Performance of a Dynamically Controlled Inverter in a Photovoltaic System Interconnected with a Secondary Network Distribution System

In 2008, a 300 kW{sub peak} photovoltaic (PV) system was installed on the rooftop of the Colorado Convention Center (CCC). The installation was unique for the electric utility, Xcel Energy, as it had not previously permitted a PV system to be interconnected on a building served by the local secondary network distribution system (network). The PV system was installed with several provisions; one to prevent reverse power flow, another called a dynamically controlled inverter (DCI), that curtails the output of the PV inverters to maintain an amount of load supplied by Xcel Energy at the CCC. The DCI system utilizes current transformers (CTs) to sense power flow to insure that a minimum threshold is maintained from Xcel Energy through the network transformers. The inverters are set to track the load on each of the three phases and curtail power from the PV system when the generated PV system current reaches 95% of the current on any phase. This is achieved by the DCI, which gathers inputs from current transformers measuring the current from the PV array, Xcel, and the spot network load. Preventing reverse power flow is a critical technical requirement for the spot network which serve this part of the CCC. The PV system was designed with the expectation that the DCI system would not curtail the PV system, as the expected minimum load consumption was historically higher than the designed PV system size. However, the DCI system has operated many days during the course of a year, and the performance has been excellent. The DCI system at the CCC was installed as a secondary measure to insure that a minimum level of power flows to the CCC from the Xcel Energy network. While this DCI system was intended for localized control, the system could also reduce output percent if an external smart grid control signal was employed. This paper specifically focuses on the performance of the innovative design at this installation; however, the DCI system could also be used for new s- art grid-enabled distribution systems where renewables power contributions at certain conditions or times may need to be curtailed.

14 SOLAR ENERGY↗

Comparing Advanced Bipolar Membranes for High-Current Electrodialysis and Membrane Electrolysis

Advanced bipolar membranes (BPMs) with low water-dissociation overpotential (ηwd) may enable new electrochemical technologies for electrolysis, fuel cells, acid–base synthesis, brine remediation, lithium-battery recycling, and cement production. However, these advanced BPMs have only been demonstrated in BPM water electrolysis (BPMWE) configurations where the BPM is under static compression by the porous-transport layers. It is important to study these BPMs in applications like electrodialysis where large degrees of static compression are not possible. We present a BPM electrodialysis (BPMED) platform to measure water-dissociation overpotential (ηwd) and compare BPMWE and BPMED systems. We show advanced BPMs with half the ηwd compared to commercial BPMs for BPMED while maintaining ∼90% current efficiency from 0.05–0.5 A cm–2. The BPMED ηwd values are, however, about 0.2 V higher at 0.5 A cm–2 than those for BPMWE. Regardless, these results show that BPMs developed and optimized in BPMWE applications are well-suited for next-generation high-current-density BPMED technologies.

Vulpin, Olivia T↗

Annual Waste Minimization Summary Report Calendar Year 2007

This report summarizes the waste minimization efforts undertaken by National Security Technologies, LLC (NSTec), for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO), during calendar year (CY) 2007. This report was developed in accordance with the requirements of the Nevada Test Site (NTS) Resource Conservation and Recovery Act (RCRA) Permit (number NEV HW0021), and as clarified in a letter dated April 21, 1995, from Paul Liebendorfer of the Nevada Division of Environmental Protection to Donald Elle of the U.S. Department of Energy, Nevada Operations Office. The NNSA/NSO Pollution Prevention (P2) Program establishes a process to reduce the volume and toxicity of waste generated by the NNSA/NSO and ensures that proposed methods of treatment, storage, and/or disposal of waste minimize potential threats to human health and the environment. The following information provides an overview of the P2 Program, major P2 accomplishments during the reporting year, a comparison of the current year waste generation to prior years, and a description of efforts undertaken during the year to reduce the volume and toxicity of waste generated by the NNSA/NSO.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Waste Minimization Summary Report, Calendar Year 2009

This report summarizes the waste minimization efforts undertaken by National Security Technologies, LLC, for the U. S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO), during calendar year 2009. This report was developed in accordance with the requirements of the Nevada Test Site Resource Conservation and Recovery Act Permit (No. NEV HW0021), and as clarified in a letter dated April 21, 1995, from Paul Liebendorfer of the Nevada Division of Environmental Protection to Donald Elle of the U.S. Department of Energy, Nevada Operations Office. The NNSA/NSO Pollution Prevention (P2) Program establishes a process to reduce the volume and toxicity of waste generated by NNSA/NSO activities and ensures that proposed methods of treatment, storage, and/or disposal of waste minimize potential threats to human health and the environment. The following information provides an overview of the P2 Program, major P2 accomplishments during the reporting year, a comparison of the current year waste generation to prior years, and a description of efforts undertaken during the year to reduce the volume and toxicity of waste generated by NNSA/NSO.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapid doubling of the critical current of YBa{sub 2}Cu{sub 3}O{sub 7−δ} coated conductors for viable high-speed industrial processing

We demonstrate that 3.5-MeV oxygen irradiation can markedly enhance the in-field critical current of commercial second generation superconducting tapes with an exposure time of just 1 s per 0.8 cm{sup 2}. The speed demonstrated here is now at the level required for an industrial reel-to-reel post-processing. The irradiation is made on production line samples through the protective silver coating and does not require any modification of the growth process. From TEM imaging, we identify small clusters as the main source of increased vortex pinning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electricity generation by Pyrococcus furiosus in microbial fuel cells operated at 90°C

ABSTRACT Hyperthermophiles are microorganisms that thrive in extremely hot environments with temperatures near and even above 100°C. They are the most deeply rooted microorganisms on phylogenetic trees suggesting they may have evolved to survive in the early hostile earth. The simple respiratory systems of some of these hyperthermophiles make them potential candidates to develop microbial fuel cells (MFC) that can generate power at temperatures approaching the boiling point. We explored extracellular electron transfer in the hyperthermophilic archaeon Pyrococcus furiosus ( Pf ) by studying its ability to generate electricity in a two‐chamber MFC. Pf growing in defined medium functioned as an anolyte in a MFC operated at 90°C, generating a maximum current density of 2 A m −2 and a peak power density of 225 mW m −2 without the addition of any external redox mediator. Electron microscopy and electrochemical impedance spectroscopy of the anode with the attached Pf biofilm demonstrated bio‐electrochemical behavior that led to electricity generation in the MFC via direct electron transfer. This proof of concept study reveals for the first time that a hyperthermophile such as Pf can generate electricity in MFC at extreme temperatures. Biotechnol. Bioeng. 2017;114: 1419–1427. © 2017 Wiley Periodicals, Inc.

Sekar, Narendran↗

Physics of E × B discharges relevant to plasma propulsion and similar technologies

This paper provides perspectives on recent progress in understanding the physics of devices in which the external magnetic field is applied perpendicular to the discharge current. This configuration generates a strong electric field that acts to accelerate ions. The many applications of this set up include generation of thrust for spacecraft propulsion and separation of species in plasma mass separation devices. These “E × B” plasmas are subject to plasma–wall interaction effects and to various micro- and macroinstabilities. In many devices we also observe the emergence of anomalous transport. This perspective presents the current understanding of the physics of these phenomena and state-of-the-art computational results, identifies critical questions, and suggests directions for future research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heritage Park Facilities PV Project

Project Objective: To procure a photovoltaic array (PV) system which will generate approximately 256kW of power to be used for the operations of the Aquatic Complex and the adjacent Senior Facility at the Heritage Park. This project complies with the EERE’s work and objectives by promoting the development and deployment of an energy system that will provide current and future generations with clean, efficient, affordable, and reliable energy.

14 SOLAR ENERGY↗

From Nucleons to Nuclei: Enabling Discovery for Neutrinos, Dark Matter and More

Neutrino interaction uncertainties are a limiting factor in current and next generation experiments probing the fundamental physics of neutrinos, a unique window on physics beyond the Standard Model. Our understanding of the elementary neutrino-nucleon amplitudes at the heart of the neutrino interaction program relies on experiments from an earlier age whose statistical and systematic precision are insufficient for current needs. The workshop brings together physicists with a diverse range of expertise to discuss the status of neutrino-nucleus scattering and to explore (i) the quantitative impact of better constraints on the elementary amplitudes; (ii) the scientific impact of a new hydrogen or deuterium target experiment; (iii) the optimal design and technical feasibility of a new hydrogen or deuterium target experiment; and (iv) complementary constraints on the elementary amplitudes from other methods. The tools and techniques required for understanding neutrino-nucleus interactions are common to many problems at the interface of particle and nuclear physics. The workshop will discuss new developments and prospects for related topics and new physics searches, including dark matter interactions with the Standard Model and neutrinoless double beta decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Engineering Concepts to High Energy Density Li-S Batteries

Li-S batteries (LSBs) with energy densities > 500 Wh/kg @ C/5 and >1000 cycles, cycle life operating over wide temperatures has been identified to be critical for meeting the global energy demands. Progress is however, very much limited due to several major hurdles related to the following: (a) poor Li' reaction kinetics (conductivity/diffusivity) enabling full reversible S conversion to Li2S, (b) inferior electron (e) conductivity, specific capacity and cycle life due to electrolyte soluble species of polysulfides (PSs) formed with the reaction of Li ions with sulfur migrating to anode, (c) unstable solid electrolyte interphase (SEI) formation and finally, (d) dendrites that are formed on the Li metal anode severely limiting the cycle life due to polarization at the solid/liquid interfaces causing safety, inferior capacity, energy density, rate, and cycle life issues. Creation of a fully functional economical ≤$80/kWh, high energy density LSBs is vital for enabling its widespread commercial deployment and use in current and next generation electric vehicles.

25 ENERGY STORAGE↗

Adiabatic and isothermal configurations for Re 4 Si 7 transverse thermoelectric power generators

We report that transverse thermoelectric generators (TTEGs) have the potential to overcome two challenging problems that limit the commercial application of classical thermoelectric generators (TEGs): the significant irreversible efficiency losses in the contacts and the thermal degradation of the contacts at the hot end. TTEGs are built from a single material that can generate a thermoelectric current in a direction that is orthogonal to a temperature gradient. They only require a single set of contacts that are displaced away from the hot end. Here, we experimentally explore the device design considerations for optimizing the performance of this far less explored class of thermal-to-electric generation devices. We fabricate Re 4 Si 7 TTEGs and show that there is no measurable loss in efficiency with a single set of contacts that are midway between the hot and cold ends. We show that a new effect must be considered: the appearance of transverse thermal gradients that lead to significant differences between the performance of TTEGs implemented in isothermal and adiabatic geometries. The isothermal TTEG configuration leads to much higher device efficiencies. Overall, this work highlights how different the design of TTEGs is from that of conventional TEGs and the importance of controlling the device geometry for optimum waste heat recovery.

30 DIRECT ENERGY CONVERSION↗

Measurements of Turbulence at Two Tidal Energy Sites in Puget Sound, WA

Field measurements of turbulence are pre- sented from two sites in Puget Sound, WA (USA) that are proposed for electrical power generation using tidal current turbines. Rapidly sampled data from multiple acoustic Doppler instruments are analyzed to obtain statistical mea- sures of fluctuations in both the magnitude and direction of the tidal currents. The resulting turbulence intensities (i.e., the turbulent velocity fluctuations normalized by the harmonic tidal currents) are typically 10% at the hub- heights (i.e., the relevant depth bin) of the proposed turbines. Length and time scales of the turbulence are also analyzed. Large-scale, anisotropic eddies dominate the energy spectra, which may be the result of proximity to headlands at each site. At small scales, an isotropic turbulent cascade is observed and used to estimate the dissipation rate of turbulent kinetic energy. Data quality and sampling parameters are discussed, with an emphasis on the removal of Doppler noise from turbulence statistics.

16 TIDAL AND WAVE POWER↗

Dark matter and EWSB naturalness in unified SUSY models

The relationship between the degree of fine-tuning in Electroweak Symmetry Breaking (EWSB) and the discoverability of dark matter in current and next generation direct detection experiments is investigated in the context of two unified Supersymmetry scenarios: the Constrained Minimal Supersymmetric Standard Model (CMSSM) and models with Non-Universal Higgs Masses (NUHM). Attention is drawn to the mechanism(s) by which the relic abundance of neutralino dark matter is suppressed to cosmologically viable values. After a summary of Amsel, Freese, and Sandick (2011), results are updated to reflect current constraints, including the discovery of a new particle consistent with a Standard Model-like Higgs boson. We find that a Higgs mass of {approx} 125 GeV excludes the least fine-tuned CMSSM points in our parameter space and that remaining viable models may be difficult to probe with next generation direct dark matter searches. Relatively low fine-tuning and good direct detection prospects are still possible in NUHM scenarios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production of High Energy Tail Electrons by Electron Bernstein Waves during the Current Start-up Discharges in the LATE Device

Toroidal plasma current is started and ramped up by injecting microwave power in the electron cyclotron range of frequency without induction in the LATE device. Radial scanning with hard X-ray pulse height analysis reveals the production of high energy electrons with average energy {approx}100 keV in the radial region from R = 28 cm to 40.5 cm, which are heated by electron Bernstein wave. The radial profile of photon counts in the energy range from 25 to 200 keV is very similar to that of perpendicular pressure obtained by magnetic measurement and equilibrium analysis, suggesting that a significant portion of trapped electrons exists outside the last closed flux surface. The plasma current inside the LCFS is carried mainly by passing electrons, while some portion of the outside current may be generated as a result of the toroidal precession of trapped electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Next Generation Nuclear Plant Project Technology Development Roadmaps: The Technical Path Forward for 750–800°C Reactor Outlet Temperature

This document presents the NGNP Critical PASSCs and defines their technical maturation path through Technology Development Roadmaps (TDRMs) and their associated Technology Readiness Levels (TRLs). As the critical PASSCs advance through increasing levels of technical maturity, project risk is reduced and the likelihood of within-budget and on-schedule completion is enhanced. The current supplier-generated TRLs and TDRMs for a 750–800°C reactor outlet temperature (ROT) specific to each supplier are collected in Appendix A.

42 ENGINEERING↗

2008 Geothermal Technologies Market Report

This report describes market-wide trends for the geothermal industry throughout 2008 and the beginning of 2009. It begins with an overview of the GTP’s involvement with the geothermal industry and recent investment trends for electric generation technologies. The report next describes the current state of geothermal power generation and activity within the United States, costs associated with development, financing trends, an analysis of the levelized cost of energy (LCOE), and a look at the current policy environment. The report also highlights trends regarding direct use of geothermal energy, including GHPs.† The final sections of the report focus on international perspectives, employment and economic benefits from geothermal energy development, and potential incentives in pending national legislation.

Geothermal, Market Report↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗