Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Kinematic calibration of manipulators with closed loop actuated joints

A method for performing forward kinematic calibration of manipulators having one or more closed-loop-actuated joints is presented. The technique is an extension of algorithms designed for open-loop jointed manipulators. The calibration is equivalent to minimizing an objective function subject to constraints. The objective function is taken as the integral of end-effector position and orientation error. The constraints arise from the closed-loop mechanisms present in the manipulator.

Everett, Louis J.↗

Satellite Mapping of PM2.5 Episodes in the Wintertime San Joaquin Valley: A "Static" Model Using Column Water Vapor

The use of satellite Aerosol Optical Thickness (AOT) from imaging spectrometers has been successful in quantifying and mapping high PM2.5 (particulate matter mass <2.5µm diameter) episodes for pollution abatement and health studies. However, some regions have high PM2.5 but poor estimation success. The challenges in using Aerosol Optical Thickness (AOT) from imaging spectrometers to characterize PM2.5 worldwide was especially evident in the wintertime San Joaquin Valley (SJV). The SJV's attendant difficulties of high-albedo surfaces and very shallow, variable vertical mixing also occur in other significantly polluted regions around the world. We report on more accurate PM2.5 maps for the whole-winter period in the SJV, Nov 14, 2012?Dec 11, 2013. Intensive measurements by including NASA aircraft were made for several weeks in that winter, the DISCOVER-AQ California mission.We found success with a relatively simple method based on calibration and checking with surface monitors and a characterization of vertical mixing, and incorporating specific understandings of the region's climatology. We estimate PM2.5 to within ~7µgm?3 RMSE and with R values of ~0.9, based on remotely sensed MAIAC (Multi-Angle Implementation of Atmospheric Correction) observations, and that certain further work will improve that accuracy. Mapping is at 1km resolution. This allows a time sequence of mapped aerosols at 1km for cloud-free days. We describe our technique as a "static estimation". Estimation procedures like this one, not dependent on well-mapped source strengths or on transport error, should help full source-driven simulations by deconstructing processes. They also provide a rapid method to create a long-term climatology.Essential features of the technique are (a) daily calibration of the AOT to PM2.5 using available surface monitors, and (b) characterization of mixed-layer dilution using column water vapor (CWV, otherwise "precipitable water"). We noted that on multi-day timescales both water vapor and particles share near-surface sources and both fall to very low values with altitude; indeed, both are largely removed by precipitation. The existence of layers of H2O or aerosol not within the mixed layer adds complexity, but mixed-effects statistical regression captures essential proportionality of PM2.5 and the ratio variable (AOT/CWV). Accuracy is much higher than previous statistical models, and can be extended to the whole Aqua-satellite data record. The maps and time-series we show suggest a repeated pattern for large valleys like the SJV ? progressive stabilization of the mixing height after frontal passages: PM2.5 is somewhat more determined by day-by-day changes in mixing than it is by the progressive accumulation of pollutants (revealed as increasing AOT).

Chatfield, Robert B.↗

Derivation of Mathematical Expressions to Define Resonant Ejection from Square and Sinusoidal Wave Ion Traps

The use of resonant ejection for mass analysis with ion traps is increasing primarily because it markedly improves the mass range and resolution of ion traps. Unfortunately, an easy-to-use analytical expression that defines the ejection mass as a function of the trapping and excitation frequencies is missing in the literature because the secular frequency of the ions in sinusoidal ion traps is not easily determined for all stable values of qz from the Mathieu equation. However, the ion secular frequency for all stable values of qz in digital ion traps can be readily determined from Hill s equation. We have taken this expression and solved it for qz to produce an analytical expression for the ejection mass as a function of trapping and excitation frequency. We also recognized that the expression for the ion mass during resonant ejection for a square wave driven trap can be converted to an expression for a sinusoidal wave trap merely by multiplication by a factor of 4/ . These new expressions open up the possibility of rapid mass calibration for any method of resonant ejection from square or sinusoidal wave driven ion traps.

97 MATHEMATICS AND COMPUTING↗

Upscaling solute transport in naturally fractured porous media with the continuous time random walk method

Solute transport in fractured porous media is typically 'non-Fickian'; that is, it is characterized by early breakthrough and long tailing and by nonlinear growth of the Green function-centered second moment. This behavior is due to the effects of (1) multirate diffusion occurring between the highly permeable fracture network and the low-permeability rock matrix, (2) a wide range of advection rates in the fractures and, possibly, the matrix as well, and (3) a range of path lengths. As a consequence, prediction of solute transport processes at the macroscale represents a formidable challenge. Classical dual-porosity (or mobile-immobile) approaches in conjunction with an advection-dispersion equation and macroscopic dispersivity commonly fail to predict breakthrough of fractured porous media accurately. It was recently demonstrated that the continuous time random walk (CTRW) method can be used as a generalized upscaling approach. Here we extend this work and use results from high-resolution finite element-finite volume-based simulations of solute transport in an outcrop analogue of a naturally fractured reservoir to calibrate the CTRW method by extracting a distribution of retention times. This procedure allows us to predict breakthrough at other model locations accurately and to gain significant insight into the nature of the fracture-matrix interaction in naturally fractured porous reservoirs with geologically realistic fracture geometries.

54 ENVIRONMENTAL SCIENCES↗

Low-cost calibration of acoustic locators

Method uses modified commerically-available piezoelectric-torch lighter. Handheld lighter has controlled spark gap that can be easily adjusted to produce repeatable short-duration high-amplitude voltage spikes. Pulser and lighter are coupled via short axial cable, eliminating long cable run variations in cable attenuation, and problem with cable entangling with anything in its path.

Berry, R. F.↗

COBE differential microwave radiometers - Calibration techniques

The COBE spacecraft was launched November 18, 1989 UT carrying three scientific instruments into earth orbit for studies of cosmology. One of these instruments, the Differential Microwave Radiometer (DMR), is designed to measure the large-angular-scale temperature anisotropy of the cosmic microwave background radiation at three frequencies (31.5, 53, and 90 GHz). This paper presents three methods used to calibrate the DMR. First, the signal difference between beam-filling hot and cold targets observed on the ground provides a primary calibration that is transferred to space by noise sources internal to the instrument. Second, the moon is used in flight as an external calibration source. Third, the signal arising from the Doppler effect due to the earth's motion around the barycenter of the solar system is used as an external calibration source. Preliminary analysis of the external source calibration techniques confirms the accuracy of the currently more precise ground-based calibration. Assuming the noise source behavior did not change from the ground-based calibration to flight, a 0.1-0.4 percent relative and 0.7-2.5 percent absolute calibration uncertainty is derived, depending on radiometer channel.

Bennett, C. L.↗

Method for Ground-to-Space Laser Calibration System

The present invention comprises an approach for calibrating the sensitivity to polarization, optics degradation, spectral and stray light response functions of instruments on orbit. The concept is based on using an accurate ground-based laser system, Ground-to-Space Laser Calibration (GSLC), transmitting laser light to instrument on orbit during nighttime substantially clear-sky conditions. To minimize atmospheric contribution to the calibration uncertainty the calibration cycles should be performed in short time intervals, and all required measurements are designed to be relative. The calibration cycles involve ground operations with laser beam polarization and wavelength changes.

Lukashin, Constantine↗

Method for Ground-to-Satellite Laser Calibration System

The present invention comprises an approach for calibrating the sensitivity to polarization, optics degradation, spectral and stray light response functions of instruments on orbit. The concept is based on using an accurate ground-based laser system, Ground-to-Space Laser Calibration (GSLC), transmitting laser light to instrument on orbit during nighttime substantially clear-sky conditions. To minimize atmospheric contribution to the calibration uncertainty the calibration cycles should be performed in short time intervals, and all required measurements are designed to be relative. The calibration cycles involve ground operations with laser beam polarization and wavelength changes.

Lukashin, Constantine↗

Comparison of Test Methods to Determine Failure Parameters for MAT162 Calibration

MAT162, a laminated composite failure material model developed by The Material Sciences Corporation for the commercial finite element software LS-Dyna, is widely used within the aerospace industry to predict damage events under a range of dynamic conditions. The material model involves numerous inputs consisting of both physical material properties and numerical calibration parameters. Due to the large number material card inputs, often there is a lack of uniqueness to MAT162 material cards that limits the predictive capability to only the directly calibrated space. To expand this space, MAT162 requires a prudent and robust calibration process in which significant parameters are calibrated to high confidence damage events observed in experiment. Critical to this success is fully defining the material properties correctly, namely the fiber crush (SFC) and fiber shear (SFS) values, prior to calibrating the numerical parameters. In this paper, the effect of the determination of SFS and SFC on subsequent calibration steps is examined using two different experimental techniques.

Molitor, Matthew↗

Uncertainty Analysis of the CE-12 Free-Jet Probe Calibration Facility

This paper presents methods and results of a detailed measurement uncertainty analysis thf at was performed for the Free Jet Calibration Facility (CE-12) located at the NASA Glenn Research Center. Results for systematic uncertainty estimates in a number of fluid properties of the free jet flow are presented. Systematic uncertainty captures inaccuracies due to measurement process, calibration, installation effects or other similar sources which may introduce bias. MANTUS (Measurement Analysis Tool for Uncertainty in Systems) was used to quantify instrumentation uncertainty and engineering judgment was used to quantify other systematic uncertainty sources. The Monte Carlo method was used to propagate systematic uncertainties to determine the uncertainties of various calculated variables of interest.

CE-12↗

Modeling of a Modern Aircraft Through Calibration Techniques

NASA is seeking a new baseline aircraft model to assess the state-of-the-art technology for aircraft noise, emissions, and fuel/energy consumption as an update to a 2005 baseline. The process of modeling engine and airframe models as a system has historically required many iterations at NASA between the airframe and engine models. A new internal process presented in this paper contains a method that simultaneously calibrates an airframe and engine model to known data to create an aircraft system model. The work presented in this paper proposes a new framework in creating new aircraft models for future NASA research. This approach is presented as a general outline applicable to any chosen commercial aircraft. As an applied example, the B737 MAX 8 aircraft is chosen as the integrated engine and airframe model subjected to calibration. Initial results show a close match to available data but further refinement in the process is necessary for this ongoing work.

Thacker, Robert↗

Techniques for TPC Calibration: Application to Liquid Ar-TPCs

Large liquid argon TPCs are playing an increasingly important role in neutrino physics, and their calibration will be an essential component of their capability to reach the required performance and precision. Natural sources are extensively used but present limitations, since natural radioactivity from 39 Ar is of low energy, and the rate of cosmic ray muons is low when the detectors are placed deep underground. Argon gas TPCs have been calibrated with ionizing laser beams for several decades, and more recently the technique has been further developed for use in liquid TPCs. Other recent ideas include the use of external neutron generators creating pulses that propagate into the detector. This paper reviews the development of the laser and neutron methods for the calibration of argon TPCs and describes their planned implementation in the upcoming DUNE experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian Model Calibration for Extrapolative Prediction via Gibbs Posteriors

The current standard Bayesian approach to model calibration, which assigns a Gaussian process prior to the discrepancy term, often suffers from issues of unidentifiability and computational complexity and instability. When the goal is to quantify uncertainty in physical parameters for extrapolative prediction, then there is no need to perform inference on the discrepancy term. With this in mind, we introduce Gibbs posteriors as an alternative Bayesian method for model calibration, which updates the prior with a loss function connecting the data to the parameter. The target of inference is the physical parameter value which minimizes the expected loss. We propose to tune the loss scale of the Gibbs posterior to maintain nominal frequentist coverage under assumptions of the form of model discrepancy, and present a bootstrap implementation for approximating coverage rates. Our approach is highly modular, allowing an analyst to easily encode a wide variety of such assumptions. Furthermore, we provide a principled method of combining posteriors calculated from data subsets. We apply our methods to data from an experiment measuring the material properties of tantalum.

36 MATERIALS SCIENCE↗

Ultrasonic Method for Deployment Mechanism Bolt Element Preload Verification

Deployment mechanisms play a pivotal role in mission success. These mechanisms often incorporate bolt elements for which a preload within a specified range is essential for proper operation. A common practice is to torque these bolt elements to a specified value during installation. The resulting preload, however, can vary significantly with applied torque for a number of reasons. The goal of this effort was to investigate ultrasonic methods as an alternative for bolt preload verification in such deployment mechanisms. A family of non-explosive release mechanisms widely used by satellite manufacturers was chosen for the work. A willing contractor permitted measurements on a sampling of bolt elements for these release mechanisms that were installed by a technician following a standard practice. A variation of approximately 50% (+/- 25%) in the resultant preloads was observed. An alternative ultrasonic method to set the preloads was then developed and calibration data was accumulated. The method was demonstrated on bolt elements installed in a fixture instrumented with a calibrated load cell and designed to mimic production practice. The ultrasonic method yielded results within +/- 3% of the load cell reading. The contractor has since adopted the alternative method for its future production. Introduction

Johnson, Eric C.↗