Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Installation guidelines for solar heating system, single-family residence at William OBrien State Park, Stillwater, Minnesota

Installation procedures for the single family residential solar heating system at the William O'Brien State Park, Stillwater, Minnesota, are presented. The system is a solar-assisted, hydronic-to-warm-air system with solar-assisted domestic water heating. It is composed of the following major components: liquid cooled flat plate collectors; water storage tank; passive solar-fired domestic water preheater; electric hot water heater; heat pump with electric backup; solar hot water coil unit; tube-and-shell heat exchanger, three pumps, and associated pipes and valving in an energy transport module; control system; and air-cooled heat purge unit. Installer guidelines are provided for each subsystem and includes testing and filling the system. Information is also given on the operating procedures, controls, caution requirements and routine and schedule maintenance.

Source record↗

Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas

A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.

Source record↗

Ion heating by strong electrostatic ion cyclotron turbulence

A theory of the ion heating due to electrostatic ion cyclotron (EIC) waves in the auroral zone is presented. Due to the slowly convecting nature of the EIC mode, quasi-linear plateau formation cannot stabilize the waves, and growth occurs until the nonlinear mechanisms of ion resonance broadening and electron trapping provide saturation. The large amplitude and coherent nature of the resulting wave imply that quasi-linear theory provides only a lower limit to the ion heating. An upper bound on the heating rate is derived using a time-average model of ion dynamics in the coherent waves. The effects of ion heating in the presence of the magnetic gradient force and parallel electric fields are considered, with the result that perpendicular energies over 100 eV are easily attainable from a 1 eV source plasma. Perpendicular heating in the absence of a parallel electric field yields conical ion distributions, which in the presence of an electric field become field-aligned beams.

Lysak, R. L.↗

A numerical study of the effects of heat diffusion through the base of the mixed layer

In the present paper, a simple numerical model is used to study the warming of the mixed layer during the early summer. It is shown that the springtime temperature increase in the layer below the mixed layer (for example, in the cold pool on a continental shelf) has a maximum value which occurs for a limiting value of the surface heat flux. This is a result of the positive feedback at large Richardson numbers between stability and vertical diffusion of heat. The springtime temperature increase in the mixed layer increases nonlinearly with surface heat flux, because of the same positive feedback. The effects of interseasonal fluctuations of the surface heat flux on the spring and summer mixed layer and deeper temperature increases can be as great as the effect of interseasonal fluctuations of the average heat flux.

Posmentier, E. S.↗

The heating of gas in clusters of galaxies by relativistic electrons - Collective effects

We show that the rate at which gas is heated in X-ray clusters of galaxies by streaming relativistic electrons can be much greater than the Coulomb heating rate because of the stimulated growth of a high level of electrostatic turbulence and its subsequent collapse to shorter wavelengths. This enhanced heating (and, hence, energy loss) rate allows the X-ray emitting gas to be heated by those particles which are observable through their synchrotron emission at low radio frequencies and yields a radio source size consistent with the observed radio halo sizes in the Coma cluster. The heating of gas in clusters of galaxies by relativistic electrons will significantly affect the cluster gas dynamics.

Scott, J. S.↗

Space Shuttle Orbiter flight heating rate measurement sensitivity to thermal protection system uncertainties

A study was completed to determine the sensitivity of computed convective heating rates to uncertainties in the thermal protection system thermal model. Those parameters considered were: density, thermal conductivity, and specific heat of both the reusable surface insulation and its coating; coating thickness and emittance; and temperature measurement uncertainty. The assessment used a modified version of the computer program to calculate heating rates from temperature time histories. The original version of the program solves the direct one dimensional heating problem and this modified version of The program is set up to solve the inverse problem. The modified program was used in thermocouple data reduction for shuttle flight data. Both nominal thermal models and altered thermal models were used to determine the necessity for accurate knowledge of thermal protection system's material thermal properties. For many thermal properties, the sensitivity (inaccuracies created in the calculation of convective heating rate by an altered property) was very low.

Bradley, P. F.↗

Solar heating and hot water system installed at Arlington Raquetball Club, Arlington, Virginia

A solar space and water heating system is described. The solar energy system consists of 2,520 sq. ft. of flat plate solar collectors and a 4,000 gallon solar storage tank. The transfer medium in the forced closed loop is a nontoxic antifreeze solution (50 percent water, 50 percent propylene glycol). The service hot water system consists of a preheat coil (60 ft. of 1 1/4 in copper tubing) located in the upper third of the solar storage tank and a recirculation loop between the preheat coil and the existing electric water heaters. The space heating system consists of two separate water to air heat exchangers located in the ducts of the existing space heating/cooling systems. The heating water is supplied from the solar storage tank. Extracts from site files, specification references for solar modifications to existing building heating and hot water systems, and installation, operation and maintenance instructions are included.

Source record↗

Influence of thermal boundary conditions on heat transfer from a cylinder in cross flow

Local heat transfer data over the leading surface of a cylinder in crossflow were obtained for a Reynolds number range of 50,000. The cylinder was operated at both uniform-wall-temperature and uniform-heat-flux thermal ance of 80 deg from the front stagnation point, the uniform-wall-temperature heat transfer coefficients were as much as 66 percent lower than the uniform-heat-flux data. Between the stagnation point and 60 deg around the cylinder, there were no significant differences in the data. This region of the cylinder is within the cylindrical curvature region of the front end of a real turbine so it was concluded that either thermal boundary condition could be used to model turbine flow over that region of the blade. Results of evaluating the exponent x in the fundamental relationship Nu=f(Re) sup x, which is used in data correlation show the exponent varies as a function of local position on the cylinder even in the laminar flow region. The value of x increases linearly from 0.50 at the stagnation point to 0.59 at 60 deg around the cylinder. This linear trend continued into the separation region at 80 deg for the uniform-wall-temperature data, but x increased markedly in the separation region for the uniform-heat-flux data.

Papell, S. S.↗

Parametric results for heat transfer across honeycomb sandwich panels

The problem of heat transfer across honeycomb sandwich panels is theoretically investigated. The basic objective is to predict the rear surface temperature as a function of time when the front surface is exposed to a prescribed heat flux; the faces are bounded by planar sheets so that the air circulation in the honeycomb cells is bounded and contained. The influence of the air circulation on convective heat transfer is explicitly included. Drawing upon previous investigators' results that indicated various relations for the Nusselt numbers vs Rayleigh numbers in different regimes of the aspect ratio (defined as the ratio of the cell height to cell width), parametric calculations are performed to predict the rear surface temperatures. Chemical degradation of the material, especially the glue holding the face material on the end, is important but has not yet been included. The results indicate that decreasing the cell width, increasing the cell wall thickness and increasing the cell height all have beneficial effects upon the heat transfer; i.e., all of these variations reduce rear surface temperature for a given time for a prescribed heat flux on the front surface.

Ramohalli, K.↗

Heat transfer from a row of impinging jets to concave cylindrical surfaces

Starting from the first principles, and with one experimentally obtained parameter, an expression for stagnation heat transfer is derived, applicable to round, impinging jets. The results obtained with a row of air jets impinging on an electrically-heated surface in a small-scale setup characteristic of a typical turbine blade have been found compatible with the average heat transfer from a geometrically similar, steam-heated surface scaled up ten times, and comparable with the results of other investigators. These findings were linked to the flow fields likely to exist in the gas turbine blades, internally cooled by a row of round jets or a single jet of equivalent width. The magnitude of heat-transfer coefficients obtained here with impinging jets approaches that normally associated with forced convection of water and evaporative cooling.

Hrycak, P.↗

Heating of chromospheres and coronae in cool stars

Recent evidence is summarized that suggests that neither of two traditional views of chromospheric heating (that the flux of energy required to heat the solar chromosphere) is only a small fraction of the total radiative energy emerging from the solar interior and that chromospheres are heated by acoustic waves generated in the convection zone (which lies close to the surface of the star) is valid. Particular attention is given to cool stars, both dwarfs and giants. The directions in which research is currently heading in attempting to understand heating of chromospheres and coronae in these stars are indicated. Hot stars are excluded from consideration because radiation pressure plays an important role in their atmospheric heating. It is concluded that the role of magnetic fields in giants is different from the role in dwarfs.

Mullan, D. J.↗

An empirical method for computing leeside centerline heating on the Space Shuttle Orbiter

An empirical method is presented for computing top centerline heating on the Space Shuttle Orbiter at simulated reentry conditions. It is shown that the Shuttle's top centerline can be thought of as being under the influence of a swept cylinder flow field. The effective geometry of the flow field, as well as top centerline heating, are directly related to oil-flow patterns on the upper surface of the fuselage. An empirical turbulent swept cylinder heating method was developed based on these considerations. The method takes into account the effects of the vortex-dominated leeside flow field without actually having to compute the detailed properties of such a complex flow. The heating method closely predicts experimental heat-transfer values on the top centerline of a Shuttle model at Mach numbers of 6 and 10 over a wide range in Reynolds number and angle of attack.

Helms, V. T., III↗

Chatanika radar observations relating to the latitudinal and local time variations of Joule heating

Observations of plasma convection made with the Chatanika incoherent scatter radar have been analyzed to give latitude/local time plots of the electric field contribution (E squared) to thermospheric Joule heating. The data, which plan the invariant latitude range 56 deg to 75 deg, show the presence of strong heating throughout the auroral regions. Of special interest are brief interludes of intense heating (greater than 50 mW/sq m) that are observed at nearly all local times and latitudes in response to magnetospheric disturbances. Further, there seem to be particular regions of the auroral oval where Joule heating seems to be continually enhanced above the broad background. The results of six 24-hour experiments are presented to illustrate summer and winter conditions. A shorter eight hour experiment is also given to show the characteristics of cleft heating, insofar as they are visible to the Chatanika radar.

Banks, P. M.↗

Comparison of Several Methods of Cyclic De-Icing of a Gas-Heated Airfoil

Several methods of cyclic de-icing of a gas-heated airfoil were investigated to determine ice-removal characteristics and heating requirements. The cyclic de-icing system with a spanwise ice-free parting strip in the stagnation region and a constant-temperature gas-supply duct gave the quickest and most reliable ice removal. Heating requirements for the several methods of cyclic de-icing are compared, and the savings over continuous ice prevention are shown. Data are presented to show the relation of surface temperature, rate of surface heating, and heating time to the removal of ice.

Gray, Vernon H.↗

Investigation of Heat Transfer from a Stationary and Rotating Conical Forebody

The convective heat transfer from the surface of a conical forebody having a hemispherical nose, an included angle of approximately 30 deg, and. a maximum diameter of 18.9 inches was investigated in a wind tunnel for both stationary and. rotating operation. The range of test conditions included free-stream velocities up to 400 feet per second, rotational speeds up to 1200 rpm, and. angles of attack of 0 deg and 6 deg. Both a uniform surface temperature and a uniform heater input power density were used. The Nusselt-Reynolds number relations provided good correlation of the heat-transfer data for the complete operating range at 0 deg angle of attack with and without spinner rotation, and for 6deg angle of attack with rotation. Rotational speeds up to 1200 rpm had no apparent effect on the heat-transfer characteristics of the spinner. The results obtained at 6 deg angle of attack with rotation were essentially the same as those obtained at 0 deg angle of attack without rotation. The experimental heat-transfer characteristics in the turbulent flow region were consistently in closer agreement with the results predicted for a two-dimensional body than with those predicted. for a cone. For stationary operation at 60 angle of attack, the measured heat-transfer coefficients in the turbulent flow region were from 6 to 13 percent greater on the lower surface (windward. side) than on the upper surface (sheltered side) for corresponding surface locations. The spinner-nose geometry appeared to cause early boundary-layer transition. Transition was initiated at a fairly constant Reynolds number (based on surface distance from nose) of 8.0 x 10(exp 4). Transition was completed at Reynolds numbers less than 5.0 x 10(exp 5) for all conditions investigated.

Ruggeri, Robert S.↗

Comparison of Heat Transfer from Airfoil in Natural and Simulated Icing Conditions

An investigation of the heat transfer from an airfoil in clear air and in simulated icing conditions was conducted in the NACA Lewis 6- by 9-foot icing-research tunnel in order to determine the validity of heat-transfer data as obtained in the tunnel. This investiation was made on the same model NACA 65,2-016 airfoil section used in a previous flight study, under similar heating, icing, and operating conditions. The effect of tunnel turbulence, in clear air and in icingwas indicated by the forward movement of transition from laminar to turbulent heat transfer. An analysis of the flight results showed the convective heat transfer in icing to be considerably different from that measured in clear air and. only slightly different from that obtained in the icing-research tunnel during simulated icing.

Gelder, Thomas F.↗

Preliminary Results of Heat Transfer from a Stationary and Rotating Ellipsoidal Spinner

Convective heat-transfer coefficients in dry air were obtained for an ellipsoidal spinner of 30-inch maximum diameter for both stationary and rotating operation over a range of conditions including airspeeds up to 275 miles per hour, rotational speeds up to 1200 rpm, and angles of attack of zero and 40 The results are presented in terms of Nusselt numbers, Reynolds numbers, and convective heat-transfer coefficients. The studies included both uniform heating densities over the spinner and uniform surface temperatures.. In general, the results showed that rotation will increase the convective heat transfer from a spinner, especially in the turbulent-flow regions. Rotation of the spinner at 1200 rpm and at a free-stream velocity of 275 miles per hour increased the Nusselt number parameter in the turbulent-flow region by 32 percent over that obtained with a stationary spinner; whereas in the nose region, where the flow was laminar, an increase of only 18 percent was observed. Transition from laminar to turbulent flow occurred over a large range of Reynolds numbers primarily because of surface roughness of the spinner. Operation at an angle of attack of 40 had only small effects on the local convective heat transfer for the model studied.

vonGlahn, U.↗

The Calculated and Measured Performance Characteristics of a Heated-Wire Liquid-Water-Content Meter for Measuring Icing Severity

Ground tests have been made of an instrument which, when assembled in a more compact form for flight installation, could be used to obtain statistical flight data on the liquid-water content of icing clouds and to provide an indication of icing severity. The sensing element of the instrument consists of an electrically heated wire which is mounted in the air stream. The degree of cooling of the wire resulting from evaporation of the impinging water droplets is a measure. of the liquid-water content of the cloud. Determination of the value of the liquid-water content from the wire temperature at any instant requires a knowledge of the airspeed, altitude, and air temperature. An analysis was made of the temperature response of a heated wire exposed to an air stream containing water drops. Comparisons were made of the liquid-water content as measured with several heated wires and absorbent cylinders in an artificially produced cloud. For one of the wires, comparative tests were made with a rotating-disk icing-rate meter in an icing wind tunnel. From the test results, it was shown that an instrument for measuring the concentration of liquid water in an air stream can be built using an electrically heated wire of known temperatureresistance characteristics, and that the performance of such a device can be predicted using appropriate theory. Although an instrument in a form suitable for gathering statistical data in flight was not built, the practicability of constructing such an instrument was illustrated. The ground-test results indicated that a flight heated-wire instrument would be simple and durable, would respond rapidly to variations in liquid-water content, and could be used for the measurement of water content in clouds which are above freezing temperature, as well as in icing clouds.

Neel, Carr B.↗