery. This work presents a platform for planning deliverable TMAT on a collision free coronal trajectory and evaluates its benefit for accelerated partial breast irradiation (APBI) in a prone position. Methods: The TMAT algorithm was built on VMAT with modifications (physical properties on couch movement were defined) and enhancements (pencil beam dose calculation engine to support extended SSDs) to make it feasible for TMAT delivery. A Matlab software environment for TMAT optimization and dose calculation was created to allow any user specified motion axis. TMAT delivery was implemented on Varian TrueBeamTM STx via XML scripts. 10 prone breast irradiation cases were evaluated in VMAT and compared with a 6- field non-coplanar IMRT plan. Patient selection/exclusion criteria and structure contouring followed the guidelines of NSABP B-39/RTOG 0413 protocol. Results: TMAT delivery time was ∼4.5 minutes. 251.5°±7.88° of non-isocentric couch arc was achieved by the optimized trajectory with 180– 210 control points at 1°–2° couch increments. The improved dose distribution by TMAT was most clearly observed by the marked reduction in the volume of irradiated normal breast tissue in the high dose region. The ratios of the normal breast tissue volume receiving more than 50%, 80% and 100% of the prescription dose for TMAT versus IMRT were: V50%(TMAT/IMRT) = 78.38%±13.03%, V80%(TMAT/IMRT) = 44.19%±9.04% and V100% (TMAT/IMRT) = 9.96%±7.55%, all p≤0.01. Conclusion: The study is the first demonstration of planning and delivery implementation of a fully dynamic APBI TMAT system with continuous couch motion. TMAT achieved significantly improved dosimetry over noncoplanar IMRT on dose volume parameters correlated with toxicity and cosmetic outcome of APBI. This project was supported by Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

Sci—Thur PM: Planning and Delivery — 04: Respiratory margin derivation and verification in partial breast irradiation

Partial breast irradiation (PBI) following breast-conserving surgery is emerging as an effective means to achieve local control and reduce irradiated breast volume. Patients are planned on a static CT image; however, treatment is delivered while the patient is free-breathing. Respiratory motion can degrade plan quality by reducing target coverage and/or dose homogeneity. A variety of methods can be used to determine the required margin for respiratory motion in PBI. We derive geometric and dosimetric respiratory 1D margin. We also verify the adequacy of the typical 5 mm respiratory margin in 3D by evaluating plan quality for increasing respiratory amplitudes (2–20 mm). Ten PBI plans were used for dosimetric evaluation. A database of volunteer respiratory data, with similar characteristics to breast cancer patients, was used for this study. We derived a geometric 95%-margin of 3 mm from the population respiratory data. We derived a dosimetric 95%-margin of 2 mm by convolving 1D dose profiles with respiratory probability density functions. The 5 mm respiratory margin is possibly too large when 1D coverage is assessed and could lead to unnecessary normal tissue irradiation. Assessing margins only for coverage may be insufficient; 3D dosimetric assessment revealed degradation in dose homogeneity is the limiting factor, not target coverage. Hotspots increased even for the smallest respiratory amplitudes, while target coverage only degraded at amplitudes greater than 10 mm. The 5 mm respiratory margin is adequate for coverage, but due to plan quality degradation, respiratory management is recommended for patients with respiratory amplitudes greater than 10 mm.

60 APPLIED LIFE SCIENCES↗

A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction

Purpose: Partial volume effect (PVE) plays an important role in both qualitative and quantitative PET image accuracy, especially for small structures. A previously proposed voxelwise PVE correction method applied on PET reconstructed images involves the use of Lucy–Richardson deconvolution incorporating wavelet-based denoising to limit the associated propagation of noise. The aim of this study is to incorporate the deconvolution, coupled with the denoising step, directly inside the iterative reconstruction process to further improve PVE correction. Methods: The list-mode ordered subset expectation maximization (OSEM) algorithm has been modified accordingly with the application of the Lucy–Richardson deconvolution algorithm to the current estimation of the image, at each reconstruction iteration. Acquisitions of the NEMA NU2-2001 IQ phantom were performed on a GE DRX PET/CT system to study the impact of incorporating the deconvolution inside the reconstruction [with and without the point spread function (PSF) model] in comparison to its application postreconstruction and to standard iterative reconstruction incorporating the PSF model. The impact of the denoising step was also evaluated. Images were semiquantitatively assessed by studying the trade-off between the intensity recovery and the noise level in the background estimated as relative standard deviation. Qualitative assessments of the developed methods were additionally performed on clinical cases. Results: Incorporating the deconvolution without denoising within the reconstruction achieved superior intensity recovery in comparison to both standard OSEM reconstruction integrating a PSF model and application of the deconvolution algorithm in a postreconstruction process. The addition of the denoising step permitted to limit the SNR degradation while preserving the intensity recovery. Conclusions: This study demonstrates the feasibility of incorporating the Lucy–Richardson deconvolution associated with a wavelet-based denoising in the reconstruction process to better correct for PVE. Future work includes further evaluations of the proposed method on clinical datasets and the use of improved PSF models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of registration accuracy in accelerated partial breast irradiation using the point-based rigid-body registration algorithm for patients with implanted fiducial markers

Purpose: To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. Methods: Twenty-two consecutive patients were enrolled in a prospective trial examining 10-fraction APBI. Titanium clips were implanted intraoperatively around the seroma in all patients. For image-registration, the positions of the clips in daily kV x-ray images were matched to those in the planning digitally reconstructed radiographs. Fiducial and gravity registration errors (FREs and GREs, respectively), representing resulting misalignments of the edge and center of the target, respectively, were compared between the manual and algorithm-based methods. Results: In total, 218 fractions were evaluated. Although the mean FRE/GRE values for the manual and algorithm-based methods were within 3 mm (2.3/1.7 and 1.3/0.4 mm, respectively), the percentages of fractions where FRE/GRE exceeded 3 mm using the manual and algorithm-based methods were 18.8%/7.3% and 0%/0%, respectively. Manual registration resulted in 18.6% of patients with fractions of FRE/GRE exceeding 5 mm. The patients with larger clip deviation had significantly more fractions showing large FRE/GRE using manual registration. Conclusions: For image-registration using fiducial markers in APBI, the manual registration results in more fractions with considerable registration error due to loss of fiducial objectivity resulting from their deviation. The authors recommend the PRBR algorithm as a safe and effective strategy for accurate, image-guided registration and PTV margin reduction.

60 APPLIED LIFE SCIENCES↗

SU-E-J-37: Feasibility of Utilizing Carbon Fiducials to Increase Localization Accuracy of Lumpectomy Cavity for Partial Breast Irradiation

Purpose To investigate the feasibility of utilizing carbon fiducials to increase localization accuracy of lumpectomy cavity for partial breast irradiation (PBI). Methods Carbon fiducials were placed intraoperatively in the lumpectomy cavity following resection of breast cancer in 11 patients. The patients were scheduled to receive whole breast irradiation (WBI) with a boost or 3D-conformal PBI. WBI patients were initially setup to skin tattoos using lasers, followed by orthogonal kV on-board-imaging (OBI) matching to bone per clinical practice. Cone beam CT (CBCT) was acquired weekly for offline review. For the boost component of WBI and PBI, patients were setup with lasers, followed by OBI matching to fiducials, with final alignment by CBCT matching to fiducials. Using carbon fiducials as a surrogate for the lumpectomy cavity and CBCT matching to fiducials as the gold standard, setup uncertainties to lasers, OBI bone, OBI fiducials, and CBCT breast were compared. Results Minimal imaging artifacts were introduced by fiducials on the planning CT and CBCT. The fiducials were sufficiently visible on OBI for online localization. The mean magnitude and standard deviation of setup errors were 8.4mm ± 5.3 mm (n=84), 7.3mm ± 3.7mm (n=87), 2.2mm ± 1.6mm (n=40) and 4.8mm ± 2.6mm (n=87), for lasers, OBI bone, OBI fiducials and CBCT breast tissue, respectively. Significant migration occurred in one of 39 implanted fiducials in a patient with a large postoperative seroma. Conclusion OBI carbon fiducial-based setup can improve localization accuracy with minimal imaging artifacts. With increased localization accuracy, setup uncertainties can be reduced from 8mm using OBI bone matching to 3mm using OBI fiducial matching for PBI treatment. This work demonstrates the feasibility of utilizing carbon fiducials to increase localization accuracy to the lumpectomy cavity for PBI. This may be particularly attractive for localization in the setting of proton therapy and other scenarios in which metal clips are contraindicated.

60 APPLIED LIFE SCIENCES↗