Impact of Wide-Area Oscillation Damping Control using Measurement-Driven Approach on System Separation - Saudi Grid Case Study

In any interconnected power grid, low-frequency oscillations is a major problem that can limit the power transfer capability and deteriorate power system security due to potential low-damped or even undamped oscillations. Synchronized measurements provided by PMUs enable the design and development of wide-area oscillation damping controllers (WADC) based on measurement-driven model to overcome the limitations of traditional controllers. This work focuses on the impact of a W ADC based on a measurement-driven approach on system separation for the Saudi Electricity Company (SEC) grid. A grid model is provided by SEC for this study. Modal analysis is performed to identify the oscillation mode of interest for which the controller is designed. Damping the dominant oscillation mode helps slightly to improve transient stability of the system. Considering bus frequency at different locations in SEC's system as the candidate observation signals, the optimal observation signal is chosen for the W ADC by using the FFT method. The system transfer function model is constructed by utilizing probing measurements. Then, the W ADC parameters are calculated based on the identified model. The performance of the designed W ADC is tested under different contingencies.

Altarjami, Ibrahim↗

Serum Transforming Growth Factor-β1 Change After Neoadjuvant Chemoradiation Therapy Is Associated With Postoperative Pulmonary Complications in Esophageal Cancer Patients Undergoing Combined Modality Therapy

Purpose: Our aim was to investigate the association of clinical factors, dosimetric parameters, and biomarkers with postoperative pulmonary complications (PPCs) in patients with locally advanced esophageal squamous cell carcinoma (ESCC) treated by neoadjuvant concurrent chemoradiation therapy (CCRT) under strict pulmonary dose constraints and esophagectomy. Methods and Materials: We prospectively enrolled 112 patients undergoing trimodality treatment (including radiation therapy [40 Gy], concurrent taxane-/5-fluorouracil-based regimens, and radical esophagectomy) for ESCC. A PPC was defined as pneumonia or acute respiratory distress syndrome within 30 days after surgery. Serum samples were collected before and within 1 month after CCRT. The association of serum biomarkers with PPCs was detected by proximity ligation assay (PLA) and verified by enzyme-linked immunosorbent assay. Associations of clinical factors, lung dosimetric parameters, and biomarkers with PPC were tested statistically. Results: Thirty-three patients (29.5%) had PPCs. None of the dosimetric parameters was associated with PPCs. Preoperative functional vital capacity (FVC) was significantly associated with PPCs (P=.004). Of the 15 PLA-screened biomarkers, posttreatment transforming growth factor-β1 (TGF-β1) was borderline significantly associated with PPCs (P=.087). Patients with PPCs had significantly larger pre-CCRT to post-CCRT decrease in serum TGF-β1 concentration (−11,310 vs −5332 pg/mL, P=.005) and higher pre-CCRT to post-CCRT percent decline in serum TGF-β1 concentration (−37.4% vs −25.0%, P=.009) than patients without PPCs. On multivariate analysis, preoperative FVC (P=.003) and decrease in TGF-β1 >7040 pg/mL (P=.014) were independent factors associated with PPCs. Conclusions: Preoperative FVC and decrease in serum TGF-β1 level after dose-limited CCRT to the lung are associated with the development of PPCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noninvasive Assessment of Right Ventricular Function in Patients with Pulmonary Arterial Hypertension and Left Ventricular Assist Device

Purpose of Review: Right ventricular (RV) failure in patients with pulmonary arterial hypertension (PAH) and left ventricular assist device (LVAD) is associated with increased hospitalizations, worsening functional class, and poor survival. Accurate RV function assessment is essential in diagnosing RV failure, guiding therapies, and determining prognosis. Noninvasive imaging techniques provide fast and reliable quantification of RV morphology and function. Recent Findings: We review echocardiography, nuclear medicine, and cardiac magnetic resonance imaging (MRI) uses for RV function assessment in patients with PAH and LVAD. We identify current knowledge gaps in utilizing noninvasive tests to assess RV function. Summary: Echocardiography is most widely used to quantify RV function in patients with PAH and LVAD, followed by cardiac MRI for RV morphology and function measurement in PAH patients. The first-pass radionuclide angiography with radiolabeled RBC is the gold standard for calculating RV function. Gated blood pool SPECT can be an alternative as it separates the cardiac chambers well and provides accurate assessment of the RV function with high reproducibility, which is particularly useful for monitoring treatment. More research is needed to compare and validate these modalities in evaluating RV function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting 3D Motions from Single-Camera Optical Test Data

In a typical optical test, a stereo camera pair is required to measure the three-dimensional motion of a test article; one camera typically only measures motions in the image plane of the camera, and measurements in the out-of-plane direction are missing. Finite element expansion techniques provide a path to estimate responses from a test at unmeasured degrees of freedom. Treating the case of a single camera as a measurement with unmeasured degrees of freedom, a finite element model is used to expand to the missing third dimension of the image data, allowing a full-field, three-dimensional measurement to be obtained from a set of images from a single camera. The key to this technique relies on the mapping of finite element deformations to image deformations, creating a set of mode shape images that are used to filter the response in the image into modal responses. These modal responses are then applied to the finite element model to estimate physical responses at all finite element model degrees of freedom. The mapping from finite element model to image is achieved using synthetic images produced by a rendering software. Finally, the technique is applied first to a synthetic deformation image, and then is validated using an experimental set of images.

47 OTHER INSTRUMENTATION↗

Comparison study of the partial-breast irradiation techniques: Dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations

The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dose homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Unsteady design-point flow phenomena in transonic compressors

High-frequency response probes which had previously been used exclusively in the MIT Blowndown Facility were successfully employed in two conventional steady state axial flow compressor facilities to investigate the unsteady flowfields of highly loaded transonic compressors at design point operation. Laser anemometry measurements taken simultaneously with the high response data were also analyzed. The time averaged high response data of static and total pressure agreed quite well with the conventional steady state instrumentation except for flow angle which showed a large spread in values at all radii regardless of the type of instrumentation used. In addition, the time resolved measurements confirmed earlier test results obtained in the MIT Blowdown Facility for the same compressor. The results of these tests have further revealed that the flowfields of highly loaded transonic compressors are heavily influenced by unsteady flow phenomena. The high response measurements exhibited large variations in the blade to blade flow and in the blade passage flow. The observed unsteadiness in the blade wakes is explained in terms of the rotor blades' shed vorticity in periodic vortex streets. The wakes were modeled as two-dimensional vortex streets with finite size cores. The model fit the data quite well as it was able to reproduce the average wake shape and bi-modal probability density distributions seen in the laser anemometry data. The presence of vortex streets in the blade wakes also explains the large blade to blade fluctuations seen by the high response probes which is simply due to the intermittent sampling of the vortex street as it is swept past a stationary probe.

Gertz, J. B.↗

Clarissa Spoken Dialogue System for Procedure Reading and Navigation

Speech is the most natural modality for humans use to communicate with other people, agents and complex systems. A spoken dialogue system must be robust to noise and able to mimic human conversational behavior, like correcting misunderstandings, answering simple questions about the task and understanding most well formed inquiries or commands. The system aims to understand the meaning of the human utterance, and if it does not, then it discards the utterance as being meant for someone else. The first operational system is Clarissa, a conversational procedure reader and navigator, which will be used in a System Development Test Objective (SDTO) on the International Space Station (ISS) during Expedition 10. In the present environment one astronaut reads the procedure on a Manual Procedure Viewer (MPV) or paper, and has to stop to read or turn pages, shifting focus from the task. Clarissa is designed to read and navigate ISS procedures entirely with speech, while the astronaut has his eyes and hands engaged in performing the task. The system also provides an MPV like graphical interface so the procedure can be read visually. A demo of the system will be given.

Hieronymus, James↗

Blunt-Body Paradox and Improved Application of Transient-Growth Framework

The “Reshotko-Tumin transition criterion" based on optimal transient growth successfully correlates laboratory measurements of roughness induced transition over blunt body configurations. Even though transient growth has not been conclusively linked to the measured onset of transition, the above correlation denotes the only available physics-based model for subcritical transition in blunt body flows, since the latter do not support any modal instabilities at typical experimental conditions. Unlike other established models based on empirical curve fits that are valid for a specific subclass of datasets, the optimal-growth-based transition criterion appears to provide a reasonable correlation with measurements in various wind tunnel and ballistic range facilities and for a broad range of surface temperature ratios. This paper is focused on optimal growth calculations that improve upon significant shortcomings of the computations underlying the Reshotko-Tumin correlation. The improved framework is applied to leeward transition over a spherical section forebody that was tested in the Mach 6 Adjustable Contour Expansion wind tunnel at Texas A&M University. The computed results highlight the significance of nonparallel basic state evolution, curvature terms, and an optimization procedure that varies both inflow and outflow locations of the transient growth interval. More important, the results indicate that the modified correlation is very close to its original form, and hence, that the accuracy of the transient-growth-based transition criterion is not compromised by using a more thorough theoretical framework. Yet the results also show that the optimal energy gain up to the predicted transition onset location can be rather small, highlighting the need to further investigate the optimal growth criterion for additional experimental configurations and to also uncover the in-depth physics underlying blunt body transition.

Freestream conditions↗

Experimental Studies on the Effect of Impact Processes on the Formation and Evolution of Amino Acids

Introduction: A critical step in the emergence of life on Earth was the synthesis of larger organic molecules from simple building blocks such as NH3, CO2, H2O, and CH3OH. The presence of amino acids and other complex organics in comets and meteorites demonstrates that widespread organic synthesis likely occurred across the early solar system. Building on previous work [e.g., 1-3], we systematically explore impact-driven chemical evolution of exogenous organics and their precursors. Collisional processes may also have provided a source of energy for the formation of more complex organics from endogenous building blocks. The high flux of impactors to Earth immediately prior to and during the origins of life suggests that impacts could have played a critical role. Key Questions: 1. How are the formation and evolution of amino acids affected by the presence of a mineral matrix during cometary and asteroidal impacts onto the early Earth? 2. Do some minerals (e.g., phyllosilicates) provide a more robust protective framework or reactive surface site for amino-acid formation and/or polymerization? 3. Does the abundance of ices and/or amino acids relative to that of the mineral matrix affect the formation and evolution of amino acids? 4. Are there impact velocities/shock pressures at which formation or polymerization of amino acids is favored or precluded? Experimental Approach: This study systematically examines the conditions under which amino acids and other organic molecules can form, be polymerized, and/or be destroyed during impact events into particulate regolith simulants. Variable parameters include the modal composition of this regolith (silicate matrices, ratios of ices, silicates, and amino acids) and impact velocities/shock pressures. Impacts experiments were performed using the two-stage light-gas gun (LGG), vertical gun (VG), and flat-plate accelerator (FPA) in the Experimental Impact Lab at JSC. FPA experiments were performed over a range of shock pressures (11.3-31.5 GPa) using CM chondrite simulant mixed with amino acids at ratios of 0:10, 1:10, 1:103, and 1:106 (amino acid:host). Techniques for mixing cometary ices have been optimized and test runs have been performed using the LGG (see figure below). Analysis: Post-impact, samples are heated in water to extract amino acids and peptides. Extracts are characterized via liquid chromatography-mass spectrometry (LC-MS) and the mineralogies of solid residues are characterized using X-ray diffraction, scanning electron microscopy and transmission electron microscopy. Additional LC-MS and mineralogical analyses are underway.

Eve L Berger↗

Subsystem Estimation: A Modal Decomposition Approach

In structural analysis it is often the requirement that the response of a critical subsystem must be extracted from the response of the overall structure even when not directly excited or sometimes even measured. Based on this requirement, a number of signal processing approaches evolve that can provide a meaningful solution to this troubling problem; however, there is a variety of prior information (parameters or data) that must be available. For instance, knowledge of subsystem bandwidth may be enough to design a simple filter if there is little or no overlap with other component systems. If this is not satisfactory and a specific spectral response is required, then a model-based approach can be applied using an available free-free response of the subsystem from calibration or acceptance tests. However, when assembled and coupled with the overall system, the subsystem boundary conditions have been altered and therefore its response is altered as well.

42 ENGINEERING↗

Dynamic modeling of structures from measured complex modes

A technique is presented to use a set of identified complex modes together with an analytical mathematical model of a structure under test to compute improved mass, stiffness and damping matrices. A set of identified normal modes, computed from the measured complex modes, is used in the mass orthogonality equation to compute an improved mass matrix. This eliminates possible errors that may result from using approximated complex modes as normal modes. The improved mass matrix, the measured complex modes and the higher analytical modes are then used to compute the improved stiffness and damping matrices. The number of degrees-of-freedom of the improved model is limited to equal the number of elements in the measured modal vectors. A simulated experiment shows considerable improvements, in the system's analytical dynamic model, over the frequency range of the given measured modal information.

Ibrahim, s. R.↗

Dynamic Modeling of Structures from Measured Complex Modes

A technique is presented to use a set of identified complex modes together with an analytical mathematical model of a structure under test to compute improved mass, stiffness and damping matrices. A set of identified normal modes, computed from the measured complex modes, is used in the mass orthogonality equation to compute an improved mass matrix. This eliminates possible errors that may result from using approximated complex modes as normal modes. The improved mass matrix, the measured complex modes and the higher analytical modes are then used to compute the improved stiffness and damping matrices. The number of degrees-of-freedom of the improved model is limited to equal the number of elements in the measured modal vectors. A simulated experiment shows considerable improvements, in the system's analytical dynamic model, over the frequency range of the given measured modal information.

Ibrahim, S. R.↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

Wide-Area Measurement-Based Modal Decoupling for Power System Oscillation Damping

Inter-area oscillation modes usually fall within the same frequency range of 0.1 to 1.0 Hz; thus, power oscillation damping (POD) control methods should avoid unnecessary excitation of weakly damped modes. This paper presents a decoupled control strategy to damp inter-area oscillations in the power grid. Pure oscillation mode signals are extracted from wide-area measurements and used as feedback input for POD actuators such as power system stabilizers or high-voltage direct current transmission. The decoupled control strategy is able to increase the damping of the concerned oscillation modes without deteriorating others. This proposed strategy could be implemented independently, or serve as a complement and work along with conventional POD controllers to damp concerned inter-area modes. The proposed method has been tested on a modied MinniWECC system. Extensive results indicate that inter-area oscillations can be successfully and precisely damped using the proposed decoupled strategy.

Fan, Rui↗

Quality Assurance for the Geometric Accuracy of Cone-Beam CT Guidance in Radiation Therapy

The introduction of volumetric X-ray image-guided radiotherapy systems allows improved management of geometric variations in patient setup and internal organ motion. As these systems become a routine clinical modality, we propose a daily quality assurance (QA) program for cone-beam computed tomography (CBCT) integrated with a linear accelerator. The image-guided system used in this work combines a linear accelerator with conventional X-ray tube and an amorphous silicon flat-panel detector mounted orthogonally from the accelerator central beam axis. This article focuses on daily QA protocols germane to geometric accuracy of the CBCT systems and proposes tolerance levels on the basis of more than 3 years of experience with seven CBCT systems used in our clinic. Monthly geometric calibration tests demonstrate the long-term stability of the flex movements, which are reproducible within {+-}0.5 mm (95% confidence interval). The daily QA procedure demonstrates that, for rigid phantoms, the accuracy of the image-guided process can be within 1 mm on average, with a 99% confidence interval of {+-}2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

QA for helical tomotherapy: Report of the AAPM Task Group 148

Helical tomotherapy is a relatively new modality with integrated treatment planning and delivery hardware for radiation therapy treatments. In view of the uniqueness of the hardware design of the helical tomotherapy unit and its implications in routine quality assurance, the Therapy Physics Committee of the American Association of Physicists in Medicine commissioned Task Group 148 to review this modality and make recommendations for quality assurance related methodologies. The specific objectives of this Task Group are: (a) To discuss quality assurance techniques, frequencies, and tolerances and (b) discuss dosimetric verification techniques applicable to this unit. This report summarizes the findings of the Task Group and aims to provide the practicing clinical medical physicist with the insight into the technology that is necessary to establish an independent and comprehensive quality assurance program for a helical tomotherapy unit. The emphasis of the report is to describe the rationale for the proposed QA program and to provide example tests that can be performed, drawing from the collective experience of the task group members and the published literature. It is expected that as technology continues to evolve, so will the test procedures that may be used in the future to perform comprehensive quality assurance for helical tomotherapy units.

61 RADIATION PROTECTION AND DOSIMETRY↗

Versatile & Intelligent Biodetection via Environmental Sensing (VIBES)

Reactive health monitoring strategies during events like the COVID-19 pandemic highlighted the need for predictive, threat-agnostic diagnostics that can detect both known diseases and novel chemical or biological threats. To address this, we investigated an optical biosensor as a breath volatile organic compound (VOC) analyzer, aiming to emulate biological olfaction. We assembled and validated the device with thin film metal coated substrate-based sensors. We immobilized small biological recognition elements on the substrates and delivered controlled concentrations of target VOCs. The sensor was irradiated with a visible laser and the sensor signal was recorded. We characterized the laser performance and tested 3 recognition elements for 2 VOCs with varying concentrations (1-100 ppm). We also evaluated enhancement of the signal using nanostructures on the metal film in comparison with planar film substrate. We demonstrated detecting ethanol reliably at concentrations as low as ~2 ppm along with preliminary detection of acetone (<100 ppm). We also found several unexpected factors that influence the sensor behavior that should be addressed to further refine the device’s performance. The nanostructures were, as expected, found to amplify the sensor signals. These findings demonstrate the feasibility of the optical bio-sensing modality for breath VOC monitoring at physiologically relevant levels. This positions LLNL to develop a low-cost, scalable, broad-spectrum health monitoring capability aligned with the Early Detection thrust of the Bioresilience Mission Focus Area and attract external funding.

47 OTHER INSTRUMENTATION↗

Adaptive Strategies for Controls of Flexible Arms

An adaptive controller for a modern manipulator has been designed based on asymptotical stability via the Lyapunov criterion with the output error between the system and a reference model used as the actuating control signal. Computer simulations were carried out to test the design. The combination of the adaptive controller and a system vibration and mode shape estimator show that the flexible arm should move along a pre-defined trajectory with high-speed motion and fast vibration setting time. An existing computer-controlled prototype two link manipulator, RALF (Robotic Arm, Large Flexible), with a parallel mechanism driven by hydraulic actuators was used to verify the mathematical analysis. The experimental results illustrate that assumed modes found from finite element techniques can be used to derive the equations of motion with acceptable accuracy. The robust adaptive (modal) control is implemented to compensate for unmodelled modes and nonlinearities and is compared with the joint feedback control in additional experiments. Preliminary results show promise for the experimental control algorithm.

Yuan, Bau-San↗