Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Motion tracking in the liver: Validation of a method based on 4D ultrasound using a nonrigid registration technique

Purpose: Treatments like radiotherapy and focused ultrasound in the abdomen require accurate motion tracking, in order to optimize dosage delivery to the target and minimize damage to critical structures and healthy tissues around the target. 4D ultrasound is a promising modality for motion tracking during such treatments. In this study, the authors evaluate the accuracy of motion tracking in the liver based on deformable registration of 4D ultrasound images. Methods: The offline analysis was performed using a nonrigid registration algorithm that was specifically designed for motion estimation from dynamic imaging data. The method registers the entire 4D image data sequence in a groupwise optimization fashion, thus avoiding a bias toward a specifically chosen reference time point. Three healthy volunteers were scanned over several breathing cycles (12 s) from three different positions and angles on the abdomen; a total of nine 4D scans for the three volunteers. Well-defined anatomic landmarks were manually annotated in all 96 time frames for assessment of the automatic algorithm. The error of the automatic motion estimation method was compared with interobserver variability. The authors also performed experiments to investigate the influence of parameters defining the deformation field flexibility and evaluated how well the method performed with a lower temporal resolution in order to establish the minimum frame rate required for accurate motion estimation. Results: The registration method estimated liver motion with an error of 1 mm (75% percentile over all datasets), which was lower than the interobserver variability of 1.4 mm. The results were only slightly dependent on the degrees of freedom of the deformation model. The registration error increased to 2.8 mm with an eight times lower temporal resolution. Conclusions: The authors conclude that the methodology was able to accurately track the motion of the liver in the 4D ultrasound data. The authors believe that the method has potential in interventions on moving abdominal organs such as MR or ultrasound guided focused ultrasound therapy and radiotherapy, pending the method is enabled to run in real-time. The data and the annotations used for this study are made publicly available for those who would like to test other methods on 4D liver ultrasound data.

60 APPLIED LIFE SCIENCES↗

Interindividual variability of arterial impulse response to intravenous injection of nonionic contrast agent (Iohexol) in DCE-CT study

Purpose: It is known that the arterial input function (AIF) in dynamic contrast-enhanced (DCE)-CT differs among patients even for fixed contrast injection protocols. Therefore, a study has been performed to investigate the interindividual variability of the AIF with respect to patient factors (such as weight, height, and age). In addition, it has been demonstrated that the relations from the interindividual variability investigation can be further used for the estimation of AIF for a patient without the requirement of measurement. Methods: DCE-CT data for a cohort of 34 patients with cervical carcinoma were used for the investigation of interindividual variability of the AIF. To dissociate the effect of different durations of contrast injection, the arterial impulse response (AIR) to intravenous contrast injection was calculated and examined for its correlations with these patient factors. An empirical functional form was proposed to model the AIR with temporal intensity of a first pass of contrast agent followed by recirculation and quasiequilibrium state of contrast concentration. Specific features (onset time, peak time, and amplitudes) of the AIR were tested for correlations with the patient factors. Linear regression was applied to cases that show significant strong correlation between the AIR amplitudes and patient factors. The results were then used to predict the AIR for any given patient based on the patient factors. It was shown that using the predicted AIR, the AIF of the patient can be estimated without the requirement of measurement given the injection protocol is known. The method of AIF estimation was tested in DCE-CT data from another group of 14 patients. The efficacy of individually estimated AIF on pharmacokinetic analysis was assessed against the use of measured AIF and population-averaged AIF as the latter is another possible strategy for AIF generation if AIF measurement is not available. Results: It was found that the amplitudes of AIR postonset time were significantly correlated with patient bodyweight at most time points (r<-0.44, P<0.01) except 8-17 s (P>0.01). When the adiabatic tissue homogeneity (ATH) and the Kety models were applied to the pharmacokinetic analysis, the mean percentage errors in kinetic parameter estimates induced by using the estimated AIF instead of the measured one for both models ranged from -4.98% to 11.19%. Conclusions: It was found that there are strong linear relationships between AIR and patient weight; thereby the AIR of a patient can be estimated with patient weight. The proposed method of AIF estimation is potentially applicable in cases where AIF measurement is not possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MPS dose reconstruction for internal emitters: some site-specific issues and approaches

Background: As part of the Million Person Study (MPS), dose reconstructions for internal emitters have been performed for several U.S. facilities where large quantities of radionuclides were handled. The main challenges and dominant sources of potential error in retrospective dose estimates for internally exposed workers have been found to vary from site to site. Here in this paper, we discuss some important issues encountered in dose reconstructions performed for selected MPS sites and the approaches used to address those issues. The focus is on some foundational components of retrospective dose assessments that have received little attention in the literature. Methods: The discussion is built around illustrative exposure data and dose reconstructions for workers at selected facilities addressed in the MPS. Related findings at some non-MPS sites are also discussed. Results: Each of the following items has been found to be a major source of potential error in reconstructed tissue doses for some MPS sites: identification of all dosimetrically important internal emitters; the time pattern of intake; the mode(s) of intake; reliability of bioassay measurements; application of surrogate (coworker) information in lieu of, or in conjunction with, worker-specific monitoring data; the chemical and physical forms of inhaled radionuclide; and the relation of air monitoring data to actual intake. Conclusions: (1) Much of the dose reconstruction effort for internal emitters should be devoted to development of best feasible exposure scenarios. (2) Coworker data should be used to assign exposure scenarios or dose estimates to workers with missing exposure data only if there is compelling evidence of similar coworker exposure. (3) Bioassay data for some radionuclides and periods of operation at MPS sites are of questionable reliability due to sizable uncertainties associated with contamination, recovery, or background issues. (4) Dose estimates derived solely from air monitoring data should be treated as highly uncertain values in the absence of site-specific information demonstrating that the data are reasonably predictive of intake. (5) For intakes known or assumed to be via inhalation, the uncertainty in lung dose typically is much greater than the uncertainty in dose to systemic tissues, when dose estimates are based on urinary excretion data. (6) The lung dose estimate often can be improved through development of site-specific respiratory absorption parameter values. (7) There is generally insufficient site-specific information to justify development of site-specific systemic models.

61 RADIATION PROTECTION AND DOSIMETRY↗

Estimating Carbon Flux Phenology with Satellite-Derived Land Surface Phenology and Climate Drivers for Different Biomes: A Synthesis of AmeriFlux Observations

Carbon Flux Phenology (CFP) can affect the interannual variation in Net Ecosystem Exchange (NEE) of carbon between terrestrial ecosystems and the atmosphere. In this paper, we proposed a methodology to estimate CFP metrics with satellite-derived Land Surface Phenology (LSP) metrics and climate drivers for 4 biomes (i.e., deciduous broadleaf forest, evergreen needleleaf forest, grasslands and croplands), using 159 site-years of NEE and climate data from 32 AmeriFlux sites and MODIS vegetation index time-series data. LSP metrics combined with optimal climate drivers can explain the variability in Start of Carbon Uptake (SCU) by more than 70% and End of Carbon Uptake (ECU) by more than 60%. The Root Mean Square Error (RMSE) of the estimations was within 8.5 days for both SCU and ECU. The estimation performance for this methodology was primarily dependent on the optimal combination of the LSP retrieval methods, the explanatory climate drivers, the biome types, and the specific CFP metric. In conclusion, this methodology has a potential for allowing extrapolation of CFP metrics for biomes with a distinct and detectable seasonal cycle over large areas, based on synoptic multi-temporal optical satellite data and climate data.

54 ENVIRONMENTAL SCIENCES↗

A coupled ground heat flux–surface energy balance model of evaporation using thermal remote sensing observations

Abstract. One of the major undetermined problems in evaporation (ET) retrieval using thermal infrared remote sensing is the lack of a physically based ground heat flux (G) model and its integration within the surface energy balance (SEB) equation. Here, we present a novel approach based on coupling a thermal inertia (TI)-based mechanistic G model with an analytical surface energy balance model, Surface Temperature Initiated Closure (STIC, version STIC1.2). The coupled model is named STIC-TI. The model is driven by noon–night (13:30 and 01:30 local time) land surface temperature, surface albedo, and a vegetation index from MODIS Aqua in conjunction with a clear-sky net radiation sub-model and ancillary meteorological information. SEB flux estimates from STIC-TI were evaluated with respect to the in situ fluxes from eddy covariance measurements in diverse ecosystems of contrasting aridity in both the Northern Hemisphere and Southern Hemisphere. Sensitivity analysis revealed substantial sensitivity of STIC-TI-derived fluxes due to the land surface temperature uncertainty. An evaluation of noontime G (Gi) estimates showed 12 %–21 % error across six flux tower sites, and a comparison between STIC-TI versus empirical G models also revealed the substantially better performance of the former. While the instantaneous noontime net radiation (RNi) and latent heat flux (LEi) were overestimated (15 % and 25 %), sensible heat flux (Hi) was underestimated (22 %). Overestimation (underestimation) of LEi (Hi) was associated with the overestimation of net available energy (RNi−Gi) and use of unclosed surface energy balance flux measurements in LEi (Hi) validation. The mean percent deviations in Gi and Hi estimates were found to be strongly correlated with satellite day–night view angle difference in parabolic and linear pattern, and a relatively weak correlation was found between day–night view angle difference versus LEi deviation. Findings from this parameter-sparse coupled G–ET model can make a valuable contribution to mapping and monitoring the spatiotemporal variability of ecosystem water stress and evaporation using noon–night thermal infrared observations from future Earth observation satellite missions such as TRISHNA, LSTM, and SBG.

Bhattacharya, Bimal K.↗

Ab initio wavenumber accurate spectroscopy : {sup 1}CH{sub 2} and HCN vibrational levels on automatically generated IMLS potential energy surfaces.

We report here calculated J = 0 vibrational frequencies for {sup 1}CH{sub 2} and HCN with root-mean-square error relative to available measurements of 2.0 cm{sup -1} and 3.2 cm{sup -1}, respectively. These results are obtained with DVR calculations with a dense grid on ab initio potential energy surfaces (PESs). The ab initio electronic structure calculations employed are Davidson-corrected MRCI calculations with double-, triple-, and quadruple-{zeta} basis sets extrapolated to the complete basis set (CBS) limit. In the {sup 1}CH{sub 2} case, Full CI tests of the Davidson correction at small basis set levels lead to a scaling of the correction with the bend angle that can be profitably applied at the CBS limit. Core-valence corrections are added derived from CCSD(T) calculations with and without frozen cores. Relativistic and non-Born-Oppenheimer corrections are available for HCN and were applied. CBS limit CCSD(T) and CASPT2 calculations with the same basis sets were also tried for HCN. The CCSD(T) results are noticeably less accurate than the MRCI results while the CASPT2 results are much poorer. The PESs were generated automatically using the local interpolative moving least-squares method (L-IMLS). A general triatomic code is described where the L-IMLS method is interfaced with several common electronic structure packages. All PESs were computed with this code running in parallel on eight processors. The L-IMLS method provides global and local fitting error measures important in automatically growing the PES from initial ab initio seed points. The reliability of this approach was tested for {sup 1}CH{sub 2} by comparing DVR-calculated vibrational levels on an L-IMLS ab initio surface with levels generated by an explicit ab initio calculation at each DVR grid point. For all levels ({approx}200) below 20000 cm{sup -1}, the mean unsigned difference between the levels of these two calculations was 0.1 cm{sup -1}, consistent with the L-IMLS estimated mean unsigned fitting error of 0.3 cm{sup -1}. All L-IMLS PESs used in this work have comparable mean unsigned fitting errors, implying that fitting errors have a negligible role in the final errors of the computed vibrational levels with experiment. Less than 500 ab initio calculations of the energy and gradients are required to achieve this level of accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE IMPACT OF ENHANCED He AND CNONa ABUNDANCES ON GLOBULAR CLUSTER RELATIVE AGE-DATING METHODS

The impact that unrecognized differences in the chemical patterns of Galactic globular clusters (GGCs) have on their relative age determinations is studied. The two most widely used relative age-dating methods, horizontal and vertical, together with the more recent relative MS-fitting method, were carefully analyzed on a purely theoretical basis. The BaSTI library was adopted to perform the present analysis. We find that relative ages derived using the horizontal and vertical methods are largely dependent on the initial He content and heavy element distribution. Unrecognized cluster-to-cluster chemical abundance differences can lead to an error in the derived relative ages as large as {approx}0.5 (or {approx}6 Gyr if an age of 12.8 Gyr is adopted for normalization) and even larger for some extreme cases. It is shown that the relative MS-fitting method is by far the age-dating technique for which undetected cluster-to-cluster differences in the He abundance have less impact. Present results are used in order to pose constraints on the maximum possible spread in the He and CNONa elements abundances on the basis of the estimates-taken from the literature-of the GGCs relative age dispersion obtained with the various relative age-dating techniques. Finally, it is shown that the age-metallicity relation found for young GGCs by the GC Treasury program is a real age sequence and cannot be produced by variations in the He and/or heavy element distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Automatic tracking of implanted fiducial markers in cone beam CT projection images

Purpose: This paper describes a novel method for simultaneous intrafraction tracking of multiple fiducial markers. Although the proposed method is generic and can be adopted for a number of applications including fluoroscopy based patient position monitoring and gated radiotherapy, the tracking results presented in this paper are specific to tracking fiducial markers in a sequence of cone beam CT projection images. Methods: The proposed method is accurate and robust thanks to utilizing the mean shift and random sampling principles, respectively. The performance of the proposed method was evaluated with qualitative and quantitative methods, using data from two pancreatic and one prostate cancer patients and a moving phantom. The ground truth, for quantitative evaluation, was calculated based on manual tracking preformed by three observers. Results: The average dispersion of marker position error calculated from the tracking results for pancreas data (six markers tracked over 640 frames, 3840 marker identifications) was 0.25 mm (at iscoenter), compared with an average dispersion for the manual ground truth estimated at 0.22 mm. For prostate data (three markers tracked over 366 frames, 1098 marker identifications), the average error was 0.34 mm. The estimated tracking error in the pancreas data was < 1 mm (2 pixels) in 97.6% of cases where nearby image clutter was detected and in 100.0% of cases with no nearby image clutter. Conclusions: The proposed method has accuracy comparable to that of manual tracking and, in combination with the proposed batch postprocessing, superior robustness. Marker tracking in cone beam CT (CBCT) projections is useful for a variety of purposes, such as providing data for assessment of intrafraction motion, target tracking during rotational treatment delivery, motion correction of CBCT, and phase sorting for 4D CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First estimation of high-resolution solar photovoltaic resource maps over China with Fengyun-4A satellite and machine learning

Fengyun-4A (FY-4A), which is the latest-generation Chinese geostationary meteorological satellite, measures solar reflection and thermal emission with high temporal, spatial, and spectral resolutions. It is expected to be highly beneficial for solar resource assessment and forecasting in China. This study is the first to estimate, using FY-4A and a random forest model, the global horizontal irradiance (GHI) at a 4-km–15-min spatio-temporal resolution over China, as a means to arrive at a solar photovoltaic (PV) resource map. In terms of GHI estimates, the root mean square error and mean bias error between hourly measured and retrieved values are 147.02 (35.2%), –5.64 W/m 2 (–1.4%), respectively, whereas the values of daily estimates are 29.20 (18.0%), –2.97 W/m 2 (–1.3%). The retrieval accuracy is found much better for instances with solar zenith angles smaller than 60°. Relatively larger errors are found at locations in the Sichuan Basin and northeastern China, which can be attributed to bright surfaces and/or strong cloud transients. With the retrieved irradiance, PV resource is derived through a physical model chain. The annual mean PV resource map suggests that, over most of the west areas, the annual mean effective irradiance exceeds 1700 kWh/m 2 , with the highest value found in Tibet (around 2000 kWh/m 2 per annum). Eastern China has an annual effective irradiance of only 1300–1500 kWh/m 2 . In conclusion, the region with poorest solar resource is the Sichuan Basin (less than 1100 kWh/m 2 per annum).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Time-Resolved Intrafraction Target Translations and Rotations During Stereotactic Liver Radiation Therapy: Implications for Marker-based Localization Accuracy

Purpose: Image guided liver stereotactic body radiation therapy (SBRT) often relies on implanted fiducial markers. The target localization accuracy decreases with increased marker-target distance. This may occur partly because of liver rotations. The aim of this study was to examine time-resolved translations and rotations of liver marker constellations and investigate if time-resolved intrafraction rotational corrections can improve localization accuracy in liver SBRT. Methods and Materials: Twenty-nine patients with 3 implanted markers received SBRT in 3 to 6 fractions. The time-resolved trajectory of each marker was estimated from the projections of 1 to 3 daily cone beam computed tomography scans and used to calculate the translation and rotation of the marker constellation. In all cone beam computed tomography projections, the time-resolved position of each marker was predicted from the position of another surrogate marker by assuming that the marker underwent either (1) the same translation as the surrogate marker; or (2) the same translation as the surrogate marker corrected by the rotation of the marker constellation. The localization accuracy was quantified as the root-mean-square error (RMSE) between the estimated and the actual marker position. For comparison, the RMSE was also calculated when the marker's position was estimated as its mean position for all the projections. Results: The mean translational and rotational range (2nd-98th percentile) was 2.0 mm/3.9° (right-left), 9.2 mm/2.9° (superior-inferior), 4.0 mm/4.0° (anterior-posterior), and 10.5 mm (3-dimensional). Rotational corrections decreased the mean 3-dimensional RMSE from 0.86 mm to 0.54 mm (P<.001) and halved the RMSE increase per millimeter increase in marker distance. Conclusions: Intrafraction rotations during liver SBRT reduce the accuracy of marker-guided target localization. Rotational correction can improve the localization accuracy with a factor of approximately 2 for large marker-target distances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Neutrino Flux prediction at MiniBooNE

The Booster Neutrino Experiment (MiniBooNE) searches for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations using the {Omicron}(1 GeV) neutrino beam produced by the Booster synchrotron at the Fermi National Accelerator Laboratory (FNAL). The Booster delivers protons with 8 GeV kinetic energy (8.89 GeV=c momentum) to a beryllium target, producing neutrinos from the decay of secondary particles in the beam line. We describe the Monte Carlo simulation methods used to estimate the flux of neutrinos from the beamline incident on the MiniBooNE detector for both polarities of the focusing horn. The simulation uses the Geant4 framework for propagating particles, accounting for electromagnetic processes and hadronic interactions in the beamline materials, as well as the decay of particles. The absolute double differential cross sections of pion and kaon production in the simulation have been tuned to match external measurements, as have the hadronic cross sections for nucleons and pions. The statistical precision of the flux predictions is enhanced through reweighting and resampling techniques. Systematic errors in the flux estimation have been determined by varying parameters within their uncertainties, accounting for correlations where appropriate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Technical Note: Introduction of variance component analysis to setup error analysis in radiotherapy

Purpose: The purpose of this technical note is to introduce variance component analysis to the estimation of systematic and random components in setup error of radiotherapy. Methods: Balanced data according to the one-factor random effect model were assumed. Results: Analysis-of-variance (ANOVA)-based computation was applied to estimate the values and their confidence intervals (CIs) for systematic and random errors and the population mean of setup errors. The conventional method overestimates systematic error, especially in hypofractionated settings. The CI for systematic error becomes much wider than that for random error. The ANOVA-based estimation can be extended to a multifactor model considering multiple causes of setup errors (e.g., interpatient, interfraction, and intrafraction). Conclusions: Variance component analysis may lead to novel applications to setup error analysis in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Redshift-dependent RSD bias from intrinsic alignment with DESI Year 1 spectra

ABSTRACT We estimate the redshift-dependent, anisotropic clustering signal in the Dark Energy Spectroscopic Instrument (DESI) Year 1 Survey created by tidal alignments of Luminous Red Galaxies (LRGs) and a selection-induced galaxy orientation bias. To this end, we measured the correlation between LRG shapes and the tidal field with DESI’s Year 1 redshifts, as traced by LRGs and Emission-Line Galaxies. We also estimate the galaxy orientation bias of LRGs caused by DESI’s aperture-based selection, and find it to increase by a factor of seven between redshifts 0.4−1.1 due to redder, fainter galaxies falling closer to DESI’s imaging selection cuts. These effects combine to dampen measurements of the quadrupole of the correlation function (ξ2) caused by structure growth on scales of 10–80 h−1 Mpc by about 0.15 per cent for low redshifts (0.4 < z < 0.6) and 0.8 per cent for high (0.8 < z < 1.1), a significant fraction of DESI’s error budget. We provide estimates of the ξ2 signal created by intrinsic alignments that can be used to correct this effect, which is necessary to meet DESI’s forecasted precision on measuring the growth rate of structure. While imaging quality varies across DESI’s footprint, we find no significant difference in this effect between imaging regions in the Legacy Imaging Survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutrino flux prediction at MiniBooNE

The booster neutrino experiment (MiniBooNE) searches for {nu}{sub {mu}}{yields}{nu}{sub e} oscillations using the O(1 GeV) neutrino beam produced by the booster synchrotron at the Fermi National Accelerator Laboratory). The booster delivers protons with 8 GeV kinetic energy (8.89 GeV/c momentum) to a beryllium target, producing neutrinos from the decay of secondary particles in the beam line. We describe the Monte Carlo simulation methods used to estimate the flux of neutrinos from the beam line incident on the MiniBooNE detector for both polarities of the focusing horn. The simulation uses the Geant4 framework for propagating particles, accounting for electromagnetic processes and hadronic interactions in the beam line materials, as well as the decay of particles. The absolute double differential cross sections of pion and kaon production in the simulation have been tuned to match external measurements, as have the hadronic cross sections for nucleons and pions. The statistical precision of the flux predictions is enhanced through reweighting and resampling techniques. Systematic errors in the flux estimation have been determined by varying parameters within their uncertainties, accounting for correlations where appropriate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting Anomalies in Time Series Using Kernel Density Approaches

This paper introduces a novel anomaly detection approach tailored for time series data with exclusive reliance on normal events during training. Our key innovation lies in the application of kernel-density estimation (KDE) to scrutinize reconstruction errors, providing an empirically derived probability distribution for normal events post-reconstruction. This non-parametric density estimation technique offers a nuanced understanding of anomaly detection, differentiating it from prevalent threshold-based mechanisms in existing methodologies. In post-training, events are encoded, decoded, and evaluated against the estimated density, providing a comprehensive notion of normality. In addition, we propose a data augmentation strategy involving variational autoencoder-generated events and a smoothing step for enhanced model robustness. The significance of our autoencoder-based approach is evident in its capacity to learn normal representation without prior anomaly knowledge. Through the KDE step on reconstruction errors, our method addresses the versatility of anomalies, departing from assumptions tied to larger reconstruction errors for anomalous events. Our proposed likelihood measure then distinguishes normal from anomalous events, providing a concise yet comprehensive anomaly detection solution. The extensive experimental results support the feasibility of our proposed method, yielding significantly improved classification performance by nearly 10% on the UCR benchmark data.

Frehner, Robin↗

Evaluation of Uncertainties in the Anthropogenic SO 2 Emissions in the USA from the OMI Point Source Catalog

Satellite remote sensing is a promising method of monitoring emissions that may be missing in inventories, but the accuracy of these estimates is often not clear. We demonstrate here a comprehensive evaluation of errors in anthropogenic sulfur dioxide (SO 2 ) emission estimates from NASA’s OMI point source catalog for the contiguous US by comparing emissions from the catalog with high-quality emission inventory data over different dimensions including size of individual sources, aggregate vs individual source errors, and potential bias in individual source estimates over time. For sources that are included in the catalog, we find that errors in aggregate (sum of error for all included sources) are relatively low. Errors for individual sources in any given year can be substantial, however, with over- or underestimates in terms of total error ranging from –80 to 110 kt (roughly 10–90th percentile). In this study, we find that these errors are not necessarily random over time and that there can be consistently positive or negative biases for individual sources. We did not find any overall statistical relationship between the degree of isolation of a source and bias, either at a 40 or 70 km scales. For a sub-set of sources where inventory emissions over a radius of 70 km around an OMI detection are larger than twice the emissions within 40 km, the OMI value is consistently overestimated. We find, as expected, that emission sources not included in the catalog are the largest aggregate source of difference between the satellite estimates and inventories, especially in more recent years where source emission magnitudes have been decreasing and note that trends in satellite detections do not necessarily track trends in total emissions. We find that the OMI-based SO 2 emissions are accurate in aggregate, when summed over a number of sources, but must be interpreted more cautiously at the individual source level. Similar analyses would be valuable for other satellite emission estimates; however, in many cases, the appropriate high-quality reference data may need to be generated.

54 ENVIRONMENTAL SCIENCES↗

INJECTION STRAIGHT PULSED MAGNET ERROR TOLERANCE STUDY FOR TOP-OFF INJECTION

NSLS II is designed to work in top-off injection mode. The injection straight includes a septum and four fast kicker magnets. The pulsed magnet errors will excite a betatron oscillation. This paper gives the formulas of each error contribution to the oscillation amplitude at various source points in the ring. These are compared with simulation results. Based on the simple formulas, we can specify the error tolerances on the pulsed magnets with the goal to minimize the injection transient and scale it to similar machines. The NSLS-II is a 3 GeV third generation synchrotron light source under construction at Brookhaven National Laboratory. Due to its short lifetime, NSLS-II storage ring requires the top-off injection (once per minute) during which the stored beam orbit is highly desired as transparent. But the errors, from the SR pulsed magnets at the injection straight - kickers (non-closed injection bump) and pulsed septum (time-dependent stray field), excite a stored beam betatron oscillation. The magnitude of the perturbation can be large disturning some of the user experiments. In 2010 injection straight review, based on the experts experiences in ALS, DIAMOND, SLS and SPEAR, we came to the conclusion that the acceptable oscillation amplitude at the long straight is set as 100 {micro}m (i.e. 0.7 {sigma}x) in horizontal plane and 12 {micro}m, 2.5 {sigma}y, in vertical plane for NSLS II. This paper gives the analysis estimate of the different error source tolerance from the pulse magnets and scales it to our requirements. The result is compared with simulation.

43 PARTICLE ACCELERATORS↗

The parameter-level performance of covariance matrix conditioning in cosmic microwave background data analyses

Empirical estimates of the band power covariance matrix are commonly used in cosmic microwave background (CMB) power spectrum analyses. While this approach easily captures correlations in the data, noise in the resulting covariance estimate can systematically bias the parameter fitting. Conditioning the estimated covariance matrix, by applying prior information on the shape of the eigenvectors, can reduce these biases and ensure the recovery of robust parameter constraints. In this work, we use simulations to benchmark the performance of four different conditioning schemes, motivated by contemporary CMB analyses. The simulated surveys measure the TT, TE, and EE power spectra over the angular multipole range 300 ≤ ℓ ≤ 3500 in Δℓ = 50 wide bins, for temperature map-noise levels of 10, 6.4, and $2\, \mu$K arcmin. We divide the survey data into N real = 30, 50, or 100 uniform subsets. We show the results of different conditioning schemes on the errors in the covariance estimate, and how these uncertainties on the covariance matrix propagate to the best-fitting parameters and parameter uncertainties. The most significant effect we find is an additional scatter in the best-fitting point, beyond what is expected from the data likelihood. For a minimal conditioning strategy, N real = 30, and a temperature map-noise level of 10$\, \mu$K arcmin, we find the uncertainty on the recovered best-fitting parameter to be ×1.3 larger than the apparent posterior width from the likelihood (×1.2 larger than the uncertainty when the true covariance is used). Stronger priors on the covariance matrix reduce the misestimation of parameter uncertainties to $\lt 1{{\ \rm per\ cent}}$. As expected, empirical estimates perform better with higher N real , ameliorating the adverse effects on parameter constraints.

79 ASTRONOMY AND ASTROPHYSICS↗