Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Evaluation and Analysis of F-16XL Wind Tunnel Data From Static and Dynamic Tests

A series of wind tunnel tests were conducted in the NASA Langley Research Center as part of an ongoing effort to develop and test mathematical models for aircraft rigid-body aerodynamics in nonlinear unsteady flight regimes. Analysis of measurement accuracy, especially for nonlinear dynamic systems that may exhibit complicated behaviors, is an essential component of this ongoing effort. In this report, tools for harmonic analysis of dynamic data and assessing measurement accuracy are presented. A linear aerodynamic model is assumed that is appropriate for conventional forced-oscillation experiments, although more general models can be used with these tools. Application of the tools to experimental data is demonstrated and results indicate the levels of uncertainty in output measurements that can arise from experimental setup, calibration procedures, mechanical limitations, and input errors.

Kim, Sungwan↗

Evaluation and Analysis of F-16XL Wind Tunnel Data from Dynamic Tests

A series of wind tunnel tests were conducted in the NASA Langley Research Center as part of an ongoing effort to develop and test mathematical models for aircraft rigid-body aerodynamics in nonlinear unsteady flight regimes. Analysis of measurement accuracy, especially for nonlinear dynamic systems that may exhibit complicated behaviors, is an essential component of this ongoing effort. In this paper, tools for harmonic analysis of dynamic data and assessing measurement accuracy are presented. A linear aerodynamic model is assumed that is appropriate for conventional forced-oscillation experiments, although more general models can be used with these tools. Application of the tools to experimental data is demonstrated and results indicate the levels of uncertainty in output measurements that can arise from experimental setup, calibration procedures, mechanical limitations, and input errors.

Kim, Sungwan↗

Global Survey and Statistics of Radio-Frequency Interference in AMSR-E Land Observations

Radio-frequency interference (RFI) is an increasingly serious problem for passive and active microwave sensing of the Earth. To satisfy their measurement objectives, many spaceborne passive sensors must operate in unprotected bands, and future sensors may also need to operate in unprotected bands. Data from these sensors are likely to be increasingly contaminated by RFI as the spectrum becomes more crowded. In a previous paper we reported on a preliminary investigation of RFI observed over the United States in the 6.9-GHz channels of the Advanced Microwave Scanning Radiometer (AMSR-E) on the Earth Observing System Aqua satellite. Here, we extend the analysis to an investigation of RFI in the 6.9- and 10.7-GHz AMSR-E channels over the global land domain and for a one-year observation period. The spatial and temporal characteristics of the RFI are examined by the use of spectral indices. The observed RFI at 6.9 GHz is most densely concentrated in the United States, Japan, and the Middle East, and is sparser in Europe, while at 10.7 GHz the RFI is concentrated mostly in England, Italy, and Japan. Classification of RFI using means and standard deviations of the spectral indices is effective in identifying strong RFI. In many cases, however, it is difficult, using these indices, to distinguish weak RFI from natural geophysical variability. Geophysical retrievals using RFI-filtered data may therefore contain residual errors due to weak RFI. More robust radiometer designs and continued efforts to protect spectrum allocations will be needed in future to ensure the viability of spaceborne passive microwave sensing.

microwave remote sensing↗

Diagnostic Techniques to Elucidate the Aerodynamic Performance of Acoustic Liners

In support of Topic A.2.8 of NASA NRA NNH10ZEA001N, the University of Florida (UF) has investigated the use of flow field optical diagnostic and micromachined sensor-based techniques for assessing the wall shear stress on an acoustic liner. Stereoscopic particle image velocimetry (sPIV) was used to study the velocity field over a liner in the Grazing Flow Impedance Duct (GFID). The results indicate that the use of a control volume based method to determine the wall shear stress is prone to significant error. The skin friction over the liner as measured using velocity curve fitting techniques was shown to be locally reduced behind an orifice, relative to the hard wall case in a streamwise plane centered on the orifice. The capacitive wall shear stress sensor exhibited a linear response for a range of shear stresses over a hard wall. PIV over the liner is consistent with lifting of the near wall turbulent structure as it passes over an orifice, followed by a region of low wall shear stress.

June, Jason↗

Wave-Front Error Measurements and Alignment of CLASP2 Telescope with a Dual-Band Pass Cold Mirror Coated Primary Mirror

"Chromospheric LAyer Spectro-Polarimeter (CLASP2)" is the next sounding rocket experiment of the "Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)" that succeeded in observing for the first time the linear polarization spectra in the hydrogen Lyman- line (121.6 nm) and is scheduled to be launched in 2019. In CLASP2, we will carry out full Stokes-vector spectropolarimetric observations in the Mg II h & k lines near 280 nm with the spectro-polarimeter (SP), while imaging observations in the Lyman- line will be conducted with the slitjaw optics (SJ). For the wavelength selection of CLASP2, the primary mirror of the telescope uses a new dual-band pass cold mirror coating targeting both at 121.6 nm and 280 nm. Therefore, we have to perform again the alignment of the telescope after the installation of the recoated primary mirror. Before unmounting the primary mirror from the telescope structure, we measured the wave-front error (WFE) of the telescope. The measured WFE map was consistent with what we had before the CLASP flight, clearly indicating that the telescope alignment has been maintained even after the flight. After the re-coated primary mirror was installed the WFE was measured, and coma aberration was found to be larger. Finally, the secondary mirror shim adjustments were carried out based on the WFE measurements. In CLASP2 telescope, we improved a fitting method of WFE map (applying 8th terms circular Zernike polynomial tting instead of 37th terms circular Zernike fitting) and the improved method enables to achieve better performance than CLASP telescope. Indeed, WFE map obtained after the final shim adjustment indicated that the required specification (< 5:5 m RMS spot radius) that is more stringent than CLASP telescope was met.

chromosphere; polarimetry; sounding rocket↗

Precise Kinematic Positioning with Simultaneous GPS Pseudorange and Carrier Phase Measurements

This paper investigates three precise kinematic positioning techniques with simultaneous GPS pseudorange and carrier phase measurements. These techniques are simple, efficient, and well suited for real-time positioning applications. A simulation/covariance analysis is carried out comparing the relative performance of these techniques. The analysis indicates that GPS carrier phase measurements significantly strengthen kinematic positioning. When wide-area differential GPS for reducing SA clock errors and GPS ephemeris errors is available, a low Earth orbiting satellite can be positioned to 0.5-0.8 m in accuracy (3-D RSS). The accuracy is superior to positioning with pseudorange measurements alone by a factor of 2 to 3. Relative positioning performance and complexity between the three techniques are compared.

['Kinematic↗

(abstract) The 1994 TIMS Airborne Calibration Experiment: Castaic Lake, California

This summary describes the 9 March 1994 TIMS airborne calibration experiment conducted at Castaic Lake, California. TIMS was flown on the NASA/ARC C-130 with the new retractable air fence installed in the TIMS instrument bay. The purpose of this experiment was to determine is the fence would reduce the air turbulence in the TIMS instrument bay, thereby reducing the errors in calibration caused by wind-blast cooling of the blackbody reference sources internal to TIMS. Previous experiments have indicated that the wind blast effect could cause TIMS to over-estimate surface temperatures by more than 10°C. A suite of twelve flight was designed to subject the TIMS/air fence system to different wind conditions and air temperatures. The TIMS flights were supported by a ground-truth team, who measured lake surface temperatures from a boat, and a atmosphere characterization team, who launched an airsonde and measured solar irradiance with a Reagan Sun Photometer.

TIMS↗

CropManage Application for Vineyard Irrigation Decision-Support

CropManage is a free web-application developed by U.C. Cooperative Extension to support evapotranspiration based irrigation scheduling and nutrient management for major specialty crops. Prescribed phenology curves are used to develop daily estimates of canopy cover within a given field, based on days since planting (annual crops) or budbreak (trees, vines). These curves are modulated by a MaxCan parameter representing seasonal maximum canopy cover. Crop development observations can be used to adjust for such factors as weather anomalies or non-standard agronomic practice, as needed. Canopy cover is converted to crop coefficient and combined with reference evapotranspiration to derive daily water consumption. Guidance on crop water requirement is then conveyed to users in terms of system runtime issued on-demand for a given date, largely based on total evapotranspiration since last irrigation event. In this study, CropManage was adapted to vineyards by adding modules accounting for early-season soil moisture depletion and cover crop presence. A crop stress parameter was added to accommodate deficit irrigation practice, allowing the user to specify percentage departure from full water requirement along with start/stop dates. An initial verification exercise was performed on three winegrape vineyards located in California’s Central Coast (2020), North Coast (2020) and Central Valley (2019). Daily crop evapotranspiration was monitored by eddy-covariance fluxtowers. MaxCan was measured by ground and satellite observation. Stress regime was specified by grower practice where available, otherwise stress levels were inferred from applied water records. Mean absolute error and mean bias error of modeled cumulative evapotranspiration were computed with respect to the eddy covariance measurements collected throughout the growing season. Results indicate the modified CropManage water management module performs reasonably well for winegrape. Additional effort is planned to modify the nutrient module for vineyard use.

CropManage↗

Data Fusion of In-Flight Aerothermodynamic Heating Measurements Using Kalman Filtering

On February 18th, 2021, the Mars 2020 entry system successfully delivered the Perseverance rover to the surface of Mars at Jezero Crater. The entry capsule carried instrumentation installed on the heatshield and backshell, named the Mars Entry, Descent, and Landing Instrumentation 2. The instruments included pressure transducers, thermocouples, heat flux gauges, and a radiometer to measure the aerodynamic and aerothermodynamic performance of the entry vehicle. Three of these sensors, a thermocouple plug, heat flux gauge, and a radiometer, were co-located on the backshell. The sensors were exposed to roughly the same aerodynamic heating, but measured these environments in different ways, each with its own set of modeling and measurement error complications. This paper develops a method for blending each of these measurements together in a single algorithm to produce estimates of the aerothermodynamic environments at that backshell location. The approach makes use of the Kalman-Schmidt filter/smoother methodology, where systematic measurement error parameters are modeled as multiplicative states that are estimated by the filter along with the aerothermal states. The results indicate peak convective and radiative heating values of 0.86 and 5.16 W/cm2, respectively, compared to the filter predictive model values of 0.67 and 4.83 W/cm2.

Christopher D Karlgaard↗

Data Fusion of In-Flight Aerothermodynamic Heating Measurements Using Kalman Filtering

On February 18th, 2021, the Mars 2020 entry system successfully delivered the Perseverance rover to the surface of Mars at Jezero Crater. The entry capsule carried instrumentation installed on the heatshield and backshell, named the Mars Entry, Descent, and Landing Instrumentation 2. The instruments included pressure transducers, thermocouples, heat flux gauges, and a radiometer to measure the aerodynamic and aerothermodynamic performance of the entry vehicle. Three of these sensors, a thermocouple plug, heat flux gauge, and a radiometer, were co-located on the backshell. The sensors were exposed to roughly the same aerodynamic heating, but measured these environments in different ways, each with its own set of modeling and measurement error complications. This paper develops a method for blending each of these measurements together in a single algorithm to produce estimates of the aerothermodynamic environments at that backshell location. The approach makes use of the Kalman-Schmidt filter/smoother methodology, where systematic measurement error parameters are modeled as multiplicative states that are estimated by the filter along with the aerothermal states. The results indicate peak convective and radiative heating values of 0.86 and 5.16 W/cm$^2$, respectively, compared to the filter predictive model values of 0.67 and 4.83 W/cm$^2$.

Christopher D Karlgaard↗

Monte Carlo Control Loops for Cosmic Shear Cosmology with DES Year 1

Weak lensing by large-scale structure is a powerful probe of cosmology and of the dark universe. This cosmic shear technique relies on the accurate measurement of the shapes and redshifts of background galaxies and requires precise control of systematic errors. The Monte Carlo Control Loops (MCCL) is a forward modelling method designed to tackle this problem. It relies on the Ultra Fast Image Generator (UFig) to produce simulated images tuned to match the target data statistically, followed by calibrations and tolerance loops. We present the first end-to-end application of this method, on the Dark Energy Survey (DES) Year 1 wide field imaging data. We simultaneously measure the shear power spectrum $C_{\ell}$ and the redshift distribution $n(z)$ of the background galaxy sample. The method includes maps of the systematic sources, Point Spread Function (PSF), an Approximate Bayesian Computation (ABC) inference of the simulation model parameters, a shear calibration scheme, and the fast estimation of the covariance matrix. We find a close statistical agreement between the simulations and the DES Y1 data using an array of diagnostics. In a non-tomographic setting, we derive a set of $C_\ell$ and $n(z)$ curves that encode the cosmic shear measurement, as well as the systematic uncertainty. Following a blinding scheme, we measure the combination of $\Omega_m$, $\sigma_8$, and intrinsic alignment amplitude $A_{\rm{IA}}$, defined as $S_8D_{\rm{IA}} = \sigma_8(\Omega_m/0.3)^{0.5}D_{\rm{IA}}$, where $D_{\rm{IA}}=1-0.11(A_{\rm{IA}}-1)$. We find $S_8D_{\rm{IA}}=0.895^{+0.054}_{-0.039}$, where systematics are at the level of roughly 60\% of the statistical errors. We discuss these results in the context of earlier cosmic shear analyses of the DES Y1 data. Our findings indicate that this method and its fast runtime offer good prospects for cosmic shear measurements with future wide-field surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovery of Weak EXO 2030+375 Outbursts with BATSE

EXO 2030+375 is a 42-second X-ray pulsar orbiting a Be star every 46 days. Previous work using epoch-folded frequency searches over one-day intervals of BATSE data indicated that EXO 2030+375 underwent a 2.5 year period of quiescence from 1993 Sept-1996 March. Improvements in the search method that reduced systematic errors due to aperiodic noise from the nearby black hole candidate Cyg X-1 and sources undergoing Earth occultation, have allowed longer time intervals to be searched, hence increasing BATSE's sensitivity. Using the improved method with four-day intervals, we detect EXO 2030+375 near most of its periastron passages during 1993 Sept-1996 March for most periastron passages during BATSE's nine years in orbit. Earth occultation measurements in the 20-100 keV band, selected with Cyg X-1 was below the Earth's horizon and epoch-folded at EXO 2030+375's orbital period of 46 days also indicate that EXO 2030+375 was active for most of the mission. We will present histories of EXO 2030+375's pulse frequency, pulse flux, and total flux. In addition, we will present results of pulse timing analyses and evidence that EXO 2030+375's outbursts shift in orbital phase.

Wilson, Colleen A.↗

Stochastic Error Cancellation in Analog Quantum Simulation

Analog quantum simulation is a promising path towards solving classically intractable problems in many-body physics on near-term quantum devices. However, the presence of noise limits the size of the system and the length of time that can be simulated. In our work, we consider an error model in which the actual Hamiltonian of the simulator differs from the target Hamiltonian we want to simulate by small local perturbations, which are assumed to be random and unbiased. We analyze the error accumulated in observables in this setting and show that, due to stochastic error cancellation, with high probability the error scales as the square root of the number of qubits instead of linearly. We explore the concentration phenomenon of this error as well as its implications for local observables in the thermodynamic limit. Moreover, we show that stochastic error cancellation also manifests in the fidelity between the target state at the end of time-evolution and the actual state we obtain in the presence of noise. This indicates that, to reach a certain fidelity, more noise can be tolerated than implied by the worst-case bound if the noise comes from many statistically independent sources.

Analog quantum simulation↗

The link evaluation terminal for the advanced communications technology satellite experiments program

The experimental NASA satellite, Advanced Communications Technology Satellite (ACTS), introduces new technology for high throughput 30 to 20 GHz satellite services. Contained in a single communication payload is both a regenerative TDMA system and multiple 800 MHz 'bent pipe' channels routed to spot beams by a switch matrix. While only one mode of operation is typical during any experiment, both modes can operate simultaneously with reduced capability due to sharing of the transponder. NASA-Lewis instituted a ground terminal development program in anticipation of the satellite launch to verify the performance of the switch matrix mode of operations. Specific functions are built into the ground terminal to evaluate rain fade compensation with uplink power control and to monitor satellite transponder performance with bit error rate measurements. These functions were the genesis of the ground terminal's name, Link Evaluation Terminal, often referred to as LET. Connectors are included in LET that allow independent experimenters to run unique modulation or network experiments through ACTS using only the RF transmit and receive portions of LET. Test data indicate that LET will be able to verify important parts of ACTS technology and provide independent experimenters with a useful ground terminal. Lab measurements of major subsystems integrated into LET are presented. Bit error rate is measured with LET in an internal loopback mode.

May, Brian D.↗

The Link Evaluation Terminal for the Advanced Communications Technology Satellite Experiments Program

The experimental NASA satellite, Advanced Communications Technology Satellite (ACTS), introduces new technology for high throughput 30 to 20 GHz satellite services. Contained in a single communication payload is both a regenerative TDMA system and multiple 800 MHz 'bent pipe' channels routed to spot beams by a switch matrix. While only one mode of operation is typical during any experiment, both modes can operate simultaneously with reduced capability due to sharing of the transponder. NASA-Lewis instituted a ground terminal development program in anticipation of the satellite launch to verify the performance of the switch matrix mode of operations. Specific functions are built into the ground terminal to evaluate rain fade compensation with uplink power control and to monitor satellite transponder performance with bit error rate measurements. These functions were the genesis of the ground terminal's name, Link Evaluation Terminal, often referred to as LET. Connectors are included in LET that allow independent experimenters to run unique modulation or network experiments through ACTS using only the RF transmit and receive portions of LET. Test data indicate that LET will be able to verify important parts of ACTS technology and provide independent experimenters with a useful ground terminal. Lab measurements of major subsystems integrated into LET are presented. Bit error rate is measured with LET in an internal loopback mode.

May, Brian D.↗

Discovery of Weak EXO 2030+375 Outbursts With BATSE

EXO 2030+375 is a 42-second X-ray pulsar orbiting a Be star every 46 days. Previous work using epoch-folded frequency searches over 1-day intervals of BATSE data [1] indicated that EXO 2030+375 underwent a 2.5 year period of quiescence from 1993 September-1996 March. Improvements in the search method that reduced systematic errors due to (1) aperiodic noise from the nearby black hole candidate Cyg X-1 and (2) sources undergoing Earth occultation, have allowed longer time intervals to be searched, hence increasing BATSE's sensitivity. Using the improved method with 4-day intervals, we detect EXO 2030+375 near most of its periastron passages during 1993 September-1996 March and for most periastron passages during BATSE's 9 years in orbit. Earth occultation measurements in the 20-100 keV band, selected when Cyg X-1 was below the Earth's horizon and epoch-folded at EXO 2030+375's orbital period of 46 days, also indicate that EXO 2030+375 was active for most of the mission. We will present histories of EXO 2030+375's pulse frequency and pulsed flux. In addition, we will present results of a pulse timing analysis and evidence that EXO 2030+375's outbursts shift in orbital phase.

Wilson, Colleen A.↗

An approach of orthogonalization within the Gram–Schmidt algorithm

In this paper we consider the variants of Gram–Schmidt such as Classical Gram–Schmidt and Modified Gram–Schmidt algorithms. It is shown that for problems of dimension more than two the round-off error of operation q{sub 1}{sup T}q{sub 2} has more propagation in both of algorithms. To cure this difficulty we will present an algorithm, namely Optimized Modified Gram–Schmidt algorithm. Numerical examples indicate the accuracy of this algorithm. We show that this method can improve the loss of orthogonality of the orthogonalization in some ill-conditioned cases.

97 MATHEMATICS AND COMPUTING↗

Tracing and Forecasting Metabolic Indices of Cancer Patients Using Patient-Specific Deep Learning Models

We develop a patient-specific dynamical system model from the time series data of the cancer patient’s metabolic panel taken during the period of cancer treatment and recovery. The model consists of a pair of stacked long short-term memory (LSTM) recurrent neural networks and a fully connected neural network in each unit. It is intended to be used by physicians to trace back and look forward at the patient’s metabolic indices, to identify potential adverse events, and to make short-term predictions. When the model is used in making short-term predictions, the relative error in every index is less than 10% in the L ∞ norm and less than 6.3% in the L 1 norm in the validation process. Once a master model is built, the patient-specific model can be calibrated through transfer learning. As an example, we obtain patient-specific models for four more cancer patients through transfer learning, which all exhibit reduced training time and a comparable level of accuracy. This study demonstrates that this modeling approach is reliable and can deliver clinically acceptable physiological models for tracking and forecasting patients’ metabolic indices.

60 APPLIED LIFE SCIENCES↗