Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interoperability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,414 records · Page 79

Service Provider Agnostic Adaptive Coding and Modulation System Design

Commercial service providers (CSPs) are increasingly used to provide communications services to near-Earth science and exploration missions. CSPs commonly utilize modems that are designed to implement adaptive coding and modulation (ACM) in unique ways with modems from the same vendor. However, some missions cannot fly a matching vendor modem, either because the vendor only designs modems for terrestrial use, or the mission needs to fly a software defined radio. We present an ACM system design that allows missions to implement ACM on DVB-S2 compliant CSP links without needing to fly a modem from the same vendor the CSP uses. We implement and test our design in an emulated communications testbed. These tests demonstrate that our ACM system design can successfully adapt to link quality changes up to 6.12 dB/second.

Adaptive coding and modulation↗

Service Provider Agnostic Adaptive Coding and Modulation System Design

Commercial service providers (CSPs) are increasingly used to provide communications services to near-Earth science and exploration missions. CSPs commonly utilize modems that are designed to implement adaptive coding and modulation (ACM) in unique ways with modems from the same vendor. However, some missions cannot fly a matching vendor modem, either because the vendor only designs modems for terrestrial use, or the mission needs to fly a software defined radio. We present an ACM system design that allows missions to implement ACM on DVB-S2 compliant CSP links without needing to fly a modem from the same vendor the CSP uses. We implement and test our design in an emulated communications testbed. These tests demonstrate that our ACM system design can successfully adapt to link quality changes up to 6.12 dB/second.

Adaptive coding and modulation↗

To Dim or Not to Dim: Why Is That Still a Difficult Question?

LED lighting is becoming widely adopted and is displacing most traditional lighting technologies. However, the traditional methods used to control light sources have not been similarly displaced. In an effort to address some of the long-standing weaknesses of one of the most popular control methods, the National Electrical Manufacturers Association (NEMA) recently released the ANSI C137.1-2019 standard for 0-10V control of LED drivers and fluorescent ballasts. The new standard builds upon previous specifications by providing requirements for some aspects of dimming-curve shape and endpoints. In order to characterize the performance variation found in market-available LED drivers, and to explore the potential impact of ANSI C137.1, Pacific Northwest National Laboratory’s Connected Lighting Test Bed was used to evaluate the response to 0-10V controls signals of 21 different LED outdoor cobrahead luminaires (typically used for street-lighting applications) that claimed dimmability via a 0-10V interface. The results provide insights about how ANSI C137.1 will affect the performance variation currently found among such products.

0-10V, LED dimming, interoperability↗

Getting to 95

Members of the Tennessee Valley Public Power Association (TVPPA) have the opportunity to interconnect up to 5% of their annual energy requirements in self generation. TVA, their wholesale supplier, is encouraging solar. This presentation introduces IEEE 1547 2018 and provides some high level information on solar cost.

DER↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Security Architecture for Microgrid Integration

The purpose of this document is to present cyber security risk considerations and mitigations for community microgrids. The mitigations discussed herein specifically focus on cyber security technical requirements for the De-centralized Autonomous Community Controller (DAC) as part of the SECURE project’s technology development effort. These requirements also consider the associated security implementation challenges involved with the decentralized characteristics of microgrids where upstream communications to utility security management functions are lost. These security recommendations and technical requirements may be used by microgrid implementers and technology vendors to specify the security design of the microgrid systems and their components.

24 POWER TRANSMISSION AND DISTRIBUTION↗