At least 1,423 records · Page 79

Multiple wavelength geodesy

An apparatus is being constructed which should be able to measure baselines up to 50 km long with a fractional uncertainty of about 5 x 10 to the -8 power. The instrument will measure both the optical length and the required correction due to the refractivity of the atmosphere, using three wavelengths transmitted in one direction over the path to an active receiver. The three wavelengths are 632.8 nm, 441.6 nm and 3.7 cm. The two endpoint instruments are synchronized using subsidiary return transmissions at 632.8 nm and another telemetry signal. The one-way nature of the system allows an increase in range over existing round-trip systems.

Levine, J.↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗

Development of the Optical Communications Telescope Laboratory: A Laser Communications Relay Demonstration Ground Station

The Laser Communications Relay Demonstration (LCRD) project will demonstrate high bandwidth space to ground bi-directional optical communications links between a geosynchronous satellite and two LCRD optical ground stations located in the southwestern United States. The project plans to operate for two years with a possible extension to five. Objectives of the demonstration include the development of operational strategies to prototype optical link and relay services for the next generation tracking and data relay satellites. Key technologies to be demonstrated include adaptive optics to correct for clear air turbulence-induced wave front aberrations on the downlink, and advanced networking concepts for assured and automated data delivery. Expanded link availability will be demonstrated by supporting operations at small sun-Earth-probe angles. Planned optical modulation formats support future concepts of near-Earth satellite user services to a maximum of 1.244 Gb/s differential phase shift keying modulation and pulse position modulations formats for deep space links at data rates up to 311 Mb/s. Atmospheric monitoring instruments that will characterize the optical channel during the link include a sun photometer to measure atmospheric transmittance, a solar scintillometer, and a cloud camera to measure the line of sight cloud cover. This paper describes the planned development of the JPL optical ground station.

optical commuication↗

Backscatter Ultraviolet (BUV) Instrument

This final project report covers the design, development, construction, testing and qualification of the NIMBUS D BUV (Backscatter Ultraviolet) instrument. The instrument was designed and constructed in accordance with GSFC specification S-623-P-l and amendments. The design phase consisted of activity in three areas of technology: (1) Optical, (2) Mechanical, and (3) Electrical. Beckman Instruments, Inc. performed the tasks concerned with optical and mechanical design while Analog Technology Corporation was the electronics subcontractor. Initial studies resulted in the development of a breadboard model of the BUV instrument. Following extensive testing, additional mathematical analyses, and required modifications, preliminary and critical design reviews were performed. The results of these activities were the construction of an engineering model, used for extensive testing and demonstration of the final design features. Final design data resulted in the construction of two flight-rated instruments, serial numbers P103 and Fl04. On April 8, 1970, the P103 instrument was successfully launched into orbit on NIMBUS D and is presently fully operational.

Source record↗

Nuclear Science Symposium, 30th, and Symposium on Nuclear Power Systems, 15th, San Francisco, CA, October 19-21, 1983, Proceedings

The range of disciplines covered includes physics instrumentation, data acquisition, FASTBUS, radiation detectors, scintillators, photomultipliers and optical detectors, subnanosecond 2-D imaging, medical and health instrumentation, reactor instrumentation, and space instrumentation. Cerenkov detectors, the prevention and rate capability of breakdown processes in wire chambers, and an interactive parallel processor for data analysis are studied. Attention is also given to bismuth germanate's role in gamma-ray spectroscopy, and the construction of a broadband universal sampling head is described. Gamma-ray imaging with a rotating hexagonal uniform redundant array, and broadband X-ray astronomical spectrometry are considered.

Nakamura, M.↗

Arm deploy mechanisms to help correct the Hubble Space Telescope's vision

As has been well publicized, the primary mirror of the Hubble Space Telescope was manufactured with an incorrect curvature which results in an aberrated output image. Ball Aerospace, under contract to GSFC, is designing the Corrective Optics Space Telescope Axial Replacement (COSTAR) to provide correcting optics for the existing axial science instruments in the telescope. Integral to COSTAR are the arm deploy mechanisms which position and hold the corrective optic mirrors.

Copeland, F. Kent↗

Instrumentation for In-Flight SSME Rocket Engine Plume Spectroscopy

This paper describes instrumentation that is under development for an in-flight demonstration of a plume spectroscopy system on the space shuttle main engine. The instrumentation consists of a nozzle mounted optical probe for observation of the plume, and a spectrometer for identification and quantification of plume content. This instrumentation, which is intended for use as a diagnostic tool to detect wear and incipient failure in rocket engines, will be validated by a hardware demonstration on the Technology Test Bed engine at the Marshall Space Flight Center.

Madzsar, George C.↗

Development of a Submillimeter/Far-Infrared Radiometer for Cirrus Measurements

We introduce a low-cost, lightweight and compact polarisation-sensitive radiometer for the measurement of Cirrus clouds in the submillimeter and far-infrared region (10 150 cm-1). It is widely recognised that enhanced global measurements of cirrus properties are essential to the development of General Circulation and Climate Prediction Models since cirrus clouds have a strong effect on the Earth's Global Radiation Budget. The purpose of this project is to design and build a novel instrument suitable for aircraft deployment in order to measure Ice Water Path (IWP) along with cirrus particle size and shape. This airborne instrument, which is currently under development in Cardiff, will serve as a prototype for a future satellite-based radiometer. The radiometer will capitalize on the ongoing measurements of the NASA-led, Fourier Transform interferometer-based, FIRSC (Far-Infrared Sensor for Cirrus) instrument for which Cardiff has been closely associated. Data from FIRSC campaigns is being used to select optimum radiometer channels that exhibit good sensitivity to specific cirrus. This new multichannel radiometer will, however, have some key advantages over similar spectroscopic instruments, for example, portability, increased optical efficiency, a multi-angle field of view and a reduced integration period leading to an improved spatial resolution. The radiometer will benefit from the application of state-of-the-art submm/FIR polarizer and solid filter technology currently being developed in Cardiff. The instrument will require a detector array that is robust enough to withstand aircraft/space deployment.

Hayton, Darren↗

Honeywell multispectral linear array (MLA) instrument design A system overview

In support of NASA's Experimental Land Observing System, a simple, reliable and relatively inexpensive multispectral linear array (MLA) instrument concept has been developed. The design satisfies requirements for multichannel radiometry and wide field imaging. A reflective off-axis anastigmat telescope is mounted in a highly strength-to-weight efficient truss structure, coupled to a solid beamsplitter assembly. Attention is given to the optical design of the MLA instrument, the telescope structure, the detector arrays, detector cooling, on-orbit calibration, signal processing electronics, the spacecraft interfaces, the modulation transfer function, the signal-to-noise ratio, radiometric accuracy, and spatial registration.

Eyring, D.↗

Architecture and performance of astronomical adaptive optics systems

In recent years the technological advances of adaptive optics have enabled a great deal of innovative science. In this lecture I review the system-level design of modern astronomical AO instruments, and discuss their current capabilities.

adaptive optic systems astronomical instruments Fo↗

Pressure-Measuring Diaphragm Transmits Optical Signals

Proposed sapphire diaphragm performs two functions in instrumented research engine or pressure vessel. Serves both as pressure sensor and as window for observation, optical probing, or optical transmission of other measurements. Deflections of sapphire diaphragm alters resistances of strain gauges mounted around its periphery. At same time, transparent material enables optical measurements of conditions in chamber. Additional information obtained about conditions in chamber without need for additional sensor mounts.

Hill, Arthur J.↗

A science-driven approach to optimize the design for a biological small-angle neutron scattering instrument

Biological small-angle neutron scattering (SANS) instruments facilitate critical analysis of the structure and dynamics of complex biological systems. However, with the growth of experimental demands and the advances in optical systems design, a new neutron optical concept is necessary to overcome the limitations of current instruments. This work presents an approach to include experimental objectives ( i.e. the science to be supported by a specific neutron scattering instrument) in the optimization of the neutron optical concept. The approach for a proposed SANS instrument at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory, USA, is presented here. Further, the instrument is simulated with the McStas software package. The optimization process is driven by an evolutionary algorithm using McStas output data, which are processed to calculate an objective function designed to quantify the expected performance of the simulated neutron optical configuration for the intended purpose. Each McStas simulation covers the complete instrument, from source to detector, including realistic sample scattering functions. This approach effectively navigates a high-dimensional parameter space that is otherwise intractable; it allows the design of next-generation SANS instruments to address specific scientific cases and has the potential to increase instrument performance compared with traditional design approaches.

47 OTHER INSTRUMENTATION↗

Development of Multi-Beam Long Trace Profiler

In order to fulfill the angular resolution requirements and make the performance goals for future NASA missions feasible, it is crucial to develop instruments capable of fast and precise figure metrology of x-ray optical elements for further correction of the surface errors. The Long Trace Profilometer (LTP) is an instrument widely used for measuring the surface figure of grazing incidence X-ray mirrors. In the case of replicated optics designed for x-ray astronomy applications, such as mirrors and the corresponding mandrels have a cylindrical shape and their tangential profile is parabolic or hyperbolic. Modern LTPs have sub-microradian accuracy, but the measuring speed is very low, because the profilometer measures surface figure point by point using a single laser beam. The measurement rate can be significantly improved by replacing the single optical beam with multiple beams. The goal of this study is to demonstrate the viability of multi-beam metrology as a way of significantly improving the quality and affordability of replicated x-ray optics. The multi-beam LTP would allow one- and two-dimensional scanning with sub-microradian resolution and a measurement rate of about ten times faster compared to the current LTP. The design details of the instrument's optical layout and the status of optical tests will be presented.

Kilaru, Kiranmayee↗

Phase-Shifted Laser Feedback Interferometry

Phase-shifted, laser feedback interferometry is a new diagnostic tool developed at the NASA Lewis Research Center under the Advanced Technology Development (ATD) Program directed by NASA Headquarters Microgravity Research Division. It combines the principles of phase-shifting interferometry (PSI) and laser-feedback interferometry (LFI) to produce an instrument that can quantify both optical path length changes and sample reflectivity variations. In a homogenous medium, the optical path length between two points is the product of the index of refraction and the geometric distance between the two points. LFI differs from other forms of interferometry by using the laser as both the source and the phase detector. In LFI, coherent feedback of the incident light either reflected directly from a surface or reflected after transmission through a region of interest will modulate the output intensity of the laser. The combination of PSI and LFI has produced a robust instrument, based on a low-power helium-neon (HeNe) gas laser, with a high dynamic range that can be used to measure either static or oscillatory changes of the optical path length. Small changes in optical path length are limited by the fraction of a fringe that can be measured; we can measure nonoscillatory changes with a root mean square (rms) error of the wavelength/1000 without averaging.

Ovryn, Benjie↗

Temperature dependent index of refraction compensation and radiation resistance in monolithic optical systems

Monolithic catadioptric optical systems are susceptible to defocus errors caused by inhomogeneous temperature within the glass material due to temperature dependent index of refraction. This invention discloses methods to mitigate these errors using tuned materials in its optical design coupled with active optical radiative heating to provide optimal performance and includes methods to enhance radiation resistance.

36 MATERIALS SCIENCE↗

Interferometer Measures Broardband Surface Acoustic Waves

Dual differential interferometer uses two pairs of orthogonallypolarized optical beams to measure amplitude and orientation of broadband ultrasonic surface acoustic waves. Instrument modular, and sensitivity limited only by optical detector used.

Claus, R. O.↗

A laser fluorescence anemometer system for the Langley 16- by 24-inch water tunnel

A laser fluorescence anemometer which comprises a three-component laser Doppler velocimeter system with a fourth channel to measure fluorescent dye concentration has been installed in the NASA Langley 16- by 24-in water tunnel. The system includes custom designed optics, data acquisition, and traverse control instruments and a custom software package. Feasibility studies demonstrated how water tunnels can be used in conjunction with advanced optical techniques to provide nonintrusive detailed flow field measurements of complex fluid flows with a minimum of expense. The measurements show that the laser fluorescence anemometer can provide new insight into the structure, entrainment, control and of mixing vortical and shear layer flows.

Owen, F. K.↗

Comparison of Coincident Multiangle Imaging Spectroradiometer and Moderate Resolution Imaging Spectroradiometer Aerosol Optical Depths over Land and Ocean Scenes Containing Aerosol Robotic Network Sites

The Multiangle Imaging Spectroradiometer (MISR) and the Moderate Resolution Imaging Spectroradiometer (MODIS), launched on 18 December 1999 aboard the Terra spacecraft, are making global observations of top-of-atmosphere (TOA) radiances. Aerosol optical depths and particle properties are independently retrieved from these radiances using methodologies and algorithms that make use of the instruments corresponding designs. This paper compares instantaneous optical depths retrieved from simultaneous and collocated radiances measured by the two instruments at locations containing sites within the Aerosol Robotic Network (AERONET). A set of 318 MISR and MODIS images, obtained during the months of March, June, and September 2002 at 62 AERONET sites, were used in this study. The results show that over land, MODIS aerosol optical depths at 470 and 660 nm are larger than those retrieved from MISR by about 35% and 10% on average, respectively, when all land surface types are included in the regression. The differences decrease when coastal and desert areas are excluded. For optical depths retrieved over ocean, MISR is on average about 0.1 and 0.05 higher than MODIS in the 470 and 660 nm bands, respectively. Part of this difference is due to radiometric calibration and is reduced to about 0.01 and 0.03 when recently derived band-to-band adjustments in the MISR radiometry are incorporated. Comparisons with AERONET data show similar patterns.

Moderate Resolution Imaging Spectroradiometer (MOD↗