Na2Mg2(CO3)2 double salt absorbents for CO2 removal from warm gas streams
Poster
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Poster
Explore the source record for details and available documents.
Explore the source record for details and available documents.
GE Global Research was contracted by the Department of Energy to design and build a bench-scale process for a novel phase-changing aminosilicone-based CO2 capture solvent (award number DEFE0013687). As part of this program, a technology EH&S assessment (Subtask 5.1) has been completed for a CO2 capture system for a 550 MW coal-fired power plant. The assessment focuses on two chemicals used in the process, the aminosilicone solvent, GAP-0, and dodecylbenzenesulfonic acid (DDBSA), the GAP-0 carbamate formed upon reaction of the GAP-0 with CO2, and two potential byproducts formed in the process, GAP-0/SOx salts and amine-terminated, urea-containing silicone (also referred to as “ureas” in this report). The EH&S assessment identifies and estimates the magnitude of the potential air and water emissions and solid waste generated by the process and reviews the toxicological profiles of the chemicals associated with the process. Details regarding regulatory requirements, engineering controls, and storage and handling procedures are also provided in the following sections.
Explore the source record for details and available documents.
Heat pipes and vapour chambers work on heat exchange phenomena of two-phase flow and are widely used for in-dustrial and commercial applications. These devices offer very high effective thermal conductivities (5,000-200,000 W/m/K) and are adaptable to various sizes, shapes, and ori-entations. Although they have been found to be an excel-lent thermal management solution for laptops, satellites, and many things in-between, heat pipes and vapour cham-bers have yet to be adopted for use at particle accelerator facilities where they offer the possibility of more compact and more efficient means to remove heat from unwanted synchrotron radiation. As with all technologies, there are inherent limitations. Foremost, they are limited by practi-cality to serve as local heat transfer devices; heat transfer over long distances is likely best provided by other means. Heat pipes also introduce unique failure modes which must be considered.
The Y-12 National Security Complex (Y-12) is performing work to modernize the recovery, purification, and consolidation of un-irradiated, highly enriched uranium metal. The development of advanced technology such as Electrorefining (ER) eliminates many of the intermediate chemistry systems and processes that are the current and historical basis of uranium processing at Y-12. The ER system processes impure broken uranium metal pieces into a high-purity uranium metal disk. The overall system consists of an ER cell, salt vaporization furnace (SVF), and uranium consolidation furnace (UCF).
In the preliminary design stage of a wave energy converter (WEC), fast and reliable simulation tools are required. High-fidelity numerical models are usually employed to study the wave-structure interaction, yet the computational cost is demanding. Instead, mid-fidelity models provide simulations in the order of real time. In this study, Uppsala University WEC operates in a relatively mild sea state and is modeled using WEC-Sim. The model is verified based on OpenFOAM simulations. To analyze the ability of mid-fidelity model to capture the WEC dynamics, the system is investigated separately in 1, 2 and 3 DoF. The contribution of viscous phenomena is examined. Moreover, linear and weakly non-linear solutions provided by WEC-Sim are studied. The results obtained indicate that the viscous effects in heave and surge motion can be neglected but not for the pitch. The weakly non-linear WEC-Sim solution successfully agrees with the CFD, whereas the linear solution could drive to misleading results.
In the preliminary design stage of a wave energy converter (WEC), fast and reliable simulation tools are required. High-fidelity numerical models are usually employed to study the wave-structure interaction, yet the computational cost is demanding. Instead, mid-fidelity models provide simulations in the order of real time. In this study, Uppsala University WEC operates in a relatively mild sea state and is modeled using WEC-Sim. The model is verified based on OpenFOAM simulations. To analyze the ability of mid-fidelity model to capture the WEC dynamics, the system is investigated separately in 1, 2 and 3 DoF. The contribution of viscous phenomena is examined. Moreover, linear and weakly non-linear solutions provided by WEC-Sim are studied. The results obtained indicate that the viscous effects in heave and surge motion can be neglected but not for the pitch. The weakly non-linear WEC-Sim solution successfully agrees with the CFD, whereas the linear solution could drive to misleading results.
Radionuclide therapy combines the specificity of cancer cell targeting with the well-known cytotoxic effects of ionizing radiation. It has the potential to simultaneously eradicate both the primary tumor site as well as the metastatic extent of the disease throughout the body. Radionuclide therapy in the form of {sup 131}Imetaiodobenzylguanidine ({sup 131}I-MIBG) has been used for several years to treat pediatric patients with advanced forms of neuroblastoma. {sup 131}I-MIBG treatments have improved palliation and progression-free survival rates in predominantly relapsed and refractory patients who have already endured an extensive chemotherapy regimen. MIBG is selectively taken up by an active transport mechanism in only neuroblastoma cells, limiting its applicability to other pediatric cancer types and additional radionuclide therapy options are needed. Several preclinical and clinical trials have shown selective in vitro uptake of {sup 131}I-CLR1404 in pediatric cancer cell lines. The focus of this work was to perform mouse-specific Monte Carlo-based dosimetry in several pediatric cancer xenografts being treated with {sup 131}I-CLR1404. Mouse-specific Monte Carlo-based dosimetry in radionuclide therapy can offer additional insight on the efficacy of new radiopharmaceuticals in organs and tumor volumes. In addition, this work demonstrates a clear dose-response relationship in these models.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
(Ag,Cu)(In,Ga)Se2 thin films have been deposited by elemental co-evaporation over a wide range of compositions and their optical properties characterized by transmission and reflection measurements and by relative shift analysis of quantum efficiency device measurements. The optical bandgaps were determined by performing linear fits of (αhν)2 vs. hν, and the quantum efficiency bandgaps were determined by relative shift analysis of device curves with fixed Ga/(In+Ga) composition, but varying Ag/(Cu+Ag) composition. The determined experimental optical bandgap ranges of the Ga/(In+Ga) = 0.31, 0.52, and 0.82 groups, with Ag/(Cu+Ag) ranging from 0 to 1, were 1.19-1.45 eV, 1.32-1.56 eV, and 1.52-1.76 eV, respectively. The optical bowing parameter of the different Ga/(In+Ga) groups was also determined.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided
Abstract not provided