Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control simulation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

Redox Control for Processing of High-Bi HLW (VSL-18R4400-1, Rev. 0)

This report provides results from tests designed to determine the redox conditions associated with bismuth reduction and the potential for molten bismuth metal formation in a high-Bi HLW glass melt, its role in Inconel metal corrosion, and to identify feed reductant and oxidant contents to avoid issues during melter feed processing. This was accomplished through crucible scale tests and with DM10 melter system tests using simulated high bismuth HLW and a glass composition that performed well during crucible scale and DM100 melter testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of impact toughness scatter in simulated coarse-grained HAZ of E550 grade offshore engineering steel from the aspect of crystallographic structure

Highlights: • Crystallographic structure evolution in CGHAZ caused by variation of prior austenite grain size was analyzed quantitatively. • Variant selection rules changed from CP (close-packed plane) to Bain grouping with decreasing of prior austenite grain size. • A possible correlation between impact toughness scatter and crystallographic structure was established. - Abstract: This study aims at providing a new insights into the impact toughness scatter from the aspect of crystallographic structure. It demonstrated that the large impact toughness scatter associated much to the microstructure diversity. The crystallographic structure with evident scatter will display obvious discrepancy. In this work, three groups of samples simulated coarse-grained heat affected zone (CGHAZ) of an offshore engineering steel were obtained at different cooling rates. The Charpy test results showed that the toughness decreases dramatically with the decrease of cooling rate. However, the largest scatter in impact toughness occurred in the sample with medium cooling rate (15 °C/s), which was attributed to the heterogeneity in crystallographic structures. The visualization of crystallographic features showed that the prior austenite grain size has a significant effect on bainitic variant selection, which governed the effective grain size and crack propagation mechanism. CP (close-packed plane) grouping of variants is more likely to take place in large austenite grain, indicating that the size of CP region is larger than Bain zone, and the crack is short and flexural. On the contrary, in smaller austenite grain, Bain grouping of variants that always forms low angle grain boundary and favors crack propagation dominates the transformation, and it will promote the crack to propagate through the entire Bain zone and then yield large long crack. However, these two cases can co-exist in the same sample at medium cooling rate, indicating that the cleavage fracture is controlled by the effective grain size (Bain-zone size) and the scatter in impact toughness is associated much to the proportion and relative location between fine and coarse Bain zones.

36 MATERIALS SCIENCE↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of porosity on corrosion resistance of Mg alloy foam produced by powder metallurgy technology

Magnesium alloy foams have the potential to serve as structural material for regular light-weight applications as well as for biodegradable scaffold implants. However, their main disadvantage relates to the high reactivity of magnesium and consequently their natural tendency to corrode in regular service conditions and in physiological environments. The present study aims at evaluating the effect of porosity on the corrosion resistance of MRI 201S magnesium alloy foams in 0.9% NaCl solution and in phosphate buffer saline solution as a simulated physiological electrolyte. The magnesium foams were produced by powder metallurgy technology using space-holding particles to control the porosity content. Machined chips were used as raw material for the production of Mg alloy powder by milling process. The microstructure of the foams was examined using optical and scanning electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy analysis. The corrosion behavior was evaluated by immersion test and potentiodynamic polarization analysis. The results obtained clearly demonstrate that the porosity has a significant effect on the corrosion resistance of the tested foams. Foams with 14–19% porosity have a corrosion rate of 4–10 mcd and 7–15 mcd in NaCl and phosphate buffer saline solution, respectively, compared to only 0.10 mcd for the same alloy in as cast conditions. This increased corrosion degradation of the Mg foams by more than one order of magnitude compared to the cast alloy may limit their potential application in regular and physiological environments. - Highlights: • Porosity has a detrimental effect on corrosion resistance of MRI 201S Mg foams. • 14–19% porosity increases the corrosion rate by more than one order of magnitude. • Accelerated corrosion limits the use of foams in regular/physiological environments.

36 MATERIALS SCIENCE↗

Voltage Violation Prediction in Unobservable Distribution Systems

Recently, distributed energy resources (DERs) such as photovoltaic (PV) systems have garnered significant attention due to their economic and environmental benefits. However, DERs can also pose new technical challenges to distribution system operation including under/over voltage issues. In this regard, voltage violation prediction (VVP) becomes an essential component of system operation as it enables proactive control strategies. Unfortunately, classical voltage monitoring techniques assume full availability of state measurements across all nodes in the system. In real-world scenarios, distribution systems are limited with few measurement devices, rendering the system unobservable. Therefore, this paper proposes a new Bayesian matrix completion (BMC) based VVP technique that accurately predicts the probability of nodal voltage violations in unobservable (and unbalanced) distribution systems. The proposed approach is tested via simulations on the IEEE 37 test system. Results show that the proposed method offers over 90% violation prediction accuracy with as low as 50% fraction of available data.

Abujubbeh, Mohammad↗

Laboratory tests of laser control of electron beams for future colliders

Laser-driven Compton backscattering (CBS) has been proposed as method for controlling the intensity of colliding bunches in the FCC-ee so as to avoid the flip-flop instability caused by intensity asymmetry in colliding bunches. Laser-based collimation has also been proposed as an indestructible collimator for high-intensity electron beams. We have initiated a laboratory-based test program of these concepts with the E344 experiment at FACET-II. In this paper, we describe simulations of laser–beam interactions at FACET-II and the relevant scaling for FCC-ee. We also describe the experimental setup and diagnostics that will be used to make the measurements at FACET-II.

accelerator physics↗

Feedback, physics, and forecasts: The emerging paradigm of machine learning-driven battery research

Machine learning (ML) is reshaping how we understand, predict, and optimize electrochemical systems. In batteries, ML accelerates discovery across chemistry, design, and operation by transforming massive experimental and simulated datasets into predictive, interpretable models. This review consolidates a decade of progress in ML-driven battery innovation, from early-cycle feature extraction to operando image analysis and physics-informed modeling. We categorize approaches by data domain and physical fidelity, emphasizing interpretable ML for diagnostics, reinforcement learning for control, and multi-objective optimization for lifetime extension strategies. Additionally, we demonstrate how integrated models accelerate discovery, reduce testing time, and guide sustainable design. Economic analyses furthermore illustrate how these advances can lower cost per cycle and improve circularity. Together, these developments chart a path toward self-optimizing, sustainable battery technologies.

artificial intelligence↗

Evaluation of Variable Refrigerant Flow Systems Performance and the Enhanced Control Algorithm on Oak Ridge National Laboratory's Flexible Research Platform

A research project “Evaluation of Variable Refrigerant Flow (VRF) Systems Performance and the Enhanced Control Algorithm on Oak Ridge National Laboratory’s (ORNL’s) Flexible Research Platform” was performed to (1) install and validate the performance of Samsung VRF systems compared with the baseline rooftop unit (RTU) variable-air-volume (VAV) system and (2) evaluate the enhanced control algorithm for the VRF system on the two-story flexible research platform (FRP) in Oak Ridge, Tennessee. Based on the VRF system designed by Samsung and ORNL, the system was installed from February 18 through April 15, 2014. The final commissioning and system optimization were completed on June 2, 2014, and the initial test for system operation was started the following day, June 3, 2014. In addition, the enhanced control algorithm was implemented and updated on June 18. After a series of additional commissioning actions, the energy performance data from the RTU and the VRF system were monitored from July 7, 2014, through February 28, 2015. Data monitoring and analysis were performed for the cooling season and heating season separately, and the calibrated simulation model was developed and used to estimate the energy performance of the RTU and VRF systems. This final report includes discussion of the design and installation of the VRF system, the data monitoring and analysis plan, the cooling season and heating season data analysis, and the building energy modeling study

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Imaging LIDAR through Fog and Dust for Maritime Surveillance

This work supports Airborne Intelligence, Surveillance, and Reconnaissance (ISR) for tactical situational awareness in challenging environments with modified imaging LIDAR (light detection and ranging). LIDAR produces an irradiance-based scene with high, three-dimensional, spatial resolution; differentiating reflecting surfaces and surface textures not just for target detection, but also target recognition. LIDAR is generally prevented from working through all weather; as the traditional source wavelengths are scattered and/or absorbed by fog, clouds, and dust known as degraded visual environments (DVEs). This work identifies and quantifies improved optical wavelength regimes and polarization strategies that should open this otherwise denied operating window for LIDAR. We demonstrate modified imaging LIDAR's utility and ability to produce images in environments that have been challenging for traditional LIDAR (fog, dust) systems. We utilize a state-of-the-art Geiger mode avalanche photodiode (GMAPD) 32X32 detecting array for imaging with an integrated fast timing circuit ROIC per imaging detector pixel. This GMAPD is equivalent to 1024 radar receivers and produces a 3-D point cloud scene for each <lnsec laser interrogation pulse. Through this work, we have demonstrated Sandia's first imaging LIDAR system. We developed significant software to scan the GMAPD array, control data acquisition, and stitch an arbitrary number of images for greater lateral spatial resolution. We designed and built an optical system to evaluate performance, in the laboratory and in field tests, and relate to the performance at tactically important distances. Our use of this system is to study and characterize techniques that extend the range of useful imaging through fog for applications in a maritime environment. We quantify, with simulations, broad wavelength regimes and illuminating polarizations that have benefit in propagating through fog. In particular, we identify circular polarization over broad wavebands as a superior persisting signal technique in extending the useful range of active LIDAR in forward-scattering environments. Finally, we characterize the performance of our LIDAR system and confirm our theoretical predictions in the field and directly evaluate this system as a function of polarization in Sandia's medium-range Fog Tunnel Facility. This technology has potential impacts in improved ISR in maritime environments, but with further development could be revolutionary in tactical ISR by providing real-time three-dimensional full motion video (3D FMV) in DVEs.

47 OTHER INSTRUMENTATION↗

Laboratory Tests of Laser Control of Electron Beams for Future Colliders

Laser-driven Compton backscattering (CBS) has been proposed as method for controlling the intensity of colliding bunches in the FCC-ee so as to avoid the flip-flop instability caused by intensity asymmetry in colliding bunches. Laser-based collimation has also been proposed as an indestructible collimator for high-intensity electron beams. We have initiated a laboratory-based test program of these concepts with the E344 experiment at FACET-II. In this paper, we describe simulations of laser-beam interactions at FACET-II and the relevant scaling for FCC-ee. We also describe the experimental setup and diagnostics that will be used to make the measurements at FACET-II.

Accelerator Physics (physics.acc-ph)↗

Development Of A Compact Photo-injector With RF-focusing Lens For Short Pulse Electron Source Application

For development of compact ultrafast electron source system, we are currently designing a short-pulse RF-gun with RF focusing structure by means of a series of comprehensive modeling analysis processes. EM design of a 2.5 cell resonant cavity with input coupler, acceleration dynamics of photo-emitted electron bunch, EM design of RF-lens with input coupler, and phasespace analysis of focused electron bunch are systematically examined with multi-physics simulators. All the features of the 2.856 GHz cavity geometry were precisely engineered for acceleration energies ranging from 100 keV to 500 keV (safety limited) to be powered by our 5 MW S-band klystron. The klystron (Thales TH2163) and modulator system (ScandiNova K1 turnkey system) were successfully installed and tested. Performance tests of the klystron system show peak output power > 5 MW, as per operation specifications. At the quasi-relativistic energies, the electron source is capable of generating 100fC -- 1 pC electron bunch with pulse duration close to 30 fs -- 1 ps and transverse size of a few hundred microns. PIC simulations have shown that the electron bunch undergoes fast RF acceleration, rapidly reaching the desired energies, which can be controlled by tuning RF injection phase and input driving power. It has been shown that it is possible to also focus/compress the bunch longitudinally using a RF-lens, which would allow us to control the temporal resolution of the system as well. While our primary analysis has been performed on a 2.5 cell design, we are also looking into half-cell (single cavity) design that is expected to provide the same range of beam energy with a simple configuration.

Grabenhofer, Alexander↗

High Energy X-ray Applications for the Characterization of Metallic Uranium Alloys

Uranium-based metallic alloys are both candidates for fuels in high performance research and test reactors, as well as in fast spectrum reactors as nuclear transmutation fuels that can be utilized to burn long-lived minor actinides and fission products. Uranium-molybdenum (UMo) alloys are under development for the use in research and test reactors. Whereas, uranium-zirconium (U-Zr) alloys represent one of the types of fuels that are under consideration for use within the fast spectrum reactors. Both of these types of metallic fuels have been studied for over five decades in various types of reactors. Many of the previous studies had focused on performance-based aspects. However, recent advances in characterization tools and techniques, as well as short-term (low fluence) neutron irradiation facilities have contributed to a more in-depth understanding of nuclear fuel and material behavior following irradiation. This knowledge is crucial to the enhancement of current modeling and simulation techniques, particularly with respect to parameterization and validation. This paper focuses on the use of high energy x-rays to characterize metallic nuclear fuel. The specimens were composed of depleted uranium (DU) alloyed with either Zr or Mo, where DU-xZr (x = 10, 15, or 20 wt.%) and DU-yMo (y = 7 or 10 wt.%). The geometries of the specimens were 3 mm TEM disks that were ∼200 μm in thickness. The fuel alloys were initially prepared via an arc melting process. The samples were irradiated at the Advanced Test Reactor at Idaho National Laboratory (INL) using the hydraulic rabbit system. The hydraulic rabbit system allows for well-controlled, short term irradiations (less than one cycle), hence resulting in low fluences. The U-based alloys were irradiated to doses of 0.01 and 0.1 dpa. The irradiation temperature of the specimens ranged from 150 deg. C to 800 deg. C. Synchrotron characterization techniques can be used to provide insight into material microstructure ranging a multitude of spatial scales, from the atomic scale to the macroscale. High-energy x-rays at the National Synchrotron Light Source II (NSLS II) and the Advanced Photon Source (APS) have been utilized to understand the microstructural changes in these metallic alloys, specifically with respect to phase identification, phase fractions, chemical bonding, strain, and dislocation density through the use of diffraction and X-ray Absorption Spectroscopy (XAS). These experiments utilized a robot for specimen exchange during the diffraction measurements, allowing for remote handling of radioactive materials. This is an example of another recent advancement in characterization techniques that enables research with nuclear materials. Detailed results of the analyses of the microstructural changes are pending.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-580: On the Significance of Model Based Dosimetry for Breast and Head and Neck 192Ir HDR Brachytherapy

Purpose: To assess the dosimetric and radiobiological differences between TG43-based and model-based dosimetry in the treatment planning of {sup 192}Ir HDR brachytherapy for breast and head and neck cancer. Methods: Two cohorts of 57 Accelerated Partial Breast Irradiation (APBI) and 22 head and neck (H&N) patients with oral cavity carcinoma were studied. Dosimetry for the treatment plans was performed using the TG43 algorithm of the Oncentra Brachy v4.4 treatment planning system (TPS). Corresponding Monte Carlo (MC) simulations were performed using MCNP6 with input files automatically prepared by the BrachyGuide software tool from DICOM RT plan data. TG43 and MC data were compared in terms of % dose differences, Dose Volume Histograms (DVHs) and related indices of clinical interest for the Planning Target Volume (PTV) and the Organs-At-Risk (OARs). A radiobiological analysis was also performed using the Equivalent Uniform Dose (EUD), mean survival fraction (S) and Tumor Control Probability (TCP) for the PTV, and the Normal Tissue Control Probability (N TCP) and the generalized EUD (gEUD) for the OARs. Significance testing of the observed differences performed using the Wilcoxon paired sample test. Results: Differences between TG43 and MC DVH indices, associated with the increased corresponding local % dose differences observed, were statistically significant. This is mainly attributed to their consistency however, since TG43 agrees closely with MC for the majority of DVH and radiobiological parameters in both patient cohorts. Differences varied considerably among patients only for the ipsilateral lung and ribs in the APBI cohort, with a strong correlation to target location. Conclusion: While the consistency and magnitude of differences in the majority of clinically relevant DVH indices imply that no change is needed in the treatment planning practice, individualized dosimetry improves accuracy and addresses instances of inter-patient variability observed. Research co-financed by the ESF and Greek funds through the Operational Program Education and Lifelong Learning Investing in Knowledge Society of the NSRF. Research Funding Program Aristeia. Nucletron, an Elekta company (Veenendaal, The Netherlands) is gratefully acknowledged for providing Oncentra Brachy v4.4 for research purposes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Transient Mechanical Test Development for Accident Tolerant Cladding Candidates to Simulate PCMI-like Conditions

This study investigates the transient mechanical response of accident tolerant fuel (ATF) cladding candidates to provide information on potential PCMI-induced deformation and failure of candidate cladding materials. The mechanical testing is applied t to Gen-I FeCrAl and triaxially-braided SiC fiber SiC matrix composite materials under loading conditions like the PCMI during a postulated design basis reactivity insertion accident. To achieve the specific loading conditions, a modified burst test instrument with accurate mechanical pulse control has been designed and constructed. The mechanical response of FeCrAl, SiC-SiC composite tubes were compared with the pre-hydrided zirconium alloy cladding. The specimens subjected to mechanical pulses were investigated in a strain-controlled manner deformation.

Cinbiz, Nedim↗

Holistic Microstructure Control Strategies in Photopolymerization‐Induced Phase Separation of Acrylate Systems

Open porous materials, known for their large surface area and interconnected structures, are essential in various applications, including batteries, ion exchange, catalysis, filtration, and electronic waste recycling. A critical aspect of the functionality of porous membranes is the precise control of pore size and morphology. Photopolymerization-induced phase separation (photo-PIPS) offers a convenient and versatile methods for creating porous structures. However, controlling the porous morphology remains challenging due to the complex interplay between thermodynamics, polymerization kinetics, and monomer structures, which makes it difficult to establish the relationship between processing conditions and resulting morphology in photo-PIPS. Herein, a physics-based phase-field model capable of generating and characterizing the microstructures of porous materials based on both average and localized features is developed. Using the phase-field simulations as test bed, the effects of polarity, light intensity, and curing temperature, as well as the previously unexplored roles of chain transfer agents and substrates, on the morphology of the resulting porous microstructure are investigated. Experiments are performed to verify the results predicted by the simulations. This work lays out a comprehensive guide for designing PIPS-derived porous microstructures and offers practical engineering strategies for tailoring microstructure-level topology and size of pores for application-specific needs.

36 MATERIALS SCIENCE↗

Numerical Simulations in Support of a Long-Term Test of Gas Production from Hydrate Accumulations on the Alaska North Slope: Reservoir Response to Interruptions of Production (Shut-Ins)

In this work, we investigate by means of numerical simulation a planned year-long field test of depressurization-induced production from a permafrost-associated hydrate reservoir on the Alaska North Slope at the site of the recently drilled Hydrate-01 Stratigraphic Test Well. The main objective of this study is to assess quantitatively the impact of temporary interruptions (well shut-ins) on the expected fluid production performance from the B1 Sand of the stratigraphic Unit B during controlled depressurization over different time scales, as well as on other relevant aspects of the system response that have the potential to significantly affect the design of the field test. We consider eight different cases of depressurization, including (a) rapid depressurization over a 60-day period to a terminal bottomhole pressure P W of 2.8 MPa and (b) a slower depressurization rate to a final P W of 0.6 MPa at the end of the year-long production test, in addition to (c) a multi-step depressurization regime and (d) a quasi-linear continuous depressurization strategy. The results of the study indicate that shut-ins obviously reduce gas release and production during and immediately after their occurrence, but their longer-term effects are strongly dependent on the depressurization regime and on the time of observation, covering the entire range of potential outcomes. Shut-ins (a) have a universally strong negative effect when quasi-linear depressurization is involved regardless of the length of the production period, and (b) have a strong positive effect in multi-step depressurization schemes that becomes apparent earlier for large initial pressure drops, but (c) can also appear to have practically no effect for slow stepwise depressurization at the end of the year-long production test. Shut-ins lead to a rapid reformation of hydrates, even to the point of disappearance of a free gas phase in the reservoir. Rapid depressurization regimes lead to early maximum rates of hydrate dissociation and gas production, while the maximum rates occur at the end of the production test for the cases of slower depressurization. Shut-ins do not appear to have a significant impact on water production, as the cessation of production is followed by higher rates production when depressurization resumes. Similarly, (a) the fraction of produced CH 4 originating from exsolution from the water, (b) the water-to-gas ratio, and (c) the rate of replenishment of produced water by boundary inflows do not appear significantly affected by shut-ins, the effects of which seem to be temporary in the majority of the cases. The study confirmed the superiority of multi-step depressurization methods as the most effective strategies for hydrate dissociation and gas production and showed that two observation wells (located at distances of 30 and 50 m from the production well) are appropriately positioned and both able to capture the P, T, and S G behavior during the fluid production and shut-ins in any of the eight cases we investigated.

03 NATURAL GAS↗