Random Vibrations

Ares I Zonal Random vibration environments due to acoustic impingement and combustion processes are develop for liftoff, ascent and reentry. Random Vibration test criteria for Ares I Upper Stage pyrotechnic components are developed by enveloping the applicable zonal environments where each component is located. Random vibration tests will be conducted to assure that these components will survive and function appropriately after exposure to the expected vibration environments. Methodology: Random Vibration test criteria for Ares I Upper Stage pyrotechnic components were desired that would envelope all the applicable environments where each component was located. Applicable Ares I Vehicle drawings and design information needed to be assessed to determine the location(s) for each component on the Ares I Upper Stage. Design and test criteria needed to be developed by plotting and enveloping the applicable environments using Microsoft Excel Spreadsheet Software and documenting them in a report Using Microsoft Word Processing Software. Conclusion: Random vibration liftoff, ascent, and green run design & test criteria for the Upper Stage Pyrotechnic Components were developed by using Microsoft Excel to envelope zonal environments applicable to each component. Results were transferred from Excel into a report using Microsoft Word. After the report is reviewed and edited by my mentor it will be submitted for publication as an attachment to a memorandum. Pyrotechnic component designers will extract criteria from my report for incorporation into the design and test specifications for components. Eventually the hardware will be tested to the environments I developed to assure that the components will survive and function appropriately after exposure to the expected vibration environments.

Messaro. Semma↗

Initial Evaluations of LoC Prediction Algorithms Using the NASA Vertical Motion Simulator

Flying near the edge of the safe operating envelope is an inherently unsafe proposition. Edge of the envelope here implies that small changes or disturbances in system state or system dynamics can take the system out of the safe envelope in a short time and could result in loss-of-control events. This study evaluated approaches to predicting loss-of-control safety margins as the aircraft gets closer to the edge of the safe operating envelope. The goal of the approach is to provide the pilot aural, visual, and tactile cues focused on maintaining the pilot's control action within predicted loss-of-control boundaries. Our predictive architecture combines quantitative loss-of-control boundaries, an adaptive prediction method to estimate in real-time Markov model parameters and associated stability margins, and a real-time data-based predictive control margins estimation algorithm. The combined architecture is applied to a nonlinear transport class aircraft. Evaluations of various feedback cues using both test and commercial pilots in the NASA Ames Vertical Motion-base Simulator (VMS) were conducted in the summer of 2013. The paper presents results of this evaluation focused on effectiveness of these approaches and the cues in preventing the pilots from entering a loss-of-control event.

Pilot Cue↗

Comparisons of Cloud In-Situ Microphysical Properties of Deep Convective Clouds to Appendix D/P, Using Data from the HAIC-HIWC and HIWC RADAR I Flight Campaigns

In-situ cloud data from three international flight campaigns is compared to the new Federal Aviation Administration (FAA) Title 14 Code of Federal Regulations Part 33 Appendix D mixed-phase/glaciated environmental envelope (1), and the corresponding identical European Aviation Safety Agency (EASA) CS-25 Appendix P envelope (2) (hereafter "Appendix D/P"). Appendix D/P consists of a temperature-altitude envelope, a 99th percentile total water content (TWC99) envelope at the 17.4 Nm distance scale, a distance factor to estimate TWC99 values at other distance scales, ice crystal median mass diameter (MMD), and recommended liquid water content (LWC) levels in mixed-phase icing conditions. The dataset is from 45 flight missions in 3 tropical locations, with 472 runs in approximately 115 clouds, providing about 29,600 Nm of in-cloud data in deep convection over four targeted temperature intervals: 10, 30, 40, and 50 +5 C. The measurements span altitueds from about 17,000' to 39,000'. The comparisons will serve as a basis for regulatory and industry assessment of the efficacy of Appendix D/P.

Strapp, J. Walter↗

Comparisons of Cloud In-Situ Microphysical Properties of Deep Convective Clouds to Appendix D/P using Data from the HAIC-HIWC and HIWC-RADAR I Flight Campaigns

In-situ cloud data from three international flight campaigns are compared to the Federal Aviation Administration Title 14 Code of Federal Regulations Part 33 Appendix D mixed-phase/glaciated environmental envelope, and the corresponding identical European Aviation Safety Agency CS-25 Appendix P envelope. The appendices consist of a temperature-altitude envelope, a 99th percentile total water content envelope at the 17.4 Nm distance scale, a distance factor for estimation at other distance scales, ice crystal median mass diameter, and recommended liquid water content levels in mixed-phase icing conditions. The data were collected during 54 flights out of one subtropical and two tropical locations, with 472 runs from about 17,000’ to 39,000’ in approximately 115 clouds. The campaigns provide about 29,600 Nm of in situ data in deep convection over four targeted temperature intervals: -10, -30, -40, and -50, all ± 5 C. The dataset is a modern and unique documentation of the ice crystal icing environment, and results described in this article will contribute to regulatory and industry assessment of Appendices D and P.

Ice Crystal Icing↗

Proof Testing Aluminum and Titanium Thin-Walled Tubes for Aerospace Applications

Proof testing aerospace components aids in verifying the structural integrity of flight hardware. This process is often an important step in the certification process for critical parts. Though proof testing is a common practice at NASA and in industry, there is often a need to understand better the effectiveness of proof testing pressure systems discovering cracklike flaws or defects. Often proof tests are used in requirements and in practice as technical rationale for screening critical defects in a part in lieu of performing a non-destructive inspection. The intent of this work is to define proof test failure envelopes for thin-walled tubes composed of two materials: aluminum and titanium. Both materials are common in aerospace thin-walled tubing applications which is why these were the materials chosen for this study. The fracture mechanics software NASGRO was used to perform a parametric study on the effect of defects in thin-walled tubes subjected to proof testing. For both materials, the parameters varied in the NASGRO analyses were aspect ratio, proof test pressure, thickness, diameter, and flaw multiplier. With each case defined as a through crack or failure, the results were then pulled into MATLAB in order to parse through the data and produce failure envelope plots. Failure envelopes were created by meshing a surface in between the minimum proof pressure failing data points. As expected, based on material properties, the plots indicated the aluminum material would fail at much lower proof tests than the titanium. The parametric data and failure envelopes may be used as general qualitative insight on the effectiveness of proof testing thin-walled tubes of similar alloys.

Leah B Davis↗

Theoretical and Experimental Thermal Performance Analysis of Complex Thermal Storage Membrane Containing Bio-Based Phase Change Material (PCM)

Since 2000, an ORNL research team has been testing different configurations of PCM-enhanced building envelop components to be used in residential and commercial buildings. During 2009, a novel type of thermal storage membrane was evaluated for building envelope applications. Bio-based PCM was encapsulated between two layers of heavy-duty plastic film forming a complex array of small PCM cells. Today, a large group of PCM products are packaged in such complex PCM containers or foils containing arrays of PCM pouches of different shapes and sizes. The transient characteristics of PCM-enhanced building envelope materials depend on the quality and amount of PCM, which is very often difficult to estimate because of the complex geometry of many PCM heat sinks. The only widely used small-scale analysis method used to evaluate the dynamic characteristics of PCM-enhanced building products is the differential scanning calorimeter (DSC). Unfortunately, this method requires relatively uniform, and very small, specimens of the material. However, in numerous building thermal storage applications, PCM products are not uniformly distributed across the surface area, making the results of traditional DSC measurements unrealistic for these products. In addition, most of the PCM-enhanced building products contain blends of PCM with fire retardants and chemical stabilizers. This combination of non-uniform distribution and non-homogenous composition make it nearly impossible to select a representative small specimen suitable for DSC tests. Recognizing these DSC limitations, ORNL developed a new methodology for performing dynamic heat flow analysis of complex PCM-enhanced building materials. An experimental analytical protocol to analyze the dynamic characteristics of PCM thermal storage makes use of larger specimens in a conventional heat-flow meter apparatus, and combines these experimental measurements with three-dimensional (3-D) finite-difference modeling and whole building energy simulations. Based on these dynamic tests and modeling, ORNL researchers then developed a simplified one-dimensional (1-D) model of the PCM-enhanced building component that can be easily used in whole-building simulations. This paper describes this experimental-analytical methodology as used in the analysis of an insulation assembly containing a complex array of PCM pouches. Based on the presented short example of whole building energy analysis, this paper describes step-by-step how energy simulation results can be used for optimization of PCM-enhanced building envelopes. Limited results of whole building energy simulations using the EnergyPlus program are presented as well.

25 ENERGY STORAGE↗

Nuclear Graphite - Fracture Behavior and Modeling

Evidence for the graphite fracture mechanism is reviewed and discussed. The roles of certain microstructural features in the graphite fracture process are reported. The Burchell fracture model is described and its derivation reported. The successful application of the fracture model to uniaxial tensile data from several graphites with widely ranging structure and texture is reported. The extension of the model to multiaxial loading scenarios using two criteria is discussed. Initially, multiaxial strength data for H-451 graphite were modeled using the fracture model and the Principle of Independent Action. The predicted 4th stress quadrant failure envelope was satisfactory but the 1st quadrant predictions were not conservative and thus were unsatisfactory. Multiaxial strength data from the 1st and 4th stress quadrant for NBG-18 graphite are reported. To improve the conservatism of the predicted 1st quadrant failure envelope for NBG-18 the Shetty criterion has been applied to obtain the equivalent critical stress intensity factor, KIc (Equi), for each applied biaxial stress ratio. The equivalent KIc value is used in the Burchell fracture model to predict the failure envelope. The predicted 1st stress quadrant failure envelope is conservative and thus more satisfactory than achieved previously using the fracture model combined with the Principle of Independent Action.

36 MATERIALS SCIENCE↗

Termination unit

Cable end section comprises end-parts of N electrical phases/neutral, and a thermally-insulation envelope comprising cooling fluid. The end-parts each comprises a conductor and are arranged with phase 1 innermost, N outermost surrounded by the neutral, electrical insulation being between phases and N and neutral. The end-parts comprise contacting surfaces located sequentially along the longitudinal extension of the end-section. A termination unit has an insulating envelope connected to a cryostat, special parts at both ends comprising an adapter piece at the cable interface and a closing end-piece terminating the envelope in the end-section. The special parts houses an inlet and/or outlet for cooling fluid. The space between an inner wall of the envelope and a central opening of the cable is filled with cooling fluid. The special part at the end connecting to the cryostat houses an inlet or outlet, splitting cooling flow into cable annular flow and termination annular flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fluorescent lighting with aluminum nitride phosphors

A fluorescent lamp includes a glass envelope; at least two electrodes connected to the glass envelope; mercury vapor and an inert gas within the glass envelope; and a phosphor within the glass envelope, wherein the phosphor blend includes aluminum nitride. The phosphor may be a wurtzite (hexagonal) crystalline structure Al.sub.(1-x)M.sub.xN phosphor, where M may be drawn from beryllium, magnesium, calcium, strontium, barium, zinc, scandium, yttrium, lanthanum, cerium, praseodymium, europium, gadolinium, terbium, ytterbium, bismuth, manganese, silicon, germanium, tin, boron, or gallium is synthesized to include dopants to control its luminescence under ultraviolet excitation. The disclosed Al.sub.(1-x)M.sub.xN:Mn phosphor provides bright orange-red emission, comparable in efficiency and spectrum to that of the standard orange-red phosphor used in fluorescent lighting, Y.sub.2O.sub.3:Eu. Furthermore, it offers excellent lumen maintenance in a fluorescent lamp, and does not utilize "critical rare earths," minimizing sensitivity to fluctuating market prices for the rare earth elements.

36 MATERIALS SCIENCE↗

High Performance Residential Housing Units at U.S. Coast Guard Base Kodiak: Preprint

The United States Coast Guard (USCG) constructs residential housing throughout the country using a basic template that must meet the minimum Leadership in Energy and Environmental Design (LEED) Silver criteria or better for the units. In Kodiak, Alaska, USCG is procuring between 24 and 100 residential multi-family housing units. Priorities for the Kodiak project were to reduce overall energyconsumption by at least 20% over existing units, improve envelope construction, and evaluate space heating options. USCG is challenged with maintaining similar existing units that have complicated residential diesel boilers. Additionally, fuel and material costs are high in Kodiak. While USCG has worked to optimize the performance of the housing units with principles of improved buildingenvelope, the engineers realize there are still opportunities for improvement, especially within the heating, ventilation, and air conditioning (HVAC) system and different envelope measures. USCG staff also desires to balance higher upfront project costs for significantly reduced life-cycle costs of the residential units that have an expected lifetime of 50 or more years. To answer thesequestions, this analysis used the residential modeling tool BEoptE+ to examine potential energy- saving opportunities for the climate. The results suggest criteria for achieving optimized housing performance at the lowest cost. USCG will integrate the criteria into their procurement process. To achieve greater than 50% energy savings, USCG will need to specify full 2x 6 wood stud R-21 insulationwith two 2 inches of exterior foam, R-38 ceiling insulation or even wall insulation in the crawl space, and R-49 fiberglass batts in a the vented attic. The air barrier should be improved to ensure a tight envelope with minimal infiltration to the goal of 2.0 ACH50. With the implementation of an air source heat pump for space heating requirements, the combination of HVAC and envelope savings inthe residential unit can save up to 58% in source energy over existing residential units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Transfer in Commercial Buildings Due to Air Leakage: A New Feature in the Online Airtightness Savings Calculator

Air leakage through the building envelopes is responsible for a large amount of energy use. The US Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies states that, in 2010, air infiltration was responsible for 20% of primary energy consumption attributable to the fenestration and building envelopes of commercial buildings. Despite this fact, improving airtightness is not always recognized by commercial building owners, as they have been slow in acknowledging and diminishing the detrimental effects of air leakage on energy use, comfort, indoor air quality, and building material durability.The design and construction industry would benefit from a credible, easy-to-use tool that estimates potential energy and financial savings in a standardized manner so designers and contractors can give building owners compelling reasons to invest in reducing air leakage. In 2016–2017, Oak Ridge National Laboratory, the National Institute of Standards and Technology, the Air Barrier Association of America, and the US-China Clean Energy Research Center for Building Energy Efficiency collaborated to develop an online calculator. This user-friendly calculator is free to the public and uses the simulation results of the whole building energy simulation tool EnergyPlus and the airflow simulation tool CONTAM. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. Four more commercial building types were also added to the existing database of three building types as part of this update. This paper describes the procedure used to calculate moisture transfer due to air leakage and provides examples that demonstrate the moisture transfer for each of the seven commercial building types that are currently part of the calculator.

Shrestha, Som↗

Partial discharge detector

A partial discharge (PD) detection system includes a PD sensor configured to sense a PD event of an electrical system and to generate a sensor signal in response to the PD event. An envelope generator is coupled to receive the sensor signal from the PD sensor. The envelope generator extracts an envelope signal from the sensor signal. A digitizer is configured to convert the envelope signal to a digital representation of the PD event.

Karin, Todd↗

User Friendly Web-Based Tool to Assess the Energy Efficiency and Durability of Residential Wall Retrofits

According to the U.S. Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies, building envelope wall energy loss in the United States accounts for about 5.9 x 1010 kWh or 2 quads of energy annually, costing homeowners and occupants billions of dollars. Enclosure retrofits targeting these losses can save significant energy, reduce greenhouse gas emissions, and save occupants millions of dollars over time. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established, represent approximately 68 percent of the residential building stock in the country, often having significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation have heating and cooling losses that can represent a substantial portion of utility bills.High-performance building envelope retrofit systems are rarely selected for retrofit applications. Current solutions are expensive and/or unfamiliar to many designers, builders, contractors, and code officials and therefore are perceived as risky. The dominant perceived risk is durability specifically related to condensation and moisture accumulation in the building envelope component.The Building Science Advisor (BSA) is a rule-based expert system web-based tool that was originally developed to assist building professionals in designing energy efficient and durable wall systems for new construction. With the present focus being placed on upgrading the existing building stock, a retrofit module has been developed that, based on the location, existing construction, and planned retrofit strategy, provides recommendations on how to address the retrofit in a manner that will perform in accordance with IECC 2018 building code and not create a durability problem. This paper will describe the development of this tool and demonstrate its features and capabilities.

Desjarlais, Andre Omer↗

Interaction of a nonlinear spin-wave and magnetic soliton in a uniaxial anisotropic ferromagnet

We study the interaction of a nonlinear spin-wave and magnetic soliton in a uniaxial anisotropic ferromagnet. By means of a reasonable assumption and a straightforward Darboux transformation one- and two-soliton solutions in a nonlinear spin-wave background are obtained analytically, and their properties are discussed in detail. On the background of a nonlinear spin-wave the amplitude of the envelope soliton has the spatial and temporal period, and soliton can be trapped only in space. The amplitude and wave number of spin-wave have the different contribution to the width, velocity, and amplitude of soliton solutions. The envelope of solution hold the shape of soliton, and the amplitude of each envelope soliton keeps invariability before and after collision which shows the elastic collision of two envelope soliton on the background of a nonlinear spin-wave.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Methodology for defining intermediate level waste package characteristics that ensure criticality safety in a geological disposal facility - 14599

Radioactive Waste Management (RWM) is responsible for implementing geological disposal of the UK's higher activity radioactive wastes. These wastes include fissile nuclides and, therefore, demonstration of the criticality safety of the wastes under disposal conditions forms an important component of RWM's disposal system safety case. The basis for ensuring criticality safety of intermediate level waste (ILW) packages is to specify controls on the fissile material content of individual packages through the application of deterministic criticality safety assessments (CSAs). The approach is defined and controlled through RWM's Disposability Assessment process, which aims to ensure that: criticality is prevented during waste package transport to a GDF; the risk of criticality is tolerable and as low as reasonably practicable (ALARP) during GDF operations; and the likelihood and consequences of criticality arising from the evolution of waste packages after GDF closure are low. The most restrictive phase determines the package fissile material limit and, until now, in many cases the GDF post-closure phase has provided the most restrictive limit. Currently, the GDF post-closure limits are derived deterministically using highly stylised and conservative assumptions about fissile material accumulations occurring on very long timescales into the future. RWM, waste producers and regulators do not currently consider this approach to be yielding an appropriate balance of risk. Therefore, RWM is modifying the process for setting fissile material limits on ILW packages by making use of the outcomes of its recent research projects to establish the likelihood of post-closure criticality in a GDF and the consequences of hypothetical post-closure criticality events (presented in companion papers). This paper presents the revised methodology, which is based on the requirement that criticality in a GDF can be demonstrated to be of low and tolerable consequences with regard the performance of a GDF. A probabilistic 'low-likelihood package envelope' is proposed that establishes the packaging and disposal facility conditions under which post-closure criticality is considered to be of low likelihood and low consequence. The bounding conditions for establishing the extent of the package envelope have been evaluated through application of the methodologies and models developed in RWM's Likelihood of Criticality research project. It is expected that the vast majority of ILW packages would meet the package envelope requirements. The methodology also allows the use of other options, such as deterministic CSAs, for waste packages that fall outside the low-likelihood package envelope. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Parametric and sensitivity analysis of a PCM-integrated wall for optimal thermal load modulation in lightweight buildings

Load modulation in buildings is becoming increasingly important due to growing disparity in energy demand during peak and off-peak hours. Integrating phase change material (PCM) in building envelopes and using a controlled precooling strategy can provide substantial thermal load modulation; however, it may greatly increase the total energy use. Previous studies have employed PCM in building envelopes primarily for energy savings and, to some extent, peak load shedding and shifting. However, the load modulation capacity of a PCM-integrated envelope has not been well explored in the literature. In this study, we perform an extensive parametric and sensitivity analysis on PCM-integrated lightweight building walls and examine the combinatory effects of various PCM parameters on thermal load modulation and wall-related heat gains in buildings. Using numerical simulations, we investigate eight PCM parameters: PCM location in the wall, transition temperature, thickness, latent heat, transition range, density, specific heat, and thermal conductivity. Here, we evaluate their impact and relative importance to achieve maximum load modulation in buildings without compromising occupants’ thermal comfort or total energy use. The results show that the optimized PCM proposed in this study can completely invert the transient heat gain profile of the wall, providing up to 70% reduction of wall-related heat gain during peak hours without a major increase in the cumulative heat gain.

42 ENGINEERING↗

Failure criteria of unidirectional carbon fiber reinforced polymer composites informed by a computational micromechanics model

Failure prediction for carbon fiber reinforced polymer (CFRP) composites has been a longstanding challenge. In this paper, we address this challenge by first applying a well-established computational micromechanics model based on representative volume element to predict the failure envelopes of unidirectional (UD) CFRP composites. Then, these failure envelopes are compared with the classical failure criteria. We have evaluated the performances of these failure criteria and identified the aspects for further improvement in their accuracies for the UD CFRP composites studied herein. Based on the failure mechanisms from computational analyses and the comparisons between predicted failure envelopes and classical failure criteria, a new set of homogenized failure criteria is proposed. Additionally, the newly proposed failure criteria show significant improvement according to our computational and experimental results. Furthermore, we have compared the proposed failure criteria with existing experimental data and computational results available in the literature for different types of composites. Good agreements are generally observed.

36 MATERIALS SCIENCE↗

Comparative study of air-conditioning energy use of four office buildings in China and USA

Energy use in buildings has great variability. In order to design and operate low energy buildings as well as to establish building energy codes and standards and effective energy policy, it is crucial to understand and quantify key factors influencing building energy performance. Here, this study investigates air-conditioning (AC) energy use of four office buildings in four locations: Beijing, Taiwan, Hong Kong, and Berkeley. Building simulation was employed to quantify the influences of key factors, including climate, building envelope and occupant behavior. Through simulation of various combinations of the three influencing elements, it is found that climate can lead to AC cooling consumption differences by almost two times, while occupant behavior resulted in the greatest differences (of up to three times) in AC cooling consumption. The influence of occupant behavior on AC energy consumption is not homogeneous. Under similar climates, when the occupant behavior in the building differed, the optimized building envelope design also differed. In conclusion, the optimal building envelope should be determined according to the climate as well as the occupants who use the building.