Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Microwave photonic filter using multiwavelength Brillouin-erbium fiber laser with double-Brillouin-frequency shift

A microwave photonic filter based on double-Brillouin-frequency spaced multiwavelength Brillouin-erbium fiber laser (BEFL) is experimentally demonstrated. The filter selectivity can be easily adjusted by tuning and apodizing the optical taps generated from the multiwavelength BEFL. Reconfiguration of different frequency responses are demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rod-filter-field optimization of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second-stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). Although rod-filter-field (RFF) is indispensable and one of the most beam performance dominative parameters for the RF-driven H{sup −} ion source with the internal-antenna, the procedure to optimize it is not established. In order to optimize the RFF and establish the procedure, the beam performances of the J-PARC source with various types of rod-filter-magnets (RFMs) were measured. By changing RFM’s gap length and gap number inside of the region projecting the antenna inner-diameter along the beam axis, the dependence of the H{sup −} ion beam intensity on the net 2MHz-RF power was optimized. Furthermore, the fine-tuning of RFM’s cross-section (magnetmotive force) was indispensable for easy operation with the temperature (T{sub PE}) of the plasma electrode (PE) lower than 70°C, which minimizes the transverse emittances. The 5% reduction of RFM’s cross-section decreased the time-constant to recover the cesium effects after an slightly excessive cesiation on the PE from several 10 minutes to several minutes for T{sub PE} around 60°C.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tunability of multichannel optical filter based on magnetized one-dimensional plasma photonic crystal

A one dimensional plasma photonic crystal (1DPPC) structure was proposed to design a tunable compressing/broadening multi-channel optical filter with external controllability. The 1DPPC with arrangement of (AP){sup n}D(PA){sup n}, where A and D are the dielectric materials, P is a magnetized plasma layer and n is the number of the periodicity, was proposed. The well-known transfer matrix method was employed for analysis. In linear transmittance spectrum, n − 1 defect modes were appeared inside the photonic band gap. The results were shown that by increasing the applied magnetic field intensity and its direction, a red-shift and blue-shift were, respectively, observed in defect mode frequencies. On the other hand, the modes were compressed and broadened with increasing the intensity and the direction of the applied magnetic field, respectively. Externally controllable defect modes can be useful in designing a multichannel tunable optical filter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Wien filter for small ion gun of surface analysis

The gas cluster ion beam (GCIB) and liquid metal ion beam have been studied in the context of ion beam usage for analytical equipment in applications such as X-ray photoelectron spectroscopy and secondary ion mass spectroscopy (SIMS). In particular, small ion sources are used for the secondary ion generation and ion etching. To set the context to this study, the SIMS project has been launched to develop ion-gun based analytical equipment for the Korea Basic Science Institute. The objective of the first stage of the project is the generation of argon beams with a GCIB system [A. Kirkpatrick, Nucl. Instrum. Methods Phys. Res., Sect. B 206, 830–837 (2003)] that consists of a nozzle, skimmer, ionizer, acceleration tube, separation system, transport system, and target. The Wien filter directs the selected cluster beam to the target system by exploiting the velocity difference of the generated particles from GCIB. In this paper, we present the theoretical modeling and three-dimensional electromagnetic analysis of the Wien filter, which can separate Ar{sup +}{sub 2500} clusters from Ar{sup +}{sub 2400} to Ar{sup +}{sub 2600} clusters with a 1-mm collimator.

43 PARTICLE ACCELERATORS↗

Broadband filters for abatement of spontaneous emission in circuit quantum electrodynamics

The ability to perform fast, high-fidelity readout of quantum bits (qubits) is essential to the goal of building a quantum computer. However, coupling a fast measurement channel to a superconducting qubit typically also speeds up its relaxation via spontaneous emission. Here, we use impedance engineering to design a filter by which photons may easily leave the resonator at the cavity frequency but not at the qubit frequency. We implement this broadband filter in both an on-chip and off-chip configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The second filter’s second coming

We measured sound-evoked vibrations at the stereociliary side of inner and outer hair cells and their surrounding supporting cells, using optical coherence tomography interferometry in living anesthetized guinea pigs. Our measurements demonstrate a gradient in frequency tuning among different cell types, going from a high best frequency at the inner hair cells to a lower one at the Hensen cells. This causes the locus of maximum inner hair cell activation to be shifted toward the apex of the cochlea as compared to the outer hair cells. These observations show that additional processing and filtering of acoustic signals occurs within the organ of Corti prior to inner hair cell excitation, thus reinstating a transformed second filter as a mechanism contributing to cochlear frequency tuning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultralow-frequency Raman system down to 10 cm{sup −1} with longpass edge filters and its application to the interface coupling in t(2+2)LGs

Ultralow-frequency (ULF) Raman spectroscopy becomes increasingly important in the area of two-dimensional (2D) layered materials; however, such measurement usually requires expensive and nonstandard equipment. Here, the measurement of ULF Raman signal down to 10 cm{sup −1} has been realized with high throughput by combining a kind of longpass edge filters with a single monochromator, which are verified by the Raman spectrum of L-cystine using three laser excitations. Fine adjustment of the angle of incident laser beam from normal of the longpass edge filters and selection of polarization geometry are demonstrated how to probe ULF Raman signal with high signal-to-noise. Davydov splitting of the shear mode in twisted (2+2) layer graphenes (t(2+2)LG) has been observed by such system in both exfoliated and transferred samples. We provide a direct evidence of twist-angle dependent softening of the shear coupling in t(2+2)LG, while the layer-breathing coupling at twisted interfaces is found to be almost identical to that in bulk graphite. This suggests that the exfoliation and transferring techniques are enough good to make a good 2D heterostructures to demonstrate potential device application. This Raman system will be potentially applied to the research field of ULF Raman spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A rapid excitation-emission matrix fluorometer utilizing supercontinuum white light and acousto-optic tunable filters

Scanning speed and coupling efficiency of excitation light to optic fibres are two major technical challenges that limit the potential of fluorescence excitation-emission matrix (EEM) spectrometer for on-line applications and in vivo studies. In this paper, a novel EEM system, utilizing a supercontinuum white light source and acousto-optic tunable filters (AOTFs), was introduced and evaluated. The supercontinuum white light, generated by pumping a nonlinear photonic crystal fiber with an 800 nm femtosecond laser, was efficiently coupled into a bifurcated optic fiber bundle. High speed EEM spectral scanning was achieved using AOTFs both for selecting excitation wavelength and scanning emission spectra. Using calibration lamps (neon and mercury argon), wavelength deviations were determined to vary from 0.18 nm to −0.70 nm within the spectral range of 500–850 nm. Spectral bandwidth for filtered excitation light broadened by twofold compared to that measured with monochromatic light between 650 nm and 750 nm. The EEM spectra for methanol solutions of laser dyes were successfully acquired with this rapid fluorometer using an integration time of 5 s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband bandpass Purcell filter for circuit quantum electrodynamics

In circuit quantum electrodynamics, qubits are typically measured using dispersively coupled readout resonators. Coupling between each readout resonator and its electrical environment, however, reduces the qubit lifetime via the Purcell effect. Inserting a Purcell filter counters this effect while maintaining high readout fidelity but reduces measurement bandwidth and, thus, limits multiplexing readout capacity. In this Letter, we develop and implement a multi-stage bandpass Purcell filter that yields better qubit protection while simultaneously increasing measurement bandwidth and multiplexed capacity. Here, we report on the experimental performance of our transmission-line-based implementation of this approach, a flexible design that can easily be integrated with current scaled-up, long coherence time superconducting quantum processors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural, chemical, and electronic control in Co–SiNx granular metals for high-pass filter applications

Granular metals, consisting of nanoscale conducting and insulating regions, have been studied for more than 50 years for fundamental and applied research. Granular metals exhibit non-linear conductivity vs frequency behavior, consistent with the universal power law response, and have recently been suggested for high-pass filter applications. Here, we report that cobalt–silicon nitride (Co–SiNx) granular metals with optimized sputter conditions and post-growth annealing exhibit an exceptional 109 increase in conductivity at 1 MHz compared to the DC conductivity. The improved frequency response is correlated with structural and chemical improvements examined via scanning transmission electron microscopy and x-ray photoemission spectroscopy. While we focus on improvements for high-pass filter applications, the structural, chemical, and electronic control demonstrated here will benefit a variety of granular metal and nanoparticle applications.

Annealing↗

Holmium laser with an acousto-optic paratellurite filter

Experimental results on a solid-state holmium laser (Ho : YAG) with an intracavity acousto-optic paratellurite filter are presented. The laser power in cw and repetitively pulsed regimes is determined experimentally. It is shown that the use of an acoustooptic filter in the Ho : YAG laser cavity makes it possible to solve several important problems such as obtaining repetitively pulsed lasing, wavelength tuning and linearly polarised emission. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron mean-free-path filtering in Dirac material for improved thermoelectric performance

Recent advancements in thermoelectric materials have largely benefited from various approaches, including band engineering and defect optimization, among which the nanostructuring technique presents a promising way to improve the thermoelectric figure of merit ( zT ) by means of reducing the characteristic length of the nanostructure, which relies on the belief that phonons’ mean free paths (MFPs) are typically much longer than electrons’. Pushing the nanostructure sizes down to the length scale dictated by electron MFPs, however, has hitherto been overlooked as it inevitably sacrifices electrical conduction. Here we report through ab initio simulations that Dirac material can overcome this limitation. The monotonically decreasing trend of the electron MFP allows filtering of long-MFP electrons that are detrimental to the Seebeck coefficient, leading to a dramatically enhanced power factor. Using SnTe as a material platform, we uncover this MFP filtering effect as arising from its unique nonparabolic Dirac band dispersion. Room-temperature zT can be enhanced by nearly a factor of 3 if one designs nanostructures with grain sizes of ∼10 nm. Our work broadens the scope of the nanostructuring approach for improving the thermoelectric performance, especially for materials with topologically nontrivial electronic dynamics.

42 ENGINEERING↗

Identification of Distorted Gamma-Ray Signature Patterns Using Digital Filtering and Auto-Associative Memory Implemented with a Hopfield Neural Network

The detection and identification of radioactive sources in search applications involve analyzing passive gamma-ray emissions from high-level radioactive materials. This process uses a mobile detector-spectrometer in a complex field test environment. Recently, the use of artificial intelligence for gamma-ray spectrum analysis has shown promising results. However, challenges persist in identifying isotopic signatures from spectral measurements that may be distorted due to source shielding, random variations in natural radioactive background, or insufficient measurement time to obtain clear spectral lines. Here, this paper presents a novel intelligent signature recognition method that combines digital filtering techniques with an artificial Hopfield Neural Network (HNN). The HNN leverages auto-associative memory to store training sample patterns and match them with incoming gamma spectra from distorted sources. It restores the testing sources’ measurements by finding the closest matching signature patterns in the spectral library. Before HNN recognition, the measured spectrum undergoes preprocessing with a digital image filter to reduce fluctuations. Performance of the proposed method is evaluated using a set of gamma-ray spectra measured with a sodium iodide detector. The data collected include measurements from six pure samples: 241 Am, 60 Co, 137 Cs, 192 Ir, 239 Pu, and 235 U, which are used for training and validation (i.e. six cases). Additionally, the data set contains 24 distorted synthesized sources with various fluctuating backgrounds. Test results demonstrate the potential of the proposed method to accurately recognize the correct isotope with high precision, achieving an accuracy rate exceeding 85%. Furthermore, the proposed method exhibits superior performance compared to the conventional multiple regression fitting and simple feedforward neural network methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absorption/transmission measurements of PSAP particle-laden filters from the Biomass Burning Observation Project (BBOP) field campaign

Absorptivity measurements with a laser-heating approach, referred to as the laser-driven thermal reactor (LDTR), were carried out in the infrared and applied at ambient (laboratory) nonreacting conditions to particle-laden filters from a three-wavelength (visible) particle/soot absorption photometer (PSAP). Here, the particles were obtained during the Biomass Burning Observation Project (BBOP) field campaign. The focus of this study was to determine the particle absorption coefficient from field-campaign filter samples using the LDTR approach, and compare results with other commercially available instrumentation (in this case with the PSAP, which has been compared with numerous other optical techniques).

54 ENVIRONMENTAL SCIENCES↗

Jacobian sparsity detection using Bloom filters

Determining Jacobian sparsity structure is an important step in the efficient computation of sparse Jacobians. We introduce a new method for determining Jacobian sparsity patterns by combining bit vector probing with Bloom filters. In conclusion, we further refine Bloom filter probing by combining it with hierarchical probing to yield a highly effective strategy for Jacobian sparsity pattern determination.

Bloom filter↗

Estimation of plasma properties using an extended Kalman filter with plasma global models

A physically-constrained extended Kalman filter (EKF) is applied to various zero-dimensional global models for the estimation of plasma properties using time-dependent experimental data such as the plasma density or ion flux. The capability of the EKF is demonstrated to estimate unknown system states simultaneously, such as reaction rate coefficients and the absorbed electron input power, which can be difficult, if not impossible, to measure experimentally. Global models accounting for pure argon reactions and argon-oxygen reactions are used in this work to demonstrate the ability of the filter to estimate dynamic and complex systems. Furthermore, the results obtained from the EKF plasma global model illustrate that model-data fusion techniques can be used to estimate plasma properties and processes for time-varying systems, such as pulsed discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Fit Evaluation of N95 Filtering Facepiece Respirators and Coronavirus Inactivation Following Heat Treatment

Abstract Reuse of filtering facepiece respirators (FFRs, commonly referred to as N95s) normally meant for single use has become common in healthcare facilities due to shortages caused by the COVID-19 pandemic. Here, we report that murine hepatitis coronavirus initially seeded on FFR filter material is inactivated (6 order of magnitude reduction as measured by median tissue culture infective dose, TCID50) after dry heating at 75°C for 30 min. We also find that the quantitative fit of FFRs after heat treatment at this temperature, under dry conditions or at 90% relative humidity, is not affected by single or 10 heating cycles. Previous studies have reported that the filtration efficiency of FFRs is not negatively impacted by these heating conditions. These results suggest that thermal inactivation of coronaviruses is a potentially rapid and widely deployable method to reuse N95 FFRs in emergency situations where reusing FFRs is a necessity and broad-spectrum sterilization is unavailable. However, we also observe that a radiative heat source (e.g. an exposed heating element) results in rapid qualitative degradation of the FFR. Finally, we discuss differences in the results reported here and other recent studies investigating heat as a means to recycle FFRs. These differences suggest that while our repeated decontamination cycles do not affect FFR fit, overall wear time and the number of donning/doffing cycles are important factors that likely degrade FFR fit and must be investigated further.

60 APPLIED LIFE SCIENCES↗

Robust Cubature Kalman Filter for Dynamic State Estimation of Synchronous Machines Under Unknown Measurement Noise Statistics

The Kalman-type filtering techniques including cubature Kalman filter (CKF) does not work well in non-Gaussian environments, especially in the presence of outliers. To solve this problem, Huber's M-estimation-based robust CKF (RCKF) is proposed for synchronous machines by combining the Huber's M-estimation theory with the classical CKF, which is capable of coping with the deterioration in performance and discretization of tracking curves when measurement noise statistics deviate from the prior noise statistics. The proposed RCKF algorithm has good adaptability to unknown measurement noise statistics characteristics including non-Gaussian measurement noise and outliers. The simulation results on the WSCC 3-machine 9-bus system and New England 16-machine 68-bus system verify the effectiveness of the proposed method and its advantage over the classical CKF.

42 ENGINEERING↗