Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Neutrino interaction physics and the DUNE Near Detector

DUNE is a long-baseline neutrino oscillation experiment that will take data in a wideband neutrino beam at Fermilab, starting in the latter half of the 2020s. The experiment is planning to build a very capable near detector to facilitate the high precision extraction of oscillation parameters. Part of the mission of the near detector is to acquire powerful data sets that can be used to constrain the fits used in the oscillation analyses and improve the neutrino interaction model. In this talk, the importance and the potential of a vibrant program of neutrino interaction physics using this detector is described. A few case studies that illustrate the power of the DUNE near detector for studying neutrino interaction physics are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solid Modeling of Crew Exploration Vehicle Structure Concepts for Mass Optimization

Parametric solid and surface models of the crew exploration vehicle (CEV) command module (CM) structure concepts are developed for rapid finite element analyses, structural sizing and estimation of optimal structural mass. The effects of the structural configuration and critical design parameters on the stress distribution are visualized, examined to arrive at an efficient design. The CM structural components consisted of the outer heat shield, inner pressurized crew cabin, ring bulkhead and spars. For this study only the internal cabin pressure load case is considered. Component stress, deflection, margins of safety and mass are used as design goodness criteria. The design scenario is explored by changing the component thickness parameters and materials until an acceptable design is achieved. Aluminum alloy, titanium alloy and an advanced composite material properties are considered for the stress analysis and the results are compared as a part of lessons learned and to build up a structural component sizing knowledge base for the future CEV technology support. This independent structural analysis and the design scenario based optimization process may also facilitate better CM structural definition and rapid prototyping.

Mukhopadhyay, Vivek↗

Measuring Residential Ventilation System Airflows: Part 1 – Laboratory Evaluation of Airflow Meter Devices

Building codes increasingly require tighter homes and mechanical ventilation per ASHRAE Standard 62.2. These ventilation flows must be measured so that energy is not wasted with over ventilation and occupants’ health is not compromised by under ventilation. Flow hoods are used to measure these ventilation flows, but there is currently no standard specifying the measurement procedure and measurement devices that should be used. This study evaluates the accuracy of six commercially available flow hoods under laboratory conditions configured to emulate a residential mechanical ventilation duct system. The measurements taken with the flow hoods were compared to simultaneous measurements taken by an in-line reference flow meter having a known uncertainty. Results indicate that powered flow hoods yield more accurate measurements than non-powered flow hoods, and that a majority of the flow hoods measured inlet flows more accurately than outlet flows. In several cases, there was little resemblance between the manufacturers’ stated accuracy and the accuracy we found in our laboratory measurements. It is clear that current flow hood calibration procedures may not consider field application variables such as flow asymmetry, flow angle, and flow direction. A new flow hood measurement standard that takes these ‘real world’ conditions into account should be developed to ensure that residential buildings receive the intended ventilation flows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring Residential Ventilation System Airflows: Part 1 – Laboratory Evaluation of Airflow Meter Devices

Building codes increasingly require tighter homes and mechanical ventilation per ASHRAE Standard 62.2. These ventilation flows must be measured so that energy is not wasted with over ventilation and occupants’ health is not compromised by under ventilation. Flow hoods are used to measure these ventilation flows, but there is currently no standard specifying the measurement procedure and measurement devices that should be used. This study evaluates the accuracy of six commercially available flow hoods under laboratory conditions configured to emulate a residential mechanical ventilation duct system. The measurements taken with the flow hoods were compared to simultaneous measurements taken by an in-line reference flow meter having a known uncertainty. Results indicate that powered flow hoods yield more accurate measurements than non-powered flow hoods, and that a majority of the flow hoods measured inlet flows more accurately than outlet flows. In several cases, there was little resemblance between the manufacturers’ stated accuracy and the accuracy we found in our laboratory measurements. It is clear that current flow hood calibration procedures may not consider field application variables such as flow asymmetry, flow angle, and flow direction. A new flow hood measurement standard that takes these ‘real world’ conditions into account should be developed to ensure that residential buildings receive the intended ventilation flows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tariff Setting in the District Heating Sector: Recommendations Based on International Experience

Ukraine’s district heating (DH) system is an essential resource for the country and has the potential to provide efficient, local, and renewable energy to a large share of the population. However, inefficient regulation and management have caused the sector to experience a vicious cycle of financial, operational, and technological problems. Overcoming these challenges and building a sustainable DH system requires comprehensive reforms, which could attract significant investment, improve the quality of services, and increase the efficiency of DH. One of the key elements of a comprehensive reform program should be a comprehensive reform of the tariff system. The purpose of this report is to provide analysis of European models for tariff regulation and recommendations for reforms to Ukraine’s DH tariff system. The report presents several case studies from European countries, followed by analysis of the current tariff system in Ukraine and barriers to effective regulation. Based on these findings, the report proposes actions Ukraine could take to improve the tariff regulatory system and promote a sustainable DH sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analytical Framework for Homeowner-Focused Computational Cost-Benefit Mitigation Decision Making

As a result of increasing windstorm losses in the United States over the past 50 years, a variety of residential wind hazard mitigation strategies have been recommended. Wind hazard mitigation undoubtedly reduces windstorm losses; however, little customized information is available to support the economic decision-making process for individual stakeholders, especially at the consumer level. Therefore, there is a need for decision support tools to calculate, evaluate, and present the economic benefits of mitigation over variable decision-making time horizons for unique building characteristics in specific geographical locations. This paper presents a cost-benefit computational decision-making recommendation framework that evaluates and presents the cost effectiveness of mitigation, customized based on location, years of interest, and building characteristics. The decision-making framework consists of two cores. The user-independent core and user-dependent core which consists of eight steps, divided into four subprocesses: (1) data acquisition, (2) data evaluation, (3) cost-benefit calculation, and (4) results comparison and decision making. To demonstrate the framework, a wood-framed single-family home in light suburban terrain in Golden Meadow, Louisiana, is used as a case study, considering retrofit mitigation with a $15,000 budget and a decision-making time horizon of 30 years. The case study provides six mitigation options, with cost ranging between approximately $2,000 and $15,000 and net benefit/cost ratios ranging from 2.4 to 13. Once fully implemented in a decision making information tool, the developed mitigation recommendation framework will provide valuable information that can be used by home designers, builders, owners, and other stakeholders to better understand the economic facets of wind hazard mitigation, providing critical information as part of the overall decision-making process.

Orooji, Fatemeh↗

Need for Systematic Retrofit Analysis in Multifamily Buildings

Multifamily housing offers high potential for energy savings through retrofits. A comprehensive energy audit with systematic evaluation of alternative energy measures is one of the key steps to realizing the full energy savings potential. However, this potential often remains unrealized when the selection of measures is (1) based on a one-size-fits-all approach originating from accustomed practices, (2) intended merely to meet code-compliance requirements, and/or (3) influenced by owner renter split incentive. In such cases, the benefits of comprehensive energy auditing are disregarded in view of the apparent difficulty in diagnosing multifamily buildings, evaluating alternative measures, and installing customized sets of measures. This paper highlights some of the barriers encountered in a multifamily housing retrofit project in Georgia and demonstrates the merits of systematic retrofit analysis by identifying opportunities for higher energy savings and improved comfort and indoor air quality that were missed in this project. The study uses a whole-building energy analysis conducted for a 10-unit, low-rise, multifamily building of a 110-unit apartment complex. The analysis projected a 24% energy savings from the measures installed in the building with a payback period of 10 years. Further analysis with a systematic evaluation of alternative measures showed that without compromising on the objectives of durability, livability, and appearance of the building, energy savings of up to 34% were achievable with a payback period of 7 years. The paper concludes by outlining recommendations that may benefit future retrofit projects by improving the audit process, streamlining tasks, and achieving higher energy savings.

Malhotra, Mini↗

Distributionally Robust Partially Observable Markov Decision Process with Moment-Based Ambiguity

In this paper, we consider a distributionally robust partially observable Markov decision process (DR-POMDP), where the distribution of the transition-observation probabilities is unknown at the beginning of each decision period, but their realizations can be inferred using side information at the end of each period after an action being taken. We build an ambiguity set of the joint distribution using bounded moments via conic constraints and seek an optimal policy to maximize the worst-case (minimum) reward for any distribution in the set. We show that the value function of DR-POMDP is piecewise linear convex with respect to the belief state and propose a heuristic search value iteration method for obtaining lower and upper bounds of the value function. We conduct numerical studies and demonstrate the computational performance of our approach via testing instances of a dynamic epidemic control problem. Our results show that DR-POMDP can produce more robust policies under misspecified distributions of transition-observation probabilities as compared to POMDP but has less costly solutions than robust POMDP. The DR-POMDP policies are also insensitive to varying parameter in the ambiguity set and to noise added to the true transition-observation probability values obtained at the end of each decision period.

97 MATHEMATICS AND COMPUTING↗

Advanced Gas Turbine (AGT) Technology Project

Engine testing, ceramic component fabrication and evaluation, component performance rig testing, and analytical studies comprised AGT 100 activities during the 1985 year. Ten experimental assemblies (builds) were evaluated using two engines. Accrued operating time was 120 hr of burning and 170 hr total, bringing cumulative total operating time to 395 hr, all devoid of major failures. Tests identified the generator seals as the primary working fluid leakage sources. Power transfer clutch operation was demonstrated. An alpha SiC gasifier rotor engine test resulted in blade tip failures. Recurring case vibration and shaft whip have limited gasifier shaft speeds to 84%. Ceramic components successfully engine tested now include the SiC scroll assembly, Si3N3 turbine rotor, combustor assembly, regenerator disk bulkhead, turbine vanes, piston rings, and couplings. A compressor shroud design change to reduce heat recirculation back to the inlet was executed. Ceramic components activity continues to focus on the development of state-of-the-art material strength characteristics in full-scale engine hardware. Fiber reinforced glass-ceramic composite turbine (inner) backplates were fabricated by Corning Glass Works. The BMAS/III material performed well in engine testing. Backplates of MAS material have not been engine tested.

Source record↗

Planetary Defence Activities Beyond NASA and ESA

The collision of a significant asteroid or comet with Earth represents a singular natural disaster for a myriad of reasons, including: its extraterrestrial origin; the fact that it is perhaps the only natural disaster that is preventable in many cases, given sufficient preparation and warning; its scope, which ranges from damaging a city to an extinction-level event; and the duality of asteroids and comets themselves---they are grave potential threats, but are also tantalising scientific clues to our ancient past and resources with which we may one day build a prosperous spacefaring future. Accordingly, the problems of developing the means to interact with asteroids and comets for purposes of defence, scientific study, exploration, and resource utilisation have grown in importance over the past several decades. Since the 1980s, more and more asteroids and comets (especially the former) have been discovered, radically changing our picture of the solar system. At the beginning of the year 1980, approximately 9,000 asteroids were known to exist. By the beginning of 2001, that number had risen to approximately 125,000 thanks to the Earth-based telescopic survey efforts of the era, particularly the emergence of modern automated telescopic search systems, pioneered by the Massachusetts Institute of Technology’s (MIT’s) LINEAR system in the mid-to-late 1990s. Today, in late 2019, about 840,000 asteroids have been discovered, with more and more being found every week, month, and year. Of those, approximately 21,400 are categorised as near-Earth asteroids (NEAs), 2,000 of which are categorised as Potentially Hazardous Asteroids (PHAs) and 2,749 of which are categorised as potentially accessible. The hazards posed to us by asteroids affect people everywhere around the world. As well, the opportunities presented by asteroids may benefit our entire species. Thus, with such a large number of currently known asteroids and so many yet to be discovered, it is not surprising that individuals, organisations, institutions, and governments all around the world have become interested in the study of asteroids. Indeed, a variety of government space agencies, private organisations, and individuals have worked on developing the means by which to observe, study, and even interact with asteroids and comets for purposes including science, exploration, pioneering, commerce, and planetary defence. This includes significant individual contributions by amateur asteroid astronomers all over the world. International cooperation in planetary defence within the contexts of the United Nations and the International Asteroid Warning Network (IAWN) are discussed in Chapter 2, and the activities undertaken by the world’s larger space agencies, ESA and NASA, are discussed in Chapters 3 and 4. But, what of the other agencies and institutions around the world who are also working on the problem of defence against hazardous asteroids and comets, or related topics? In this chapter we provide an overview, in alphabetical order, of some of the planetary defence related efforts that have been undertaken around the world beyond the activities at the United Nations, NASA, and ESA.

Barbee, Brent W.↗

Evaluating Portable Parallelization Strategies for Heterogeneous Architectures in High Energy Physics

High-energy physics (HEP) experiments have developed millions of lines of code over decades that are optimized to run on traditional x86 CPU systems. However, we are seeing a rapidly increasing fraction of floating point computing power in leadership-class computing facilities and traditional data centers coming from new accelerator architectures, such as GPUs. HEP experiments are now faced with the untenable prospect of rewriting millions of lines of x86 CPU code, for the increasingly dominant architectures found in these computational accelerators. This task is made more challenging by the architecture-specific languages and APIs promoted by manufacturers such as NVIDIA, Intel and AMD. Producing multiple, architecture-specific implementations is not a viable scenario, given the available person power and code maintenance issues. The Portable Parallelization Strategies team of the HEP Center for Computational Excellence is investigating the use of Kokkos, SYCL, OpenMP, std::execution::parallel and alpaka as potential portability solutions that promise to execute on multiple architectures from the same source code, using representative use cases from major HEP experiments, including the DUNE experiment of the Long Baseline Neutrino Facility, and the ATLAS and CMS experiments of the Large Hadron Collider. This cross-cutting evaluation of portability solutions using real applications will help inform and guide the HEP community when choosing their software and hardware suites for the next generation of experimental frameworks. We present the outcomes of our studies, including performance metrics, porting challenges, API evaluations, and build system integration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Housing Archetype Analysis for Home Energy-Efficient Retrofit in the Great Lakes Region

This project report details activities and results of the 'Market Characterization' project undertaken by the Cost Effective Energy Retrofit (CEER) team targeted toward the DOE goal of achieving 30%-50% reduction in existing building energy use. CEER consists of members from the Dow Chemical Company, Michigan State University, Ferris State University and Habitat for Humanity Kent County. The purpose of this market characterization project was to identify housing archetypes which are dominant within Great Lakes region and therefore offer significant potential for energy-efficient retrofit research and implementation due to the substantial number of homes possessing similar characteristics. Understanding the characteristics of housing groups referred to as 'archetypes' by vintage, style, and construction characteristics can allow research teams to focus their retrofit research and develop prescriptive solutions for those structure types which are prevalent and offer high potential uptake within a region or market. Key research activities included; literature review, statistical analysis of national and regional data of the American Housing Survey (AHS) collected by the U.S. Census Bureau, analysis of Michigan specific data, development of a housing taxonomy of architectural styles, case studies of two local markets (i.e., Ann Arbor and Grand Rapids in Michigan) and development of a suggested framework (or process) for characterizing local markets. In order to gain a high level perspective, national and regional data from the U.S. Census Bureau was analyzed using cross tabulations, multiple regression models, and logistic regression to characterize the housing stock and determine dominant house types using 21 variables.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Existing Whole-House Solutions Case Study: Evaluating Energy Savings in All-Electric Public Housing in the Pacific Northwest

This project analyzes the cost effectiveness of energy-saving measures installed by a large public housing authority in Salishan, and evaluates those solutions to improve efficiency of affordable housing for new and existing homes. Research focuses on the modeled and measured energy usage of the first six phases of construction, and compares the energy usage of those phases to phase 7.

BA-PIRC↗

Solar energy for process heat: Design/cost studies of four industrial retrofit applications

Five specific California plants with potentially attractive solar applications were identified in a process heat survey. These five plants were visited, process requirements evaluated, and conceptual solar system designs were generated. Four DOE (ERDA) sponsored solar energy system demonstration projects were also reviewed and compared to the design/cost cases included in this report. In four of the five cases investigated, retrofit installations providing significant amounts of thermal energy were found to be feasible. The fifth was rejected because of the condition of the building involved, but the process (soap making) appears to be an attractive potential solar application. Costs, however, tend to be high. Several potential areas for cost reduction were identified including larger collector modules and higher duty cycles.

French, R. L.↗

The Functional Resonance Analysis Method for a systemic risk based environmental auditing in a sinter plant: A semi-quantitative approach

Environmental auditing is a main issue for any production plant and assessing environmental performance is crucial to identify risks factors. The complexity of current plants arises from interactions among technological, human and organizational system components, which are often transient and not easily detectable. The auditing thus requires a systemic perspective, rather than focusing on individual behaviors, as emerged in recent research in the safety domain for socio-technical systems. We explore the significance of modeling the interactions of system components in everyday work, by the application of a recent systemic method, i.e. the Functional Resonance Analysis Method (FRAM), in order to define dynamically the system structure. We present also an innovative evolution of traditional FRAM following a semi-quantitative approach based on Monte Carlo simulation. This paper represents the first contribution related to the application of FRAM in the environmental context, moreover considering a consistent evolution based on Monte Carlo simulation. The case study of an environmental risk auditing in a sinter plant validates the research, showing the benefits in terms of identifying potential critical activities, related mitigating actions and comprehensive environmental monitoring indicators. - Highlights: • We discuss the relevance of a systemic risk based environmental audit. • We present FRAM to represent functional interactions of the system. • We develop a semi-quantitative FRAM framework to assess environmental risks. • We apply the semi-quantitative FRAM framework to build a model for a sinter plant.

54 ENVIRONMENTAL SCIENCES↗

UIR-Net: Object Detection in Infrared Imaging of Thermomechanical Processes in Automotive Manufacturing

Thermomechanical processes (TMPs) such as resistance spot welding (RSW) and hot stamping are widely used in automotive manufacturing. Recent advancement in sensing technology has led to an increasing adoption of thermographic cameras to capture the infrared (IR) radiation of a metal part (or component of a part) during its thermomechanical processing or immediately after the process when the part is still hot. Detecting the object(s) of interest from raw IR images is an essential step in analyzing these data. Deep learning (DL) has been a recent success for object detection (OD), but the application of DL-based OD for industrial IR images in manufacturing is largely lagging behind. The major contribution of this work, which is also the distinction from previous OD studies, is the capability of building the OD model with unlabeled IR images, i.e., imaging data without accurate information indicating the object position. Here, the architecture of Unsupervised IR Image Net (UIR-Net) is designed to accommodate the unique characteristics of IR images from TMPs in manufacturing. This study presents a novel method for OD in unlabeled IR images from TMPs. The proposed method, called UIR-Net, consists of two components: label generation and DL model construction. Two case studies from automotive manufacturing, RSW and hot stamping, are reported to demonstrate the feasibility and effectiveness of the proposed method.

42 ENGINEERING↗