Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Electrical substation grid testbed for DLT applications of electrical fault detection, power quality monitoring, DERs use cases and cyber-events

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation, and are associated with customer-owned distributed energy resources (DERs). The integrity and confidentiality of data from these IEDs, like power meters and protective relays, is crucial. Blockchain technology could improve the resilience of microgrids by improving the security of data sharing. The penetration of customer-owned DERs (renewable energy sources) and the increasing deployment of IEDs can lead to integrate power system applications with Distributed Ledger Technology (DLT). In this study, we implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in-the-loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results had shown the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, the ESGT with DERs and the CGG system will be used in other power system applications, based on implementing smart contracts between electrical utilities with customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stainless Steel NaK-Cooled Circuit (SNaKC) Fabrication and Assembly

An actively pumped Stainless Steel NaK Circuit (SNaKC) has been designed and fabricated by the Early Flight Fission Test Facility (EFF-TF) team at NASA's Marshall Space Flight Center. This circuit uses the eutectic mixture of sodium and potassium (NaK) as the working fluid building upon the experience and accomplishments of the SNAP reactor program from the late 1960's The SNaKC enables valuable experience and liquid metal test capability to be gained toward the goal of designing and building an affordable surface power reactor. The basic circuit components include a simulated reactor core a NaK to gas heat exchanger, an electromagnetic (EM) liquid metal pump, a liquid metal flow meter, an expansion reservoir and a drain/fill reservoir To maintain an oxygen free environment in the presence of NaK, an argon system is utilized. A helium and nitrogen system are utilized for core, pump, and heat exchanger operation. An additional rest section is available to enable special component testing m an elevated temperature actively pumped liquid metal environment. This paper summarizes the physical build of the SNaKC the gas and pressurization systems, vacuum systems, as well as instrumentation and control methods.

Godfroy, Thomas J.↗

Electrical Fault and Power Quality Detection Algorithms and Customer-Owned DERs Monitoring with a Cyber Grid Guard System and DLT

In this study, the electrical fault and power quality detection algorithms and customer-owned DERs monitoring use cases were implemented, with a Cyber Grid Guard system and DLT. Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substations, and are associated with customer-owned distributed energy resources (DERs). Data from these IEDs, such as power meters and protection relays, must be kept confidential and of high integrity. Blockchain technology has the potential to increase microgrid resilience by enhancing data sharing security. The growing use of IEDs and customer-owned renewable energy sources (DERs) may make it necessary to connect Distributed Ledger Technology (DLT) with power system applications. We implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in the loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results showed the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, power system applications for the ESGT with DERs and the CGG system will be based on executing smart contracts between electrical utilities and customer-owned DERs.

Piesciorovsky, Emilio↗

Static aerodynamic characteristics of a 0.035-scale model of a modified NKC-135 airplane at a Mach number of 0.28

A 0.035-scale model fo a modified NKC-135 airplane was tested in 12-foot pressure wind tunnel to determine the effects on the static aerodynamic characteristics of modifications to the basic aircraft. Modifications investigated included: nose, lower fuselage, and upper fuselage radomes; wing pylons and pods; overwing probe; and air conditioning inlets. The investigation was performed at a Mach number of 0.28 over a Reynolds number range from 6.6 to 26.2 million per meter. Angles of attack and sideslip varied from -8 deg to 20 deg and from -18 deg to 8 deg, respectively, for various combinations of flap, aileron, and rudder deflections. A limited analysis of the test results indicates that the addition of the radomes reduces lateral-directional stability and control effectiveness of the basic aircraft.

Hedstrom, E.↗

Development of a Large Scale, High Speed Wheel Test Facility

Draper Laboratory, with its internal research and development budget, has for the past two years been funding a joint effort with the Massachusetts Institute of Technology (MIT) for the development of a large scale, high speed wheel test facility. This facility was developed to perform experiments and carry out evaluations on levitation and propulsion designs for MagLev systems currently under consideration. The facility was developed to rotate a large (2 meter) wheel which could operate with peripheral speeds of greater than 100 meters/second. The rim of the wheel was constructed of a non-magnetic, non-conductive composite material to avoid the generation of errors from spurious forces. A sensor package containing a multi-axis force and torque sensor mounted to the base of the station, provides a signal of the lift and drag forces on the package being tested. Position tables mounted on the station allow for the introduction of errors in real time. A computer controlled data acquisition system was developed around a Macintosh IIfx to record the test data and control the speed of the wheel. This paper describes the development of this test facility. A detailed description of the major components is presented. Recently completed tests carried out on a novel Electrodynamic (EDS) suspension system, developed by MIT as part of this joint effort are described and presented. Adaptation of this facility for linear motor and other propulsion and levitation testing is described.

Kondoleon, Anthony↗

Note: A real-time beam current density meter

We have developed a real-time beam current density meter for charged particle beams. It measures the mean current density by collimating a uniform and large diameter primary beam. The suppression of the secondary electrons and the deflection of the beam were simulated, and it was tested with a 105 keV Ar{sup 7+} ion beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Air Traffic Management Technology Demostration: 1 Research and Procedural Testing of Routes

NASA's Air Traffic Management Technology Demonstration-1 (ATD-1) will operationally demonstrate the feasibility of efficient arrival operations combining ground-based and airborne NASA technologies. The ATD-1 integrated system consists of the Traffic Management Advisor with Terminal Metering which generates precise time-based schedules to the runway and merge points; Controller Managed Spacing decision support tools which provide controllers with speed advisories and other information needed to meet the schedule; and Flight deck-based Interval Management avionics and procedures which allow flight crews to adjust their speed to achieve precise relative spacing. Initial studies identified air-ground challenges related to the integration of these three scheduling and spacing technologies, and NASA's airborne spacing algorithm was modified to address some of these challenges. The Research and Procedural Testing of Routes human-in-the-loop experiment was then conducted to assess the performance of the new spacing algorithm. The results of this experiment indicate that the algorithm performed as designed, and the pilot participants found the airborne spacing concept, air-ground procedures, and crew interface to be acceptable. However, the researchers concluded that the data revealed issues with the frequency of speed changes and speed reversals.

Wilson, Sara R.↗

Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions

Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.

thermal controls↗

Planning fuel-conservative descents in an airline environmental using a small programmable calculator: Algorithm development and flight test results

A simple, airborne, flight-management descent algorithm was developed and programmed into a small programmable calculator. The algorithm may be operated in either a time mode or speed mode. The time mode was designed to aid the pilot in planning and executing a fuel-conservative descent to arrive at a metering fix at a time designated by the air traffic control system. The speed model was designed for planning fuel-conservative descents when time is not a consideration. The descent path for both modes was calculated for a constant with considerations given for the descent Mach/airspeed schedule, gross weight, wind, wind gradient, and nonstandard temperature effects. Flight tests, using the algorithm on the programmable calculator, showed that the open-loop guidance could be useful to airline flight crews for planning and executing fuel-conservative descents.

Knox, C. E.↗

Recover Act. Verification of Geothermal Tracer Methods in Highly Constrained Field Experiments

The prediction of the geothermal system efficiency is strong linked to the character of the flow system that connects injector and producer wells. If water flow develops channels or “short circuiting” between injection and extraction wells thermal sweep is poor and much of the reservoir is left untapped. The purpose of this project was to understand how channelized flow develops in fracture geothermal reservoirs and how it can be measured in the field. We explored two methods of assessing channelization: hydraulic connectivity tests and tracer tests. These methods were tested at a field site using two verification methods: ground penetrating radar (GPR) images of saline tracer and heat transfer measurements using distributed temperature sensing (DTS). The field site for these studies was the Altona Flat Fractured Rock Research Site located in northeastern New York State. Altona Flat Rock is an experimental site considered a geologic analog for some geothermal reservoirs given its low matrix porosity. Because soil overburden is thin, it provided unique access to saturated bedrock fractures and the ability image using GPR which does not effectively penetrate most soils. Five boreholes were drilled in a “five spot” pattern covering 100 m2 and hydraulically isolated in a single bedding plane fracture. This simple system allowed a complete characterization of the fracture. Nine small diameter boreholes were drilled from the surface to just above the fracture to allow the measurement of heat transfer between the fracture and the rock matrix. The focus of the hydraulic investigation was periodic hydraulic testing. In such tests, rather than pumping or injection in a well at a constant rate, flow is varied to produce an oscillating pressure signal. This pressure signal is sensed in other wells and the attenuation and phase lag between the source and receptor is an indication of hydraulic connection. We found that these tests were much more effective than constant pumping tests in identifying a poorly connected well. As a result, we were able to predict which well pairs would demonstrate channelized flow. The focus of the tracer investigation was multi-ionic tests. In multi-ionic tests several ionic tracers are injected simultaneously and the detected in a nearby pumping well. The time history of concentration, or breakthrough curve, will show a separation of the tracers. Anionic tracers travel with the water but cationic tracer undergo chemical exchange with cations on the surface of the rock. The degree of separation is indicative of the surface area exposed to the tracer. Consequently, flow channelization will tend to decrease the separation in the breakthrough. Estimation of specific surface area (the ration of fracture surface area to formation volume) is performed through matching the breakthrough curve with a transport model. We found that the tracer estimates of surface area were confirmed the prediction of channelized flow between well pairs produced by the periodic hydraulic tests. To confirm that the hydraulic and tracer tests were correctly predicting channelize flow, we imaged the flow field using surface GPR. Saline water was injected between the well pairs which produced a change in the amplitude and phase of the reflected radar signal. A map was produced of the migration of saline tracer from these tests which qualitatively confirmed the flow channelization predicted by the hydraulic and tracer tests. The resolution of the GPR was insufficient to quantitatively estimate swept surface area, however. Surface GPR is not applicable in typical geothermal fields because the penetration depths do not exceed 10’s of meters. Nevertheless, the method of using of phase to measure electrical conductivity and the assessment of antennae polarization represent a significant advancement in the field of surface GPR. The effect of flow character on fracture / rock thermal exchange was evaluated using heated water as a tracer. Water elevated 30 degrees C above the formation water was circulated between two wells pairs. One well pair had been identified in hydraulic and tracer testing as well connected and the other poorly connected. Temperature rise was measured in the adjacent rock matrix using coiled fiber optic cable interrogated for temperature using a DTS. This experimental design produced over 4000 temperature measurements every hour. We found that heat transfer between the fracture and the rock matrix was highly impacted by the character of the flow field. The strongly connected wells which had demonstrated flow channelization produced heat rise in a much more limited area than the more poorly connected wells. In addition, the heat increase followed the natural permeability of the fracture rather than the induced flow field. The primary findings of this work are (1) even in a single relatively planar fracture, the flow field can be highly heterogeneous and exhibit flow channeling, (2) channeling results from a combination of fracture permeability structure and the induced flow field, and (3) flow channeling leads to reduced heat transfer. Multi-ionic tracers effectively estimate relative surface area but an estimate of ion-exchange coefficients are necessary to provide an absolute measure of specific surface area. Periodic hydraulic tests also proved a relative indicator of connectivity but cannot prove an absolute measure of specific surface area.

15 GEOTHERMAL ENERGY↗

Design, Development, and Operation of an Integrated Fluidized Carbon Capture Unit Using Polyethylenimine Sorbents

In this paper, we present the design, development, and operation of a reactor system for CO 2 capture. Modifications were implemented to address differences in sorbent from 180 μm Geldart group B to 115 μm Geldart group A material; operational issues were discovered during experimental trials. The major obstacle in system operation was the ability to maintain a constant circulation of a solid sorbent stemming from this change in sorbent material. The system consisted of four fluid beds, through which a polyamine impregnated sorbent was circulated and adsorption, preheat, regeneration, and cooling processes occurred. Pressure transducers, thermocouples, gas flow meters, and gas composition instrumentation were used to characterize thermal, hydrodynamic, and gas adsorption performance in this integrated unit. A series of shakedown tests were performed and the configuration altered to meet the needs of the sorbent performance and achieve desired target capture efficiencies. Methods were identified, tested, and applied to continuously monitor critical operating parameters including solids circulation rate, adsorbed and desorbed CO 2 , solids inventories, and pressures. The working capacity and CO 2 capture efficiency were used to assess sorbent performance while CO 2 closure was used to define data quality and approach to steady-state. Testing demonstrated >90% capture efficiencies and identified the regenerator to be the process step limiting throughput. Sorbent performance was found to be related to the reactant stoichiometry. Finally, a stochastic model with an exponential dependence on the relative CO 2 /amine concentration was used to describe 90% of the variance in the data.

01 COAL, LIGNITE, AND PEAT↗

Leaf gas exchange, spectral reflectance and leaf composition, BIONTE, Brazil, 2022

Leaf traits measured at the top of the canopy on 10 species at the BIONTE experimental plot T1B4SB3, near Manaus, Brazil, in August and September, 2022. The aim of this study was to test the relationship between leaf water use efficiency and wood density. Ten tree species located in close proximity of each other (within 50 meters) were selected and classified by wood density (low or high). Sampling was carried out on top-of-canopy leaves accessed by an articulated boom lift. Survey gas exchange measurement were performed on attached leaves at various times during the day. Following gas exchange, the leaf was harvested, and measured for spectral reflectance, leaf water content, leaf mass per area and leaf carbon content and leaf nitrogen content. Additional leaves other than those used for gas exchange were also harvested from different branches on the same tree for spectral reflectance and leaf trait measurements. Data in this data package is presented in csv files, with metadata in csv and descriptive experimental protocols as pdf. Gas exchange data and metadata meets the requirements of the ESS-DIVE reporting format for leaf gas exchange data and metadata.

54 ENVIRONMENTAL SCIENCES↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

corrosion↗

Hot-gas-side heat transfer with and without film cooling on a simulated nuclear rocket thrust chamber using H2-O2

Heat-transfer coefficients were obtained on a thrust chamber which simulated the geometry of the NERVA nuclear rocket. The tests were performed with and without peripheral film cooling over a chamber pressure range of 1.05 million to 5.84 million newtons per square meter (153 to 847 psia). With no film cooling, the overall axial variation in the value of the correlation coefficient C of the equation (Stanton)* (Prandtl)* to the 0.7ths power = C(Reynolds)* to the -0.2ths power, where * indicates the reference enthalpy condition, was reduced 66 percent when the local diameter in the Reynolds number was replaced by the axial distance from the injector face. The average peak values of C were reduced 25 percent with 2 and 3.75 percent cooling and 50 percent with 7.5 percent cooling.

Quentmeyer, R. J.↗

Updating coastal and navigational charts using ERTS-1 data

A successful processing algorithm for extracting water depth information from ERTS data has been developed. Depth charts for two geographical areas have been constructed representing different solar illumination and water transparency conditions. Absolute depth calculations for water depth to 4.5 fathoms have been demonstrated for the Little Bahama Bank. Depth Charts also were constructed using data in Band 4 and 5 of the ERTS-1 MSS for areas in Lake Michigan. This data represented a low sun angle, poor light transmission in water conditions and gave useful results to 200 meters. In both cases, the ERTS map represented an update in shallow water detail in comparison with available navigation charts for the areas tested. Present processing costs to provide MSS depth charts are estimated to be on the order of $1.50 per sq. mile. The updating of navigation charts for areas hazardous to shipping is an achievable direct application.

Polcyn, F. C.↗

Lee surface flow phenomena over space shuttle at large angles of attack at M sub infinity equal 6

Surface pressure and heat transfer, flow separation, flow field, and oil flow patterns on the leeward side of a space shuttle orbiter model are investigated at a free stream Mach number of 6. The free stream Reynolds numbers are between 1.64 times 10 to the 7th power and 1.31 times 10 to the 8th power per meter, and the angle of attack is varied between 0 deg and 40 deg for the present experiments. The stagnation temperatures for the tests are approximately 500 K and the wall temperature is maintained at 290 K. Existing numerical methods of three-dimensional inviscid supersonic flow theory and compressible boundary layer theory are used to predict the present experimental measurements. Results of the present tests indicate two distinct types of flow separation and surface peak heating depending on the angle of attack.

Zakkay, V.↗

Unsteady fan blade pressure and acoustic radiation from a JT15D-1 turbofan engine at simulated forward speed

Tests have been conducted on a JT15D-1 turbofan engine both statically and at simulated forward speed in the Ames 12 x 24 Meter Wind Tunnel. Both far-field acoustic data and unsteady pressure data from transducers mounted on the fan blades were acquired. Results showed a sound power reduction of about 10 dB in the far-field acoustic levels with simulated forward speed over those measured without forward speed. Blade mounted transducer results showed rotor-turbulence interaction dominated the noise field at very low speeds while an interaction between the rotor and internal struts dominated at higher speeds. Results are presented to show the effects of varying engine rpm, changing the angle-of-attack of the engine inlet to tunnel flow and mounting an aircraft wing to simulate an installation condition on an actual aircraft.

Preisser, J. S.↗

Improved ranging systems

Spacecraft range measurements have provided the most accurate tests, to date, of some relativistic gravitational parameters, even though the measurements were made with ranging systems having error budgets of about 10 meters. Technology is now available to allow an improvement of two orders of magnitude in the accuracy of spacecraft ranging. The largest gains in accuracy result from the replacement of unstable analog components with high speed digital circuits having precisely known delays and phase shifts.

Young, Larry E.↗