Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

EMT Models to Evaluate Traveling Wave-Based Protection in Distribution System

The distribution system is going through significant changes. One of them is the high penetration of inverter-based distributed energy resources in the distribution system. Due to this high penetration, there is a need for a better protection system. Multiple organizations are working on creating novel protection techniques for distribution systems with high penetration of inverter-based DERs. One such innovative method is the use of traveling waves to detect and locate faults. Transmission system protection utilizes this approach, and commercial solutions exist for the transmission system. Using this approach in the distribution system is not straightforward and presents some challenges for implementation. This presentation will discuss the need for using wide-band models to model the traveling wave phenomenon in the distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Online monitoring of rod control systems in combustion engineering pressurized water reactors - 195

Current designs of Pressurized Water Reactors (PWRs) are equipped with control and shutdown rods that are inserted and withdrawn from the reactor core to control reactivity. In Combustion Engineering (CE) plants, these rods are moved using the Control Element Drive Mechanism (CEDM) and controlled by the CEDM Control System (CEDMCS). In the event of system failure, troubleshooting activities can have a substantial impact on plant resources. Furthermore, CEDM component failures have occurred without warning, which has led to increased costs for the plants. These issues, combined with the inherently complex design of the CEDMCS, create a need for an online diagnostics system that can improve system health monitoring, increase diagnostic capabilities, and decrease troubleshooting time. This paper describes an advanced analysis and diagnostics system that monitors the CEDMCS during plant operation and provides critical information to onsite personnel to help detect and prevent problems before they impact normal plant operation. This system uses existing CEDMCS test points to acquire data and needs no modifications to the CEDMCS for implementation. The online monitoring capabilities automatically collect data during normal operation and diagnose failure events, reduce troubleshooting time and provide plant personnel with valuable information which is not currently available. Additionally, the system has built-in features used to streamline routine surveillance testing, collect stationary and movement data on multiple rods simultaneously, automate analysis, and generate reports. This system was developed with input from industry CEDMCS engineers at existing commercial facilities and has been deployed in multiple operating nuclear plants. The system has demonstrated itself to be a valuable tool for CEDMCS health monitoring, not only in reducing required man-power for routine system testing, but also in detected impending coil faults and allowing plant engineers to mitigate system component failures to prevent impending plant shut downs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An architecture for object-oriented intelligent control of power systems in space

A control system for autonomous distribution and control of electrical power during space missions is being developed. This system should free the astronauts from localizing faults and reconfiguring loads if problems with the power distribution and generation components occur. The control system uses an object-oriented simulation model of the power system and first principle knowledge to detect, identify, and isolate faults. Each power system component is represented as a separate object with knowledge of its normal behavior. The reasoning process takes place at three different levels of abstraction: the Physical Component Model (PCM) level, the Electrical Equivalent Model (EEM) level, and the Functional System Model (FSM) level, with the PCM the lowest level of abstraction and the FSM the highest. At the EEM level the power system components are reasoned about as their electrical equivalents, e.g, a resistive load is thought of as a resistor. However, at the PCM level detailed knowledge about the component's specific characteristics is taken into account. The FSM level models the system at the subsystem level, a level appropriate for reconfiguration and scheduling. The control system operates in two modes, a reactive and a proactive mode, simultaneously. In the reactive mode the control system receives measurement data from the power system and compares these values with values determined through simulation to detect the existence of a fault. The nature of the fault is then identified through a model-based reasoning process using mainly the EEM. Compound component models are constructed at the EEM level and used in the fault identification process. In the proactive mode the reasoning takes place at the PCM level. Individual components determine their future health status using a physical model and measured historical data. In case changes in the health status seem imminent the component warns the control system about its impending failure. The fault isolation process uses the FSM level for its reasoning base.

Holmquist, Sven G.↗

Low-cost coding techniques for digital fault diagnosis

Published report discusses fault location properties of arithmetic codes. Criterion for effectiveness of given code is detection probability of local fault by application of checking algorithm to results of entire set of algorithms of processor. Report also presents analysis of arithmetic codes with low-cost check algorithm which possesses partial fault-location properties.

Avizienis, A. A.↗

Advanced Diagnostic and Prognostic Testbed (ADAPT) Testability Analysis Report

As system designs become more complex, determining the best locations to add sensors and test points for the purpose of testing and monitoring these designs becomes more difficult. Not only must the designer take into consideration all real and potential faults of the system, he or she must also find efficient ways of detecting and isolating those faults. Because sensors and cabling take up valuable space and weight on a system, and given constraints on bandwidth and power, it is even more difficult to add sensors into these complex designs after the design has been completed. As a result, a number of software tools have been developed to assist the system designer in proper placement of these sensors during the system design phase of a project. One of the key functions provided by many of these software programs is a testability analysis of the system essentially an evaluation of how observable the system behavior is using available tests. During the design phase, testability metrics can help guide the designer in improving the inherent testability of the design. This may include adding, removing, or modifying tests; breaking up feedback loops, or changing the system to reduce fault propagation. Given a set of test requirements, the analysis can also help to verify that the system will meet those requirements. Of course, a testability analysis requires that a software model of the physical system is available. For the analysis to be most effective in guiding system design, this model should ideally be constructed in parallel with these efforts. The purpose of this paper is to present the final testability results of the Advanced Diagnostic and Prognostic Testbed (ADAPT) after the system model was completed. The tool chosen to build the model and to perform the testability analysis with is the Testability Engineering and Maintenance System Designer (TEAMS-Designer). The TEAMS toolset is intended to be a solution to span all phases of the system, from design and development through health management and maintenance. TEAMS-Designer is the model-building and testability analysis software in that suite.

Ossenfort, John↗

Colorado Potential Geothermal Pathways

This layer contains the weakened basement rocks. Isostatic gravity was utilized to identify structural basin areas, characterized by gravity low values reflecting weakened basement rocks. Together interpreted regional fault zones and basin outlines define geothermal "exploration fairways", where the potential exists for deep, superheated fluid flow in the absence of Pliocene or younger volcanic units.

15 GEOTHERMAL ENERGY↗

Whole program Adaptive Error Detection and Mitigation

Our project investigated methods to detect soft errors in computing systems. Such detection schemes must have low overheads and also generate no false positives. Our solutions focused on control-space error detection based on changing addressing schemes so that faults tend to cascade – rather than being masked. Our solutions also addressed data-space error detection by synthesizing error detectors based on rigorous floating-point error analysis.

42 ENGINEERING↗

Detecting Tooth Damage in Geared Drive Trains

This paper describes a method that was developed to detect gear tooth damage that does not require a priori knowledge of the frequency characteristic of the fault. The basic idea of the method is that a few damaged teeth will cause transient load fluctuations unlike the normal tooth load fluctuations. The method attempts to measure the energy in the lower side bands of the modulated signal caused by the transient load fluctuations. The method monitors the energy in the frequency interval which excludes the frequency of the lowest dominant normal tooth load fluctuation and all frequencies above it. The method reacted significantly to the tooth fracture damage results documented in the Lewis data sets which were obtained from tests of the OH-58A transmission and tests of high contact ratio spiral bevel gears. The method detected gear tooth fractures in all four of the high contact ratio spiral bevel gear runs. Published results indicate other detection methods were only able to detect faults for three out of four runs.

Nachtsheim, Philip R.↗

A System for Fault Management and Fault Consequences Analysis for NASA's Deep Space Habitat

NASA's exploration program envisions the utilization of a Deep Space Habitat (DSH) for human exploration of the space environment in the vicinity of Mars and/or asteroids. Communication latencies with ground control of as long as 20+ minutes make it imperative that DSH operations be highly autonomous, as any telemetry-based detection of a systems problem on Earth could well occur too late to assist the crew with the problem. A DSH-based development program has been initiated to develop and test the automation technologies necessary to support highly autonomous DSH operations. One such technology is a fault management tool to support performance monitoring of vehicle systems operations and to assist with real-time decision making in connection with operational anomalies and failures. Toward that end, we are developing Advanced Caution and Warning System (ACAWS), a tool that combines dynamic and interactive graphical representations of spacecraft systems, systems modeling, automated diagnostic analysis and root cause identification, system and mission impact assessment, and mitigation procedure identification to help spacecraft operators (both flight controllers and crew) understand and respond to anomalies more effectively. In this paper, we describe four major architecture elements of ACAWS: Anomaly Detection, Fault Isolation, System Effects Analysis, and Graphic User Interface (GUI), and how these elements work in concert with each other and with other tools to provide fault management support to both the controllers and crew. We then describe recent evaluations and tests of ACAWS on the DSH testbed. The results of these tests support the feasibility and strength of our approach to failure management automation and enhanced operational autonomy

System Effects Analysis↗

Error detection on quantum computers improving the accuracy of chemical calculations

The ultimate goal of quantum error correction is to achieve the fault-tolerance threshold beyond which quantum computers can be made arbitrarily accurate. This requires extraordinary resources and engineering efforts. We show that even without achieving full fault-tolerance, quantum error detection is already useful on the current generation of quantum hardware. We demonstrate this by executing an end-to-end chemical calculation for the hydrogen molecule encoded in the [[4, 2, 2]] quantum error-detecting code. The encoded calculation with logical qubits significantly improves the accuracy of the molecular ground-state energy.

97 MATHEMATICS AND COMPUTING↗

Detection and Localization of Disconnections in PV Strings Using Spread-Spectrum Time-Domain Reflectometry

This article describes the novel use of spread-spectrum time-domain reflectometry (SSTDR) for detecting and locating disconnection faults in photovoltaic (PV) power plants. We measure strings of cells and full-sized modules to understand how disconnections affect the reflectometry signature. PV modules correspond to reactive loads and disconnections in a PV string and cause distinguishable and measurable changes in SSTDR responses. Disconnection faults are manually introduced and correctly identified and localized applying the proposed technique. The SSTDR technique can detect and locate disconnects through at least eight 36-cell modules. Using the new technique described in this article, we can both detect and locate the disconnections within a 1-ft resolution, on average.

14 SOLAR ENERGY↗

Detection of aseismic creep along the San Andreas fault near Parkfield, California with ERS-1 radar interferometry

The differential interferometric analysis of ERS data from Parkfield (CA) observations revealed the wide area distribution of creep along the moving fault segment of the San Andreas fault over a 15 month interval. The removal of the interferometric phase related to the surface topography was carried out. The fault was clearly visible in the differential interferogram. The magnitude of the tropospheric water vapor phase distortions is greater than the signal and hinders quantitative analysis beyond order of magnitude calculations.

Werner, Charles L.↗

An Integrated Framework for Model-Based Distributed Diagnosis and Prognosis

Diagnosis and prognosis are necessary tasks for system reconfiguration and fault-adaptive control in complex systems. Diagnosis consists of detection, isolation and identification of faults, while prognosis consists of prediction of the remaining useful life of systems. This paper presents a novel integrated framework for model-based distributed diagnosis and prognosis, where system decomposition is used to enable the diagnosis and prognosis tasks to be performed in a distributed way. We show how different submodels can be automatically constructed to solve the local diagnosis and prognosis problems. We illustrate our approach using a simulated four-wheeled rover for different fault scenarios. Our experiments show that our approach correctly performs distributed fault diagnosis and prognosis in an efficient and robust manner.

Bregon, Anibal↗

Potential for Induced Seismicity Related to the Northern California CO2 Reduction Project Pilot Test, Solano County, California

The objective of this technical report is to analyze the potential for induced seismicity due to a proposed small-scale CO{sub 2} injection project in the Montezuma Hills. We reviewed currently available public information, including 32 years of recorded seismic events, locations of mapped faults, and estimates of the stress state of the region. We also reviewed proprietary geological information acquired by Shell, including seismic reflection imaging in the area, and found that the data and interpretations used by Shell are appropriate and satisfactory for the purpose of this report. The closest known fault to the proposed injection site is the Kirby Hills Fault. It appears to be active, and microearthquakes as large as magnitude 3.7 have been associated with the fault near the site over the past 32 years. Most of these small events occurred 9-17 miles (15-28 km) below the surface, which is deep for this part of California. However, the geographic locations of the many events in the standard seismicity catalog for the area are subject to considerable uncertainty because of the lack of nearby seismic stations; so attributing the recorded earthquakes to motion along any specific fault is also uncertain. Nonetheless, the Kirby Hills Fault is the closest to the proposed injection site and is therefore our primary consideration for evaluating the potential seismic impacts, if any, from injection. Our planned installation of seismic monitoring stations near the site will greatly improve earthquake location accuracy. Shell seismic data also indicate two unnamed faults more than 3 miles east of the project site. These faults do not reach the surface as they are truncated by an unconformity at a depth of about 2,000 feet (610 m). The unconformity is identified as occurring during the Oligocene Epoch, 33.9-23.03 million years ago, which indicates that these faults are not currently active. Farther east are the Rio Vista Fault and Midland Fault at distances of about 6 miles (10 km) and 10 miles (16 km), respectively. These faults have been identified as active during the Quaternary (last 1.6 million years), but without evidence of displacement during the Holocene (the last 11,700 years). The stress state (both magnitude and direction) in the region is an important parameter in assessing earthquake potential. Although the available information regarding the stress state is limited in the area surrounding the injection well, the azimuth of the mean maximum horizontal stress is estimated at 41{sup o} and it is consistent with strike-slip faulting on the Kirby Hills Fault, unnamed fault segments to the south, and the Rio Vista Fault. However, there are large variations (uncertainty) in stress estimates, leading to low confidence in these conclusions regarding which fault segments are optimally oriented for potential slip induced by pressure changes. Uncertainty in the stress state can be substantially reduced by measurements planned when wells are drilled at the site. Injection of CO{sub 2} at about two miles depth will result in a reservoir fluid pressure increase, which is greatest at the well and decreases with distance from the well. After the injection stops, reservoir fluid pressures will decrease rapidly. Pressure changes have been predicted quantitatively by numerical simulation models of the injection. Based on these models, the pressure increase on the Kirby Hills Fault at its closest approach to the well due to the injection of 6,000 metric tons of CO{sub 2} would be a few pounds per square inch (psi), which is a tiny fraction of the natural pressure of approximately 5,000 psi at that depth. The likelihood of such a small pressure increase triggering a slip event is very small. It is even more unlikely that events would be induced at the significantly greater depths where most of the recorded earthquakes are concentrated, because it is unlikely that such a small pressure pulse would propagate downwards any appreciable distance. Therefore, in response to the specific question of the likelihood of the CO{sub 2} injection causing a magnitude 3.0 (or larger) event, this preliminary analysis suggests that no such induced or triggered events would be expected. However, it is possible that a fault, too small to be detected by the existing seismic data, yet sufficiently large to cause a magnitude 3 event, could exist in close proximity to the injection point where the pressure increase could cause slippage. However, the existence of such a fault would be detectable in the data planned for collection from the well prior to injection. We do note that natural earthquake events of up to 3.7 in magnitude have occurred in this area and would be expected to occur again regardless of the proposed CO{sub 2} injection.

54 ENVIRONMENTAL SCIENCES↗

On testing stuck-open faults in CMOS combinational circuits

Recently it has been found that a class of failure related to a particular technology (CMOS) cannot be modelled as the conventional stuck-at fault model. These failures change the combinational behavior of CMOS logic gates into a sequential one. Such a failure is modelled as a fault, called the Stuck-Open fault (SOP). The object of this paper is to develop a procedure to detect single SOPs in combinational circuits. It is shown, that in general, tests generated for stuck-at faults when applied in a particular sequence will detect all single SOP faults. In case of single redundancy in the network, the SOP fault on the redundant line cannot be detected. When there is reconvergent fan-out in the network, there is a one-one correspondence between the conditions for stuck-at fault and stuck-open fault detectability.

Chandramouli, R.↗

Common Faults and Their Prioritization in Small Commercial Buildings

This study documents faults that are commonly found in small commercial buildings based on a literature review and discussions with building commissioning experts. It also provides a list of prioritized faults based on an estimation of the prevalence, energy impact, and financial impact of each fault. A total of 39 faults were analyzed for this paper and classified by location, stage, and type. The technical complexity of detecting each type of fault based on typically available information was evaluated for each fault. The annual energy impact (AEI) and annual financial impact (AFI) of each fault were estimated based on available information. Based on these estimates, 20 top priority faults were identified. Seven out of the 20 top priority faults occur in vapor compression systems such as air-conditioning, heat pump, and refrigeration equipment. Nonstandard charging, condenser, and evaporator fouling are the most important faults for this type of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A System for Fault Management for NASA's Deep Space Habitat

NASA's exploration program envisions the utilization of a Deep Space Habitat (DSH) for human exploration of the space environment in the vicinity of Mars and/or asteroids. Communication latencies with ground control of as long as 20+ minutes make it imperative that DSH operations be highly autonomous, as any telemetry-based detection of a systems problem on Earth could well occur too late to assist the crew with the problem. A DSH-based development program has been initiated to develop and test the automation technologies necessary to support highly autonomous DSH operations. One such technology is a fault management tool to support performance monitoring of vehicle systems operations and to assist with real-time decision making in connection with operational anomalies and failures. Toward that end, we are developing Advanced Caution and Warning System (ACAWS), a tool that combines dynamic and interactive graphical representations of spacecraft systems, systems modeling, automated diagnostic analysis and root cause identification, system and mission impact assessment, and mitigation procedure identification to help spacecraft operators (both flight controllers and crew) understand and respond to anomalies more effectively. In this paper, we describe four major architecture elements of ACAWS: Anomaly Detection, Fault Isolation, System Effects Analysis, and Graphic User Interface (GUI), and how these elements work in concert with each other and with other tools to provide fault management support to both the controllers and crew. We then describe recent evaluations and tests of ACAWS on the DSH testbed. The results of these tests support the feasibility and strength of our approach to failure management automation and enhanced operational autonomy.

Fault management↗