Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Transmissive microfluidic active cooling for concentrator photovoltaics

We present the design, fabrication, characterization, and field testing of transmissive active cooling for use in a point-focus spectrum-splitting hybrid concentrator photovoltaics/thermal (CPV/T) system. Seven parallel-path 100 μm thick microchannels are made using polydimethylsiloxane and attached to a CPV module containing a 6 × 6 array of 5.5 mm transmissive CPV cells on a sapphire substrate. Water is flowed through the microchannels to actively cool the CPV cells. The total transmittance of the CPV module reduces by 5.2% with the addition of the active cooling microchannels, relative to the module transmission with no microchannels. The peak cell temperature is measured as 69 °C with a thermal resistance of 9.35 K/W at 157 suns, well below the 110 °C maximum allowed temperature. A maximum flowrate of 16.7 g/s is achieved from a 13 psi pressure drop across the microchannels and manifold assembly. The flow characteristics within each microfluidic channel show maximum fluid velocity of 4.3 m/s (Re = 953) with a calculated convection coefficient of 1.7 × 10 4 W/m 2 K (Nu = 5.36). The CPV/T module and cooling system performance was validated during week-long outdoor tests under varying solar conditions up to 250 suns using a 2.7 m 2 parabolic dish collector mounted to a two-axis tracking system.

14 SOLAR ENERGY↗

Micro-environmental control for efficient local cooling

Micro-environment is hereby defined as the air space and environment around a person that directly impacts his/her thermal sensation. Most existing HVAC systems condition the air of the entire room including the unoccupied space, which leaves a big potential to save energy. This study aims at evaluating the performance of three existing air terminal devices (ATDs) to locally remove enough heat from the micro-environment to manage the thermal balance so as not to sacrifice thermal comfort when the ambient unoccupied space temperature is increased by 2.2 °C from 23.9 °C to 26.1 °C in the summer to reduce the external cooling load. A computational fluid dynamics (CFD) model was developed, validated by full-scale chamber tests and applied to evaluate different configurations of the ATDs for local cooling. Results show that the predicted performance agreed well with the measurements, and the selected ATD, with only 50 W cooling power, was always able to remove a sufficient amount of heat from the microenvironment in a room of raised temperature, when the manikin was moved inside a semicircle movement range. The cooling performance of the jet was increased more by increasing the supply air flow rate than reducing the supply temperature and was highly dependent on the shooting angle. Finally, the heat flux from the manikin surface is very sensitive to the surface temperature and furniture placement, and proper specification of the surface temperature is crucial for the CFD simulation to match the measured results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A thermodynamic analysis of a novel bidirectional district heating and cooling network

In this study, we evaluate an ambient, bidirectional thermal network, which uses a single circuit for both district heating and cooling. When in net more cooling is needed than heating, the system circulates from a central plant in one direction. When more heating is needed, the system circulates in the opposite direction. A large benefit of this design is that buildings can recover waste heat from each other directly. We analyze the thermodynamic performance of the bidirectional system. Because the bidirectional system represents the state-of-the-art in design for district systems, its peak energy efficiency represents an upper bound on the thermal performance of any district heating and cooling system. However, because any network has mechanical and thermal distribution losses, we develop a diversity criterion to understand when the bidirectional system may be a more energy-efficient alternative to modern individual-building systems. We show that a simple model of a low-density, high-distribution loss network is more efficient than aggregated individual buildings if there is at least 1 unit of cooling energy per 5.7 units of simultaneous heating energy (or vice versa). We apply this criterion to reference building profiles in three cities to look for promising clusters.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The reservoir network: A new network topology for district heating and cooling

Thermal district networks are effective solutions to substitute fossil fuels with renewable energy sources for heating and cooling. Moreover, thermal networking of buildings allows energy efficiency to be further increased. The waste heat from cooling can be reused for heating in thermal district systems. Because of bidirectional energy flows between prosumers, thermal networks require new hydraulic concepts. In this work, we present a novel network topology for simultaneous heating and cooling: the reservoir network. The reservoir network is robust in operation due to hydraulic decoupling of transfer stations, integrates heat sources and heat sinks at various temperature levels and is flexible in terms of network expansion. Furthermore, we used Modelica simulations to compare the new single-pipe reservoir network to a basecase double-pipe network, taking yearly demand profiles of different building types for heating and cooling. The electric energy consumed by the heat pumps and circulations pumps differs between the reservoir and base case networks by less than 1%. However, if the reservoir network is operated with constant instead of variable mass flow rate, the total electrical consumption can increase by 48% compared to the base case. As with any other network topology, the design and control of such networks is crucial to achieving energy efficient operation. Investment costs for piping and trenching depend on the district layout and dimensioning of the network. If a ring layout is applied in a district, the reservoir network with its single-pipe configuration is more economical than other topologies. For a linear layout, the piping costs are slightly higher for the reservoir network than for the base case because of larger pipe diameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Influence of cooling rate on the development of multiple generations of {gamma}' precipitates in a commercial nickel base superalloy

The compositional and microstructural evolution of different generations of {gamma}' precipitates during the continuous cooling of a commercial nickel base superalloy, Rene88DT, has been characterized by three dimensional atom probe tomography coupled with energy-filtered transmission electron microscopy studies. After solutionizing in the single {gamma} phase field, continuous cooling at a very high rate results in a monomodal size distribution of {gamma}' precipitates with a high nucleation density and non-equilibrium compositions. In contrast, a relatively slower cooling rate ({approx} 24 deg. C/min) results in a multi-modal size distribution of {gamma}' precipitates with the larger first generation primary precipitates exhibiting close to equilibrium composition, along with the smaller scale secondary {gamma}' precipitates, exhibiting non-equilibrium composition (excess of Co and Cr, depleted in Al and Ti). The composition of the {gamma} matrix near these precipitates also exhibits similar trends with the composition being closer to equilibrium near the primary precipitates as compared to the secondary precipitates. - Highlights: {yields} Effect of cooling rate on the precipitation of {gamma}' particles in commercial nickel base superalloy. {yields} Couples EFTEM and 3DAP studies to determine the composition and morphology of {gamma}' precipitates. {yields} Determination of near and far field compositional variations within the gamma matrix leading to subsequent precipitation.

36 MATERIALS SCIENCE↗

Effect of cooling rate on the microstructure and microhardness of the CuZrAgAl alloy

The effect of cooling rate on the microstructure and microhardness of the Cu{sub 40}Zr{sub 44}Ag{sub 8}Al{sub 8} (at.%) alloy has been studied. The crystalline phases were characterized by X-ray diffraction, optical microscopy and scanning electron microscopy with energy dispersive X-ray spectroscopy, and identified as AlCu{sub 2}Zr, Cu{sub 10}Zr{sub 7} and CuZr{sub 2}. The solidification sequence was established as following: the Cu{sub 10}Zr{sub 7} phase forms first in the periphery of the rod, then following with AlCu{sub 2}Zr phase in the rod center and finally CuZr{sub 2} crystals in Cu-depleted areas. The effect of crystals on the mechanical properties of the Cu{sub 40}Zr{sub 44}Ag{sub 8}Al{sub 8} alloy was also estimated through the microhardness. According to the value of microhardness, inhomogeneous structure of the amorphous matrix is more easily formed for the alloy in the low cooling rate (i.e., 9 mm) as compared with the alloy with fully amorphous state in the large cooling rate (i.e., 3 mm). This inhomogeneous structure was attributed to the composition change of amorphous matrix arising from the forming of crystalline phases due to the low cooling rate. - Highlights: Black-Right-Pointing-Pointer The crystalline phases in the Cu{sub 40}Zr{sub 44}Ag{sub 8}Al{sub 8} alloy were identified. Black-Right-Pointing-Pointer The solidification sequence of Cu{sub 40}Zr{sub 44}Ag{sub 8}Al{sub 8} alloy was verified. Black-Right-Pointing-Pointer The softening and hardening of alloy could be observed due to the crystallization.

36 MATERIALS SCIENCE↗

Effect of cooling rate and Mg addition on the structural evaluation of rapidly solidified Al-20wt%Cu-12wt%Fe alloy

The present work examines the effect of Mg contents and cooling rate on the morphology and mechanical properties of Al{sub 20}Cu{sub 12}Fe quasicrystalline alloy. The microstructure of the alloys was analyzed by scanning electron microscopy and the phase composition was identified by X-ray diffractometry. The melting characteristics were studied by differential thermal analysis under an Ar atmosphere. The mechanical features of the melt-spun and conventionally solidified alloys were tested by tensile-strength test and Vickers micro-hardness test. It was found that the final microstructure of the Al{sub 20}Cu{sub 12}Fe samples mainly depends on the cooling rate and Mg contents, which suggests that different cooling rates and Mg contents produce different microstructures and properties. The average grain sizes of the melt spun samples were about 100–300 nm at 35 m/s. The nanosize, dispersed, different shaped quasicrystal particles possessed a remarkable effect to the mechanical characteristics of the rapidly solidified ribbons. The microhardness values of the melt spun samples were approximately 18% higher than those of the conventionally counterparts. - Highlights: •Quasicrystal-creating materials have high potential for applications. •Different shaped nanosize quasicrystal particles were observed. •The addition of Mg has an important impact on the mechanical properties. •H{sub V} values of the MS0, MS3 and MS5 samples at 35 m/s were 8.56, 8.66 and 8.80 GPa. •The volume fraction of IQC increases with increasing cooling rates.

36 MATERIALS SCIENCE↗

Effect of cooling rates on the structure, density and micro-indentation behavior of the Fe, Co-based bulk metallic glass

The experiments demonstrate that ductility of the samples of bulk metallic glass (BMG) with the same chemical composition increased with decreasing sample size. It is shown that microhardness and density increases with decreasing the cooling rate. The fracture morphology of rods after compressive fracture were different on the cross section. Two characteristic features of the compressive fracture morphologies of metallic glasses (MGs) were observed in samples: smooth region and the vein pattern. Many parallel shear bands were observed on the deformed specimen with ϕ = 2 mm in diameter. The results provide more understanding on the relationship among the cooling rate, structure and micro-indentation behavior of the Fe-Co-based BMGs. - Highlights: •Fracture morphology and micro-indentation behavior is studied. •The smaller BMG sample exhibits the larger plasticity. •Microhardness and density increase with decreasing the cooling rate. •Formation of shear bands has been reported in deformed specimens. •Structure and mechanical properties of BMGs can be controlled by the cooling rate.

36 MATERIALS SCIENCE↗

Wave-optics modeling of the optical-transport line for passive optical stochastic cooling

Optical stochastic cooling (OSC) is expected to enable fast cooling of dense particle beams. Transition from microwave to optical frequencies enables an achievement of stochastic cooling rates which are orders of magnitude higher than ones achievable with the classical microwave based stochastic cooling systems. A subsystemcritical to the OSC scheme is the focusing optics used to image radiation from the upstream “pickup” undulator to the downstream “kicker” undulator. In this paper, we present simulation results using wave-optics calculation carried out with the Synchrotron Radiation Workshop (SRW). Our simulations are performed in support to a proof-of-principle experiment planned at the Integrable Optics Test Accelerator (IOTA) at Fermilab. The calculations provide an estimate of the energy kick received by a 100-MeV electron as it propagates in the kicker undulator and interacts with the electromagnetic pulse it radiated at an earlier time while traveling through the pickup undulator.

42 ENGINEERING↗

Status of MICE, the international Muon Ionization Cooling Experiment

An international experiment designed to demonstrate muon ionization cooling is being built at Rutherford Appleton Laboratory (RAL). The experiment consists of one cell of a Neutrino Factory cooling channel, along with upstream and downstream detectors to identify individual muons and measure their initial and final emittance to a precision of 0.1%. Magnetic design of the beamline and cooling channel are complete, and portions are under construction. This paper describes the experiment, including cooling channel hardware designs, fabrication status, and running plans.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigations on Cooling Mechanisms of Highly Charged Ions at HITRAP

The upcoming facility HITRAP (Highly Charged Ion TRAP) at GSI will enable high-precision atomic-physics investigations on heavy, highly charged ions at extremely low energies. Species up to U{sup 92+} will be produced at the GSI accelerator complex by stripping of relativistic ions and injected into the Experimental Storage Ring (ESR) where they are electron-cooled and decelerated to 4 MeV/u. After ejection out of the ESR and further deceleration in a linear decelerator bunches of 10{sup 5} ions will be injected into a Penning trap and cooled to 4 K via electron and resistive cooling. Simulations with a Particle-In-Cell (PIC) code have been carried out to study the dynamics of the ion cloud in the Cooler Trap with focus on resistive cooling in presence of space charge.

43 PARTICLE ACCELERATORS↗

The International Muon Ionization Cooling Experiment: MICE and Neutrino Factories

The Muon Ionization Cooling Experiment (MICE) is an accelerator and particle physics experiment aimed at demonstrating the technique of ionization cooling on a beam of muons. Ionization cooling is the process by which muons are sent through an absorbing material, thereby losing energy and decreasing their normalized emittance. The muons are then reaccelerated in the appropriate direction with radio frequency (RF) cavities. This produces an overall reduction in transverse emittance of the muon beam. Ionization cooling could be a key technique in the design of a high intensity Neutrino Factory.

43 PARTICLE ACCELERATORS↗

The effect of cooling rates on the apparent fragility of Zr-based bulk metallic glasses

We investigate the behavior of the kinetic fragility parameter D* as different cooling rates are applied to samples of the Zr{sub 57}Cu{sub 15.4}Ni{sub 12.6}Al{sub 10}Nb{sub 5} and Zr{sub 58.5}Cu{sub 15.6}Ni{sub 12.8}Al{sub 10.3}Nb{sub 2.8} bulk metallic glass formers. The glassy samples are heated into the supercooled liquid region using differential scanning calorimetry (DSC) and cooled back into the glassy state with sets of different cooling rates, q{sub C}. The shifts in the glass transition are measured by determining the onset glass transition temperature, T{sub g}{sup onset}, as well as the limiting fictive temperature, T{sub f}{sup '}, upon reheating with a set of heating rates, q{sub H}. We then model the data by assuming a Vogel-Fulcher-Tammann-type behavior in the structural relaxation time, {tau}, and observe an apparent increase in the kinetic fragility parameter for slower cooling rates. These results show that fragilities calculated from DSC scans, where q{sub H}=q{sub C} are in good agreement with those from equilibrium viscosity data recently obtained by three-point beam-bending.

36 MATERIALS SCIENCE↗

Simulations on Resistive Cooling of Trapped Highly-Charged Particles

The increasing demand for high accuracies in atomic physics experiments requires intense beams of heavy and highly charged ions (HCI) which must be decelerated and cooled to extremely low energies. In the upcoming HITRAP (Highly charged Ion Trap) facility at GSI, Darmstadt HCI will be trapped and resistively cooled thanks to the electronic dissipation of kinetic energy on an external impedance. The cooling mechanism becomes highly nonlinear when applied to large ensembles of particles and due to the lack of thorough theoretical and experimental investigations the understanding of the process is still very limited. Our Particle-In-Cell simulations show the feasibility of this cooling mechanism and reveal some of its characteristic features.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fuel Breeding and Core Behavior Analyses on In Core Fuel Management of Water Cooled Thorium Reactors

Thorium fuel cycle with recycled U-233 has been widely recognized having some contributions to improve the water-cooled breeder reactor program which has been shown by a feasible area of breeding and negative void reactivity which confirms that fissile of 233U contributes to better fuel breeding and effective for obtaining negative void reactivity coefficient as the main fissile material. The present study has the objective to estimate the effect of whole core configuration as well as burnup effects to the reactor core profile by adopting two dimensional model of fuel core management. About more than 40 months of cycle period has been employed for one cycle fuel irradiation of three batches fuel system for large water cooled thorium reactors. All position of fuel arrangement contributes to the total core conversion ratio which gives conversion ratio less than unity of at the BOC and it contributes to higher than unity (1.01) at the EOC after some irradiation process. Inner part and central part give the important part of breeding contribution with increasing burnup process, while criticality is reduced with increasing the irradiation time. Feasibility of breeding capability of water-cooled thorium reactors for whole core fuel arrangement has confirmed from the obtained conversion ratio which shows higher than unity. Whole core analysis on evaluating reactivity change which is caused by the change of voided condition has been employed for conservative assumption that 100% coolant and moderator are voided. It obtained always a negative void reactivity coefficient during reactor operation which shows relatively more negative void coefficient at BOC (fresh fuel composition), and it becomes less negative void coefficient with increasing the operation time. Negative value of void reactivity coefficient shows the reactor has good safety properties in relation to the reactivity profile which is the main parameter in term of criticality safety analysis. Therefore, this evaluation has confirmed that breeding condition and negative coefficient can be obtained simultaneously for water-cooled thorium reactor obtains based on the whole core fuel arrangement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiative cooling of bulk silicon by incoherent light pump

In contrast to radiative cooling by light up conversion caused exclusively by a low-entropy laser pump and employing thermally assisted fluorescence/luminescence as a power out, we demonstrate light down conversion cooling by incoherent pumps, 0.47–0.94 μm light emitting diodes, and employing thermal emission (TE) as a power out. We demonstrate ≤3.5 K bulk cooling of Si at 450 K because overall energy of multiple below bandgap TE photons exceeds the energy of a single above bandgap pump photon. We show that using large entropy TE as power out helps avoid careful tuning of an incoherent pump wavelength and cool indirect-bandgap semiconductors.

36 MATERIALS SCIENCE↗

Hydrogen cooling options for MgB{sub 2}-based superconducting systems

With the arrival of MgB{sub 2} for low-cost superconducting magnets, hydrogen cooling has become an interesting alternative to costly liquid helium. Hydrogen is generally regarded as the most efficient coolant in cryogenics and, in particular, is well suited for cooling superconducting magnets. Cooling methods need to take into account the specific quench propagation in the MgB{sub 2} magnet winding and facilitate a cryogenically reliable and safe cooling environment. The authors propose three different multi-coolant options for MRI scanners using helium or hydrogen within the same design framework. Furthermore, a design option for whole-body scanners which employs technology, components, fueling techniques and safety devices from the hydrogen automotive industry is presented, continuing the trend towards replacing helium with hydrogen as a safe and cost efficient coolant.

42 ENGINEERING↗