Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Method and system for automated plant surveillance and manipulation

A method and a system for automated plant surveillance and manipulation are provided. Pursuant to the method and the system, images of target plants are obtained through a machine vision system having multiple cameras. The obtained images of the target plants are processed to determine tissue candidates of the target plants and to determine a position and an orientation of each tissue candidate. A tool is manipulated, based on the position and the orientation of each tissue candidate, to excise each tissue candidate to obtain tissue samples. The tissue samples are transported for subsequently manipulation including live processing of the tissue samples or destructive processing of the tissue samples.

Kalluri, Udaya C.↗

Modeling gated neutron images of THD capsules

Time gating a neutron detector 28m from a NIF implosion can produce images at different energies. The brighter image near 14 MeV reflects the size and symmetry of the capsule 'hot spot'. Scattered neutrons, {approx}9.5-13 MeV, reflect the size and symmetry of colder, denser fuel, but with only {approx}1-7% of the neutrons. The gated detector records both the scattered neutron image, and, to a good approximation, an attenuated copy of the primary image left by scintillator decay. By modeling the imaging system the energy band for the scattered neutron image (10-12 MeV) can be chosen, trading off the decayed primary image and the decrease of scattered image brightness with energy. Modeling light decay from EJ399, BC422, BCF99-55, Xylene, DPAC-30, and Liquid A leads to a preference from BCF99-55 for the first NIF detector, but DPAC 30 and Liquid A would be preferred if incorporated into a system. Measurement of the delayed light from the NIF scintillator using implosions at the Omega laser shows BCF99-55 to be a good choice for down-scattered imaging at 28m.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of quantum dot materials for infrared cameras (Final CRADA Report)

The aim of this project was to develop scalable methods to produce infrared (IR) mercury telluride (HgTe) colloidal quantum dot (CQD) thin films and demonstrate their utility in a proof-of-concept monolithic SWIR focal plane array (FPA). These objectives were accomplished by scaling up the HgTe CQD synthesis, characterizing physical and electrical properties of HgTe CQDs, evaluating solution-processed coating methods for quality and efficiency, and developing a process flow to integrate HgTe CQDs with commercial-off-the-shelf silicon CMOS readout circuits by solution-processed coating to produce monolithic FPAs. The FPA is the image sensor in an infrared imaging system responsible for detecting and processing reflected or emitted light into an infrared image of the scene under observation. The quality of the image is determined by the sensitivity and resolution of the image sensor in the system. Higher resolution IR FPAs enable higher throughput in manufacturing quality assurance, wider field of view for autonomous navigation, and longer range surveillance for defense.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Subsystem Imaging Performance and Modeling of the Infrared Multi-Object Spectrograph

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter). IRMOS is a near-IR (0.8 - 2.5 micron) spectrograph with low to mid resolution (R=lambda/delta, lambda = 300 - 3800). The IRMOS spectrograph produces simultaneous spectra of - 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial MEMS multi-mirror array device (MMA). The IRMOS optical design consists of two imaging systems, or "stages." The focal reducer, stage one, images the focal plane of the telescope onto the MMA. The spectrograph, stage two, images the MMA onto the detector. We describe the breadboard alignment method and imaging and scattered light performance for both the focal reducer and spectrograph. This testing provides verification of the optomechanical alignment method, and a measurement of the contribution of scattered light in the system due to mirror small scale surface error. After the stage I and 2 optics are integrated with the instrument, our test results will make it possible to distinguish between scattered light from the mirrors and the MMA. Image testing will be done at four wavelengths in the visible and near-IR. A mercury-argon pencil lamp will provide spectral lines at 546.1 and 1012 nm, and a blackbody radiation source lines at 1600 and 2200 nm. A CCD camera will be used as a detector for the visible wavelengths, and an IR photodiode will be used for the IR wavelengths. We compare our data with a theoretical analysis using a commercial software package. Mirror surface error is modeled by treating each surface as a superposition of various gratings (e.g., diamond turning tool marks, features due to the impurities of Al 6061, and periodic mid-frequency errors due to drift during machining).

Connelly, Joseph A.↗

MO-F-CAMPUS-J-05: Verification for Prompt Gamma Ray Imaging During Proton Boron Fusion Therapy

Purpose: The purpose of this study is to verify the acquisition of the three dimensional single photon emission computed tomography (SPECT) image using prompt gamma ray originated from proton boron fusion therapy (PBFT). Methods: The real-time imaging system during the PBFT was simulated to acquire the tomographic image of the prompt gamma ray from treated tumor by the proton boron reaction, using Monte Carlo simulation (MCNPX). We acquired percentage depth dose (PDD) of the proton beam in the water phantom including the boron uptake region (BUR), the energy spectra of the prompt gamma ray and tomographic image which can show treated tumor regions. The prompt gamma ray image was reconstructed using maximum likelihood estimation maximization (MLEM) reconstruction algorithm with 64 projections. In addition, in order to evaluate the reconstructed image, the image profiles between BURs were extracted from the image. Results: In the PDD results, the Bragg-peak was amplified definitely when the proton’s maximum dose level was located at the BUR. This amplification is based on the generation of alpha particles. In addition, the prompt gamma ray peak of 719 keV was observed from the energy spectrum. Through the previous process, the tomographic image of prompt gamma ray from the BUR was reconstructed. The line profile was extracted from image including BURs, and it shows high signal-to-noise ratio. Conclusion: We confirmed that the real-time prompt gamma ray image during the PBFT was successfully deducted, and results of quantitative image analysis show good agreement with the original pattern of the BUR. This study first verified the imaging capability of the PBFT-SPECT system. In conclusion, the PBFT-SPECT system can realize the treated tumor monitoring during the PBFT.

60 APPLIED LIFE SCIENCES↗

Final Scientific/Technical Report: Real Time Particle Size and Settling Velocity for In-Situ Monitoring of Deep-Sea Polymetallic Nodule Mining

In the coming decade, it is anticipated that deep-sea mining activities will commence throughout the deep ocean, at depths around 4000-6000m where vast deposits of baseball-sized rocks called polymetallic nodules lay on the seabed. These nodules contain resources such as cobalt, copper and nickel which are needed to produce batteries for electric vehicles. Collector machines driving on the seabed and gathering these nodules will stir up clouds of sediment, and there is concern about how the resulting concentration of sediment in the near-bottom ocean water will affect deep and mid-ocean biology. There is currently no technology capable of comprehensively monitoring the concentrations and properties of stirred up sediment in the deep. This project addressed this critical gap by developing a deep-sea particle measurement system (Real-Time Size and Settling Velocity, RTSSV) that uses a multi-camera high-resolution video imaging system, with accompanying image processing, to measure the concentration, size distribution and settling speed of sediment. Importantly, these measurements are made in-situ, so that delicate sediment aggregates will not be disturbed, as is the case when collecting samples at depth to be measured in the lab. The instrument can be mounted on a variety of established deep-sea platforms such as moorings, AUVs and ROVs, providing data in near real time, where the key measurements need to be made—from the source of the sediment disturbance and throughout the resulting plume—vital for determining if deep-sea mining can be done in an environmentally responsible manner. The developed system (RTSSV) will possess the only such capability worldwide, giving a US-based group a substantial competitive advantage as this newly evolving global industry develops. As added value, the technology will also have widespread application to the offshore oil and gas industry, dredging industry, and to sediment science research.

47 OTHER INSTRUMENTATION↗

Enrichment Determination of Uranium in Shielded Configurations

The determination of the enrichment of uranium is required in many safeguards and security applications. Typical methods of determining the enrichment rely on detecting the 186 keV gamma ray emitted by 235 U. In some applications, the uranium is surrounded by external shields, and removal of the shields is undesirable. In these situations, methods relying on the detection of the 186 keV gamma fail because the gamma ray is shielded easily. Oak Ridge National Laboratory (ORNL) has previously measured the enrichment of shielded uranium metal using active neutron interrogation. The method consists of measuring the time distribution of fast neutrons from induced fissions with large plastic scintillator detectors. To determine the enrichment, the measurements are compared to a calibration surface that is created from Monte Carlo simulations where the enrichment in the models is varied. In previous measurements, the geometry was always known. ORNL is extending this method to situations where the geometry and materials present are not known in advance. In the new method, the interrogating neutrons are both time and directionally tagged, and an array of small plastic scintillators measures the uncollided interrogating neutrons. Therefore, the attenuation through the item along many different paths is known. By applying image reconstruction techniques, an image of the item is created which shows the position-dependent attenuation. The image permits estimating the geometry and materials present, and these estimates are used as input for the Monte Carlo simulations. As before, simulations predict the time distribution of induced fission neutrons for different enrichments. Matching the measured time distribution to the closest prediction from the simulations provides an estimate of the enrichment. This presentation discusses the method and provides results from recent simulations that show the importance of knowing the geometry and materials from the imaging system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging other planetary systems from the moon

This paper studies the problem of using a telescope like the HST, only larger and sensitive to a wider range of wavelengths, to image systems of planets like the solar system around other stars. Both reflected starlight and thermal radiation from the planets are treated. The instrumental effects of aperture diffraction, scattering due to the power spectral density of telescope mirror surface errors, and telescope thermal emission are included. The integration time required to achieve a signal-to-noise ratio is computed at 5 for photon-statistical random errors only, which is a necessary but not sufficient criterion for detection at a confidence level of five standard deviations. A cold telescope on the moon with 16m aperture and the optical quality of HST could detect and characterize planets around nearby stars.

Brown, Robert A.↗

The Development of a Real-Time Optical Angle-of-Attack Measurement Capability at the NASA Ames Unitary Plan Wind Tunnel

The following details the implementation of a real-time optical angle-of-attack capability under development at the NASA Ames Unitary Plan Wind Tunnel (UPWT). Recent advancements in the integration of high bandwidth imaging systems at the Ames UPWT has laid the groundwork for the deployment of a calibrated, imaging based measurement capability. Some of the measurement goals of this data system include: an estimation of the orientation of a wind tunnel model to six degrees of freedom, measurements made at framerates high enough to time resolve model dynamics, triangulate corresponding points of interest from multiple camera views in three-dimensional space, acquire imagery with no impact to the productivity of the test matrix, provide results in real-time, and finally compute an estimation of the errors associated with the measurement. The following will outline the imaging hardware and data systems architecture, describe the data flow and image processing routines currently implemented, and explore example data and results from previous wind tunnel test entries.

Ground Testing↗

Benchmarking a novel ultrasound-CT fusion system for respiratory motion management in radiotherapy: Assessment of spatio-temporal characteristics and comparison to 4DCT

Management of respiratory motion during radiation therapy requires treatment planning and simulation using imaging modalities that possess sufficient spatio-temporal accuracy and precision. An investigation into the use of a novel ultrasound (United States) imaging system for assessment of respiratory motion is presented, exploiting its good soft tissue contrast and temporal precision. The system dynamically superimposes the appropriate image plane sampled from a reference CT data set with the corresponding US B-mode image. An articulating arm is used for spatial registration. While the focus of the study was to quantify the system's ability to track respiratory motion, certain unique spatial calibration procedures were devised that render the software potentially valuable to the general research community. These include direct access to all transformation matrix elements and image scaling factors, a manual latency correction function, and a three-point spatial registration procedure that allows the system to be used in any room possessing a traditional radiotherapy laser localization system. Counter-intuitively, it was discovered that a manual procedure for calibrating certain transformation matrix elements produced superior accuracy to that of an algorithmic Levenberg-Marquardt optimization method. The absolute spatial accuracy was verified by comparing the physical locations of phantom test objects measured using the spatially registered US system, and using data from a 3DCT scan of the phantom as a reference. The spatial accuracy of the display superposition was also tested in a similar manner. The system's dynamic properties were then assessed using three methods. First, the overall system response time was studied using a programmable motion phantom. This included US video update, articulating arm update, CT data set resampling, and image display. The next investigation verified the system's ability to measure the range of motion of a moving anatomical test phantom that possessed both high and low contrast test objects. Finally, the system's performance was compared to that of a four-dimensional CT (4DCT) data set. The absolute spatial and display superposition accuracy was found to be better than 2 mm and typically 1 mm. Overall dynamic system response was adequate to produce a mean relative positional error of less than 1 mm if an empiric latency correction of 3 video frames was incorporated. The dynamic CT/US display mode was able to assess phantom motion for both high and low contrast test objects to within 1 mm, and compared favorably to the 4DCT data. The 4DCT movie loop accurately assessed the target motion for both of the high and low contrast objects tested, but the minimum intensity and average intensity reconstructions did not. This investigation demonstrated that this US system possesses sufficient spatio-temporal accuracy to properly assess respiratory motion. Future work will seek to demonstrate efficacy in its clinical application to respiratory motion assessment, particularly for sites in the upper abdomen, where low tissue contrast is evident.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

System description and analysis. Part 1: Feasibility study for helicopter/VTOL wide-angle simulation image generation display system

A preliminary design for a helicopter/VSTOL wide angle simulator image generation display system is studied. The visual system is to become part of a simulator capability to support Army aviation systems research and development within the near term. As required for the Army to simulate a wide range of aircraft characteristics, versatility and ease of changing cockpit configurations were primary considerations of the study. Due to the Army's interest in low altitude flight and descents into and landing in constrained areas, particular emphasis is given to wide field of view, resolution, brightness, contrast, and color. The visual display study includes a preliminary design, demonstrated feasibility of advanced concepts, and a plan for subsequent detail design and development. Analysis and tradeoff considerations for various visual system elements are outlined and discussed.

Source record↗

A front-end readout Detector Board for the OpenPET electronics system

Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, which allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.

47 OTHER INSTRUMENTATION↗

New camera tube improves ultrasonic inspection system

Electron multiplier, incorporated into the camera tube of an ultrasonic imaging system, improves resolution, effectively shields low level circuits, and provides a high level signal input to the television camera. It is effective for inspection of metallic materials for bonds, voids, and homogeneity.

Berger, H.↗

Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power-law descriptions of the phantom images were in general agreement with real human images. The Singlet approach offered more realistic contrast as compared to the Doublet approach, but at the expense of air bubbles and air pockets that formed during the filling process. Conclusions: The presented physical breast phantoms and their matching virtual breast phantoms offer realistic breast anatomy, patient variability, and ease of use, making them a potential candidate for performing both system quality control testing and virtual clinical trials.

60 APPLIED LIFE SCIENCES↗

Imaging Antenna Structure For Submillimeter Wavelengths

Integrated-circuit antenna structure contains two-dimensional array of antennas and antenna reflectors. In receiving mode, each antenna acts as part of detector for one picture element in millimeter- or submillimeter-wavelength imaging radar system. Millimeter-wave imaging system used to view objects through fog, smoke, or smog with resolution intermediate between microwave and visible-light imaging systems. Antenna elements, supports, and reflectors made by integrated-circuit techniques. Structures fabricated on front and back substrates separately. Substrates then joined. Inexpensive way to provide large number of small antenna elements required for imaging, all mounted rigidly in way that does not degrade operation.

Rebeiz, G.↗

Image Data Processing System (IDAPS) user manual, S-056 experiment. Volume 1: System description. Volume 2: Batch IDAPS. Volume 3: Interactive IDAPS

Image data processing system (IDAPS) developed to satisfy the image processing requirements of the Skylab S-056 experiment is described. The S-056 experiment was designed to obtain high-resolution photographs of the sun in the far ultraviolet, or soft X-ray, portion of the electromagnetic spectrum. Thirty-five thousand photographs were obtained by the three flights of the program; and, faced with such a massive volume of imagery, the designers of the experiment decided to develop a computer-based system which would reduce the image processing workload. The purpose of the IDAPS User Manual is to give the IDAPS user the necessary information and instructions to effectively utilize the system.

Source record↗

Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems

Purpose: To study the sensitivity of a geometric calibration method using projection matrices for digital tomosynthesis systems. Methods: A generic geometric calibration method for tomographic imaging systems has been presented in our previous work. The method involves a scan of a calibration phantom with multiple markers. Their locations in projection images are detected and are associated with their 3D coordinates to compute 3x4 projection matrices, which can be used in subsequent image reconstruction. The accuracy of geometric calibration may be affected by errors in the input data of marker positions. The effects of errors may depend on the number of markers and the volume surrounded by them in 3D space. This work analyzed the sensitivity of the calibration method to the above factors. A 6 cm CIRS breast research phantom and a prototype breast tomosynthesis system were used for our tests. A high contrast ring and two small speck groups were reconstructed in various testing cases for comparison. To achieve quantitative assessment, a 15x15 point detection mask was adopted for detecting signals and for computing changes between testing cases and the regular geometric calibration. Results: When 3D coordinates and 2D projections of markers were accurate, all tested numbers of markers, 6-44, provided similar high quality reconstructions of the ring and the two speck groups. Errors in marker positions resulted in image degradations and signal changes, which increased with fewer markers and smaller volume surrounded by markers in the 3D object space. Signal changes of small specks were more significant than those of the ring. Errors in marker projections produced drastic image degradations. Coplanar marker placement caused a failure in projection matrix computation. Conclusions: For practical geometric calibration phantom design, ample markers are desired. They need to have a large volumetric coverage in the 3D space and be far from being coplanar. Precise determination of marker projections on detector planes is crucial for accurate geometric calibration and for small object detection using the reconstructed images.

60 APPLIED LIFE SCIENCES↗