Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Direction indicator system does not require complicated optics

Direction indicator which aligns a system relative to a light source uses two photocells as light sensors to form a set. Each set indicates one direction. This indicator has no moving parts and provides very fine vernier acquisition.

Mildice, J. W.↗

Pulse transducer with artifact signal attenuator

An artifact signal attenuator for a pulse rate sensor is described. The circuit for attenuating background noise signals is connected with a pulse rate transducer which has a light source and a detector for light reflected from blood vessels of a living body. The heart signal provided consists of a modulated dc signal voltage indicative of pulse rate. The artifact signal resulting from light reflected from the skin of the body comprises both a constant dc signal voltage and a modulated dc signal voltage. The amplitude of the artifact signal is greater and the frequency less than that of the heart signal. The signal attenuator circuit includes an operational amplifier for canceling the artifact signal from the output signal of the transducer and has the capability of meeting packaging requirements for wrist-watch-size packages.

Cash, W. H., Jr.↗

High efficiency environmental sampling with rapidly cured peelable coatings

A rapidly curable liquid gel for collecting an analyte from a sampling surface includes a polymer precursor mixture including a monomer and/or an oligomer; and an additive to enhance extraction of the analyte from the sampling surface. A kit for collecting an analyte from a sampling surface may include the rapidly curable liquid gel and a portable device for rapidly curing the gel. The rapidly curable liquid gel is cured to thereby form a peelable sampling film, and the sampling film is removed from the sampling surface, thereby collecting the analyte. In one embodiment, the rapidly curable liquid gel is UV-curable, the polymer precursor mixture further includes a photoinitiator compound, and the portable device includes a UV light source configured to emit UV light of a wavelength range absorbed by the photoinitiator compound.

Henzl, Vladimir↗

Photonic integrated circuits for generating high-brightness squeezed light

A high-brightness squeezed light source includes a plurality of light squeezing elements and a photonic summing device. The light squeezing elements each output respective squeezed light responsive to receipt of unsqueezed light. The photonic summing device receives the squeezed light output by each of the light squeezing elements and coherently adds the squeezed light to generate a high-brightness squeezed light output. The high-brightness squeezed light output has a greater brightness than the outputs of the light squeezing elements, and a same degree of squeezing as one or more of the outputs of the light squeezing elements.

Soh, Daniel Beom Soo↗

New Homogeneous Standards by Atomic Layer Deposition for Synchrotron X-ray Fluorescence and Absorption Spectroscopies.

Quantification of synchrotron XRF analyses is typically done through comparisons with measurements on the NIST SRM 1832/1833 thin film standards. Unfortunately, these standards are inhomogeneous on small scales at the tens of percent level. We are synthesizing new homogeneous multilayer standards using the Atomic Layer Deposition technique and characterizing them using multiple analytical methods, including ellipsometry, Rutherford Back Scattering at Evans Analytical, Synchrotron X-ray Fluorescence (SXRF) at Advanced Photon Source (APS) Beamline 13-ID, Synchrotron X-ray Absorption Spectroscopy (XAS) at Advanced Light Source (ALS) Beamlines 11.0.2 and 5.3.2.1 and by electron microscopy techniques. Our motivation for developing much-needed cross-calibration of synchrotron techniques is borne from coordinated analyses of particles captured in the aerogel of the NASA Stardust Interstellar Dust Collector (SIDC). The Stardust Interstellar Dust Preliminary Examination (ISPE) team have characterized three sub-nanogram, {approx}1{micro}m-sized fragments considered as candidates to be the first contemporary interstellar dust ever collected, based on their chemistries and trajectories. The candidates were analyzed in small wedges of aerogel in which they were extracted from the larger collector, using high sensitivity, high spatial resolution >3 keV synchrotron x-ray fluorescence spectroscopy (SXRF) and <2 keV synchrotron x-ray transmission microscopy (STXM) during Stardust ISPE. The ISPE synchrotron techniques have complementary capabilities. Hard X-ray SXRF is sensitive to sub-fg mass of elements Z {ge} 20 (calcium) and has a spatial resolution as low as 90nm. X-ray Diffraction data were collected simultaneously with SXRF data. Soft X-ray STXM at ALS beamline 11.0.2 can detect fg-mass of most elements, including cosmochemically important oxygen, magnesium, aluminum and silicon, which are invisible to SXRF in this application. ALS beamline 11.0.2 has spatial resolution better than 25 nm. Limiting factors for Stardust STXM analyses were self-imposed limits of photon dose due to radiation damage concerns, and significant attenuation of <1500 eV X-rays by {approx}80{micro}m thick, {approx}25 mg/cm{sup 3} density silica aerogel capture medium. In practice, the ISPE team characterized the major, light elements using STXM (O, Mg, Al, Si) and the heavier minor and trace elements using SXRF. The two data sets overlapped only with minor Fe and Ni ({approx}1% mass abundance), providing few quantitative cross-checks. New improved standards for cross calibration are essential for consortium-based analyses of Stardust interstellar and cometary particles, IDPs. Indeed, they have far reaching application across the whole synchrotron-based analytical community. We have synthesized three ALD multilayers simultaneously on silicon nitride membranes and silicon and characterized them using RBS (on Si), XRF (on Si{sub 3}N{sub 4}) and STXM/XAS (holey Si{sub 3}N{sub 4}). The systems we have started to work with are Al-Zn-Fe and Y-Mg-Er. We have found these ALD multi-layers to be uniform at {micro}m- to nm scales, and have found excellent consistency between four analytical techniques so far. The ALD films can also be used as a standard for e-beam instruments, eg., TEM EELS or EDX. After some early issues with the consistency of coatings to the back-side of the membrane windows, we are confident to be able to show multi-analytical agreement to within 10%. As the precision improves, we can use the new standards to verify or improve the tabulated cross-sections.

43 PARTICLE ACCELERATORS↗

Numerical evaluation of a 13.5-nm high-brightness microplasma extreme ultraviolet source

The extreme ultraviolet (EUV) emission and its spatial distribution as well as plasma parameters in a microplasma high-brightness light source are characterized by the use of a two-dimensional radiation hydrodynamic simulation. The expected EUV source size, which is determined by the expansion of the microplasma due to hydrodynamic motion, was evaluated to be 16 μm (full width) and was almost reproduced by the experimental result which showed an emission source diameter of 18–20 μm at a laser pulse duration of 150 ps [full width at half-maximum]. The numerical simulation suggests that high brightness EUV sources should be produced by use of a dot target based microplasma with a source diameter of about 20 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solid-State Lighting on a Shoestring Budget: The Economics of Off-Grid Lighting for Small Businesses in Kenya

superior lighting services to low income people in off-grid areas of developing countries, many of whom currently rely on fuel based lighting sources such as kerosene. If this potential is to be achieved in the near term, however, manufacturers must produce off-grid lighting products that are inexpensive, perform well, and meet the needs of potential end users. At present, relatively few products meet all three of these goals. In this article, we report results from a detailed study of lighting use by micro-enterprises in two small towns in Kenya's Rift Valley Province. The work included a survey about lighting use by 50 small businesses, careful measurements of kerosene lighting use patterns and associated costs for 23 of these businesses, and a subsequent field trial in which 14 of the 23 businesses purchased and used low cost LED lamps over a number of months.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

COMPACT, TUNABLE COMPTON SCATTERING GAMMA-RAY SOURCES

Recent progress in accelerator physics and laser technology have enabled the development of a new class of gamma-ray light sources based on Compton scattering between a high-brightness, relativistic electron beam and a high intensity laser pulse produced via chirped-pulse amplification (CPA). A precision, tunable gamma-ray source driven by a compact, high-gradient X-band linac is currently under development at LLNL. High-brightness, relativistic electron bunches produced by the linac interact with a Joule-class, 10 ps laser pulse to generate tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range via Compton scattering. The source will be used to excite nuclear resonance fluorescence lines in various isotopes; applications include homeland security, stockpile science and surveillance, nuclear fuel assay, and waste imaging and assay. The source design, key parameters, and current status are presented.

42 ENGINEERING↗

Design and Manufacturing Criteria for Beam Position Monitor (BPM) of Taiwan Photon Source (TPS)

There are quite some considerations when the button feedthrough is designed and manufactured in a new 3rd generation synchrotron light source like the to-be-constructed TPS. It is the responsibility of the button feedthrough designer to design a feedthrough with the lowest probable HOM problem. It is also required for the designer to analyze the consequences for each possible mechanical error during manufacturing and therefore set standards of tolerance. We have been using MAFIA to optimize the design of feedthrough including flange type on bending chamber section and primary BPM on insertion device section. We also have set some criteria for feedthrough manufacturing, inspection, and welding based on hands-on experience on feedthrough electrical properties measuring, sorting, inspection, and laser welding. Here we will present the MAFIA results, electrical measurement results, and laser welding results and analysis. Criteria based on these results will also be presented.

43 PARTICLE ACCELERATORS↗

CHARACTERISTIC SIZE OF FLARE KERNELS IN THE VISIBLE AND NEAR-INFRARED CONTINUA

In this Letter, we present a new approach to estimate the formation height of visible and near-infrared emission of an X10 flare. The sizes of flare emission cores in three wavelengths are accurately measured during the peak of the flare. The source size is the largest in the G band at 4308 A and shrinks toward longer wavelengths, namely the green continuum at 5200 A and NIR at 15600 A, where the emission is believed to originate from the deeper atmosphere. This size-wavelength variation is likely explained by the direct heating model as electrons need to move along converging field lines from the corona to the photosphere. Therefore, one can observe the smallest source, which in our case is 0.''65 {+-} 0.''02 in the bottom layer (represented by NIR), and observe relatively larger kernels in upper layers of 1.''03 {+-} 0.''14 and 1.''96 {+-} 0.''27, using the green continuum and G band, respectively. We then compare the source sizes with a simple magnetic geometry to derive the formation height of the white-light sources and magnetic pressure in different layers inside the flare loop.

79 ASTRONOMY AND ASTROPHYSICS↗

Convergence study of wakefield simulations with GdfidL and ECHO3D

The interaction of charged particle beams with vacuum chamber components gives rise to electromagnetic wakefields, whose frequency-domain representation is known as beam coupling impedance. Geometric impedance arising from discontinuities and transitions in the vacuum chamber is the focus of this study. Minimizing this impedance is essential to mitigate adverse collective effects in modern storage rings operating with high-intensity particle beams. Accurate and reliable impedance simulations is a key factor of the vacuum chamber design. This paper presents the results of a convergence study of two widely used electromagnetic solvers, GdfidL and ECHO3D, applied to key vacuum-chamber components of the National Synchrotron Light Source II (NSLS-II) storage ring. Detailed comparisons are performed for several geometries, including flange absorbers, RF bellows, button-type beam position monitors, and an in-vacuum undulator (IVU). The results show notable differences in convergence and computational efficiency between the two codes. While GdfidL provides highly resolved results and serves as a common benchmark tool, ECHO3D yields consistent results with coarser meshes, significantly reducing simulation time and memory demands. Simulations with a full-geometry IVU model demonstrate that simplified taper-transition models can miss important impedance contributions. In conclusion, these findings provide practical guidelines for efficient and accurate impedance modeling to optimize design of vacuum chamber components for accelerators.

36 MATERIALS SCIENCE↗

A rapid excitation-emission matrix fluorometer utilizing supercontinuum white light and acousto-optic tunable filters

Scanning speed and coupling efficiency of excitation light to optic fibres are two major technical challenges that limit the potential of fluorescence excitation-emission matrix (EEM) spectrometer for on-line applications and in vivo studies. In this paper, a novel EEM system, utilizing a supercontinuum white light source and acousto-optic tunable filters (AOTFs), was introduced and evaluated. The supercontinuum white light, generated by pumping a nonlinear photonic crystal fiber with an 800 nm femtosecond laser, was efficiently coupled into a bifurcated optic fiber bundle. High speed EEM spectral scanning was achieved using AOTFs both for selecting excitation wavelength and scanning emission spectra. Using calibration lamps (neon and mercury argon), wavelength deviations were determined to vary from 0.18 nm to −0.70 nm within the spectral range of 500–850 nm. Spectral bandwidth for filtered excitation light broadened by twofold compared to that measured with monochromatic light between 650 nm and 750 nm. The EEM spectra for methanol solutions of laser dyes were successfully acquired with this rapid fluorometer using an integration time of 5 s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental demonstration of squeezed-state quantum averaging

We propose and experimentally demonstrate a universal quantum averaging process implementing the harmonic mean of quadrature variances. The averaged variances are prepared probabilistically by means of linear optical interference and measurement-induced conditioning. We verify that the implemented harmonic mean yields a lower value than the corresponding value obtained for the standard arithmetic-mean strategy. The effect of quantum averaging is experimentally tested for squeezed and thermal states as well as for uncorrelated and partially correlated noise sources. The harmonic-mean protocol can be used to efficiently stabilize a set of squeezed-light sources with statistically fluctuating noise levels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

OVERVIEW OF MONO-ENERGETIC GAMMA-RAY SOURCES & APPLICATIONS

Recent progress in accelerator physics and laser technology have enabled the development of a new class of tunable gamma-ray light sources based on Compton scattering between a high-brightness, relativistic electron beam and a high intensity laser pulse produced via chirped-pulse amplification (CPA). A precision, tunable Mono-Energetic Gamma-ray (MEGa-ray) source driven by a compact, high-gradient X-band linac is currently under development and construction at LLNL. High-brightness, relativistic electron bunches produced by an X-band linac designed in collaboration with SLAC NAL will interact with a Joule-class, 10 ps, diode-pumped CPA laser pulse to generate tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range via Compton scattering. This MEGa-ray source will be used to excite nuclear resonance fluorescence in various isotopes. Applications include homeland security, stockpile science and surveillance, nuclear fuel assay, and waste imaging and assay. The source design, key parameters, and current status are presented, along with important applications, including nuclear resonance fluorescence. In conclusion, we have optimized the design of a high brightness Compton scattering gamma-ray source, specifically designed for NRF applications. Two different parameters sets have been considered: one where the number of photons scattered in a single shot reaches approximately 7.5 x 10{sup 8}, with a focal spot size around 8 {micro}m; in the second set, the spectral brightness is optimized by using a 20 {micro}m spot size, with 0.2% relative bandwidth.

42 ENGINEERING↗

Identification of uranium oxidation states using oxygen K-edge scanning transmission X-ray microscopy

The field of nuclear forensics is growing in importance, and the increasing capabilities at synchrotron radiation light sources enable non-destructive characterization of oxide particles with better spatial, compositional, and oxidation state speciation resolution than ever before. Here, uranium oxide particles derived from multiple wet chemical processing methods were examined using a scanning transmission X-ray microscope (STXM), and a weakly-supervised method was developed to automatically analyze the collected data. Multiple uranium oxidation states were observed and quantified within and between samples, yielding information about differences between particles produced via the various processing routes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multimodal hard X-ray nanoprobe techniques for operando investigations of photovoltaic devices

Compared with conventional laboratory-scale X-ray techniques, synchrotron based X-rays with higher brilliance and higher coherence allow for the investigation of various material properties with high spatial resolution. The microscopic behaviours of materials can be examined using the Hard X-ray Nanoprobe beamline (I14) at Diamond Light Source, which provides a 50 nm focused beam and has been successfully employed to identify nanoscale optoelectronic features in energy-harvesting materials such as halide perovskites that exhibit local heterogeneity. We have developed X-ray beam-induced current (XBIC) measurement capability at I14 to address the growing demand for operando analysis in energy-harvesting research. Here, we demonstrate that X-ray fluorescence (XRF)/XBIC multimodal measurements are feasible at I14 and apply these newly implemented techniques to study perovskite solar cells with various additive concentrations to understand the effect of the additive on nanoscale optoelectronic performance. This expanded operando characterization capability offers the possibility of monitoring nanometre-scale compositional variations and corresponding optoelectronic features of actual solar cell configurations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tomographic Hard X-ray Phase Contrast Micro- and Nano-imaging at TOMCAT

This article illustrates the phase contrast instrumentation installed at the Tomographic Microscopy and Coherent Radiology beamline (TOMCAT) of the Swiss Light Source. Our experimental framework has been designed to extract phase information at spatial resolutions covering three orders of magnitude. For moderate (5-10 microns) resolutions we implemented a two-gratings interferometer, operated at energies between 14 and 40 keV. For high resolution (1-5 microns) we obtain phase information thanks to a modified transport of intensity approach. For very high-resolutions (0.1-0.5 microns) we developed a broadband hard X-ray full-field microscope operated in Zernike-phase contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗