Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Gamma Knife Radiosurgery for the Treatment of Cystic Cerebral Metastases

Purpose: To assess the role of Gamma Knife radiosurgery (GKRS) in the treatment of nonsurgical cystic brain metastasis, and to determine predictors of response to GKRS. Methods: We reviewed a prospectively maintained database of brain metastases patients treated at our institution between 2006 and 2010. All lesions with a cystic component were identified, and volumetric analysis was done to measure percentage of cystic volume on day of treatment and consecutive follow-up MRI scans. Clinical, radiologic, and dosimetry parameters were reviewed to establish the overall response of cystic metastases to GKRS as well as identify potential predictive factors of response. Results: A total of 111 lesions in 73 patients were analyzed; 57% of lesions received prior whole-brain radiation therapy (WBRT). Lung carcinoma was the primary cancer in 51% of patients, 10% breast, 10% colorectal, 4% melanoma, and 26% other. Fifty-seven percent of the patients were recursive partitioning analysis class 1, the remainder class 2. Mean target volume was 3.3 mL (range, 0.1-23 mL). Median prescription dose was 21 Gy (range, 15-24 Gy). Local control rates were 91%, 63%, and 37% at 6, 12, and 18 months, respectively. Local control was improved in lung primary and worse in patients with prior WBRT (univariate). Only lung primary predicted local control in multivariate analysis, whereas age and tumor volume did not. Lesions with a large cystic component did not show a poorer response compared with those with a small cystic component. Conclusions: This study supports the use of GKRS in the management of nonsurgical cystic metastases, despite a traditionally perceived poorer response. Our local control rates are comparable to a matched cohort of noncystic brain metastases, and therefore the presence of a large cystic component should not deter the use of GKRS. Predictors of response included tumor subtype. Prior WBRT decreased effectiveness of SRS for local control rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MicroRNA-223 Enhances Radiation Sensitivity of U87MG Cells In Vitro and In Vivo by Targeting Ataxia Telangiectasia Mutated

Purpose: Ataxia telangiectasia mutated (ATM) protein is important in the DNA damage response because it repairs radiation-induced damage in cancers. We examined the effect of microRNA-223 (miR-223), a regulator of ATM expression, on radiation sensitivity of cancer cells. Methods and Materials: Human embryonic kidney 293 T (293T) cells were infected with pLL3.7-miR-223 plasmid to generate the pLL3.7-miR-223 and -empty virus (EV) lentivirus (miR-223 and EV). A dual luciferase assay in which the reporter contained wild-type 3′ untranslated region (UTR) of ATM was performed. U87MG cells were infected with miR-223 or EV to establish the overexpressed stable cell lines (U87-223 or U87-EV, respectively). Cells were irradiated in vitro, and dose enhancement ratios at 2 Gy (DER{sub 2}) were calculated. Hind legs of BALB/c athymic mice were injected with U87-223 or U87-EV cells; after 2 weeks, half of the tumors were irradiated. Tumor volumes were tracked for a total of 5 weeks. Results: The dual luciferase reporter assay showed a significant reduction in luciferase activity of 293T cells cotransfected with miR-223 and the ATM 3′UTR compared to that in EV control. Overexpression of miR-223 in U87MG cells showed that ATM expression was significantly downregulated in the U87-223 cells compared to that in U87-EV (ATM/β-actin mRNA 1.0 vs 1.5, P<.05). U87-223 cells were hypersensitive to radiation compared to U87-EV cells in vitro (DER{sub 2} = 1.32, P<.01). Mice injected with miR-223-expressing tumors had almost the same tumors after 3 weeks (1.5 cm{sup 3} vs 1.7 cm{sup 3}). However, irradiation significantly decreased tumor size in miR-223-expressing tumors compared to those in controls (0.033 cm{sup 3} vs 0.829 cm{sup 3}). Conclusions: miR-223 overexpression downregulates ATM expression and sensitizes U87 cells to radiation in vitro and in vivo. MicroRNA-223 may be a novel cancer-targeting therapy, although its cancer- and patient-specific roles are currently undefined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of stacking faults breaking the [110]/[110] symmetry in ferromagnetic semiconductors (Ga,Mn)As and (Ga,Mn)(As,P)

We report on high-resolution x-ray diffraction measurements of (Ga,Mn)As and (Ga,Mn)(As,P) epilayers. We observe a structural anisotropy in the form of stacking faults that are present in the (111) and (111) planes and absent in the (111) and (111) planes. They occupy 10{sup -2}%-10{sup -1}% of the ferromagnetic epilayer volume while no stacking faults are detected in the controlled, undoped GaAs epilayer. Full-potential density functional calculations provide additional evidence that the formation of the stacking faults is promoted by Mn attracted to these structural defects. The enhanced Mn density along the common [110] direction of the stacking fault planes produces a symmetry-breaking mechanism of a strength and sense that can account for the uniaxial [110]/[110] magnetocrystalline anisotropy of these ferromagnetic semiconductors.

36 MATERIALS SCIENCE↗

Space astronomical telescopes and instruments; Proceedings of the Meeting, Orlando, FL, Apr. 1-4, 1991

The present volume on space astronomical telescopes and instruments discusses lessons from the HST, telescopes on the moon, future space missions, and mirror fabrication and active control. Attention is given to the in-flight performance of the Goddard high-resolution spectrograph of the HST, the initial performance of the high-speed photometer, results from HST fine-guidance sensors, and reconstruction of the HST mirror figure from out-of-focus stellar images. Topics addressed include system concepts for a large UV/optical/IR telescope on the moon, optical design considerations for next-generation space and lunar telescopes, the implications of lunar dust for astronomical observatories, and lunar liquid-mirror telescopes. Also discussed are space design considerations for the Space Infrared Telescope Facility, the Hubble extrasolar planet interferometer, Si:Ga focal-plane arrays for satellite and ground-based telescopes, microchannel-plate detectors for space-based astronomy, and a method for making ultralight primary mirrors.

Bely, Pierre Y.↗

Ion Exchange and Solvent Extraction: Supramolecular Aspects of Solvent Exchange Volume 21

Preface The theme of supramolecular chemistry (SC), entailing the organization of multiple species through noncovalent interactions, has permeated virtually all aspects of chemical endeavor over the past several decades. Given that the observed behavior of discrete molecular species depends upon their weak interactions with one another and with matrix components, one would have to conclude that SC must indeed form part of the fabric of chemistry itself. A vast literature now serves to categorize SC phenomena within a body of consistent terminology. The word supramolecular itself appears in the titles of dozens of books, several journals, and a dedicated encyclopedia. Not surprisingly, the theme of SC also permeates the field of solvent extraction (SX), inspiring the framework for this volume of Ion Exchange and Solvent Extraction. It is attempted in the six chapters of this volume to identify both how supramolecular behavior occurs and is studied in the context of SX and how SC is influencing the current direction of SX. Researchers and practitioners have long dealt with supramolecular interactions in SX. Indeed, the use of polar extractant molecules in nonpolar media virtually assures that aggregative interactions will dominate the solution behavior of SX. Analytical chemists working in the 1930s to the 1950s with simple mono- and bidentate chelating ligands as extractants noted that extraction of metal ions obeyed complicated mass-action equilibria involving complex stoichiometries. As chemists and engineers developed processes for nuclear and hydrometallurgical applications in the 1950s and 1960s, the preference for aliphatic diluents only enhanced the complexity and supramolecular nature of extraction chemistry. Use of physical techniques such as light scattering and vapor-pressure measurements together with various spectroscopic methods revealed organic-phase aggregates from well-defined dimers to small aggregates containing a few extractant molecules to large inverse micelles swollen with water molecules. Extraction systems involving long-chain cations such as alkylammonium species or long-chain anions such as sulfonates or carboxylates proved especially prone to extensive aggregate formation. The related phenomenon of third-phase formation in SX systems, long misunderstood, is now yielding to spectroscopic and scattering techniques showing extensive long-range organization. Over the last 50 years, tools for studying the structure and thermodynamics of aggregation have grown increasingly sophisticated, leading to a rich and detailed understanding of what we can now recognize as SC phenomena in SX. In the 1970s and 1980s, the rapid growth of SC elicited a paradigm shift in SX. The influence of SC principles had two major effects on the course of SX research. First, it provided a framework for understanding the supramolecular behavior that was already well appreciated in the field of SX, though earlier without the SC terminology. Second, it provided the conceptual tools to control supramolecular behavior in SX, direct it for intended functionality, and to simplify it. Extraction by designed reagents has been steadily progressing ever since, with commercial applications emerging to successfully validate this approach. With the discovery of crown ethers in the late 1960s, the advancement of extractant design has fruitfully employed the concept of inclusion. While considerable initial progress occurred with such molecules, especially because of their affinity and selectivity for alkali and alkaline earth metals, other molecular platforms such as calixarenes have proven more versatile. Multidentate receptors for partial to full inclusion of cations, anions, ion pairs, as well as neutral species, have now become commonplace for selective extraction. This volume of Ion Exchange and Solvent Extraction examines how the principles of SC are being employed both in advancing the design of new highly selective SX systems and in understanding aggregation phenomena in SX systems. Chapter 1 discusses the nature and definition of SC and how it is used generally in design of novel SX reagents. Major approaches using SC principles are outlined and illustrated. Chapter 2 expands upon the theme of ion-pair recognition and introduces outer-sphere recognition of metal complexes, a novel idea with the potential for structural control of solvation, casting a new light on solvent modifiers. Chapter 3 reviews the large literature of calixarenes as extraction reagents for metal ions, where the synthetic versatility of this family of compounds has produced vast possibilities for inclusion and selective separations. Chapter 4 extends such chemistry to extraction of biomolecules, where the potential for selective separations is only beginning to be explored through site recognition in macromolecules. In Chapter 5, a detailed examination of the liquid-liquid interface as an expression of supramolecular phenomena i...

Gloe, Karsten↗

NASA Tech Briefs, August 2013

Topics covered include: Radial Internal Material Handling System (RIMS) for Circular Habitat Volumes; Conical Seat Shut-Off Valve; Impact-Actuated Digging Tool for Lunar Excavation; Flexible Mechanical Conveyors for Regolith Extraction and Transport; Remote Memory Access Protocol Target Node Intellectual Property; Soft Decision Analyzer; Distributed Prognostics and Health Management with a Wireless Network Architecture; Minimal Power Latch for Single-Slope ADCs; Bismuth Passivation Technique for High-Resolution X-Ray Detectors; High-Strength, Super-elastic Compounds; Cu-Cr-Nb-Zr Alloy for Rocket Engines and Other High-Heat- Flux Applications; Microgravity Storage Vessels and Conveying-Line Feeders for Cohesive Regolith; CRUQS: A Miniature Fine Sun Sensor for Nanosatellites; On-Chip Microfluidic Components for In Situ Analysis, Separation, and Detection of Amino Acids; Spectroscopic Determination of Trace Contaminants in High-Purity Oxygen; Method of Separating Oxygen From Spacecraft Cabin Air to Enable Extravehicular Activities; Atomic Force Microscope Mediated Chromatography; Sample Analysis at Mars Instrument Simulator; Access Control of Web- and Java-Based Applications; Tool for Automated Retrieval of Generic Event Tracks (TARGET); Bilayer Protograph Codes for Half-Duplex Relay Channels; Influence of Computational Drop Representation in LES of a Droplet-Laden Mixing Layer.

Source record↗

Toward a lean analysis for waste to support the decommissioning operation - 15321

All over the world, several nuclear facilities have been shut down few years ago and are now under dismantling or will be dismantled in the future. - Dismantling project takes place according to three major phases: - Study and definition of the dismantling scenario - Dismantling site operations - Decommissioning and final state characterization. Each step is lead in agreement with safety, security and waste management. This requires analytical tools appropriate to the radiological environment and aims. In the field of security, fissile products, explosives... will be researched and quantified while occupational safety requires quantification of radiological, carcinogenic, mutagenic and reprotoxic elements such as As, Se, Cr(IV)... or even asbestos in order to follow more and more strengthened rules. For waste management, radiological and chemical quantification are necessary but must be completed by determining physical and chemical properties such as reactivity, stability or dissolution of the waste... Required level of knowledge, analytical deadline, uncertainties, limits of detection and matrix varieties depend on the decommissioning phase. Setting up a dismantling scenario requires the most possible accurate knowledge of the initial source term present in the facility, in order to establish waste management flow-sheets, define dismantling intervention modes, and prepare the associated safety demonstrations. As history is often not sufficient, in-situ investigations and off-site laboratories are necessary to assign an initial waste and radiological inventory and propose some strategy operations. When a first scenario is chosen, more detailed samplings and analyses are required to fully prepare estimates of waste volumes and categories, and define and validate the waste recovery system that would be used during the dismantling operation. As the definition of the dismantling plan takes shape, data must be more and more accurate and reliable in order to define the waste outlet. The scaling factors for the waste must be defined in order to assure the refunding of the waste. This includes complete characterizations of various matrixes, with high precision, low detection limit in a limited time of few months, as sketchy data could lead to fix inappropriate plan Once site operations begin, it is necessary to control the safety operational conditions and waste production. Measurements requirement is under the safety threshold. Matrixes are often limited to filter. The most important factor is deadline, because operations delay is costly. Finally at the end of dismantling operations, analyses must be performed to demonstrate the successful clean-up of the work site. Analytical methods with low detection limit are required. Thus, characterization appears as a graded and iterative process and is a key issue for decommissioning and dismantling operations in term of efficiency and cost. In order to face this huge analytical demand, a strategy for sampling and characterization must be developed regarding the real needs. On site measurements are usually performed with existing hand-held instruments. A basic first level of knowledge is obtained without delay, feeding the dismantling scenario. On these bases, a sampling strategy permits to select some representative specimens to be more precise, and accurate analysis is performed on off-site laboratories introducing an additional difficulty: the sampling on the site and sub-sampling in the laboratory itself. Whatever the level of sampling, aliquots are small considering the dimension of the dismantling area. This step is crucial. Sampling strategy must be optimized according to objectives (scaling factors measurement, waste level). But in the particular case of high radioactive level waste, due to security manipulation constraints, the number and mass of samples collected are limited. At the opposite for low level waste, large number of samples is collected meaning that large analytical method capacity is necessary. Optimization of the analytical plan is critical. The analytical strategy (including control of sub-sampling, analysis sequence according to analytical capability and performances, especially for pure beta emitters) developed for real case will be detailed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statistical Analysis in Support of Fuel Temperature Control in the Advanced Gas Reactor Experiments

There are four completed tests among a series of Advanced Gas Reactor (AGR) irradiation experiments that are being conducted within the Advanced Reactor Technologies (ART) Fuel Development and Qualification Program. The main objectives of the fuel experimental campaigns are to provide the necessary data on fuel performance to support fuel process development, qualify a fuel design and fabrication process for normal operation and hypothetical accident conditions, and support development and validation of fuel performance and fission product transport models and codes. Since this tri-structural isotropic fuel is qualified to be used in high temperature gas-cooled reactors (HTGRs), it is essential that the testing conditions of fuel irradiations are designed to mimic those in the conceptual gas reactors. As a result, temperatures of the AGR test fuel have to be maintained within a specified range that is typical of the HTGRs. In each AGR capsule, the test fuel temperature is controlled independently using a variable fraction neon and helium gas mixture that fills the gap volume for each capsule. The temperature as measured by a thermocouple (TC) terminated in the graphite holder (which houses fuel compacts) is used as a feedback for the gas flow controllers. Direct temperature measurement for fuel compacts is not possible because contact between a TC head and fuel particle could lead to undesirable failures. Therefore, an ABAQUS-based finite element thermal model was created to predict the daily average fuel temperatures during the entire irradiation period. It is well-known that extended exposure to neutron irradiation and high temperatures leads to changes in geometries of fuel compacts and graphite holder, which results in changes of the gas gap, leading to a change in the relationship between TC and fuel temperatures. In addition, TCs are expected to drift and sometimes fail under irradiation conditions. These facts make maintaining test fuel temperature within a specified range challenging. This paper describes how the regression analysis methods are used in conjunction with calculated fuel temperatures from early irradiation periods (when the irradiation effect is relatively small) to effectively control fuel temperature for the remaining irradiation (when the irradiation effect became profound). This is particularly important in the event when all TCs in a capsule fail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computed Tomography Radiomics Predicts HPV Status and Local Tumor Control After Definitive Radiochemotherapy in Head and Neck Squamous Cell Carcinoma

Purpose: This study aimed to predict local tumor control (LC) after radiochemotherapy of head and neck squamous cell carcinoma (HNSCC) and human papillomavirus (HPV) status using computed tomography (CT) radiomics. Methods and Materials: HNSCC patients treated with definitive radiochemotherapy were included in the retrospective study approved by the local ethical commission (93 and 56 patients in the training and validation cohorts, respectively). Three hundred seventeen CT radiomic features, including those based on shape, intensity, texture, and wavelet transform, were calculated in the primary tumor region. Cox and logistic regression models were built to predict LC and HPV status, respectively. The best-performing features in the univariable analysis were included in the multivariable analysis after the exclusion of redundant features. The quality of the models was assessed using the concordance index (CI) for modeling of LC and receiver operating characteristics area under the curve (AUC) for HPV status prediction. The radiomics LC model was compared to a model incorporating clinical parameters (tumor stage, volume, and HPV status) and a mixed model. Results: A radiomic signature comprising 3 features was significantly associated with LC (CI{sub training} = 0.75 and CI{sub validation} = 0.78), showing that tumors with a more heterogeneous CT density distribution are at risk for decreased LC. The addition of clinical parameters to the radiomics model slightly improved the model in the training cohort but not in the validation cohort. Another radiomic signature showed good performance in HPV status prediction (AUC{sub training} = 0.85 and AUC{sub validation} = 0.78) and indicated that HPV-positive tumors have a more homogenous CT density distribution. Conclusions: Heterogeneity of HNSCC tumor density, quantified by CT radiomics, is associated with LC after radiochemotherapy and HPV status.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of picogram- and femtogram-input DNA libraries for microscale metagenomics

High-throughput sequencing libraries are typically limited by the requirement for nanograms to micrograms of input DNA. This bottleneck impedes the microscale analysis of ecosystems and the exploration of low biomass samples. Current methods for amplifying environmental DNA to bypass this bottleneck introduce considerable bias into metagenomic profiles. For this study, we describe and validate a simple modification of the Illumina Nextera XT DNA library preparation kit which allows creation of shotgun libraries from sub-nanogram amounts of input DNA. Community composition was reproducible down to 100 fg of input DNA based on analysis of a mock community comprising 54 phylogenetically diverse Bacteria and Archaea. The main technical issues with the low input libraries were a greater potential for contamination, limited DNA complexity which has a direct effect on assembly and binning, and an associated higher percentage of read duplicates. We recommend a lower limit of 1 pg (~100–1,000 microbial cells) to ensure community composition fidelity, and the inclusion of negative controls to identify reagent-specific contaminants. Applying the approach to marine surface water, pronounced differences were observed between bacterial community profiles of microliter volume samples, which we attribute to biological variation. This result is consistent with expected microscale patchiness in marine communities. We thus envision that our benchmarked, slightly modified low input DNA protocol will be beneficial for microscale and low biomass metagenomics.

100 fg↗

Universal limiter for transient interpolation modeling of the advective transport equations: The ULTIMATE conservative difference scheme

A fresh approach is taken to the embarrassingly difficult problem of adequately modeling simple pure advection. An explicit conservative control-volume formation makes use of a universal limiter for transient interpolation modeling of the advective transport equations. This ULTIMATE conservative difference scheme is applied to unsteady, one-dimensional scalar pure advection at constant velocity, using three critical test profiles: an isolated sine-squared wave, a discontinuous step, and a semi-ellipse. The goal, of course, is to devise a single robust scheme which achieves sharp monotonic resolution of the step without corrupting the other profiles. The semi-ellipse is particularly challenging because of its combination of sudden and gradual changes in gradient. The ULTIMATE strategy can be applied to explicit conservation schemes of any order of accuracy. Second-order schemes are unsatisfactory, showing steepening and clipping typical of currently popular so-called high resolution shock-capturing of TVD schemes. The ULTIMATE third-order upwind scheme is highly satisfactory for most flows of practical importance. Higher order methods give predictably better step resolution, although even-order schemes generate a (monotonic) waviness in the difficult semi-ellipse simulation. Little is to be gained above ULTIMATE fifth-order upwinding which gives results close to the ultimate for which one might hope.

Leonard, B. P.↗

Statistical Analysis in Support of Control Fuel Temperature for the Advanced Gas Reactor Experiments

There are four completed tests among a series of Advanced Gas Reactor (AGR) irradiation experiments that are being conducted within the Advanced Reactor Technologies (ART) Fuel Development and Qualification Program. The main objectives of the fuel experimental campaigns are to provide the necessary data on fuel performance to support fuel process development, qualify a fuel design and fabrication process for normal operation and hypothetical accident conditions, and support development and validation of fuel performance and fission product transport models and codes.1 Since this tristructural isotropic fuel is qualified to be used in high temperature gas-cooled reactors (HTGRs), it is essential that the testing conditions of fuel irradiations are designed to mimic those in the conceptual gas reactors. As a result, temperatures of the AGR test fuel have to be maintained within a specified range that is typical of the HTGRs. In each AGR capsule, the test fuel temperature is controlled independently using a variable fraction neon and helium gas mixture that fills the gap volume for each capsule. The temperature as measured by a thermocouple (TC) terminated in the graphite holder (which houses fuel compacts) is used as a feedback for the gas flow controllers. Direct temperature measurement for fuel compacts is not possible because contact between a TC head and fuel particle could lead to undesirable failures. Therefore, an ABAQUS based finite element thermal model was created to predict the daily average fuel temperatures during the entire irradiation period.2,3 It is well-known that extended exposure to neutron irradiation and high temperatures leads to changes in geometries of fuel compacts and graphite holder, which result in changes of the gas gap leading to a change in the relationship between TC and fuel temperatures. In addition, TCs are also expected to drift and sometimes fail under irradiation conditions. These facts make maintaining test fuel temperature within a specified range challenging. This paper describes how the regression analysis methods are used in conjunction of calculated fuel temperatures from early irradiation periods (when irradiation effect is relatively small) to effectively control fuel temperature for the remaining irradiation, when irradiation effect became profound. This is particularly important in the event of all TCs in a capsule fail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mitigate Stress Corrosion Cracking (SCC) in High-strength Al Castings (CRADA 508)

Development of high strength, corrosion resistant, aluminum alloys is important to a number of industries, including automotive, aerospace, power, etc. Understanding how processing methods such as casting, chemistry, additives and recycle content affect an alloy’s microstructure and performance in real world environments is crucial to their implementation. One major concern is how the repeated exposure to saline solutions can be detrimental to the structural integrity of aluminum alloy components. This study was undertaken as a collaboration between Eck Industries and PNNL to investigate the stress corrosion cracking (SCC) and corrosion behavior of aluminum alloys. This work examines the SCC response of three different materials set. First is cast A206 Al alloy produced by three different casting techniques (i.e., permanent mold, and sand casting with and without chill) and with or without nano forming additives as potential grain refiners. The second materials set comprises Al alloy tubes extruded by PNNL’s ShAPE process and produced using raw material with three different ratios of twitch and pre-consumer Al 6061 scrap. Finally, the third materials set comprises two Al-Si-Mg-Fe alloys with controlled Si% and Fe% to mimic recycle grade Al alloys. The corrosion behavior of these materials was characterized using SCC testing and scanning electrochemical cell microscopy (SECCM) technique; mechanical behavior was characterized using tensile testing, and microstructure was characterized using optical and electron microscopy techniques. Of the A206 Al alloys, the samples with nano forming additives performed poorly compared to those without. The best SCC performance (i.e. least degradation in mechanical properties) was demonstrated by A206 alloy sand cast with chill while the permanent mold sample showed the worst SCC performance. The SECCM was performed on A206 alloy sand cast with chill to understand the effect of microstructure and determine the location-dependent corrosion properties on grain boundaries (GB) and inside grains (IG) on the sample. The corrosion potential and current measured on GB and IG at various points on the sample established that the GB locations are more cathodic and corrosive than the IG locations. Further work needs to be conducted to investigate the mechanisms behind the observed dependence of SCC on casting technique and nano forming additives. Among the ShAPE extruded tubes, SECCM data suggests the decreasing order of tendency to corrode as follows: 100% twitch > 75% twitch > 50% twitch. Finally, both variants of the Al-Si-Mg-Fe alloys showed a large volume fraction of Fe- and Si-containing intermetallics and additional work is needed to discern differences in their respective corrosion responses. In summary, correlating local electrochemical behavior (e.g. via SECCM) with micro/nanostructure, in conjunction with bulk mechanical behavior, can help identify the right fabrication method and alloy chemistry to minimize SCC issues in Al alloys.

36 MATERIALS SCIENCE↗

A discrete dislocation dynamics study of precipitate bypass mechanisms in nickel-based superalloys

Order strengthening in nickel-based superalloys is associated with the extra stress required for dislocations to bypass the $\gamma'$ precipitates distributed in the $\gamma$ matrix. Depending on the operating conditions and microstructure, a rich variety of bypass mechanism has been identified, with various shearing and Orowan looping processes gradually giving way to climb bypass as the operating conditions change from the low/intermediate temperatures and high stress regime, to the high temperature and low stress regime. When anti phase boundary (APB) shearing and Orowan looping mechanisms operate, the classical picture is that, at for a given volume fraction, the bypass mechanism changes from shearing to looping with increased particle size and within a broad coexistence size window. Another possibility, which is supported by indirect experimental evidence, is that a third “hybrid” transition mechanism may operate. Here, in this paper we use discrete dislocation dynamics (DDD) simulations to study dislocation bypass mechanisms in Ni-based superalloys. We develop a new method to compute generalized stacking fault forces in DDD simulations, based on a concept borrowed from complex analysis and known as the winding number of a closed curve about a point. We use this method to study the mechanisms of bypass of a square lattice of spherical $\gamma'$ precipitates by $a/2\langle110\rangle$ {111} edge dislocations, as a function of the precipitates volume fraction and size. We show that not only the hybrid mechanism is possible, but also that it operates as the transition mechanism between the shearing and looping regimes over a wide range of precipitates volume fraction and radii. Based on our simulation results, we propose a simple model for the strength of this mechanism. We also consider the effects of a $\gamma$/$\gamma'$ lattice misfit on the bypass mechanisms, which we approximate by an additional precipitate stress computed according to Eshelby’s inclusion theory. We show that in the shearing and hybrid looping-shearing regimes, a lattice misfit generally results in an increased bypass stress. For sufficiently high lattice misfit, the critical bypass configuration in attractive dislocation-precipitates interactions changes dramatically, and the bypass stress is controlled by the pinning of the trailing dislocation on the exit side of the precipitates, similar to what has been reported in the high-temperature creep literature.

36 MATERIALS SCIENCE↗

MO-E-BRD-00: Breast Brachytherapy: The Phoenix of Radiation Therapy

Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.

60 APPLIED LIFE SCIENCES↗

MO-E-BRD-01: Is Non-Invasive Image-Guided Breast Brachytherapy Good?

Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.

60 APPLIED LIFE SCIENCES↗

MO-E-BRD-02: Accelerated Partial Breast Irradiation in Brachytherapy: Is Shorter Better?

Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.

60 APPLIED LIFE SCIENCES↗

MO-E-BRD-03: Intra-Operative Breast Brachytherapy: Is One Stop Shopping Best? [ Non-invasive Image-Guided Breast Brachytherapy ]

Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.

60 APPLIED LIFE SCIENCES↗